• Title/Summary/Keyword: computed tomography image

Search Result 966, Processing Time 0.024 seconds

Prognostic Implication of Volumetric Quantitative CT Analysis in Patients with COVID-19: A Multicenter Study in Daegu, Korea

  • Byunggeon Park;Jongmin Park;Jae-Kwang Lim;Kyung Min Shin;Jaehee Lee;Hyewon Seo;Yong Hoon Lee;Jun Heo;Won Kee, Lee;Jin Young Kim;Ki Beom Kim;Sungjun Moon;Sooyoung, Choi
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1256-1264
    • /
    • 2020
  • Objective: Lung segmentation using volumetric quantitative computed tomography (CT) analysis may help predict outcomes of patients with coronavirus disease (COVID-19). The aim of this study was to investigate the relationship between CT volumetric quantitative analysis and prognosis in patients with COVID-19. Materials and Methods: CT images from patients diagnosed with COVID-19 from February 18 to April 15, 2020 were retrospectively analyzed. CT with a negative finding, failure of quantitative analysis, or poor image quality was excluded. CT volumetric quantitative analysis was performed by automated volumetric methods. Patients were stratified into two risk groups according to CURB-65: mild (score of 0-1) and severe (2-5) pneumonia. Outcomes were evaluated according to the critical event-free survival (CEFS). The critical events were defined as mechanical ventilator care, ICU admission, or death. Multivariable Cox proportional hazards analyses were used to evaluate the relationship between the variables and prognosis. Results: Eighty-two patients (mean age, 63.1 ± 14.5 years; 42 females) were included. In the total cohort, male sex (hazard ratio [HR], 9.264; 95% confidence interval [CI], 2.021-42.457; p = 0.004), C-reactive protein (CRP) (HR, 1.080 per mg/dL; 95% CI, 1.010-1.156; p = 0.025), and COVID-affected lung proportion (CALP) (HR, 1.067 per percentage; 95% CI, 1.033-1.101; p < 0.001) were significantly associated with CEFS. CRP (HR, 1.164 per mg/dL; 95% CI, 1.006-1.347; p = 0.041) was independently associated with CEFS in the mild pneumonia group (n = 54). Normally aerated lung proportion (NALP) (HR, 0.872 per percentage; 95% CI, 0.794-0.957; p = 0.004) and NALP volume (NALPV) (HR, 1.002 per mL; 95% CI, 1.000-1.004; p = 0.019) were associated with a lower risk of critical events in the severe pneumonia group (n = 28). Conclusion: CRP in the mild pneumonia group; NALP and NALPV in the severe pneumonia group; and sex, CRP, and CALP in the total cohort were independently associated with CEFS in patients with COVID-19.

Gastric Metastasis from Gastric-Type Mucinous Adenocarcinoma of Uterine Cervix: A Case Report (자궁경부 위형 점액샘암종의 위 전이: 증례 보고)

  • Min Hye Kim;Kyeong Ah Kim;Yi Kyeong Chun;Jeong Woo Kim;Jongmee Lee;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.445-450
    • /
    • 2024
  • Gastric metastasis (GM) from cervical cancer is extremely rare, and only a few cases have been reported in the English literature. Gastric-type mucinous adenocarcinomas (GAS) of the uterine cervix are rare. GAS is an aggressive cancer commonly found in advanced stages; however, GM has not been reported. This study presents a rare case of GM from GAS of the uterine cervix in a 61-year-old female and describes the radiological findings of both the GM and cervical mucinous adenocarcinoma. GM appeared as a poor enhancing submucosal mass. The cervical mucinous adenocarcinoma appeared as an infiltrating mass with poor contrast enhancement. It exhibited mildly high and low signal intensities on the diffusion-weighted image and apparent diffusion coefficient map, respectively. This case is extremely rare and challenging to diagnose; however, if cervical cancer is an human papillomavirus-independent GAS type and a submucosal lesion is found in the stomach, the possibility of metastasis with a pattern similar to our case could be considered.

Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

  • Dong Wook Kim;Jiyeon Ha;Yousun Ko;Kyung Won Kim;Taeyong Park;Jeongjin Lee;Myung-Won You;Kwon-Ha Yoon;Ji Yong Park;Young Jin Kee;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.624-633
    • /
    • 2021
  • Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2-4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings. Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30-150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0-44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used. Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

Prediction of Patient Management in COVID-19 Using Deep Learning-Based Fully Automated Extraction of Cardiothoracic CT Metrics and Laboratory Findings

  • Thomas Weikert;Saikiran Rapaka;Sasa Grbic;Thomas Re;Shikha Chaganti;David J. Winkel;Constantin Anastasopoulos;Tilo Niemann;Benedikt J. Wiggli;Jens Bremerich;Raphael Twerenbold;Gregor Sommer;Dorin Comaniciu;Alexander W. Sauter
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.994-1004
    • /
    • 2021
  • Objective: To extract pulmonary and cardiovascular metrics from chest CTs of patients with coronavirus disease 2019 (COVID-19) using a fully automated deep learning-based approach and assess their potential to predict patient management. Materials and Methods: All initial chest CTs of patients who tested positive for severe acute respiratory syndrome coronavirus 2 at our emergency department between March 25 and April 25, 2020, were identified (n = 120). Three patient management groups were defined: group 1 (outpatient), group 2 (general ward), and group 3 (intensive care unit [ICU]). Multiple pulmonary and cardiovascular metrics were extracted from the chest CT images using deep learning. Additionally, six laboratory findings indicating inflammation and cellular damage were considered. Differences in CT metrics, laboratory findings, and demographics between the patient management groups were assessed. The potential of these parameters to predict patients' needs for intensive care (yes/no) was analyzed using logistic regression and receiver operating characteristic curves. Internal and external validity were assessed using 109 independent chest CT scans. Results: While demographic parameters alone (sex and age) were not sufficient to predict ICU management status, both CT metrics alone (including both pulmonary and cardiovascular metrics; area under the curve [AUC] = 0.88; 95% confidence interval [CI] = 0.79-0.97) and laboratory findings alone (C-reactive protein, lactate dehydrogenase, white blood cell count, and albumin; AUC = 0.86; 95% CI = 0.77-0.94) were good classifiers. Excellent performance was achieved by a combination of demographic parameters, CT metrics, and laboratory findings (AUC = 0.91; 95% CI = 0.85-0.98). Application of a model that combined both pulmonary CT metrics and demographic parameters on a dataset from another hospital indicated its external validity (AUC = 0.77; 95% CI = 0.66-0.88). Conclusion: Chest CT of patients with COVID-19 contains valuable information that can be accessed using automated image analysis. These metrics are useful for the prediction of patient management.

Primary Invasive Mucinous Adenocarcinoma of the Lung: Prognostic Value of CT Imaging Features Combined with Clinical Factors

  • Tingting Wang;Yang Yang;Xinyue Liu;Jiajun Deng;Junqi Wu;Likun Hou;Chunyan Wu;Yunlang She;Xiwen Sun;Dong Xie;Chang Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.652-662
    • /
    • 2021
  • Objective: To investigate the association between CT imaging features and survival outcomes in patients with primary invasive mucinous adenocarcinoma (IMA). Materials and Methods: Preoperative CT image findings were consecutively evaluated in 317 patients with resected IMA from January 2011 to December 2015. The association between CT features and long-term survival were assessed by univariate analysis. The independent prognostic factors were identified by the multivariate Cox regression analyses. The survival comparison of IMA patients was investigated using the Kaplan-Meier method and propensity scores. Furthermore, the prognostic impact of CT features was assessed based on different imaging subtypes, and the results were adjusted using the Bonferroni method. Results: The median follow-up time was 52.8 months; the 5-year disease-free survival (DFS) and overall survival rates of resected IMAs were 68.5% and 77.6%, respectively. The univariate analyses of all IMA patients demonstrated that 15 CT imaging features, in addition to the clinicopathologic characteristics, significantly correlated with the recurrence or death of IMA patients. The multivariable analysis revealed that five of them, including imaging subtype (p = 0.002), spiculation (p < 0.001), tumor density (p = 0.008), air bronchogram (p < 0.001), emphysema (p < 0.001), and location (p = 0.029) were independent prognostic factors. The subgroup analysis demonstrated that pneumonic-type IMA had a significantly worse prognosis than solitary-type IMA. Moreover, for solitary-type IMAs, the most independent CT imaging biomarkers were air bronchogram and emphysema with an adjusted p value less than 0.05; for pneumonic-type IMA, the tumors with mixed consolidation and ground-glass opacity were associated with a longer DFS (adjusted p = 0.012). Conclusion: CT imaging features characteristic of IMA may provide prognostic information and individual risk assessment in addition to the recognized clinical predictors.

