• Title/Summary/Keyword: concentration image

Search Result 496, Processing Time 0.025 seconds

A Study on the Diesel Flame by Means of Image Analysis ofn Shadow Photographs (음영사진의 화상해석에 의한 디젤화염에 관한 연구)

  • 장영준;박호준;신본무정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1222-1233
    • /
    • 1990
  • The formation and oxidation processes of soot particles in a diesel flame were investigated with a rapid compression machine. A cloud of soot particles was successfully visualized by means of the instantaneous laser shadow photographs technique and the equivalence ratio of the soot formation zone was estimated from a measured fuel concentration distribution in a nonevaporating spray. The temporal and spatial variation of soot concentration in the flame was also correlated with the rate of heat release. Soot particles appears first in a region near the flame tip when diffusion combustion period starts, and its concentration is a maximum at about the end of injection, then decreases due to oxidation. The reason for soot being formed in a fuel lean region near the flame tip is the evaporated fuel requires time to be pyrolized as it travels through the burning fuel rich zone towards the flame tip.

Experimental Study on the Soot Formation Characteristics of Alkane-based Single Fuel Droplet (알케인계 단일 연료 액적의 Soot 생성 특성에 관한 실험적 연구)

  • Lim, Young Chan;Suh, Hyun Kyu
    • Journal of ILASS-Korea
    • /
    • v.22 no.2
    • /
    • pp.80-86
    • /
    • 2017
  • The soot formation characteristics of various alkane-based single fuel droplets were studied in this work. Also, This study was performed to provide the database of the soot behavior and formation of alkane-based single fuel droplet. The experimental conditions were set to 1.0 atm of ambient pressure ($P_{amb}$), 21% of oxygen concentration ($O_2$) and 79% of nitrogen concentration ($N_2$). Combustion and soot formation of single fuel droplet was visualized by visualization system with high speed camera. At the same time, ambient pressure, oxygen concentration and nitrogen concentration were maintained by ambient condition control system. Soot formation characteristics was analyzed and compared on the basis of intensity ratio ($I/I_0$) of background image. The results of toluene fuel droplet showed the largest soot generation. Soot volume fraction ($f_v$) was almost the same under the identical fuel types regardless of various initial droplet diameter ($d_0$) since thermophoretic flux was not much changed under the same ambient conditions.

Determination of Ammonia Nitrogen by Color Saturation Measurement System (채도측정시스템을 이용한 암모니아성 질소의 정량방법)

  • Lee, Hyeong-Choon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The objective of this study was to investigate whether the ammonia nitrogen concentration of aqueous samples such as drinking water can be determined by measuring the saturation of the samples colored by indophenol method. Methods: A color saturation measurement system was constructed by connecting a notebook computer to an image acquisition device composed of a PC camera and a light source, and was then used to measure the saturation of samples colored by blue indophenol complex. Results: Between two available light sources, a fluorescent lamp was selected due to its demonstrating better linearity between color saturation and ammonia nitrogen concentration. Prediction by quadratic regression was more accurate than by linear regression, and prediction by quadratic regression in the concentration range of 0.1-1.0 $mg/l$ was more accurate than in the concentration range of 0.0-1.0 $mg/l$. Regression-based predictions over 0.25 $mg/l$, 0.55 $mg/l$ and 0.75 $mg/l$ concentrations were implemented both by spectrophotometric method and by measuring color saturation. In the case of 0.25 $mg/l$, the predicted concentration by spectrophotometric method was $0.256{\pm}0.0076\;mg/l$ and the predicted concentration by measuring color saturation was $0.246{\pm}0.0086\;mg/l$ (p=0.051). In the case of 0.55 $mg/l$, they were $0.561{\pm}0.0068\;mg/l$ and $0.564{\pm}0.0166\;mg/l$ (p=0.660). In the case of 0.75 $mg/l$, they were $0.755{\pm}0.0139\;mg/l$ and $0.762{\pm}0.0088\;mg/l$ (p=0.215). Conclusions: There were no statistically significant differences (p>0.05) between the data from the two methods in all three of the concentrations. Therefore, the color saturation measurement method proposed in this paper may be considered applicable for determining the ammonia nitrogen concentration of aqueous samples such as drinking water.

Comparison of Composite Methods of Satellite Chlorophyll-a Concentration Data in the East Sea

