• Title/Summary/Keyword: computed tomography image

Search Result 966, Processing Time 0.024 seconds

A Study on the Fast Image Reconstruction Algorithm for Spiral CT (Spiral CT의 고속 영상재구성 알고리즘에 관한 연구)

  • Heo, Chang-Won;Jin, Seung-Oh;Lee, Jae-Duck;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3207-3209
    • /
    • 2000
  • X-ray CT(Computed Tomography) has been a good modality for non-invasive diagnosis and recently, Conventional CT has been replaced rapidly with Spiral CT in recent. In X-ray CT, spiral scanning has various advantages such as better image quality, reduced scan time (in a single breath-hold), a lower x-ray dose. But, it requires very fast and high performance image processing system to reconstruct slice images from spiral scanning. This paper describes the fast image reconstruction techniques with filtered back projection from the viewpoints of fast algorithm as well as hardware implementation for real-time imaging.

  • PDF

A Study on the Skull Injury Using MDCT image and ADINA F.E.M. Program (MDCT 영상과 ADINA 유한요소해석 프로그램을 활용한 두개골 손상 평가에 관한 연구)

  • Kim, Eui Soo;Kim, Jong Hyuk;Yang, Kyung Moo
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • In this paper, the finite element analysis using ADINA has performed to investigate an accident that a man's head was damaged by the falling object. The simulation condition has defined by the point of forensic medicine view and the CCTV image analysis. From the CCTV image analysis, we expected that the sphere diameter of object is 15cm and object color is white. Assuming the falling mass is the ice mass, the results of the ADINA simulation show that a man's head can be broken by the falling ice mass.

In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review

  • Chang, Seok-Woo;Lee, Jong-Ki;Lee, Yoon;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.2-10
    • /
    • 2013
  • A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.

A Preoperative Marking Template for Deep Inferior Epigastric Artery Perforator Flap Perforators in Breast Reconstruction

  • Miranda, Benjamin H.;Pywell, Matthew;Floyd, David
    • Archives of Plastic Surgery
    • /
    • v.41 no.2
    • /
    • pp.171-173
    • /
    • 2014
  • Preoperative perforator marking for deep inferior epigastric artery perforator flaps is vital to the success of the procedure in breast reconstruction. Advances in imaging have facilitated accurate identification and preselection of potentially useful perforators. However, the reported imaging accuracy may be lost when preoperatively marking the patient, due to 'mapping errors', as this relies on the use of 2 reported vectors from a landmark such as the umbilicus. Observation errors have been encountered where inaccurate perforator vector measurements have been reported in relation to the umbilicus. Transcription errors have been noted where confusing and wordy reports have been typed or where incorrect units have been given (millimetres vs. centimetres). Interpretation errors have also occurred when using the report for preoperative marking. Furthermore, the marking process may be unnecessarily time-consuming. We describe a bespoke template, created using an individual computed tomography angiography image, that increases the efficiency and accuracy of preoperative marking. The template is created to scale, is individually tailored to the patient, and is particularly useful in cases where multiple potential suitable perforators exist.

Endodontic management of a mandibular second molar with radix entomolaris: a case report

  • Hannah, Rosaline;Kandaswamy, Deivanayagam;Jayaprakash, Nachimuthu
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.2
    • /
    • pp.132-136
    • /
    • 2014
  • The presence of radix entomolaris (RE) in a mandibular first molar is a common occurrence in certain ethnic groups, but the presence of RE in a mandibular second molar is a rare occurrence. In the present case, RE was identified from preoperative radiographs and confirmed using cone-beam computed tomography (CBCT). The access cavity was modified to locate the RE. Cleaning and shaping were performed with nickel-titanium rotary instruments. Obturation was completed with gutta-percha cones using AH Plus (Dentsply Detrey GmbH) as sealer. From the CBCT axial images, the RE was determined to have a Type III curvature by the De Moor classification, Type B separate RE by the Carlsen and Alexandersen classification, and radiographically, a Type i image by the Wang classification. The presence of RE in the mandibular second molar makes it essential to anticipate and treat the distolingual root canal. This case report highlights the usefulness of CBCT for assessing RE in the mandibular second molar, which can help the clinician in making a confirmatory diagnosis and assessing the morphology of the root canal.

Endodontic management of a C-shaped maxillary first molar with three independent buccal root canals by using cone-beam computed tomography

  • Karanxha, Lorena;Kim, Hee-Jin;Hong, Sung-Ok;Lee, Wan;Kim, Pyung-Sik;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.175-179
    • /
    • 2012
  • The aim of this study was to present a method for endodontic management of a maxillary first molar with unusual C-shaped morphology of the buccal root verified by cone-beam computed tomography (CBCT) images. This rare anatomical variation was confirmed using CBCT, and nonsurgical endodontic treatment was performed by meticulous evaluation of the pulpal floor. Posttreatment image revealed 3 independent canals in the buccal root obturated efficiently to the accepted lengths in all 3 canals. Our study describes a unique C-shaped variation of the root canal system in a maxillary first molar, involving the 3 buccal canals. In addition, our study highlights the usefulness of CBCT imaging for accurate diagnosis and management of this unusual canal morphology.

