• Title/Summary/Keyword: computed tomography image

Search Result 972, Processing Time 0.026 seconds

A Study on Correlation between Heterogeneity Index and Mechanical Properties of Igneous Rocks using 3D X-ray Computed Tomography Image (3차원 X-ray CT 영상을 이용한 화성암 불균질 지수와 역학적 특성과의 상관관계에 대한 연구)

  • Jeong, Yeon Jong;Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.333-342
    • /
    • 2017
  • In this study, the heterogeneity of internal structure of various igneous rocks acquired in Korea was quantified and correlated with the seismic velocity and the point load strength. Three-dimensional X-ray Computed Tomography (CT) was used to obtain information on the internal structure of the rock specimen, and the representative unit length (LR) was calculated by applying a statistical technique to the CT images. We also proposed an estimation equation to predict the mechanical properties of rocks from the relationship between LR, acoustic velocity and point load strength. In the proposed method, it is shown that the characterization of internal structure of rocks could be utilized as an indirect index to account for the mechanical behavior of rocks by substituting physical laboratory testing for non-destructive test.

Construction reproducibility of a composite tooth model composed of an intraoral-scanned crown and a cone-beam computed tomography-scanned root

  • Lim, Seung-Weon;Moon, Ryu-Jin;Kim, Min-Seok;Oh, Min-Hee;Lee, Kyung-Min;Hwang, Hyeon-Shik;Kim, Tae-Woo;Baek, Seung-Hak;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.229-237
    • /
    • 2020
  • Objective: To evaluate the construction reproducibility of a composite tooth model (CTM) composed of an intraoral-scanned crown and a cone-beam computed tomography (CBCT)-scanned root. Methods: The study assessed 240 teeth (30 central incisors, 30 canines, 30 second premolars, and 30 first molars in the maxillary and mandibular arches) from 15 young adult patients whose pre-treatment intraoral scan and CBCT were available. Examiner-Reference (3 years' experience in CTM construction) and Examiners-A and Examiner-B (no experience) constructed the individual CTMs independently by performing the following steps: image acquisition and processing into a three-dimensional model, integration of intraoral-scanned crowns and CBCT-scanned teeth, and replacement of the CBCT-scanned crown with the intraoral-scanned crown. The tooth axis angle in terms of mesiodistal angulation and buccolingual inclination of the CTMs constructed by the three examiners were measured. To assess the construction reproducibility of CTMs, intraclass correlation coefficient (ICC) assessments were performed. Results: The ICC values of mesiodistal angulation and buccolingual inclination among the 3 examiners showed excellent agreement (0.950-0.992 and 0.965-0.993; 0.976-0.994 and 0.973-0.995 in the maxillary and mandibular arches, respectively). Conclusions: The CTM showed excellent construction reproducibility in mesiodistal angulation and buccolingual inclination regardless of the construction skill and experience levels of the examiners.

Morphological analysis of maxillary sinus septum using computed tomography (컴퓨터단층촬영을 이용한 상악동 중격의 형태학적 분석)

  • Chae, Jong-Beom;Lee, Sang-Han;Kim, Chin-Soo;Kim, Jong-Bae;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.36-42
    • /
    • 2011
  • Introduction: The current study examined the morphological characteristics of maxillary sinus septum by computed tomography (CT). Materials and Methods: Two hundred and four patients (408 maxillary sinuses) who visited dental clinic were evaluated. CT were examined. The height of the septum measured from the sinus floor to the apex of the septum more than 3 mm was defined as "sinus septum". Results: The prevalence of sinus septa was 21.3% (87/408), and 31.4% (64/204) of patients had more than 1 sinus septum. Females showed higher and thinner sinus septa than males. The anatomic location of the septa were distributed in the 2nd molar region (43.7%), 1st molar region (31.0%), 2nd premolar region (21.8%) and 1st premolar region (3.5%). In 57 patients with chronic disease, there was no significant difference between sinus disease and the presence of sinus septa. The loss of remaining teeth and teeth adjacent to the sinus septum area was not related to the presence of sinus septa. Older subjects showed a reduced height and length of the septum, and a thicker septum. Conclusion: These results show that the maxillary sinus septum undergoes atrophy with age.

