• Title/Summary/Keyword: computed tomography contrast media

Search Result 62, Processing Time 0.02 seconds

Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval (초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법)

  • Lim, Jong Bum;Kim, Young Ki;Kim, Sung Woo;Sung, Kyu Wan;Jung, Il;Lee, Chung
    • The Korean Journal of Pain
    • /
    • v.21 no.1
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

Effects of Remote Ischemic Pre-Conditioning to Prevent Contrast-Induced Nephropathy after Intravenous Contrast Medium Injection: A Randomized Controlled Trial

  • Dihia Belabbas;Caroline Koch;Segolene Chaudru;Mathieu Lederlin;Bruno Laviolle;Estelle Le Pabic;Dominique Boulmier;Jean-Francois Heautot;Guillaume Mahe
    • Korean Journal of Radiology
    • /
    • v.21 no.11
    • /
    • pp.1230-1238
    • /
    • 2020
  • Objective: We aimed to assess the effects of remote ischemic pre-conditioning (RIPC) on the incidence of contrast-induced nephropathy (CIN) after an intravenous (IV) or intra-arterial injection of contrast medium (CM) in patient and control groups. Materials and Methods: This prospective, randomized, single-blinded, controlled trial included 26 patients who were hospitalized for the evaluation of the feasibility of transcatheter aortic valve implantation and underwent investigations including contrast-enhanced computed tomography (CT), with Mehran risk scores greater than or equal to six. All the patients underwent four cycles of five minute-blood pressure cuff inflation followed by five minutes of total deflation. In the RIPC group (n = 13), the cuff was inflated to 50 mm Hg above the patient's systolic blood pressure (SBP); in the control group (n = 13), it was inflated to 10 mm Hg below the patient's SBP. The primary endpoint was the occurrence of CIN. Additionally, variation in the serum levels of cystatin C was assessed. Results: One case of CIN was observed in the control group, whereas no cases were detected in the RIPC group (p = 0.48, analysis of 25 patients). Mean creatinine values at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 88 ± 32 μmol/L, 91 ± 28 μmol/L and 82 ± 29 μmol/L, respectively (p = 0.73) in the RIPC group, whereas in the control group, they were 100 ± 36 μmol/L, 110 ± 36 μmol/L, and 105 ± 34 μmol/L, respectively (p = 0.78). Cystatin C values (median [Q1, Q3]) at the baseline, 24 hours after injection of CM, and 48 hours after injection of CM were 1.10 [1.08, 1.18] mg/L, 1.17 [0.97, 1.35] mg/L, and 1.12 [0.99, 1.24] mg/L, respectively (p = 0.88) in the RIPC group, whereas they were 1.11 [0.97, 1.28] mg/L, 1.13 [1.08, 1.25] mg/L, and 1.16 [1.03, 1.31] mg/L, respectively (p = 0.93), in the control group. Conclusion: The risk of CIN after an IV injection of CM is very low in patients with Mehran risk score greater than or equal to six and even in the patients who are unable to receive preventive hyperhydration. Hence, the Mehran risk score may not be an appropriate method for the estimation of the risk of CIN after IV CM injection.

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Late adverse reactions to iopromide (Ultravist®) diagnosed by the patch test: a case report (첩포검사로 진단된 Iopromide (Ultravist®)의 지연성 부작용 1예)

  • Lee, Soon Joo;Yang, Eun Mi;Choi, Woo Yeon;Song, Eun Song;Han, Dong Kyun;Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.499-503
    • /
    • 2009
  • Iodinated contrast media (CM) can cause immediate and late reactions. We treated a patient with a recurrent generalized maculopapular rash and a fever that occurred within two days of exposure to iodinated CM, iopromide ($Ultravist^{(R)}$), for chest computed tomography. We performed skin testing including prick tests, intradermal tests, and patch tests. Our findings indicated a late skin reaction to $Ultravist^{(R)}$in addition to cross-reactions to other iodinated CM such as ioversol ($Optiray^{(R)}$), iohexol ($Iobrix^{(R)}$), and iobitridol ($Xenetix^{(R)}$). In this study, we report the case of a patient diagnosed with a late adverse reaction to $Ultravist^{(R)}$in addition to cross-reactions to other iodinated CM.

Findings of an Intravenous Catheter Fragment in the Vein Using the 3D Image Reformations of MDCT (정맥내의 IV 카테터 조각의 3D MDCT 재구성 영상)

  • Kweon, Dae-Cheol;Yoo, Beong-Gyu;Yang, Sung-Hwan;Kim, Jeong-Goo
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.167-172
    • /
    • 2006
  • Catheter fragment and embolism are both potentially serious complications associated with the use of an intravenous (IV) catheter for contrast media bolus injection, and may be followed by serious or lethal sequelae. Though catheter fragment is a rare complication of IV catheter insertion, especially in peripheral veins, CT can be used to detect residual fragment. This study demonstrates the utility of MDCT to localize a small, subtle peripheral venous catheter, which can be easily reformatted of MDCT reformations. Various 3D techniques such as MPR and MIP, volume rendering, and shaded-surface displays are currently available for reconstructing MDCT data. Advances in MDCT technology contribute substantially to the detection and accurate localization of smaller IV catheter fragment.

