• Title/Summary/Keyword: concentration measure

Search Result 1,484, Processing Time 0.046 seconds

Variation Pattern of Gaseous Organochlorine Pesticides Concentration in Atmosphere (대기 중에서 가스상 유기염소계 농약의 농도변화 패턴)

  • Choi, Min-Kyu;Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.2 s.57
    • /
    • pp.111-118
    • /
    • 2007
  • This study was performed to measure gaseous Organochlorine Pesticides (OCPs : heptachlor epoxide, ${\alpha}/{\gamma}-chlordane$, trans-nonachlor, endosulfan, ${\gamma}-HCH$ and p, p'-DDE) concentration using PUF high volume sampler from June, 2000 to June, 2002 in the semi-rural atmosphere. Using monitoring data for two years, we tried to investigate the annual cycles of gaseous OCPs. We considered three functions to describe the annual cycle: Gaussian, Lorentzian and sinusoidal functions. These functions accounted for $54{\sim}91%$ of the variability in concentration for each gaseous OCPs, and the sinusoidal function gave the best fits. It was seen that the gaseous OCPs concentration increased during the warmer weather while decreased during colder weather. The variation of the gaseous OCPs concentration was closely similar to the variations of ambient temperature. The annual cycle of endosulfan was strongly higher than in comparison with other gaseous OCPs, while for ${\gamma}-HCH$, the cycle was weakly high and did not show apparent seasonal variation. The position of the annual maximum exists generally late July to early August. The period that showed levels more than a half maximum was from late June to early September.

Fluid dynamical characteristics of microencapsulated phase change material slurries (미립잠열슬러리의 유체역학적 특성연구)

  • 이효진;이승우;이재구
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

The Influence of Water Temperature and Food Concentration on the Filtration Rates of the Asiatic Clam, Corbicula fluminea (수온과 먹이생물의 농도 변화에 따른 재첩의 여과율 변동)

  • Lim, Kyeong-Hun;Shin, Hyun-Chool;Yang, Jae-Sam
    • The Korean Journal of Malacology
    • /
    • v.21 no.1
    • /
    • pp.19-24
    • /
    • 2005
  • This study was undertaken with the intent to describe the influence of water temperature and food concentration on the filtration rates of the Asiatic clam, Corbicula fluminea. The clams were collected at Lake Geumho near Yeongsan river, during March 2001. Food organism, Scenedesmus sp. (KMCC FC-34), was indoor-cultured in f/2 medium, and was used to measure the filtration rate of the clams. Filtration rate of the clams was measured by indirect method. Cell concentrations of food organisms were determined by direct counting cells using the hemacytometer under the light microscope. The filtration rate of the clams increased with water temperature up to circa $25^{\circ}C$. Above this temperature, the filtration rate decreased rapidly. The minimal filtration rate of the clams was recorded at $5^{\circ}C$. Thermal coefficient, $Q_10$ values at low temperature range were much higher than those at high temperature range. These results indicate the asiatic clam is more sensitive in cold water like most of marine bivalves. There was a strong reversed correlation between filtration rate and food concentration. Filtration rate of the clams was reduced as food concentration was increased.

  • PDF

Phenolphthalein Solution Discoloration determined by alkali concentration in long-term concrete check surface (장기재령 콘크리트의 할렬면에서 알칼리농도에 의한 페놀프탈레인 용액의 변색)

  • Park, Hyun;Lee, Jong-Rok;Kim, Kwang-Ki;Kim, Woo-Jae;Kim, Jong-Sub;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.183-186
    • /
    • 2008
  • Carbonation is measured as Phenolphthalein Solution, it is possible to confirm the scope of alkali through acid and basic reaction. Then, Concrete Basic Reaction is decided according to alkali concentration depending on Potassium Hydroxide Now that Carbonation is gradually produced toward inner side from outer side, with time going by, it doesnt work, to some adequate depth, in as fast time as compulsory facilitating test. Thus, this research thesis made a comparative analysis on concrete phenomenal discoloration borderline following Phenolphthalein Solution, as part of a bid to measure Carbonation. Also, the thesis measured Concrete Alkali Concentration. The result showed that concrete coloring is classified into red and scarlet according to alkali concentration, and into borderline breakpoint of the speckle of scarlet and carbonation reaction. The higher chroma becomes with concrete decolorizing, the higher alkali concentration becomes.