The Value of Preoperative Multidetector Computed Tomography for Deep Inferior Epigastric Artery Perforator Free Flap (심하복벽동맥 천공지 유리피판에서 술전 MDCT의 유용성)

  • Heo, Chan Yeong;Hong, Ki Yong;Yoon, Chang Jin;Eun, Seok Chan;Baek, Rong Min;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.140-146
    • /
    • 2009
  • Purpose: Autologous breast reconstruction with abdominal tissue is one of the best options after mastectomy. In a free transverse rectus abdominis myocutaneous(TRAM) or deep inferior epigastric artery perforator(DIEP) flap, a preoperative evaluation of the precise location of perforating vessels and vascular run - off systems is required. The objective of this report is to demonstrate the usefulness of multidetector computed tomography(MDCT) in the preoperative planning of patients undergoing breast reconstruction with abdominal flap. Methods: From June 2006 to January 2008, 28 patients underwent MDCT evaluation before breast reconstruction. All subjects were females with an age range of 30 to 55 years. The CT scan was performed using a 64 - slice MDCT scanner(Brilliance 64; Philips Medical Systems, Best, Netherlands). Results: One perforator or two major perforators were marked on image in good relation with a hand - held Doppler examination and intraoperative findings. All vascular run - off systems were cleared before operation. Conclusion: Preoperative evaluation of perforator arteries with MDCT angiography is beneficial in patients undergoing breast reconstruction. This technique provides a noninvasive approach of the vascular anatomy of the entire anterior abdominal wall.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.45 no.4
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

Anatomy and morphology of the nasopalatine canal using cone-beam computed tomography

  • Thakur, Arpita Rai;Burde, Krishna;Guttal, Kruthika;Naikmasur, Venkatesh G.
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.273-281
    • /
    • 2013
  • Purpose: This study was performed to evaluate the general anatomy and morphology of the nasopalatine canal using cone-beam computed tomography (CBCT) and to determine the human anatomic variability of the nasopalatine canal in relation to age and gender. Materials and Methods: The study included 100 subjects aged between 20 and 86 years who were divided into the following 3 groups: 1) 20-34 years old; 2) 35-49 years old; 3) ${\geq}50$ years old. The subjects were equally distributed between the genders. CBCT was performed using a standard exposure and patient positioning protocol. The data of the CBCT images were sliced in three dimensions. Image planes on the three axes (X, Y, and Z) were sequentially analyzed for the location, morphology and dimensions of the nasopalatine canal by two independent observers. The correlation of age and gender with all the variables was evaluated. Results: The present study did not reveal statistically significant differences in the number of openings at the nasal fossa; diameter of the nasal fossa openings; diameter of the incisive fossa; shape, curvature, and angulation of the canal as viewed in the sagittal sections; antero-posterior dimensions and length of the canal in the sagittal sections; or the level of division of the canal in the coronal plane by age. However, males and females showed significant differences in the length of the canal in the sagittal sections and level of the division of the canal in the coronal plane. Conclusion: The present study highlighted important variability observed in the anatomy and morphology of the nasopalatine canal.

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

  • Creanga, Adriana Gabriela;Geha, Hassem;Sankar, Vidya;Teixeira, Fabricio B.;McMahan, Clyde Alex;Noujeim, Marcel
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods: Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results: A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion: CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

Radiation absorbed doses of cone beam computed tomography (Cone beam형 전산화단층촬영에 의한 흡수선량)

  • Lee, Eui-Tae;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • Purpose: To measure the absorbed doses of cone beam computed tomography (CBCT), which is recently being more frequently used, and to compare them with those of panoramic radiography. Materials and Methods: To measure the absorbed doses of CBCT ($PSR-9000N^{TM}$, Asahi Roentgen Ind. Co., Japan), we placed TLD chips on the skin regions above the parotid and thyroid glands, and on the dorsum of tongue in a dental head phantom. We used two image acquisition modes of the Dental and Panoramic modes of CBCT, which differed in the field of view. Also, panoramic radiographs (Auto IIIN, Asahi Roentgen Ind. Co., Japan) were taken to compare with the absorbed doses of CBCT. Result: In the Dental mode of CBCT, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 3.53, 3.13, and 0.36 mGy, respectively. In the Panoramic mode of CBCT, they were 9.57, 9.15, and 0.85 mGy, respectively. The panoramic mode showed higher absorbed doses than those of the Dental mode. In the panoramic radiography, the absorbed doses of the parotid gland, dorsum of tongue, and thyroid gland were 1.21, 1.19, and 0.16 mGy, respectively. And they were about 1/3 of the Dental mode and 1/9 of the Panoramic mode of CBCT. Conclusion: Absorbed doses of CBCT are higher than those of panoramic radiography, and dependent upon the field of view.

