• Title/Summary/Keyword: compressive strength of standard

Search Result 552, Processing Time 0.028 seconds

Effect of Carbon Dioxide-reduced Cement on Properties of Lightweight-foamed Concrete (이산화탄소 저감형 시멘트 함량에 따른 경량기포 콘크리트의 물성평가)

  • Im, Donghyeok;Lee, Won-Ki
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.605-612
    • /
    • 2020
  • To improve the initial strength and stability of lightweight-foamed concrete, which shows suitable sound absorption and insulation characteristics, the effect of CO2-reduced cement on the properties of the concrete was investigated. Various mixing ratios were applied by substituting a certain amount of slag and Calcium Sulfo Aluminate (CSA) in CO2-reduced Ordinary Portland Cement (OPC) and the physical properties of the samples were examined using the Korean Standard. The kiln temperatures of the CSA were 100-200℃ ; these values are lower than those of OPC and can lead to energy saving. In addition, the low limestone content reduces greenhouse gas emissions by 20 %. Adding a small amount of CSA in OPC content activates Ca-Al-H2-based hydrates, and the initial compressive strength of the concrete is improved. As the CSA content increased, the thermal conductivity of the concrete decreased by up to 8% compared to plain concrete, thus indicating an improvement in its insulation. Therefore, the settlement stability was improved as the addition of CSA shortened the setting time.

Mechanical Properties of ODS Fe Alloys Produced by Mechano-Chemical Cryogenic Milling (극저온 기계화학적 밀링(Mechano-Chemical Milling)에 의해 제조된 ODS Fe 합금의 기계적 특성)

  • Hahn, Sung-In;Hong, Young-Hwan;Hwang, Seung-Joon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.3
    • /
    • pp.138-145
    • /
    • 2012
  • An ${\alpha}$-Ferrite (Fe) powder dispersed with 4 vol.% of $Al_2O_3$ was successfully produced by a simple miling at 210 K with a mixture of $Fe_2O_3$, Fe and Al ingredient powders, followed by 2 step high temperature consolidation: Hot Pressing (HP) at 1323 K and then Hot Isostatic Pressing at 1423 K. The microstructure of the consolidated material was characterized by standard metallographic techniques such as XRD (X-ray Diffraction), TEM and STEM-EDS. The results of STEM-EDS analysis showed that the HIPed materials comprised a mixture of pure Fe matrix with a grain size of ~20 nm and $Al_2O_3$ with a bimodal size distribution of extremely fine (~5 nm) and medium size dispersoids (~20 nm). The mechanical properties of the consolidated materials were characterized by compressive test and micro Vickers hardness test at room temperature. The results showed that the yield strength of the ODS (Oxide Dispersion Strengthened) Fe alloy are as much as $674{\pm}39$ MPa and the improvement of the yield strength is attributed to the presence of the fine $Al_2O_3$ dispersoid.

Fire Behavior of Reinforced Concrete Filled Square Steel Tube Columns Under Constant Axial Loads

  • Jeeyoung Lee;Seulgi Han;Jinwon Shin;Inrak Choi;Sungmo Choi
    • International Journal of High-Rise Buildings
    • /
    • v.13 no.1
    • /
    • pp.85-95
    • /
    • 2024
  • A composite member made of concrete-filled steel tubes (CFT columns) has been recognized for its fire resistance due to the thermal mass effect of concrete inside the steel tube, as shown in various studies. In this study, the fire resistance performance of reinforced CFT columns under constant axial load was evaluated using finite element analysis with ABAQUS. For this purpose, the variables including cross-section size, steel tube thickness, and concrete cover thickness were set, and the temperature distribution in the column cross-section exposed to a standard fire was investigated using heat transfer analysis. Ultimately, a P-M interaction curve was obtained by evaluating the overall residual strength of columns, and the fire resistance time was determined by evaluating axial displacement-time responses due to the reduction in load capacity during fire through stress analysis.

The Chloride Ion Diffusivity of Ready-Mixed Concrete Depending on Specified Compressive Strength (레디믹스트 콘크리트의 설계기준 압축강도별 염소이온 확산특성)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.6
    • /
    • pp.543-550
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforcing steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is higher than 35MPa in the concrete/building construction standard specification. Even though it has been proved that the concrete mixed with mineral admixture such as blast furnace slag and fly ash etc. have high strength and durability in previous researches, the beneficial informations are not applied to the codes. Ready-mixed concretes which usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC. For economical and reliable durability design, chloride ion diffusivity should be measured before applying to new building construction.

Manufacturing Zero-Cement Bricks by Replacing Cement with Recycled Aggregates and Blast Furnace Slag Powder

  • Park, Kyung-Taek;Han, Cheon-Goo;Kim, Dae-Gun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.29-37
    • /
    • 2013
  • In this study, a zero-cement brick is manufactured by replacing cement with recycled aggregates and blast furnace slag powder. Experimental tests were conducted with standard sized samples of $190{\times}57{\times}90mm$ (KS F 4004), and this manufacturing technique was simulated in practice. Results showed that the zero-cement brick with 0.35 W/B had the highest compressive strength, but the lowest absorption ratio. This absorption ratio of zero-cement brick with 0.35 W/B was lower than the required level determined by KS F 4004. Hence, to increase the absorption ratio, crushed fine aggregate (CA) and emulsified waste vegetable oil (EWO) were used in combination in the zero-cement brick. It was found that the zero-cement brick with CA of 20% and EWO of 1% had the optimum combination, in terms of having the optimum strength development (12 MPa) and the optimum absorption ratio (8.4%) that satisfies the level required by KS. In addition, it is demonstrated that for the manufacturing of zero-cement brick of 1000, this technique reduces the manufacturing cost by 5% compared with conventional cement brick.

