• Title/Summary/Keyword: compressive strength equation

Search Result 359, Processing Time 0.024 seconds

Feasibility Analysis of Rapid Quality Evaluation Method for Blast Furnace Slag Using Hydrometer (Hydrometer를 이용한 고로슬래그 미분말의 분말도 품질 신속평가 가능성 분석)

  • Han, Cheon-Goo;Joo, Eun-Hui
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2018
  • The aim of the research is to analyze the feasibility of rapid quality evaluation method for blast furnace slag using hydrometer based on the former research of the prediction method for concrete compressive strength using hydrometer. Using this method, it is expected to provide a new application for blast furnace slag quality evaluation easily and rapidly during the receiving inspection. According to the experimental results, the settling time period of hydrometer was delayed with increased fineness of blast furnace slag. By using the regression equation of y = 198 120 x - 193 936(R=0.9398) obtained from the correlation between density of suspension at three minutes and fineness, it was possible to evaluate the quality of blast furnace slag fineness rapidly. Therefore, for ready-mixed concrete receiving inspection, the suggested method can be used as a cheap, a simple, and a rapid inspection method.

Development of the Hybrid CFFT Pile (FRP-콘크리트 합성말뚝의 개발)

  • Choi, Jin-Woo;Joo, Hyung-Joong;Nam, Jeong-Hun;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.20-28
    • /
    • 2010
  • In this paper, new type CFFT (Concrete Filled FRP Tube) was suggested in order to improve the flexural stiffness. Since the existing CFFT was produced by filament winding process, re-bar for concrete may be necessary in order to ensure structural safety under flexure re-bar. In comparison with existing type CFFT, new type CFFT was reinforced by circular shaped pultrusion FRP without re-bar. Filament winding FRP was attached to the outer layer of pultrusion FRP. Structural behavior of new type CFFT filled with concrete (HCFFT) was investigated by the mechanical property test for the component element and the FE analysis. Furthermore, compressive strength of the HCFFT member based on the equation suggested in previous studies.

  • PDF

Structural Behavior of the Reinforced Concrete Filled GFRP Tube (GFRP 보강 철근콘크리트 합성부재의 구조적 거동)

  • Lee, Seung-Sik;Joo, Hyung-Joong;Kang, In-Kyu;Yoon, Soon-Jong
    • Composites Research
    • /
    • v.23 no.4
    • /
    • pp.44-51
    • /
    • 2010
  • Recently, to solve the problems associated with the neutralization and corrosion of reinforced concrete compression members, the structural configurations such as CFFT (Concrete Filled GFRP Tube) and RCFFT (Reinforced Concrete Filled GFRR Tube) have been developed and applied to main members of civil engineering structure. These members can increase structural performance in terms of structural stability, ductility as well as chemical resistance compared with conventional concrete structural members. Many researches in numerous institutions to predict the load carrying capacity of the concrete compression member strengthened with FRP materials have been conducted and they have been suggested an equation for the prediction of the load carrying capacity of the members. Through the review of the research results, it was found that their results are similar each other. Moreover, it was also found that the results are not directly applicable to our specimens since the results are largely depended upon the member configurations. Also, since the accurate design criteria for the RC members strengthened with FRP such as RCFFT have not been established properly, relevant theoretical and experimental investigations must be conducted for the application to the practical structures. In this study, structural behavior of RCFFT was evaluated through compressive and quasi-static flexural tests in order to formulate design criteria for the structural design. In addition, the RCFFT members were also investigated to examine their confinement effect and the equations capable of estimating the compressive ultimate strength and flexural stiffness of the RCFFT members were proposed.

Design Factor Analysis of End-Effector for Oriental Melon Harvesting Robot in Greenhouse Cultivation (시설재배 참외 수확 로봇용 엔드이펙터의 설계 요인 분석)

  • Ha, Yu Shin;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.284-290
    • /
    • 2013
  • This study analyzed the geometric, compressive, cutting and friction properties of oriental melons in order to design a gripper capable of soft handling and a cutter for cutting oriental melon vine among the end effector of oriental melon as a preliminary step for developing the end effector of the robot capable of harvesting oriental melons in protected cultivation. As a result, the average length, diameter at the midpoint, weight, volume and roundness of the oriental melons were 108 mm, 70 mm, 188 g, 333 mL and 3.8 mm. Nonlinear regression analysis was performed on the equation $W=L^a{\times}D_2^b$ with variation of the length (L) and diameter (D2) of the weight (W) of the oriental melons. As a result, it was shown that there was a correlation between a of 2.0279 and b of -0.9998 as a constant value. The average diameter of the oriental melon vine was 3.8 mm, and most vines were distributed within a radius of 5 mm from the center. The average yield value, compressive strength and hardness of the oriental melons were $36.5N/cm^2$, $185.7N/cm^2$ and $636.7N/cm^2$, respectively. The average cutting force and shear strength of the oriental melon vines were $2.87{\times}10^{-2}\;N$ and $5.60N/cm^2$, respectively. The maximum friction coefficient of the oriental melons was rubber of 0.609, followed by aluminium of 0.393, stainless steel of 0.177 and teflon of 0.079. It was considered possible to apply it to the size of the gripper and cutter, turning radius, dynamics of drive motor and selection of materials and their quality in light of the position error and safety factor according to the movement when designing end effector based on the analyzed data.