Usefulness of Customized Cervical Spine Immobilizer in Head & Neck Image-Guided Radiation Therapy with Tomotherapy® (토모테라피를 이용한 두경부암 영상유도 방사선 치료 시 개인별 경추고정용구의 유용성 평가)

  • Jin, Sung Eun;Chang, Se Wuk;Choi, Jung Hoan;Kim, Min Joo;Ahn, Seung Kwon;Lee, Sang Kyu;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.65-71
    • /
    • 2018
  • Purpose : Standardized pillow may not support patient's individual cervical spine thoroughly when head and neck radiation therapy with $Tomotherapy^{(R)}$. Therefore, the purpose of this study was to make a comparative analysis for the difference of using standardized pillow only and using customized cervical spine immobilizer with standardized pillow. Materials and Methos : The head and neck cancer patients who are treated image-guided radiation therapy(IGRT) with $Tomotherapy^{(R)}$ were divided into two groups, 20 patients using standardized pillow only, and 20 patients using customized cervical spine immobilizer with standardized pillow. We achieved 20 mega-voltage computed tomography(MVCT) image per patient, compared curvature of the cervical spine in MVCT with curvature of the cervical spine in CT-simulation. Results : Results of comparative analysis were curvature consistency 95.9 %, maximum error of distance 41.9 mm, average distance error per fractionation 19.4 mm, average standard deviation 1.34 mm in case of using standardized pillow only, curvature consistency 98.9 %, maximum error of distance 12.9 mm, average distance error per fractionation 5.8 mm, average standard deviation 0.59 mm in case of using customized cervical spine immobilizer with standardized pillow. Conclusion : Using customized cervical spine immobilizer shows higher reproducibility and low distance error, therefore customized cervical spine immobilizer could be useful for head and neck cancer patients who need radiation therapy.

  • PDF

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Evaluation of HalcyonTM Fast kV CBCT effectiveness in radiation therapy in cervical cancer patients of childbearing age who performed ovarian transposition (난소전위술을 시행한 가임기 여성의 자궁경부암 방사선치료 시 난소선량 감소를 위한 HalcyonTM Fast kV CBCT의 유용성 평가 : Phantom study)

  • Lee Sung Jae;Shin Chung Hun;Choi So Young;Lee Dong Hyeong;Yoo Soon Mi;Song Heung Gwon;Yoon In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.73-82
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of reducing the absorbed dose to the ovaries and the quality of the CBCT image when using the HalcyonTM Fast kV CBCT of cervical cancer patients of child-bearing age who performed ovarian transposition Materials and Methods : Contouring of the cervix and ovaries required for measurement was performed on the computed tomography images of the human phantom (Alderson Rando Phantom, USA), and three Optically Stimulated Luminescence Dosimeter(OSLD) were attached to the selected organ cross-section, respectively. In order to measure the absorbed dose to the cervix and ovaries in the TruebeamTM pelvis mode (Hereinafter referred to as TP), The HalcyonTM Pelvis mode (Hereinafter referred to as HP) and The HalcyonTM Pelvis Fast mode (Hereinafter referred to as HPF), An image was taken with a scan range of 17.5 cm and also taken an image that reduced the Scan range to 12.5cm. A total of 10 cumulative doses were summed, It was replaced with a value of 23 Fx, the number of cervical cancer treatments, and compared In additon, uniformity, low contrast visibility, spatial resolution, and geometric distortion were compared and analyzed using Catphan 504 phantom to compare CBCT image quality between equipment. Each factor was repeatedly measured three times, and the average value was obtained by analysing with the Doselab (Mobius Medical Systems, LP. Versions: 6.8) program. Results: As a result of measuring absorbed dose by CBCT with OSLD, TP and HP did not obtain significant results under the same conditions. The mode showing the greatest reduction value was HPF versus TP. In HPF, the absorbed dose was reduced by 39.8% in the cervix and 19.8% in the ovary compared to the TP in the scan range of 17.5 cm. the scan range was reduced to 12.5 cm, absorbed dose was reduced by 34.2% in the cervix and 50.5% in the ovary. In addition, result of evaluating the quality of the image used in the above experiment, it complied with the equipment manufacturer's standards with Geometric Distortion within 1mm (SBRT standard), Uniformity HU, LCV within 2.0%, Spatial Resolution more than 3 lp/mm. Conclusion: According to the results of this experiment, HalcyonTM can select more various conditions than TruebeamTM in treatment of fertility woman who have undergone ovarian Transposition , because it is important to reduce the radiation dose by CBCT during radiation therapy. So finally we recommend HalcyonTM Fast kV CBCT which maintains image quality even at low mAs. However, it is consider that the additional exposure to low doses can be reduced by controlling the imaging range for patients who have undergone ovarian transposition in other treatment machines.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF