• 제목/요약/키워드: computed tomography angiography

검색결과 312건 처리시간 0.018초

Rupture of De Novo Anterior Communicating Artery Aneurysm 8 Days after the Clipping of Ruptured Middle Cerebral Artery Aneurysm

  • Ha, Sung-Kon;Lim, Dong-Jun;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권3호
    • /
    • pp.236-238
    • /
    • 2013
  • Rapidly developed de novo aneurysm is very rare. We present a rapidly developed and ruptured de novo anterior communicating aneurysm 8 days after the rupture of another aneurysm. This de novo aneurysm was not apparent in the initial 3-dimensional computed tomography and digital subtraction angiography. We reviewed the literature and discussed possible mechanisms for the development of this de novo aneurysm.

Persistent Hypoglossal Artery

  • Ahn, Jae-Heung;Choe, Woo-Jin;Park, Hyo-Il;Lee, Chae-Heuck
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권4호
    • /
    • pp.312-315
    • /
    • 2005
  • The persistent hypoglossal artery[PHA] is a rare anomaly that belongs to the group of embryonic carotid-basilar artery anastomoses that may occur in adults. The most commonly reported type of such an anastomosis is the primitive trigeminal artery, followed by the PHA. We report a 35-year old man, hospitalized because of an intraventricular hemorrhage, who was found to have a right persistent PHA. Three-dimensional computed tomography[CT] angiography provided excellent anatomical topology of the anomaly. To our knowledge, this patient is the first case of a PHA identified by this means in Korea.

관상동맥조영술과 MDCT를 이용한 관상동맥 이식편의 비교평가 (Comparison of Multidetector Computed Tomography with Coronary Angiography for Evaluation of Coronary Artery Bypass Grafts)

  • 유병수;신윤철;김건일;김응중;지현근
    • Journal of Chest Surgery
    • /
    • 제39권1호
    • /
    • pp.42-47
    • /
    • 2006
  • 배경: 새로 나온 다절편 전산화흥부단층촬영(Multidetector Computed Tomography: MDCT)은 관상동맥 영상화에 유용하다. 본 교실에서는 관상동맥우회로 술을 시행한 환자에서 술 후 관상동맥 이식편의 평가를 위하여 비침습적 MDCT와 기존의 침습적 관상동맥조영 술의 유용성을 비교하였다. 대상 및 방법: 2003년 11월부터 2004년 11월까지 관상동맥우회로 술을 시행한 후 16 Channel MDCT와 관상동맥조영 술 모두에 동의한 15명을 대상으로 52개의 이식편의 개존성을 분석하였다. MDCT를 이용하여 3차원으로 재조합된 영상과 관상동맥조영술을 통해 얻은 영상을 비교하여 민감도, 특이도, 양성 예측치, 음성 예측치 등을 계산하였다 결과: 환자당 평균 3.4$\pm$0.8개의 도관을 사용하였다. MDCT 도중 환자들의 평균 심박동수는 86회/분(범위, 60$\∼$110회/분)이어서 베타차단제는 사용하지 않았다. 모든 환자들이 필요한 시간만큼 호흡을 참을 수 있었다. 관상동맥조영 술을 통해 얻은 전체 이식편 개존율은 96.2$\%$였다. MDCT의 진단력은 민감도 100$\%$,특이도 98.0$\%$, 양성 예측치 100$\%$,음성 예측치 66$\%$였다. 결론: 관상동맥우회로 술 후 16 Channel MDCT는 기존의 관상동맥조영 술과 비교하여 이식편의 개존상태와 혈류 정도 파악에 신뢰할 수 있는 수준이며, 비침습적이며 저렴하므로 관상동맥조영 술을 대체할 수 있을 것이다.

Assessment of Cerebral Circulatory Arrest via CT Angiography and CT Perfusion in Brain Death Confirmation

  • Asli Irmak Akdogan;Yeliz Pekcevik;Hilal Sahin;Ridvan Pekcevik
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.395-404
    • /
    • 2021
  • Objective: To compare the utility of computed tomography perfusion (CTP) and three different 4-point scoring systems in computed tomography angiography (CTA) in confirming brain death (BD) in patients with and without skull defects. Materials and Methods: Ninety-two patients clinically diagnosed as BD using CTA and/or CTP for confirmation were retrospectively reviewed. For the final analysis, 86 patients were included in this study. Images were re-evaluated by three radiologists according to the 4-point scoring systems that consider the vessel opacification on 1) the venous phase for both M4 segments of the middle cerebral arteries (MCAs-M4) and internal cerebral veins (ICVs) (A60-V60), 2) the arterial phase for the MCA-M4 and venous phase for the ICVs (A20-V60), 3) the venous phase for the ICVs and superior petrosal veins (ICV-SPV). The CTP images were independently reviewed. The presence of an open skull defect and stasis filling was noted. Results: Sensitivities of the ICV-SPV, A20-V60, A60-V60 scoring systems, and CTP in the diagnosis of BD were 89.5%, 82.6%, 67.4%, and 93.3%, respectively. The sensitivity of A20-V60 scoring was higher than that of A60-V60 in BD patients (p < 0.001). CTP was found to be the most sensitive method (86.5%) in patients with open skull defect (p = 0.019). Interobserver agreement was excellent in the diagnosis of BD, in assessing A20-V60, A60-V60, ICV-SPV, CTP, and good in stasis filling (κ: 0.84, 0.83, 0.83, 0.83, and 0.67, respectively). Conclusion: The sensitivity of CTA confirming brain death differs between various proposed 4-point scoring systems. Although the ICV-SPV is the most sensitive, evaluation of the SPV is challenging. Adding CTP to the routine BD CTA protocol, especially in cases with open skull defect, could increase sensitivity as a useful adjunct.