  • Park, Kyung-Ae;Park, Ji-Eun;Lee, Min-Sun;Kang, Chang-Keun
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.6
    • /
    • pp.635-651
    • /
    • 2012
  • To produce a level-3 monthly composite image from daily level-2 Sea-viewing Wide Field-of-view Sensor (SeaWiFS) chlorophyll-a concentration data set in the East Sea, we applied four average methods such as the simple average method, the geometric mean method, the maximum likelihood average method, and the weighted averaging method. Prior to performing each averaging method, we classified all pixels into normal pixels and abnormal speckles with anomalously high chlorophyll-a concentrations to eliminate speckles from the following procedure for composite methods. As a result, all composite maps did not contain the erratic effect of speckles. The geometric mean method tended to underestimate chlorophyll-a concentration values all the time as compared with other methods. The weighted averaging method was quite similar to the simple average method, however, it had a tendency to be overestimated at high-value range of chlorophyll-a concentration. Maximum likelihood method was almost similar to the simple average method by demonstrating small variance and high correlation (r=0.9962) of the differences between the two. However, it still had the disadvantage that it was very sensitive in the presence of speckles within a bin. The geometric mean was most significantly deviated from the remaining methods regardless of the magnitude of chlorophyll-a concentration values. Its bias error tended to be large when the standard deviation within a bin increased with less uniformity. It was more biased when data uniformity became small. All the methods exhibited large errors as chlorophyll-a concentration values dominantly scatter in terms of time and space. This study emphasizes the importance of the speckle removal process and proper selection of average methods to reduce composite errors for diverse scientific applications of satellite-derived chlorophyll-a concentration data.

Magnetite for phosphorus removal in low concentration phosphorus-contained water body

  • Xiang, Heng;Liu, Chaoxiang;Pan, Ruiling;Han, Yun;Cao, Jing
    • Advances in environmental research
    • /
    • v.3 no.2
    • /
    • pp.163-172
    • /
    • 2014
  • Magnetite was chosen as a typical adsorbent to study its phosphate adsorption capacity in water body with low concentration of phosphorus (below $2mg\;PL^{-1}$). Magnetite was collected from Luoyang City, Henan Province, China. In this research, three factors have been studied to describe the adsorption of phosphate on magnetite, which was solution concentration (concentration ranging from 0.1 to $2.5mg\;PL^{-1}$), suspension pH (1 to 13) and temperature (ranging from $10^{\circ}C$ to $40^{\circ}C$). In addition, the modified samples had been characterized with XRD and FE-SEM image. The results show that iron ions contains in magnetite were the main factors of phosphorus removal. The behavior of phosphorus adsorption to substrates could be fitted to both Langmuir and Freundlich isothermal adsorption equations in the low concentration phosphorus water. The theoretical saturated adsorption quantity of magnetite is 0.158 mg/g. pH has great influence on the phosphorus removal of magnetite ore by adsorption. And pH of 3 can receive the best results. While temperature has little effect on it. Magnetite was greatly effective for phosphorus removal in the column experiments, which is a more practical reflection of phosphorous removal combing the adsorption isotherm model and the breakthrough curves. According to the analysis of heavy metals release, the release of heavy metals was very low, they didn't produce the secondary pollution. The mechanism of uptake phosphate is in virtue of chemisorption between phosphate and ferric ion released by magnetite oxidation. The combined investigation of the magnetite showed that it was better substrate for water body with low concentration of phosphorus.

A Study on Visual Factors Affecting Purchase of Convenient Store's Packed-meal on Mobile Application (모바일 애플리케이션을 통한 편의점 도시락 구매 과정에 영향을 미치는 시각 요소에 관한 연구)

  • Lee, Da-Hyun;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.443-448
    • /
    • 2020
  • The purpose of research is identifying visual factors affecting purchase of convenient store packed-meals through mobile applications. Previous studies have not covered mobile applications on purchase of convenient store packed-meals and this inspired the research topic. Document analysis and online survey are mainly implemented and 4 visual factors; typography, product image, main color, brand logo have been set as a research variables. It is revealed that consumers recognize product image prior to the rest and their purchase intentions are most significantly affected by product image. In conclusion, the product image should encourage consumers to have expectation on packed-meal and need to deliver credibility at the same time. Hence, the application should be designed to solely spotlight product image to lead consumer's concentration on it. The research can be further expanded by including non-visual factors as its variables or increasing scale of survey samples.

Usefulness of Image Registration in Brain Perfusion SPECT (Brain Perfusion SPECT에서 Image Registration의 유용성)

  • Song, Ho-June;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Purpose: The brain perfusion SPECT is the examination which is able to know adversity information related brain disorder. But brain perfusion SPECT has also high failure rates by patient's motions. In this case, we have to use two days method and patients put up with many disadvantages. We think that we don't use two days method in brain perfusion SPECT, if we can use registration method. So this study has led to look over registration method applications in brain perfusion SPECT. Materials and Methods: Jaszczak, Hoffman and cylindrical phantoms were used for acquiring SPECT image data on varying degree in x, y, z axes. The phantoms were filled with $^{99m}Tc$ solution that consisted of a radioactive concentration of 111 MBq/mL. Phantom images were acquired through scanning for 5 sec long per frame by using Triad XLT9 triple head gamma camera (TRIONIX, USA). We painted the ROI of registration image in brain data. So we calculated the ROIratio which was different original image counts and registration image counts. Results: When carring out the experiments under the same condition, total counts differential was from 3.5% to 5.7% (mean counts was from 3.4% to 6.8%) in phantom and patients data. In addition, we also run the experiments in the double activity condition. Total counts differential was from 2.6% to 4.9% (mean counts was from 4.1% to 4.9%) in phantom and patients data. Conclusion: We can know that original and registration data are little different in image analysis. If we use the image registration method, we can improve disadvantage of two days method in brain perfusion SPECT. But we must consider image registration about the distance differences in x, y, z axes.

