• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.029 seconds

Information Creation Matrix Analysis for Analyzing National R&D Information System (국가 연구개발 정보체계 분석을 위한 정보생성행렬 분석)

  • 김종우;주영진;이성용;정현수
    • Journal of Information Technology Applications and Management
    • /
    • v.9 no.2
    • /
    • pp.57-70
    • /
    • 2002
  • In this paper, we propose matrix analysis methods for analyzing national R&D information creation. In order to analyze R&D information creation at national level, it is necessary to analyze whether information is created systematically for each technical category and for each information type. In this paper, ‘uniformity’and ‘concentration’criterions are proposed to check national R&D information creation and we provide formulas to measure the criterions. The criterions are applied to domestic information creation in information and communication domain to show the utilization of the proposed method.

  • PDF

Glow Discharge as Detector for Gas Chromatography (글로우방전을 이용한 가스크로마토그라프 검출기의 개발)

  • 김효진;박일영;장성기;김박광;박만기
    • YAKHAK HOEJI
    • /
    • v.37 no.1
    • /
    • pp.76-83
    • /
    • 1993
  • The changes in discharge current, emission and/or oscillation frequency of the electric oscillation of a glow discharge are the potential sensitive measure of the concentration of an impurity in the argon plasma supporting gas. A single jet enhanced glow discharge has been interfaced with the gas chromatograph via 1/8" O.D. tube with a heating pad to study the changes in discharge current. To investigate the optimum operating conditions of the glow discharge system as detector for gas chromatography, pressure, gas flow rate, discharge current, distance between the anode and the cathode have been studied.

  • PDF

Combustion Flame Diagnostics Using Laser-Induced Fluorescence (레이저 유도 형광법에 의한 연소화염 진단기법 연구)

  • Kim, T.K.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.5
    • /
    • pp.24-29
    • /
    • 1995
  • A laser system and signal aquisition system to use a laser-induced fluorescence technique were arranged to measure NO concentration. To identify the NO fluorescence signal, verification of the fluorescence was performed through use of comparison of the signals taken both in a undoped and doped calibration flames. Finally, the spatial NO number densities in partially premixed flames were found as a function of fuel-tube equivalence ratio(${\phi}_c$) and overall equivalence ratio(${\phi}_o$).

  • PDF

A Dissolved Oxygen Measurement System Using FET-type Dissolved Oxygen Sensor Array (FET형 용존산소 센서 어레이 측정시스템)

  • Jeong, H.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.259-265
    • /
    • 2001
  • FET-type dissolved oxygen sensor has the Pt working electrode around the pH-ISFET. Appling a voltage to the working electrode, the hydrogen ion which is proportional to the dissolved oxygen concentration occurs around the pH sensing gate and we can measure the dissolved oxygen concentration by detecting pH concentration through the pH-ISFET. In this paper, a dissolved oxygen measurement system using FET-type dissolved oxygen sensor array which adopt a specific algorithm to enhance the reliability has been developed and we compared its performance with the commercial dissolved oxygen measurement system.

  • PDF

A Study on the Urinary Hippuric Acid Excretions of Workers Exposed to Toluene in Working place (작업장에서 톨루엔에 노출된 근로자들의 마뇨산 배설량에 관한 연구)

  • 이병호;김부길;권수자
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.445-450
    • /
    • 2001
  • This study was carried out In Investigate the correlation between toluene In air and hippuric acid In human urine, which 1.: based on the results of the health check-in and the measure of working environment, was investigated for two years. The concentration of toluene in air for the five working places in Yang-San area were ranged from 39.05±10.31 ppm to 4.04±3.38ppm and the mean value of those was 16.89±14.76ppm. The mean value was 16.89±14.76ppm which is below the permissible limit of toluene. The concentration of hippuric acid(HA) In the worker's urine were between 0.47g/ℓ and 0.76g/ℓ. There was mutual correlation (Υ=0.94) between the concentration of toluene in air and that of hippuric acid in urine. In case of male workers, the mean value of hippurlc acid In urine was 0.56g/ f and the female workers was 0.57g/ℓ that showed higher than the male's. However, there was no relationship between the workshop and the distinction of sex. From the mean value of toluene in air(T) and that of hippuric acid(H), we obtained the formula, Η=0.3logΤ+0.235.