  • PDF

Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers

  • Hu, Kyung-Seok;Choi, Da-Yae;Lee, Won-Jae;Kim, Hee-Jin;Jung, Ui-Won;Kim, Sung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • Purpose: Special care is necessary to avoid invading important anatomic structures during surgery when presurgical planning is made based on radiographs. However, none of these types of radiography represents a perfect modality. The purpose of this study was to determine the reliability of presurgical planning based on the use of two types of radiographic image (digital panoramic radiography [DPR] and cone-beam computed tomography [CBCT]) by beginner dentists to place implants, and to quantify differences in measurements between radiographic images and real specimens. Methods: Ten fresh cadavers without posterior teeth were used, and twelve practitioners who had no experience of implant surgery performed implant surgery after 10 hours of basic instruction using conventional surgical guide based on CBCT or DPR. Two types of measurement error were evaluated: 1) the presurgical measurement error, defined as that between the presurgical and postsurgical measurements in each modality of radiographic analysis, and 2) the measurement error between postsurgical radiography and the real specimen. Results: The mean presurgical measurement error was significantly smaller for CBCT than for DPR in the maxillary region, whereas it did not differ significantly between the two imaging modalities in the mandibular region. The mean measurement error between radiography and real specimens was significantly smaller for CBCT than for DPR in the maxillary region, but did not differ significantly in the mandibular region. Conclusions: Presurgical planning can be performed safely using DPR in the mandible; however, presurgical planning using CBCT is recommended in the maxilla when a structure in a buccolingual location needs to be evaluated because this imaging modality supplies buccolingual information that cannot be obtained from DPR.

Saturated Hydraulic Conductivity of Surface Seals Estimated from Computed Tomography-Measured Porosity (고해상도 X-ray CT 를 이용한 토양표면 피막의 공극율 및 포화수리전도도 측정)

  • Lee, Sang-Soo;Gantzer, C.J.;Thompson, A.L.;Anderson, S.H.;Ketchum, R.A.;Ok, Yong-Sik
    • 한국환경농학회:학술대회논문집
    • /
    • 2011.07a
    • /
    • pp.207-222
    • /
    • 2011
  • Relationships between soil saturated hydraulic conductivity ($K_s$) and porosity (${\phi}$) have been developed over many years; however, use of these relationships for evaluating rain-induced seals is limited mainly because of difficulties in estimating seal pore-size characteristics. The objectives of this study were to evaluate the $K_s$ of soil surface seals over a range of thicknesses, where seal thickness was determined using a High-Resolution-Computed-Tomography (HRCT) scanner, and to investigate relationships between $K_s$ and ${\phi}$ of developing seals in samples with equivalent diameters (e.d.) ${\geq}15\;{\mu}m$. A Mexico silt loam soil was packed to a bulk density (${\rho}_b$) of $1.1\;Mg\;m^{-3}$ in cylinders 160-mm i.d. by 160-mm long and subjected to $61-mm\;h^{-1}$ simulated rainfall having a kinetic energy (KE) of $25\;J\;m^{-2}\;min^{-1}$ for 7.5, 15, 30, and 60 min to create a range in seal development. Thicknesses of the seal layers were determined by analysis of HRCT images of seals. The $K_s$ values of the seals were estimated using an effective $K_s$ value ($K_{s-eff}$). The $K_s-{\phi}$ relationship was described by a Kozeny and Carmen equation, $K_s=B{\phi}^n$; where B and n are empirical constants and n = 31. This approach explained 86% of the variation between $K_s$ and ${\phi}$ within the soil seals. Knowledge of surface seal information and hydraulic conductivity can provide useful information to use in management of sites prone to sealing formation.

  • PDF