  • PDF

Preparation of Polyurethane Diagnostic Membranes for Blood Glucose Measurements (6) : Effects of Hematocrit on Measurements of Glucose Concentration (혈당측정을 위한 폴리우레탄 진단막의 제조(6) : 헤마토크릿이 글루코우즈의 농도 측정에 미치는 영향)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.20 no.3
    • /
    • pp.197-202
    • /
    • 2010
  • Polyurethane diagnostic membranes were prepared to measure blood glucose level of diagnostics. Final absorbances at 680 nm through activated polyurethane membranes were measured at various concentration of glucose in blood. The end-point results of varing absorbance values as time (K/S) was found to have a linear relationship toward the blood glucose concentration. The effects of hematocrit on the glucose concentration measurements were examined. In low hematocrit, dose-response slope (DRS) values between gluose concentration and K/S values did not show the big differences compared to those in plasma. However, in high hematocrit (more than 40%) DRS values were considerably decreased.

Measurement of Structural Stress Concentration by PVDF Film Sensors (압전필름센서에 의한 구조물의 응력집중의 측정)

  • Kwon, Il-Bum;Kim, Chi-Yeop;Choi, Man-Yong;Lim, Jong-Mook;Kim, In-Gul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.109-119
    • /
    • 2000
  • PVDF film sensor was applied to measure the stress concentration for monitoring the structural integrity. The strain calibration of this film sensor was performed by the bending test of aluminum beam. The PVDF sensor and the electrical strain gage were bonded on the beam. When the beam was loaded, the output of electrical strain gage was compared with the output of the PVDF sensor. The waveform of PVDF sensor output was shown as the same form of the output of electrical strain gage. The gain was determined as 1.7 by comparing these two signals to determine the exact value of the strain. In order to experiment the stress concentration, the stress field was analyzed by finite element analysis. The tensile test of notched steel specimens was conducted to develop the measurement technique of stress concentration. The output voltage ratio between the PVDF sensor near the notch and the PVDF sensor far from the notch could give the information about the load bearing capacity of steel specimen.

  • PDF

Study on the level of dust concentration with affecting factors at a dust emissing workshops (분진 발생 작업장의 분진 발생 실태 및 영향인자에 관한 연구)

  • Kim, Hee-Man;Kim, Don-Kyoun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.227-239
    • /
    • 1993
  • The author selected 77 dust emissing processes from 71 types of industries which placed in Sasang Industrial Complex in Pusan. The level of total dust was measured as areal concentration and personal exposure concentration by low volume air sampler and personal air sampler, respectively. Collected samples were classified into 5 groups (chemicals and rubber product, metal product, sawmills and wood, foundries and others). Respirable particulate and total dust of areal and personal exposure were analyzed. The results were as follows; 1. All of the respirable dust concentration and total dust of areal and personal concentration were log-normally distributed. 2. Geometric mean of respirable particulate of personal exposure concentration measured $0.55mg/m^3$ in the first group, $0.86mg/m^3$ in the second group, $0.39mg/m^3$ in the third group, $0.81mg/m^3$ in the forth group and $0.52mg/m^3$ in the fifith group. The exceed rates over TLV (thehold limit values) of total dust were 31.3% in the first group, 31.3% in the second group, 70% in the third group, 80% in the forth group and 13.3% in the fifth group. 3. There were singnificant difference between areal and personal exposure concentration and personal exposure concentration was higher than that of area. 4. In the case of high ratio of respirable particulate to total dust, pneumoconiosis incidence was high even though the workshop was opened and emissing dust concentration was low. These findings suggest that it is desirable to measure respirable particulate in environmental assessment of dust emissing workshops.