  • PDF

Cytotoxicity of Multipurpose Contact Lens Solutions on the Cultured Corneal Epithelial Cells Evaluated by Image Analysis (이미지 분석법을 이용한 소프트 콘택트렌즈용 다목적용액의 각막상피세포 독성 평가)

  • Kim, Nam-Youl;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.51-60
    • /
    • 2015
  • Purpose: To determine the effect of marketed multipurpose contact lens solutions (MPSs) on human corneal epithelial cells (HCEpiCs) toxicity by using image analysis. Methods: HCEpiCs were exposed six MPSs (product A-F) at 0.05~50% for 2h, 12h, 24h, and 48h respectively. HCEpiCs were fixed and stained with Draq5 after exposure with MPSs, and the cell viability and apoptosis were evaluated by using confocal microscope and ImageXpress UltraTM. Results: Viabilities of HCEpiCs exposed to MPS A-F for a 2h were not affected, while reductions (52~75%) in cell viability over a 12h exposure of MPS B, MPS C, MPS D and MPS F, and significant more reductions (29~73%) over a 24h and 48h-exposure. Apoptosis of HCEpiC was not affect over a 12h MPS exposure, however was significantly increased (199~526%) over 24h and 48h MPS exposure. Among the products MPS D, E and F reduced viability of HCEpiCs and apoptosis increased more than MPS A (p<0.05). Conclusions: Lower concentration of MPSs have not an cytotoxic effect on HCEpiCs, however higher concentration of MPSs induce apoptosis and reduce viability of HCEpiCs. Therefore, it need to develop MPS having antimicrobial effectiveness with low cytotoxicity.

A Study on the Tracking of Count-Based Volumetric Changes in Nuclear Medicine Imaging (핵의학 영상에서 계수기반 체적변화 추적에 관한 고찰)

  • Ji-Hyeon Kim;Jooyoung Lee;Hoon-Hee Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.57-69
    • /
    • 2024
  • Purpose: Quantitative analysis through count measurement in nuclear medicine planar images is limited by analysis techniques that are useful for obtaining various clinical information or by organ overlap or artifacts in actual clinical practice. On the other hand, the use of SPECT tomography images is quantitative analysis using volume rather than planar, which is not only free from problems such as projection overlap, but also has excellent quantitative accuracy. In the use of developing SPECT quantitative analysis technology, this study aims to compare the accuracy of quantitative analysis between ROI of the conventional planar images and VOI of the SPECT tomographic images in evaluating the count change happened by the volume change of the source. Materials and Methods: A 99mTcO4- source(200.17 MBq) was filled with sterilized water in the syringe to create a phantom with an inner diameter volume of 60 cc, and a planar image and a SPECT image were obtained by reducing the volume by 15 cc (25%) respectively. ROI and VOI(threshold: 1~45%, 5% interval) were set for each image obtained to estimate true count and measure the total count, and compared with the preseted volumetric change rate(%). Results: When volume changes of 25%, 50%, and 75% occurred in the initial volume of 60 cc(100%) of the phantom, the average count changes of the measured planar image were 26.8%, 53.2%, 77.5%, and the average count changes of the SPECT image were 24.4%, 50.9%, and 76.8%. In this case, the VOI size(cm3) set showed an average change rate of 25.4%, 51.1%, and 76.6%. The highest threshold value for the accuracy of radioactive concentration by VOI size (average error -1.03%) was 35%, and the VOI size of the same threshold had an error of -17.1% on average compared to the actual volume. Conclusion: On average, the count-based volumetric change rate in nuclear medicine images was able to track changes more accurately using VOI than ROI, but there was no significant difference with relatively similar value. However, the accuracy of radioactive concentration according to individual VOI sizes did not match, but it is considered that a relatively accurate quantitative analysis can be expected when the size of VOI is set smaller than the actual volume.

Evaluating Picture Quality of Image Plates in Digital CR Systems (디지털 CR시스템에서 Image plate의 화질 평가)

  • Kwak, Byung-Joon;Ji, Tae-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.216-222
    • /
    • 2011
  • Lab effectively supplemented the effects of outside radiation on image plates in the process of image acquisition of CR (computed radiography) systems and conducted for effective utilization in the case of clinical application. For this, Lab classified the storage places and time periods of image plates and compared and analyzed the differences between small dark spots. Lab also assessed the concentration distribution within the boundaries of images. Lab compared and measured the number of dark spots in a light room and a dark room depending on the storage places of image plates and found that dark spots slightly increased in an image plate when stored in a light room on the first and second days. Dark spots increased in proportion to the length of time stored. In the case of the image plate stored in a dark room, the number of dark spots remarkably decreased. With regard to picture quality as related to the location of image plates, the damage to picture quality could be reduced by locating regions of interest in the center. With regard to differences in sharpness following changes in the thickness of subjects, fewer scatter rays occurred and sharpness improved by reducing the thickness of subjects as much as possible. To get medical images of excellent quality, image plates should be managed effectively and it is desirable to keep images plates in dark iron plate boxes and not to expose them to outside radiation for a long time.