Field Application of the Concrete with the Combination of Drying Shrinkage-Reducing Superplasticizer and Double Layer Bubble Sheet (건조수축 저감형 유동화제 및 2 중 버블시트를 사용한 콘크리트의 현장적용)

  • Han, Cheon-Goo;Oh, Chi-Hyun;Shin, Jae-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.1 s.23
    • /
    • pp.107-113
    • /
    • 2007
  • This study investigates the filed application in Daebul Free Trade Zone applying both a flowing method using drying shrinkage-reducing superplasticizer(SRS) and an insulating curing method using double layer bubble sheet. Test results showed that fresh concrete satisfied target slump and air content. A structure adding SRS significantly decreased the total bleeding capacity and accelerated the setting time. As for the crack occurrence, the structure applying the flowing method and double bubble sheets simultaneously exhibited the most favorable crack endurance, while conventional concrete showed more than 1mm size of crack in overall. In addition, a structure applying the flowing concrete method partially presented the micro crack. For the area proportion of crack occurrence, the structure using the double bubble sheets indicated 9.8%, while others applying flowing concrete method was 28%, compared with that of conventional one. For the compressive strength of specimens, standard curing specimens indicated $3{\sim}33%$ higher value than that of specimens cured besides the field construction. The specimens containing SRS improved the strength of $2{\sim}6MPa$, which is $10{\sim}22%$ higher than that of conventional concrete.

Mechanical Properties of Stabilizer Link Using Composite Material and Metal (금속과 복합재료를 이용한 스태빌라이저 링크의 기계적 특성 평가)

  • Woo, Young-Man;Nam, Ki-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.877-882
    • /
    • 2011
  • Stabilizers are balancing equipment that can reduce the severe rolling of ships, vehicles, and aircraft. We manufactured a stabilizer link using a metal and a composite material with 25% POM-GF. We evaluated the strength of the stabilizer link via tensile, compressive, and ball-stud separation. The standard criteria were satisfied. Of four types of rod, knurled rod has the greatest strength. We improved the shape of the stabilizer-link body by a reanalysis of the injection molding.

The Properties of Restorative Cement Mortar with Insulation Performance for Improvement of Durability (내구성 향상을 위하여 단열성능이 부여된 단면복구 MORTAR의 물성)

  • Kang, Hyun-Ju;Na, Seung-Hyun;Song, Myong-Shin;Jeong, Eui-Dam;Seo, Byung-Dol
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.5
    • /
    • pp.373-380
    • /
    • 2010
  • In this study, we studied on the durability of restorative cement mortar for deteriorated concrete at complex deteriorated conditions as variation of temperature and of humidities. We made a comparison between restorative materials with insulation function and restorative materials without insulation function in items of compressive and bending strength and permeability of water, durability for carbonation, salt damage, diffusion coefficient of salt at complex deterioration conditions like change of temperature, change of humidity, For insulation, we used close-pore type Alumino-Silicate lightweight aggregate and substituted 12 wt% and 15 wt% out of original restorative cement mortar without insulation function. As a result, it was found that original restorative cement mortar without insulation function fail to meet Korean Standard on polymer modified cement mortar for maintenance in concrete structure, but restorative cement mortar with insulation function is in contentment Korean Standard to meet excellent than restorative materials without insulation function for durability at complex deteriorated conditions.

Analysis of Inner Temperature in High Strength Concrete under Standard Temperature-time Curve (표준화재곡선에 의한 고강도 콘크리트 부재의 내부온도 예측)

  • Song, Hun;Lee, Sea-Hyun;Mun, Kyung-Ju;Do, Jeong-Yun;Soh, Yang-Seob
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.469-472
    • /
    • 2005
  • With all ensuring the fire resistance structure as a method of setting the required cover thickness to fire, the RC is significantly affected from the standpoint of its structural stability that the compressive strength and elastic modulus is reduced by fire. Normally, the degradation of concrete member exposed to fire is largely dependent on the fire scale and fire condition. There is therefore a need to precisely predict the deterioration and fire damage of the exposed member. Thus, this work estimated the temperature distribution inside a member taking into consideration of the thermal properties by means of finite element method(FEM). The estimation results in a little higher prediction value than the experimental value in surface layer and is almost coincident with the experiment as the heating depth increase. From this work it can be known that the simulation application of FEM using the thermal properties of concrete member in high temperature gives rise to the confident prediction in the prediction of temperature distribution.

  • PDF

Making the Insulation Mortar Mixed with Waste Paper and Sawdust (종이와 톱밥을 혼입한 단열 모르타르 재료 개발에 관한 연구)

  • Lee, Seung-Young;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.78-82
    • /
    • 2010
  • This study is to test insulation mortar mixed with wastepaper and sawdust to find out its insulation performance. Therefore, wastepaper and sawdust have been added to normal mortar. They are analyzed for the above purpose using compressive strength and insulation performance. It is found that the more wastepaper and sawdust will be mixed, the lower heat conductivity will be taken. Wastepaper and sawdust mixture will be more 2.0% then the insulation mortar quality can be compatible with the 3rd kind of the standard. Optimal mixture for insulation will be wast paper:sawdust=4:6. Cohesive test of materials showed that test material has stronger than stand are $0.10N/mm^2$. It is satisfactory the test result showed a range of $0.12{\sim}0.15N/mm^2$ from the test result. Optimal mixture of wastepaper and sawdust have been found out from the study comprehensively, exclusive of the proportion of wastepaper:sawdust = 8:2. It is thought that standard of length deformation; 0.5% is reasonable. This means that deformation of mortar itself can be considered. But it is also Shown that water mixture has also been sharply changed at first flow test. Therefore, it is thought that absorbed water content in the material gave considerable effect to variation rate.