  • PDF

Local Concentration and Flame Temperature Characteristics of Combustion Product in Premixed LPG/Air Flames (예혼합 LPG/공기화염에서 연소생성물의 국소농도 및 화염온도특성)

  • 김태권;장준영
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.77-84
    • /
    • 2001
  • Measurements of local CO, $CO_2$, $O_2$, $N_2$, $C_3$H$_{8}$, NOx concentrations and flame temperature are made for partially premixed flame with and without acoustic excitation. The CO, $CO_2$, $O_2$, $N_2$, and $C$_3$H_8$ concentrations are determined by thermal conductivity detection (Gas-chromatograph) and NOx concentrations are determined by chemiluminescent detection (NOx analyser). To measure local sample concentration, sampling probe was made by quartz with inlet diameter of 0.25mm. In the case of excitation, the visual shape of the flame is changed from laminar flame to turbulent-like flame. The flame length is also reduced, and the flame width becomes broad. In the observation of emission concentration without acoustic excitation, meanwhile, the $CO_2$ and NOx concentrations peak at flame front where the mixture meets with surrounding air, and the CO concentration is increasing at maximum position of CO2 concentration and peaks at the centerline of the burner. In the case of acoustic excitation, the $CO_2$ concentration is widely occurred at nozzle of the burner and is higher relative to unexcitation. The CO concentration is much reduced, but NOx concentration is more increasing. And flame temperature is higher relative to unexcitation. These are caused by enhancing of mixing with surrounding air due to excitation. However, in the case of acoustic excitation, the total NOx concentration is reduced because of the shortened flame length which affects residence time.e.

  • PDF

Development of concentration measurement system in online education based on OpenCV (온라인 교육을 위한 OpenCV 기반 집중도 측정 시스템 개발)

  • Yim, Dae-Geun;Koh, Kyu Han;Jo, Jaechoon
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.195-201
    • /
    • 2020
  • There have been many developments and innovations in the educational environments in line with the rapidly evolving information age. E-Learning is a representative example of this rapid evolution. However, E-Learning is challenging to maintain students' concentration because of the low engagement level and limited interactions between instructors and students. Additionally, instructors have limitations in identifying learners' concentration. This paper proposes a system that can measure E-learning users' concentration levels by detecting the users' eyelid movement and the top of the head. The system recognizes the eyelid and the top of the head and measures the learners' concentration level. Detection of the eyelid and the top of the head triggers an event to assess the learners' concentration level based on the users' response. After this process, the system provides a normalized concentration score to the instructor. Experiments with experimental groups and control groups were conducted to verify and validate the system, and the concentration score showed more than 90% accuracy.

Prediction for the Lifetime Effective Dose and Radon Exposure Risk by using Dose Conversion Convention: Base on the Indoor Radon Concentration of Lecture Room in a University (선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도 예측: 대학 강의실 라돈농도 중심으로)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.243-249
    • /
    • 2018
  • The indoor radon concentration was measured in the lecture room of the university and the radon concentration was converted to the amount related to the radon exposure using the dose conversion convention and compared with the reference levels for the radon concentration control. The effect of indoor radon inhalation was evaluated by estimating the life effective dose and the risk of exposure. To measure the radon concentration, measurements were made with a radon meter and a dedicated analysis Capture Ver. 5.5 program in a university lecture room from January to February 2018. The radon concentration measurement was carried out for 5 consecutive hours for 24 hours after keeping the airtight condition for 12 hours before the measurement. Radon exposure risk was calculated using the radon dose and dose conversion factor. Indoor radon concentration, radon exposure risk, and annual effective dose were found within the 95% confidence interval as the minimum and maximum boundary ranges. The radon concentration in the lecture room was $43.1-79.1Bq/m^3$, and the maximum boundary range within the 95% confidence interval was $77.7Bq/m^3$. The annual effective dose was estimated to be 0.20-0.36 mSv/y (mean 0.28 mSv/y). The life-time effective dose was estimated to be 0.66-1.18 mSv (mean $0.93{\pm}0.08mSv$). Life effective doses were estimated to be 0.88-0.99 mSv and radon exposure risk was estimated to be 12.4 out of 10.9 per 100,000. Radon concentration was measured, dose effective dose was evaluated using dose conversion convention, and degree of health hazard by indoor radon exposure was evaluated by predicting radon exposure risk using nominal hazard coefficient. It was concluded that indoor living environment could be applied to other specific exposure situations.