• 제목/요약/키워드: computed tomography image

검색결과 976건 처리시간 0.026초

Relationship of the maxillary posterior teeth and maxillary sinus floor in different skeletal growth patterns: A cone-beam computed tomographic study of 1600 roots

  • Shrestha, Biken;Shrestha, Rachana;Lu, Hongfei;Mai, Zhihui;Chen, Lin;Chen, Zheng;Ai, Hong
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.19-25
    • /
    • 2022
  • Purpose: This study evaluated the distance from the posterior root apices to the maxillary sinus floor (MSF) and the frequency of roots touching or protruding through the MSF using cone-beam computed tomography (CBCT). Materials and Methods: This study included 100 subjects divided into different vertical and anteroposterior skeletal growth patterns. On CBCT images, the distance from the posterior root apices to MSF was measured and the frequency of roots touching or protruding through the MSF was evaluated using NNT software (version 5.3.0.0; ImageWorks, Elmsford, NY, USA). Results: No statistically significant differences were found in the distance from the posterior root apices to the MSF among vertical skeletal groups (P>0.05). The palatal roots of the first molar and the palatal, mesio-buccal and disto-buccal roots of the second molars had significantly less distance from MSF in skeletal class II than in class III (P<0.05). The high-angle group had the highest frequencies of roots touching or protruding into the maxillary sinus (49.8%); the lowest proportion of these roots was found in skeletal class III (28.3%) and the highest proportion in class II (50.3%). Males had shorter distances from the posterior root apices to the MSF and higher frequencies of roots protruding through or touching the MSF than females. Conclusion: Anteroposterior skeletal growth patterns and sex affected the distances from the maxillary posterior roots to the MSF. The frequency of roots protruding into or touching the sinus was affected by both vertical and anteroposterior skeletal groups and sex. These findings have implications for dental practice.

Cone-beam computed tomographic evaluation of the root canal anatomy of the lower premolars and molars in a Brazilian sub-population

  • Jessica Cecilia Almeida;Amanda Pelegrin Candemil;Gunther Ricardo Bertolini;Aline Evangelista Souza-Gabriel;Antonio Miranda Cruz-Filho;Manoel Damiao Sousa-Neto;Ricardo Gariba Silva
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.77-82
    • /
    • 2023
  • Purpose: This study evaluated anatomical variations in the root canals of the lower premolars and molars in a Brazilian sub-population using cone-beam computed tomography (CBCT). Materials and Methods: In total, 121 CBCT images of patients were selected from a database. All images contained lower first and second premolars and molars on both sides of the arch, fully developed roots, and no treatment, resorption, or calcifications. In each image, the root canals of the lower premolars and molars were evaluated according to the Vertucci classification in On-Demand 3D software in the multiplanar reconstruction with dynamic navigation. Twenty-five percent of the images were re-assessed to analyze intraobserver confidence with the kappa test. Data were statistically evaluated with linear regression to evaluate the correlations of anatomic variations with age and sex, and the Wilcoxon test to analyze the laterality of variations, with a significance level of 5%. Results: The intraobserver agreement (0.94) was excellent. In general, the root canals of lower premolars and molars showed a higher prevalence of type I than other Vertucci classification types, followed by type V in premolars and type II in molars. When the molar roots were evaluated separately, type II was more frequent in mesial roots and type I in distal roots. Although age showed no correlations with the results, sex and laterality showed correlations with tooth 45 and the lower second premolars, respectively. Conclusion: The lower premolars and molars of a Brazilian sub-population showed a wide range of root canal anatomic variations.

Observation of reinforcing fibers in concrete upon bending failure by X-ray computed tomographic imaging

  • Seok Yong Lim;Kwang Soo Youm;Kwang Yeom Kim;Yong-Hoon Byun;Young K. Ju;Tae Sup Yun
    • Computers and Concrete
    • /
    • 제31권5호
    • /
    • pp.433-442
    • /
    • 2023
  • This study presents the visually observed behavior of fibers embedded in concrete samples that were subjected to a flexural bending test. Three types of fibers such as macro polypropylene, macro polyethylene, and the hybrid of steel and polyvinyl alcohol were mixed with cement by a designated mix ratio to prepare a total of nine specimens of each. The bending test was conducted by following ASTM C1609 with a net deflection of 2, 4, and 7 mm. The X-ray computed tomography (XCT) was carried out for 7 mm-deflection specimens. The original XCT images were post-processed to denoise the beam-hardening effect. Then, fiber, crack, and void were semi-manually segmented. The hybrid specimen showed the highest toughness compared to the other two types. Debonding based on 2D XCT sliced images was commonly observed for all three groups. The cement matrix near the crack surface often involved partially localized breakage in conjunction with debonding. The pullout was predominant for steel fibers that were partially slipped toward the crack. Crack bridging and rupture were not found presumably due to the image resolution and the level of energy dissipation for poly-fibers, while the XCT imaging was advantageous in evaluating the distribution and behavior of various fibers upon bending for fiber-reinforced concrete beam elements.