The Influence Factors on the Compensation of Column Shortening in Tall Buildings (초고층 건물의 Column Shortening보정에 미치는 영향요소)

  • Mun, Il-Won;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.208-215
    • /
    • 2018
  • The causes of column shrinkage and the codes that have been studied up to now are discussed. The documents mentioned in the code deal with the drying shrinkage, creep, compressive strength and elastic modulus of the specimen, and the elastic deformation calculated from the structural analysis. However, the deformation due to the temperature caused by the long term monitoring is less than that caused by the factors generated by the previous studies. In the previous studies, it was found that dehydration shrinkage, creep, and elastic deformation were not considered for temperature-induced deformation, while for the specimen experiments, the temperature-related items were replaced with the humidity-related terms The compensation value by the proposed equation showed error of 4.9 mm in the upper direction and 1.0mm in the lower direction when calculating column shortening, and it was found that its value by the proposed equation almost coincided with the measurement value in Site. Therefore, it is necessary to further study the temperature that can be omitted in calculating the existing column shortening, to consider the influence factors, and to supplement the criteria for the temperature measurement of the structure as well as the specimen tests.

A Study on Carbonation Velocity for Concrete Structures (콘크리트 구조물의 탄산화속도에 관한 연구)

  • Kim, Jong Ho;Oh, Kwang Chin;Park, Seung Bum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2008
  • The carbonation velocity is produced an effect on carbon dioxide($CO_2$) density of surrounding near structures, the concrete quality and types of structures and this study was accomplished to draw a conclusion for estimated formula of carbonation velocity coefficient with various factors by the concrete quality on the base of the data of the durability surveyed in Korea. From the results of analysis of carbonation velocity, the followings were appeared. It is analyzed that carbonation velocity of the structures under urban area is 1.5 times faster than the rural area in the bridges case and it is 2.5 times faster than the rural area in the tunnels case. And the order of carbonation velocity of the structures under urban area is the buildings, the tunnels, the bridges and they are evaluated to progress about 2.7 times and 1.3 times faster than the bridges. In the rural area, the bridges are evaluated to progress about 1.3 times faster than the tunnels and it is analyzed that the carbonation velocity of the upper structures of the bridges under urban area is about 1.3 times faster than lower structures. The results which is compared to estimated formula of carbonation velocity coefficient of Kishitani equation which is generally applied for convert compressive strength into W/C ratios, most of those velocity of structures is faster than the results of Kishitani equation.

Performance evaluation of SFRC for tunnel segments based on large beam test (대형보 실험을 통한 TBM 터널 세그먼트용 강섬유보강콘크리트 성능평가)

  • Moon, Do-Young;Roh, Hwasung;Chang, Soo-Ho;Lee, Gyu-Phil;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.3
    • /
    • pp.287-298
    • /
    • 2014
  • In order to develop SFRC TBM tunnel segment, evaluating the SFRC mixture was conducted through flexural tests of SFRC beams without ordinary steel reinforcement in this study. Considered variables were compressive strengths of SFRC, aspect and mix ratio of steel fibers and total 16 specimens were fabricated and tested until failure. The load-vertical displacement results demonstrates that the effect of aspect ratio is minor when compared to results form small beam test(Moon et al, 2013). A SFRC beam resists the vertical load until the width of crack reaches to 7 mm due to steel fibers across cracked surfaces. Moreover, it is found that flexural moment estimated by equation of TR No. 63(Concrete Society, 2011) is useful for prediction of nominal strength for SFRC structure. From the investigation of fiber distribution in cracked section, it is found that dispersion improved in actual size beam compared to in standard small beam for evaluation of flexural strength.