  • PDF

Quantitative Assessment using SNR and CNR in Cerebrovascular Diseases : Focusing on FRE-MRA, CTA Imaging Method (뇌혈관 질환에서 신호대 잡음비와 대조도대 잡음비를 이용한 정량적평가 : FRE-MRA, CTA 영상기법중심으로)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.493-500
    • /
    • 2017
  • In this study, data analysis has been conducted by INFINITT program to analyze the effect of signal to noise ratio(SNR) and contrast to noise ratio(CNR) of flow related enhancement(FRE) and computed tomography Angiography(CTA) on cerebrovascular diseases for qualitative evaluations. Based on the cerebrovascular image results achieved from 63 patients (January to April, 2017, at C University Hospital), we have selected 19 patients that performed both FRE-MRA and CTA. From the 19 patients, 2 were excluded due to artifacts from movements in the cerebrovascular image results. For the analysis conditions, we have set the 5 part (anterior cerebral artery, right and left Middle cerebral artery, right and left Posterior cerebral artery) as the interest area to evaluate the SNR and CNR, and the results were validated through Independence t Test. As a result, by averaging the SNR, and CNR values, the corresponding FRE-MRA achieved were: anterior cerebral artery ($1500.73{\pm}12.23/970.43{\pm}14.55$), right middle cerebral artery ($1470.16{\pm}11.46/919.44{\pm}13.29$), left middle cerebral artery ($1457.48{\pm}17.11/903.96{\pm}14.53$), right posterior cerebral artery ($1385.83{\pm}16.52/852.11{\pm}14.58$), left posterior cerebral artery ($1318.52{\pm}13.49/756.21{\pm}10.88$). by averaging the SNR, and CNR values, the corresponding CTA achieved were: anterior cerebral artery ($159.95{\pm}12.23/123.36{\pm}11.78$), right middle cerebral artery ($236.66{\pm}17.52/202.37{\pm}15.20$), left middle cerebral artery ($224.85{\pm}13.45/193.14{\pm}11.88$), right posterior cerebral artery ($183.65{\pm}13.47/151.44{\pm}11.48$), left posterior cerebral artery ($177.7{\pm}16.72/144.71{\pm}11.43$) (p < 0.05). In conclusion, MRA had high SNR and CNR value regardless of the cerebral infarction or cerebral hemorrhage observed in the 5 part of the brain. Although FRE-MRA consumed longer time, it proved to have less side effect of contrast media when compared to the CTA.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

A Study on the Use of Contrast Agent and the Improvement of Body Part Classification Performance through Deep Learning-Based CT Scan Reconstruction (딥러닝 기반 CT 스캔 재구성을 통한 조영제 사용 및 신체 부위 분류 성능 향상 연구)

  • Seongwon Na;Yousun Ko;Kyung Won Kim
    • Journal of Broadcast Engineering
    • /
    • v.28 no.3
    • /
    • pp.293-301
    • /
    • 2023
  • Unstandardized medical data collection and management are still being conducted manually, and studies are being conducted to classify CT data using deep learning to solve this problem. However, most studies are developing models based only on the axial plane, which is a basic CT slice. Because CT images depict only human structures unlike general images, reconstructing CT scans alone can provide richer physical features. This study seeks to find ways to achieve higher performance through various methods of converting CT scan to 2D as well as axial planes. The training used 1042 CT scans from five body parts and collected 179 test sets and 448 with external datasets for model evaluation. To develop a deep learning model, we used InceptionResNetV2 pre-trained with ImageNet as a backbone and re-trained the entire layer of the model. As a result of the experiment, the reconstruction data model achieved 99.33% in body part classification, 1.12% higher than the axial model, and the axial model was higher only in brain and neck in contrast classification. In conclusion, it was possible to achieve more accurate performance when learning with data that shows better anatomical features than when trained with axial slice alone.

Spontaneous Intracranial Hypotension (자발성 두개강내압 저하증)

  • Kong, Doo Sik;Kim, Jong Soo;Park, Kwan;Nam, Do Hyun;Eoh, Whan;Shin, Hyung-Jin;Hong, Seung-Chyul;Kim, Jong Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.240-248
    • /
    • 2000
  • Objective : Spontaneous intracranial hypotension is a rarely reported syndrome of spontaneous postural headache associated with low CSF pressure and has rarely been demonstrated radiographically or surgically. But recently, it is being recognized with increasing frequency. The purpose of this study was to characterize clinical and imaging features, etiologic factors, and outcome in the spontaneous intracranial hypotension. Patients and Methods : We reviewed our experience with documented cases of spontaneous intracranial hypotension in 5 consecutive patients with orthostatic headaches from April 1998 to April 1999. Results : The mean age was 41 years(from 35 to 49 years). All patients had postural headaches, which were completely alleviated by recumbency position. Nausea, neck pain, horizontal diplopia, photophobia, and blurred vision were noted in some of the patients. Brain MRI showed diffuse pachymeningeal gadolinium enhancement, subdural collections of fluid, and descent of the brain. The opening pressure from lumbar puncture was $4cmH_2O$ or less in three of five patients whereas the opening pressure was within normal range in two patients. All patients underwent radioisotope cisternography and computerized tomographic myelography. On radioisotope cisternography, CSF leakage was suspected at the level of cervical area(1 patient), upper thoracic area(2 patients), mid-thoracic area(1 patient). Computed tomography myelography revealed extraarachnoid accumulation of contrast media(compatible finding with CSF leakage) at the level of cervical or thoracic area. In all patients, the symptoms resolved in response to supportive measures or epidural blood patch(1 patient). Conclusion : Spontaneous spinal CSF leakage is increasingly recognized as a cause of spinal postural headache. Most CSF leaks are located at the cervicothoracic junction or in the thoracic spine and can be demonstrated by variable diagnostic method. The condition is usually self-limiting and its prognosis is typically good.

  • PDF