연부조직 종양의 진단적 접근 (Diagnostic Approach to a Soft Tissue Mass)

  • 전영수;송승현
    • 대한정형외과학회지
    • /
    • 제54권4호
    • /
    • pp.293-301
    • /
    • 2019
  • 사지와 몸통의 연부조직 종양은 정형외과 의사가 직면할 수 있는 흔한 문제이다. 비록 연부조직 종양은 대부분 양성이지만 정형외과 의사는 양성과 악성 종양을 구별할 수 있는 특징을 알고 있어야 한다. 연부조직 종양의 임상적 특징 및 역학을 이해하게 되면 올바른 진단 및 수술적인 치료를 할 수 있게 된다. 종양의 크기와 깊이는 종양의 진단을 위해 가장 중요한 요소이다. 종양의 감별 진단을 하기 위해서 우선적으로 상세한 병력청취와 자세한 신체 검사가 필요하며, 이후 단순 방사선 촬영, 초음파, 자기공명영상(magnetic resonance imaging), 양전자 방출 단층촬영술(positron emission tomography), 컴퓨터 단층촬영(computed tomography), 뼈 스캔, 혈관 조영술 등의 다양한 영상 촬영법을 사용하여 종양을 진단하고 진단된 종양의 특성을 확인하여야 한다. 특히 초음파 검사는 외래에서도 쉽게 수행할 수 있어 유용하다. 그러나 검사자의 숙련도에 따라 검사 정확도의 차이가 발생할 수 있다는 단점이 있다. 종양의 생검을 통한 조직검사는 종양에 대한 모든 영상 검사를 시행한 후 최종적으로 시행하는 것이 원칙이다. 조직 검사를 시행할 때는 세심한 주의를 기울여야 하며, 최종적인 진단 후에는 치료를 위해 다각적인 접근을 시행하여야 하며 필요한 경우에는 경험 있는 근골격계 종양전문의사에게 의뢰하는 것이 필요하다.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.

전산화단층상을 이용한 안면골의 3차원재구성상의 비교 연구 (COMPARATIVE STUDY OF THREE-DIMENSIONAL RECONSTRUCTIVE IMAGES OF FACIAL BONE USING COMPUTED TOMOGRAPHY)

  • 송남규;고광준
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.283-290
    • /
    • 1992
  • The purpose of this study was to evaluate the spatial relationship of facial bone more accurately. For this study, the three-dimensional images of dry skull were reconstructed using computer image analysis system and three-dimensional reconstructive program involved CT. The obtained results were as follows: 1. Three-dimensional reconstructive CT results in images that have better resolution and more contrast 2. It showed good marginal images of anatomical structure on both three-dimensional CT and computer image analysis system, but the roof of orbit, the lacrimal bone and the squamous portion of temporal bone were hardly detectable. 3. The partial loss of image data were observed during the regeneration of saved image data on three-dimensional CT. 4. It saved the more time for reconstruction of three-dimensional images using computer image analysis system. But, the capacity of hardware was limited for inputting of image data and three-dimensional reconstructive process. 5. We could observe the spatial relationship between the region of interest and the surrounding structures by three-dimensional reconstructive images without invasive method.

  • PDF

Compression and Enhancement of Medical Images Using Opposition Based Harmony Search Algorithm

  • Haridoss, Rekha;Punniyakodi, Samundiswary
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.288-304
    • /
    • 2019
  • The growth of telemedicine-based wireless communication for images-magnetic resonance imaging (MRI) and computed tomography (CT)-leads to the necessity of learning the concept of image compression. Over the years, the transform based and spatial based compression techniques have attracted many types of researches and achieve better results at the cost of high computational complexity. In order to overcome this, the optimization techniques are considered with the existing image compression techniques. However, it fails to preserve the original content of the diagnostic information and cause artifacts at high compression ratio. In this paper, the concept of histogram based multilevel thresholding (HMT) using entropy is appended with the optimization algorithm to compress the medical images effectively. However, the method becomes time consuming during the measurement of the randomness from the image pixel group and not suitable for medical applications. Hence, an attempt has been made in this paper to develop an HMT based image compression by utilizing the opposition based improved harmony search algorithm (OIHSA) as an optimization technique along with the entropy. Further, the enhancement of the significant information present in the medical images are improved by the proper selection of entropy and the number of thresholds chosen to reconstruct the compressed image.