Effect of the Inner Pressure on a Hybrid Composite Flywheel Retor (하이브리드 복합재 플라이휠 로터에 작용하는 내압의 효과)

  • Oh Je-Hoon;Han Sang-Chul;Kim Myung-Hoon;Ha Sung Kyu
    • Composites Research
    • /
    • v.18 no.1
    • /
    • pp.45-54
    • /
    • 2005
  • The delamination in the filament-wound composite flywheel rotor often lowers the performance of the flywheel energy storage system. A conventional ring type hub usually causes tensile stresses on the inner surface of the composite rotor, resulting in lowering the maximum rotational speed of the rotor. In this work, the stress and strain distributions within a hybrid composite rotor were derived from the two-dimensional governing equation with the specified boundary conditions, and an optimum pressure at the inner surface of the rotor was proposed to minimize the strength ratio and maximize the storage energy. A split type hub was introduced to apply the calculated optimum pressure at the inner surface, and a spin test was performed up to 40,000 rpm to demonstrate the performance of the split type hub with radial and circumferential strains measured using a wireless telemetry system. From the analysis and the test, it was found that the split type hub successfully generates a compressive pressure on the inner surface of the rotor, which can enhance the performance of the composite rotor by lowering the strength ratio within the rotor.

Ergonomic Assessment for Manual Materials Handling of Livestock Feed by Elderly Farmers in Korea

  • Kim, Insoo;Lee, Kyung-Suk;Kim, Kyung-Ran;Chae, Hye-Seon;Kim, Sungwoo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.279-291
    • /
    • 2015
  • Objective: The purpose of the study is to evaluate appropriate weight for aged farmers in manually handling livestock feed in bags using ergonomic methods. Background: In the livestock industry in South Korea, despite the trend of aging of labor manpower, heavy items are still manually handled in many farms. In particular, among stockbreeding works, the handling of feed in bags weighing 25~30kg is reported as a cause of frequent injuries and musculoskeletal system diseases. However, studies on the standard for recommended weight allowed considering the physical characteristics of aged farmers older than 60 years with greatly decreased physical strength and muscle strength are insufficient. Method: To evaluate appropriate weight for handling of heavy livestock feed in bags, physical techniques for measuring recognized levels of physical work loads, the NLE (NIOSH lifting equation) a method that is an observation type technique, and an ergonomic modeling technique to predict compressive force imposed on L5/S1 were used. Subjects who participated in the experiment were organized into two groups of males/females with mean age exceeding 60 years, and lifting tasks were evaluated for nine weight levels. Results: Based on the results of psychophysical measurement, females showed a tendency of more drastic increases compared to males when weight was over 19kg. The results of estimation of regression models for the weight, 18.0 kg ($r^2=0.97$) and 15.3kg ($r^2=0.97$) were evaluated as stable load for males and females, respectively. In addition, both the observation type evaluation and ergonomic model evaluation showed stable loads in a range of 15~18kg. Conclusion: Given the results of the study, the weight of the feed in bags currently distributed to farms can become a cause of not only overexertion but also farm work related disasters such as musculoskeletal disorders and safety accidents. Providing livestock feed in bags weighing not more than 19kg for aged farmers is judged desirable, and managerial improvement for this matter is considered necessary. Application: The results of the present study can be utilized as useful data for institutional improvement of the weight of livestock feed in bags.

Seismic Behaviour of Exterior Joints in Post-Tensioned Flat Plate Systems (포스트 텐션 플랫 플레이트 외부 접합부의 내진 거동)

  • Han, Sang-Whan;Kee, Seong-Hoon;Kang, Tomas H.K.;Cho, Jong;Lee, Li-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.5 s.95
    • /
    • pp.595-602
    • /
    • 2006
  • An experimental study was conducted to investigate seismic behaviour of post-tensioned(PT) exterior slab-column connections used for the purpose to resist gravity loads only. For these, 2/3-scale, two PT post-tensioned exterior connections with two different tendon arrangement patterns and one conventional reinforced concrete(RC) exterior connection was tested under quasi-static, uni-directional reversed cyclic loading. During the lateral testing, gravity forces transferred to the column were kept constant to closely simulate a moment to shear ratio of a real building. One of the objectives of this study was to assess the necessity and/or the quantity of bottom bonded reinforcement needed to resist moment reversal which would occur under significant inelastic deformations of the adjacent lateral force resisting systems. The ACI 318 and 352 provisions for structural integrity were applied to provide the bottom reinforcement passing through the column for the specimens. Prior test results were also collected to conduct comparative studies for some design parameters such as the tendon arrangement pattern, the effect of post-tensioning forces and the use of bottom bonded reinforcement. Consequently, the impact of tendon arrangement on the seismic performance of the PT connection, that is lateral drift capacity and ductility, dissipated energy and failure mechanism, was considerable. Moreover, test results showed that the amount of bottom reinforcement specified by ACI 352. 1R-89 was sufficient for resisting positive moments arising from moment reversal under reversed cyclic loads. Shear strength of the tested specimens was more accurately predicted by the shear strength equation(ACI 318) considering the average compressive stress over the concrete($f_{pc}$) due to post-tensioning forces than that without considering $f_{pc}$.