• Title/Summary/Keyword: computed tomography angiography

Search Result 312, Processing Time 0.027 seconds

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Comparative Analysis of Image Quality and Adverse Events between Iopamidol 250 and Ioversol 320 in Hepatic Angiography for Transcatheter Arterial Chemoembolization (경동맥 화학색전술을 위한 간동맥 혈관조영술에서 Ioversol 320과 비교한 Iopamidol 250의 영상 화질 비교 분석과 조영제 유해반응 평가)

  • Min Jae Gu;Jae Hyuck Yi;Young Hwan Kim;Hee Jung Lee;Ung Rae Kang;Seung Woo Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.166-175
    • /
    • 2020
  • Purpose This study aimed to compare the image quality and adverse events between Iopamidol 250 and Ioversol 320 usage during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Materials and Methods Medical records and hepatic angiography from 113 patients who underwent TACE with Iopamidol 250 (44 patients) and Ioversol 320 (69 patients) were retrospectively reviewed. Vessel perception on hepatic angiography was graded into three categories by two radiologists for hepatic subsegmental arteries, the right gastroepiploic artery, right gastric artery, and pancreaticoduodenal artery. Imaging concordance was assessed by comparing the number of detected HCCs on hepatic angiography and CT. The adverse events before and after hepatic angiography were evaluated. Results The mean vessel perception scores were 2.92 and 2.94 for Iopamidol 250 and Ioversol 320, respectively. The imaging concordance was 31 (70.5%) and 46 (66.7%) patients for Iopamidol 250 and Ioversol 320, respectively. There were no statistical differences in vessel perception or imaging concordance (p > 0.05). One and six patients experienced nausea for Iopamidol 250 and Ioversol 320, respectively. There was no statistical difference in adverse events (p = 0.24). Conclusion Iopamidol 250 can be used in hepatic angiography for TACE without significant difference in image quality or occurrence of adverse events from Ioversol 320.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Clinical Analysis of C.N.S. Cysticercosis (뇌 낭미충증에 관한 임상적 연구)

  • Cho, Soo-Ho;Moon, Choong-Bae;Choi, Byung-Yearn
    • Journal of Yeungnam Medical Science
    • /
    • v.1 no.1
    • /
    • pp.25-34
    • /
    • 1984
  • During last 10 years we experienced 25 cases of C.N.S. cysticercosis. Now clinical analysis and evaluation of our cases were made and the results are followings: 1. Prevalence in man and women are nearly same and about 70% of cases are distributed between 20-50 years old. 2. According to Nieto's classification, mostly are ventricular (44%) and parenchymal type (36%). 3. Clinical manifestations were IICP (92%), focal neurological deficits (68%), seizure (48%), altered mental status (36%) and others listed on table 7. 4. In ventricular type, IICP and cerebellar dysfuction signs were predominated but seizure and focal neurological deficits were commonly seen in parenchymal type. 5. Subcutaneous cysticercus nodules were palpated in 32 % of cases. 6. Positive stool ova was observed in 29% of cases. 7. Radiologic studies revealed as followings: 16 % of cases showed abnormal findings on plain film, 84% on angiography, 94% on ventriculography and 100% on computed tomography and myelography. Computed tomography looks like most helpful diagnostic method for C.N.S. cysticercosis, they ususally revealed lucent cystic lesion, hydrocephalic findings and contrast enhancement. 8. Suboccipital craniectomy, craniotomy with removal of parenchymal cyst or laminectomy were done according to location and types of lesion. 72 % of operated cases revealed good results and motarlity was 4 % of cases.

  • PDF

Comparison of Intraperitoneal and Retroperitoneal/Pelvic Contrast Extravasation: The Characteristics and Prognosis of the Each Patient Group with Arterial Embolization according to the Abdominal Computed Tomography Scanning after Blunt Trauma (둔상 후 복부 전산화단층촬영에서 조영제 유출로 동맥색전술을 시행받은 환자의 복강내와 후복막강/골반강내 출혈 비교)

  • Yoon, Ji Young;Kim, Sun Hyu;Ahn, Ryeok;Hwang, Jae Cheol;Hong, Eun Seog
    • Journal of Trauma and Injury
    • /
    • v.22 no.2
    • /
    • pp.199-205
    • /
    • 2009
  • Purpose: This study compared the characteristics of and the prognosis for intraperitoneal and retroperitoneal/pelvic contrast extravasation, which had been confirmed by enhanced abdominal CT scan, after blunt trauma in patients who had undergone angiographic embolization. Methods: From January 2001 to March 2009, data were retrospectively collected regarding patients who had undergone contrast extravasation (CE) on CT scanning and arterial embolization after blunt trauma. The study patient group was divided into the intraperitoneal and the retroperitoneal/pelvic groups according to the area of contrast extravasation. We reviewed the initial demographic data, the location of injury, the solid organ injury, the embolized vessel, and the clinical outcome. Results: The mean age of the study subjects was $40.2{\pm}2.6$ years old, and there were 24 male patients. The intraperitoneal group included 10 patients, and retroperitoneal/pelvic group was comprised of 17 patients. The amount of transfusion from presentation to intervention and during the first 24 hours was greater in the retroperitoneal/pelvic group than in the intraperitoneal group. The intraperitoneal group showed a higher frequency and severity of liver injury than the retroperitoneal/pelvic group. Angiography revealed that the hepatic artery (n=4) was the most frequently embolized vessel in the intraperitoneal group, while the internal iliac artery (n=6), followed by the renal artery (n=4), internal pudendal artery (n=3), and the gluteal artery (n=2), were the most frequently injured vessels in the retroperitoneal/pelvic group. Conclusion: In patients with intra-abdominal contrast extravasation found on CT scanning and arterial embolization after blunt trauma, the need for transfusion was less in the intra-abdominal group than in the retroperitoneal/pelvic group. Liver injury was also more frequent and severe in the intraperitoneal group than in the retroperitoneal/pelvic group.