전산화단층촬영에서 관전압과 관전류, 통계적 반복재구성법에 따른 화질과 피폭선량 (Quality of Image and Exposure Dose According to kVp, mA and Iterative Reconstruction in Computed Tomography)

  • 차상영;박재윤;이용기;김정훈;최재호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.385-392
    • /
    • 2017
  • 본 연구는 전산화단층촬영에서 관전압과 관전류에 따른 화질과 피폭선량을 연구하고 None IR과 IR (Iterative Reconstruction)의 단계에 따른 영상의 SNR(Signal to Noise Ratio)을 비교하여 영상 화질의 개선정도에 대하여 확인해보고자 하였다. Image J를 이용하여 화질을 측정한 결과 관전압의 증가에 따라 HU (Hounsfield units)와 BN(Background Noise)은 감소하였으며, 이와 반대로 SI (Signal Intensity)와 SNR, $CTDI_{vol}$ (CT dose in dex volume)은 관전압이 높아질수록 증가하였으며, BHU(Background Hounsfield Units)의 변화는 없었다. 관전류의 증가로 인해서 BN이 감소하였고, 반대로 SNR과 CTDI은 증가하였다. 또한 IR의 단계가 높아질수록 HU와 SI, BN이 낮아지고, SNR이 약 10~60% 향상됨을 알 수 있었다. 이를 토대로 임상에서 IR 적용 시 단계적 접근 방식으로 관전압과 관전류를 미세 조정하여 점차적으로 방사선량을 줄여 나가야 할 것이다.

흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구 (A Phantom Study for the Optimal Low-dose Protocol in Chest Computed Tomography Examination)

  • 김영근;양숙;왕태욱;김은혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권2호
    • /
    • pp.101-107
    • /
    • 2021
  • The purpose of this study was to evaluate optimal CT scan parameters to minimize patient dose to the irradiation and maintain satisfactory image quality in low-dose chest computed tomography (CT) scans. In a chest anthropomorphic phantom, chest CT scans were performed at different kVp and mA within reference of 3.4mGy in volume CT Dose Index (CTDIvol). The following quantitative parameters had been statistically evaluated: image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM). Nine radiographers conducted the blind test to select the optimal kVp-mA combination. Results indicated that the kVp-mA combination of 80kVp-90mA, 100kVp-50mA, 120kVp-30mA and 140kVp-30mA were obtained high SNR and CNR. The 120kVp-30mA combination offered good compromise in the FOM, which showed the quality and dose performance. In the blind test, an image of 80kVp-90mA obtained a high score with 4.7 points, and 120kVp-10mA or 140kVp-10mA with a low tube current were observed severe noise and poor image quality, thus resulting in decreased diagnostic accuracy. On the other hand, in the combination of high kVp and high mA(140kVp-90mA), the image quality was improved, but the radiation dose was also increased. the FOM value of 140kVp-90mA was lower than 120kVp-30mA. The application of appropriate scan parameters in low-dose chest CT scans produced satisfactory results in dose and image quality for the accuracy of the clinical diagnosis.

딥러닝을 이용한 화강암 X-ray CT 영상에서의 균열 검출에 관한 연구 (Pixel-level Crack Detection in X-ray Computed Tomography Image of Granite using Deep Learning)

  • 현석환;이준성;전성환;김예진;김광염;윤태섭
    • 터널과지하공간
    • /
    • 제29권3호
    • /
    • pp.184-196
    • /
    • 2019
  • 본 연구에서는 화강암 시편에서 수압 파쇄법에 의해 생성된 미세균열의 3차원 형상을 X-ray CT 영상과 딥러닝을 이용하여 추출하였다. 실험으로 생성된 미세균열은 X-ray CT 영상 상에서 일반적인 영상처리방법으로는 추출하기 매우 어렵고 육안으로만 관찰이 가능한 형태를 지닌다. 하지만 본 연구에서 제안한 합성곱 신경망(Convolutional neural network) 기반 인코더-디코더(Encoder-Decoder) 구조의 딥러닝 모델을 통해 미세균열을 정량적으로 추출할 수 있었다. 특히 픽셀 단위의 미세균열 추출을 위해 인코딩 과정에서 소실되는 정보를 디코딩 과정으로 직접 전달하는 디코더 모델을 제안하였다. 또한, 딥러닝 기반 신경망 학습에 필요한 데이터의 수를 증가시키기 위해 이미지의 분할(Division), 회전(Rotation), 그리고 반전(Flipping) 등으로 데이터를 생성하는 영상 증대 방법을 적용하였으며 이때 최적의 조합을 확인하였다. 최적의 영상 학습 데이터 증대 방법을 적용하였을 때 검증 데이터뿐만 아니라 테스트 데이터에서의 성능 향상을 확인하였다. 학습 데이터의 원본 개수가 딥러닝 기반 신경망의 균열 추출 성능에 미치는 영향을 확인하고 딥러닝 기술을 사용하여 성공적으로 미세균열을 추출하였다.