  • PDF

Capacitance-type Alcohol Sensors using Porous Silicon Layer (다공질 실리콘 층을 이용한 정전용량형 알코올 센서)

  • Kim, Seong-Jeen
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.31-36
    • /
    • 1999
  • A capacitance-type sensor using porous silicon layer is developed to measure aqueous alcohol concentration. Since alcohol, so called ethanol, is very permeable into the silicon wafer, it is often used to help chemical reaction when the silicon wafer is processed under some aqueous solution. In this work, the sensing property was measured for the alcohol concentration from zero to near 100 percent with two types of samples with porous silicon layer formed in 25 and 35% HF solution, respectively. Good reliability as well as fast response time and good linearity were shown over 10kHz and the measured capacitance was observed to be inverse to alcohol concentration due to the decrease of the whole dielectric constant in porous silicon layer.

  • PDF

An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units (기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

A Study on Mensurement of NO Concentrations in Laminar Non-premixed H2/N2 Flame Using LIF (레이저 유도 형광법(LIF)을 이용한 층류 비예혼합 수소/질소 화염에서의 NO 농도 측정에 관한 연구)

  • Jin, Seong Ho;Kim, Sung Wook;Park, Kyoung Suk;Kim, Gyung Soo
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.4
    • /
    • pp.279-286
    • /
    • 2002
  • In this study, quantitative nitric oxide concentration distributions are investigated in the laminar non-premixed $H_2/N_2$ flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different $N_2$ dilution ratios varying from 20~80%, and fuel flow rate is fixed as Islpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. We applied same excitation line used in $CH_4$, premixed flame. Overall, NO concentration was rapidly decreased with Na addition and we could not measure the concentration any longer for $N_2$ dilution above 80%.

Surfactant-enhanced Soil Washing using Tween and Tergitol Series Surfactants for Kuwait Soil Heavily Contaminated with Crude Oil

  • Heo, Hyojin;Lee, Minhee
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.5
    • /
    • pp.26-33
    • /
    • 2015
  • Batch experiments were performed to investigate the feasibility of a surfactant-enhanced soil washing process for soils heavily contaminated with crude oil in Kuwait. TPH concentration of the contaminated soil was 223,754 mg/kg, sampled from the bottom of a vaporized oil extraction pond in the Burgan reservoir field. Commercialized eight nonionic surfactants (Tween and Tergitol series) were used to measure the aqueous solubility for the crude oil. Among them, two Tergitol surfactants were used to evaluate the TPH removal efficiency of the surfactant-enhanced soil washing for heavily contaminated Kuwait soil. The solubility of the crude oil in surfactant solution was in the order Tergitol 15-S-7 > Tergitol 15-S-9 > Tergitol 15-S-12 > Tween-80 > Tween-20 > Tween-60, which showed that the crude oil solubilities of the Tergitol series were higher than those of the Tween series. The TPH removal efficiencies of 2% and 5% Tergitol 15-S-9 solution were 59% and 65%, respectively. Because the residual TPH concentration in the washed soil was still higher than the clean-up level (10,000 mg/kg), the soil washing process was repeated five times. After the fifth washing, the residual TPH concentration in the soil went down to 7,680 mg/kg and its removal efficiency was 97%.

Analysis of Diesel Nano-particle Characteristics for Different Vehicle Test Mode in Diesel Passenger Vehicle (디젤 승용차량 시험모드별 극미세입자 배출 특성 해석)

  • Lee, Jin-Wook;Jung, Min-Won;Jeong, Young-Il;Cha, Kyong-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.114-120
    • /
    • 2008
  • Recently, the nano-PM's number concentration emitted by diesel internal combustion engine has focused on attention because this particulate matters are suspected being hazardous of human health. In this study, The nano-PM mass and size of diesel passenger vehicles were measured on chassis dynamometer test bench. The particulate matters(PM) emissions of these vehicles were investigated by number concentration too. A condensation particle counter(CPC) system was applied to measure the particle number and size concentration of diesel exhaust particles at the end of dilution tunnel along the NEDC(ECE15+EUDC) and CVS-75 vehicle test mode. As the research result, the characteristic of vehicle test mode on the diesel nano-particle number and size distribution was investigated in this study.