Vascular anatomy and their variations in Situs inversus totalis using postmortem computed tomographic angiography

  • Dawa Zangpo;Hironobu Nakane;Morio Iino
    • Anatomy and Cell Biology
    • /
    • 제56권1호
    • /
    • pp.155-159
    • /
    • 2023
  • Studies describing the vascular systems and their variations in Situs inversus totalis (SIT) from a whole-body computed tomographic (CT) angiography perspective are lacking. We report a case of SIT in which postmortem CT angiography (PMCTA) was performed as a part of the forensic death investigation and incidentally detected several vascular variations in it. The PMCTA procedure was performed using the multiphase PMCTA protocol. Almost all major vessels were visualized, indeed in a completely reversed pattern. Contrast mixture flow interruptions were noted in the right coronary arterial branches suggesting possible blockage, upon which autopsy revealed >90% vessel occlusions at several locations. As such the cause of death was due to ischemic heart disease. Anomalous origins of the right internal mammary artery; abnormal left thyrocervical trunk and variations in the drainage of testicular veins were noted. Our findings might be helpful to clinicians and add to the body of literature on SIT.

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • 한국의학물리학회지:의학물리
    • /
    • 제32권1호
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Computed tomographic anatomy of hepatic artery in normal beagle dogs

  • Kim, Soochan;Jeong, Seongmok;Lee, Heechun;Lee, Youngwon;Choi, Hojung
    • 대한수의학회지
    • /
    • 제59권2호
    • /
    • pp.55-58
    • /
    • 2019
  • This study was performed to examine the visualization and anatomical variants of the hepatic artery with dual-phase computed tomography (CT) angiography and three-dimensional volume rendering imaging analysis in clinically normal dogs. Seven healthy beagle dogs were enrolled and underwent dual CT angiography. Arterial phase images could be obtained with multi-detector CT angiography using the fixed-scan method in these dogs. Contrast enhancement of the hepatic parenchyma was quite minimal because of the unique blood supply system of the liver. In most dogs, the main hepatic arterial branches were the right lateral branch, left branch, and right medial branch. Although hepatic arterial variation appears to be common in dogs, only one dog in this study had the caudate lobar branch as the first branch of the hepatic artery. Further study on a larger number of dogs with CT images will be needed to identify and classify the pattern of hepatic arterial variations.

Application of Quantitative Assessment of Coronary Atherosclerosis by Coronary Computed Tomographic Angiography

  • Su Nam Lee;Andrew Lin;Damini Dey;Daniel S. Berman;Donghee Han
    • Korean Journal of Radiology
    • /
    • 제25권6호
    • /
    • pp.518-539
    • /
    • 2024
  • Coronary computed tomography angiography (CCTA) has emerged as a pivotal tool for diagnosing and risk-stratifying patients with suspected coronary artery disease (CAD). Recent advancements in image analysis and artificial intelligence (AI) techniques have enabled the comprehensive quantitative analysis of coronary atherosclerosis. Fully quantitative assessments of coronary stenosis and lumen attenuation have improved the accuracy of assessing stenosis severity and predicting hemodynamically significant lesions. In addition to stenosis evaluation, quantitative plaque analysis plays a crucial role in predicting and monitoring CAD progression. Studies have demonstrated that the quantitative assessment of plaque subtypes based on CT attenuation provides a nuanced understanding of plaque characteristics and their association with cardiovascular events. Quantitative analysis of serial CCTA scans offers a unique perspective on the impact of medical therapies on plaque modification. However, challenges such as time-intensive analyses and variability in software platforms still need to be addressed for broader clinical implementation. The paradigm of CCTA has shifted towards comprehensive quantitative plaque analysis facilitated by technological advancements. As these methods continue to evolve, their integration into routine clinical practice has the potential to enhance risk assessment and guide individualized patient management. This article reviews the evolving landscape of quantitative plaque analysis in CCTA and explores its applications and limitations.

Preoperative Identification of a Perforator Using Computed Tomography Angiography and Metal Clip Marking in Perforator Flap Reconstruction

  • Lee, Jung Woo;Kim, Han Kyeol;Kim, Sin Rak;Han, Yea Sik;Park, Jin Hyung
    • Archives of Plastic Surgery
    • /
    • 제42권1호
    • /
    • pp.78-83
    • /
    • 2015
  • In perforator flap reconstruction, vascular mapping using preoperative computed tomography (CT) angiography is widely used to confirm the existence and location of an appropriate perforator. This study proposes a rapid, accurate, and convenient method for marking the perforator location on the skin surface. For 12 patients who underwent perforator flap reconstruction between November 2011 and November 2013, metal clips were fixed on the skin surface at the anticipated perforator locations, which were decided using a handheld Doppler. CT angiography was used to compare the location between the metal clip and the actual perforator. The metal clip was moved and repositioned, if needed, on the basis of the CT images. The locations of the appropriate perforator and the metal clip, which were observed during the surgery, were then compared. In CT angiography, the mean distance between the metal clip and the perforator was $3{\pm}3.9mm$, and the mean distance that was measured during surgery was $0.8{\pm}0.8mm$. In conclusion, we report a simple, rapid, and precise technique to indicate the accurate location of the appropriate perforator on the skin surface.