Analysis on Setup Variation According to Megavoltage Computed Tomography System

  • Kim, Sun-Yung;Kim, Hwa-Sun;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.425-430
    • /
    • 2016
  • The aim of this study was to measure the setup variation for X (lateral), Y (longitude), and Z (vertical) by taking magnetic megavoltage computed tomography (MVCT) before treating the brain, oropharynx, lung, and prostate patients on helical tomotherapy. In this study, 30 patients were chosen for each of the treatment areas, and their skin was labeled with a mark on a treatment planning reference point when taking CT. We preceded MVCT prior to tomotherapy and then conducted an auto registration based on the bony landmarks; image registration was used for automatically matching the patient's setup. Lastly, we confirmed and evaluated the translation coordinates of the images for 30 patients. The following shows the comparison result of the setup errors of each part: X (lateral) showed the highest setup errors with $3.44{\pm}2.05$ from Lung; Y (longitude) showed the highest setup errors showing $3.40{\pm}2.87mm$ from Prostate; and Z (vertical) showed the highest setup errors showing $6.62{\pm}4.38mm$ from Lung. This result verifies that the setup error can be prevented by taking MVCT before the treatment, and Planning Target Volume (PTV) margins can be reduced by referring to the resulting value of each treatment part. Ultimately, the dosage of the normal organs can be decreased as well as any side effects.

Choice of Thresholding Technique in Micro-CT Images of Trabecular Bone Does Not Influence the Prediction of Bone Volume Fraction and Apparent Modulus

  • Kim, Chi-Hyun;Kim, Byung-Gwan;Guo, X. Edward
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.174-177
    • /
    • 2007
  • Trabecular bone can be accurately represented using image-based finite element modeling and analysis of these bone models is widely used to predict their mechanical properties. However, the choice of thresholding technique, a necessary step in converting grayscale images to finite element models which can thus significantly influence the structure of the resulting finite element model, is often overlooked. Therefore, we investigated the effects of thresholding techniques on micro-computed tomography (micro-CT) based finite element models of trabecular bone. Three types of thresholding techniques were applied to micro-CT images of trabecular bone which resulted in three unique finite element models for each specimen. Bone volume fractions and apparent moduli were predicted for each model and compared to experimental results. Our findings suggest that predictions of apparent properties agree well with experimental measurements regardless of the choice of thresholding technique in micro CT images of trabecular bone.

Quantitative evaluation of iterative reconstruction algorithm for high quality computed tomography image acquisition with low dose radiation : Comparison with filtered back projection algorithm (저선량.고화질 CT 영상 획득을 위한 반복적 재구성 기법의 정량적 평가 : 필터보정 역투영법과의 비교 분석)

  • Ha, Seongmin;Shim, Hackjoon;Chang, Hyuk-Jae;Kim, Seonkyu
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2013.06a
    • /
    • pp.274-277
    • /
    • 2013
  • CT(Computed Tomography)영상에서 선량과 화질은 중요한 요소이다. 선량은 환자에게 직접적으로 악영향을 끼치는 요소이며, 화질은 환자의 병변을 판단하는데 매우 중요하게 작용한다. 반복적 재구성 알고리즘을 이용하면 저선량 영상에서도 고화질의 영상을 얻을 수 있는지 FBP와 정량적, 정성적으로 비교하였다. 촬영 프로토콜은 관전압 80, 100, 120kVp에서 관전류를 동일하게 200mA로 촬영하여 획득하였으며, 정량적 평가를 위해 SD(Standard Deviation), SNR(Signal to Noise Ratio), MTF(Modulation Transfer Function)를 측정하여 분석하였다. 선량은 80kVp일 때 가장 낮았으며, 120kVp일 때 가장 높았다. 80kVp의 영상을 Toshiba 사(社)의 AIDR 3D(Adaptive Iterative Reduction integrated into $^{SURE}Exposure$)로 재구성하고, 120kVp의 영상에 FBP로 재구성한 다음 정량적 비교를 한 결과 AIDR 3D를 적용한 영상의 SD가 낮게 나왔으며, SNR이 높게 나타났고, MTF 곡선은 유사하게 나타났다. 그리고 FWHM(Full Width at Half Maximum) 값의 오차가 거의 없었다. 결론적으로 AIDR 3D는 저선량에서도 높은 화질을 나타냄을 확인하였다.

  • PDF

Synthesis and Biodistribution of Cat's Eye-shaped [57Co]CoO@SiO2 Nanoshell Aqueous Colloids for Single Photon Emission Computed Tomography (SPECT) Imaging Agent

  • Kwon, Minjae;Park, Jeong Hoon;Jang, Beom-Su;Jung, Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2367-2370
    • /
    • 2014
  • "Cat's eye"-shaped $[^{57}Co]CoO@SiO_2$ core-shell nanostructure was prepared by the reverse microemulsion method combined with radioisotope technique to investigate a potential imaging agent for a single photon emission computed tomography (SPECT) in nuclear medicine. The core cobalt oxide nanorods were obtained by thermal decomposition of $Co-(oleate)_2$ precursor from radio isotope Co-57 containing cobalt chloride and sodium oleate. The $SiO_2$ coating on the surface of the core cobalt oxide nanorods was produced by hydrolysis and a condensation reaction of tetraethylorthosilicate (TEOS) in the water phase of the reverse microemulsion system. In vivo test, micro SPECT image was acquired with nude mice after 30 min of intravenous injection of $[^{57}Co]CoO@SiO_2$ core-shell nanostructure.