Comparison of Clinical Significance Between Chest CT Scan and Bronchoscopy Prior to Bronchial Artery and Outcome of Embolization in Patients with Hemoptysis (객혈환자의 기관지동맥 조영술 전 흉부 전산화 단층촬영과 기관지내시경 검사의 유용성 비교 및 색전술 성적)

  • Jang, Jung Hyun;Ryu, Kum-Hei;Kwon, Jung Mi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.551-559
    • /
    • 2003
  • Background : Emergency management in hemoptysis is bronchial artery angiography and embolization. This study was designed to investigate the accuracy of localization of bleeding site by simple roentgenogram, computed tomography(CT) and bronchoscopy prior to embolization and to evaluate the outcome of embolotherapy. Method : We retrospectively evaluated 50 patients performed bronchial artery embolization(BAE), admitted to tertiary university hospital due to hemoptysis. Results : The most common causes were pulmonary tuberculosis, old tuberculous related parenchymal damage, aspergilloma, and bronchiectasis. The success rate of BAE within one month was 90%; within 3 months was 88%; during follow up period of mean 11.6 months was 76%. The concordant rate of simple roentgenogram with angiographic outcome in terms of bleeding site is 70%; in chest CT 80%; in bronchoscopy 81%; in combined information of simple roentgenogram and CT 83%; in combined information of simple roentgenogram and bronchoscopy 78%. Conclusion : The diagnostic accuracy for the bleeding site was similar between chest CT and bronchoscopy, showing high diagnostic yield. The success rate of BAE was comparative to prior studies. Further study will be needed in a large scale in near future.

Evaluation of the Effect of the Arrhythmia Correction for the Image Quality in the Multidetector-Row Computed Tomography (MDCT) Coronary Angiography (Multidetector-Row Computed Tomography (MDCT) Coronary Agniography에서 Arrhythmia Correction이 영상의 질에 미치는 영향에 관한 연구)

  • Kim, Hyun-Soo;Kim, Keung-Sik;Kim, Tae-Hoon;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2004
  • MDCT is a useful, non-invasive, diagnostic tool in the evaluation of coronary artery disease. However, the image quality is affected by an irregular heart rhythm of the patients. Especially, premature ventricular contraction induced stair-step artifacts in the reconstruction of 2-D or 3-D images of the heart including coronary arteries. In recent, we experienced some improving of the image quality after correcting the PVC. Accordingly, the purpose of our study was to evaluate the effectiveness of the arrhythmia correction method, which was commercially available software, in improving the quality of the reconstruction images of the heart. Image analysis was performed, in consensus, by two radiologists. The scores for image quality were ranked as follows; excellent is 4 (image quality is markedly improved and is helpful in the image evaluation), good is 3 (image quality is mildly improved, but is somewhat helpful in the image evaluation), fair is 2 (image quality is improved and is not helpful in the image evaluation), and poor is 1 (image quality is not improved). We used ANOVA method to evaluate the statistical significant differences in the image qualities among the correction methods of the arrhythmia with below 0.05 of p-value. The method of moving the R-R interval showed statistically significant differences in improving of the image quality in patients with arrhythmia. We concluded that the regulation of R-R interval in patients with arrhythmia was an effective method to improve the image quality in the reconstructions of the MDCT coronary angiograms.

  • PDF

Evaluation of the Ostium in Anomalous Origin of the Right Coronary Artery with an Interarterial Course Using Dynamic Cardiac CT and Implications of Ostial Findings

  • Jin-Young Kim;Yoo Jin Hong;Kyunghwa Han;Suji Lee;Young Jin Kim;Byoung Wook Choi;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.172-179
    • /
    • 2022
  • Objective: We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. Materials and Methods: From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. Results: During a median follow-up period of 2071 days (interquartile range, 1180.5-2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. Conclusion: The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

Femoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass

  • Byun, Joung Hun;Kim, Tae Gyu;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.50 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • Background: Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods: Between April 2012 and October 2015, 16 patients (18 limbs) with lifestyle-limiting claudication (n=12) or chronic critical limb ischemia (n=6) underwent femoral-above-knee (AK) polytetrafluoroethylene (PTFE) bypass grafts with a bridging stent graft placement between the distal target popliteal artery and the PTFE graft. Ring-supported PTFE grafts were used in all patients with no available vein for graft material. Follow-up evaluations assessed clinical symptoms, the ankle-brachial index, ultrasonographic imaging and/or computed tomography angiography, the primary patency rate, and complications. Results: All procedures were successful. The mean follow-up was 12.6 months (range, 11 to 14 months), and there were no major complications. The median baseline ankle-brachial index of 0.4 (range, 0.2 to 0.55) significantly increased to 0.8 (range, 0.5 to 1.0) at 12 months (p<0.01). The primary patency rate at 12 months was 83.3%. The presenting symptoms resolved within 2 weeks. Conclusion: In AK bypasses with a diffusely diseased distal target popliteal artery or when below-knee (BK) bypass surgery is impossible, this procedure could be clinically effective and safe when used as an alternative to femoral-BK bypass surgery.