• 제목/요약/키워드: composite wall

검색결과 557건 처리시간 0.023초

철골-콘크리트 합성 연결보의 거동과 설계 (Behavior and Design of Steel-Concrete Composite Coupling Beams)

  • 홍성걸;양지연
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.433-438
    • /
    • 2003
  • Structural steel/composite beams provide a viable alternative for coupling individual reinforced concrete wall piers. Well-established guidelines for shear links in eccentrically braced steel frames form the basis of current design guidelines. However, these provisions ignore the effects of nominally reinforced concrete encasement which typically surrounds the coupling beam, and are based on overly conservative assumed deformation demand. A coordinated analytical research program at here has focused on response of steel/composite coupling beams, their connections to reinforced concrete walls, and overall behavior of composite coupled wall systems. Using the results from this study, guidelines for proper design and detailing of steel/composite coupling beams and beam-wall connections have been developed. This paper summarizes the research program, and highlights the basic concepts, important findings, and recommendations.

  • PDF

합성 지하벽의 전단성능 (Shear Capacity of Composite Basement Walls)

  • 김성만;이성호;서수연;이리형
    • 콘크리트학회논문집
    • /
    • 제14권3호
    • /
    • pp.321-330
    • /
    • 2002
  • 본 연구는 H-pile과 철근콘크리트 벽체를 전단연결재인 스터드 볼트를 사용하여 합성시킨 합성지하벽의 전단성능에 대한 실험연구 결과와 전단내력 산정시 적용시킬 수 있는 방안을 제시하고 있다. 합성지하벽의 전단성능에 영향을 미칠 합성율, 스터드볼트의 배치방법, 콘크리트벽체의 두께, 전단스팬비 및 전단보강근량을 주요변수로 선정하여 12개의 실험체를 제작하였다. 합성율을 제외한 주요 변수들은 합성지하벽의 전단내력에 영향을 미치는 것으로 나타났다. 아울러 합성지하벽의 전단내력 산정시 V=(Vc+Vre)+Vs라는 전단내력식을 기본식으로 하여 기존의 철근 콘크리트 전단내력식으로 제안된 ACI 318-99와 Zsutty식, Bazant식 그리고 철골의 전단내력식으로 제안된 강구조 한계상태 설계법에서 제시하고 있는 식으로 계산한 결과가 실험결과와 유사하게 나타남을 볼 수 있었다. 또한 소정의 합성율이 확보될 경우, 철골부재와 콘크리트벽체가 최대내력시까지 일체로 거동하며, 이를 고려하여 전단내력 산정시 합성부재의 전체깊이를 적용한 경우, 기존의 내력식을 이용하여 합성지하벽의 전단내력 예측이 가능할 것으로 판단된다.

Compressive behavior of profiled double skin composite wall

  • Qin, Ying;Li, Yong-Wei;Su, Yu-Sen;Lan, Xu-Zhao;Wu, Yuan-De;Wang, Xiang-Yu
    • Steel and Composite Structures
    • /
    • 제30권5호
    • /
    • pp.405-416
    • /
    • 2019
  • Profiled composite slab has been widely used in civil engineering due to its structural merits. The extension of this concept to the bearing wall forms the profiled composite wall, which consists of two external profiled steel plates and infill concrete. This paper investigates the structural behavior of this type of wall under axial compression. A series of compression tests on profiled composite walls consisting of varied types of profiled steel plate and edge confinement have been carried out. The test results are evaluated in terms of failure modes, load-axial displacement curves, strength index, ductility ratio, and load-strain response. It is found that the type of profiled steel plate has influence on the axial capacity and strength index, while edge confinement affects the failure mode and ductility. The test data are compared with the predictions by modern codes such as AISC 360, BS EN 1994-1-1, and CECS 159. It shows that BS EN 1994-1-1 and CECS 159 significantly overestimate the actual compressive capacity of profiled composite walls, while AISC 360 offers reasonable predictions. A method is then proposed, which takes into account the local buckling of profiled steel plates and the reduction in the concrete resistance due to profiling. The predictions show good correlation with the test results.

Improved analytical formulation for Steel-Concrete (SC) composite walls under out-of-plane loads

  • Sabouri-Ghomi, Saeid;Nasri, Arman;Jahani, Younes;Bhowmick, Anjan K.
    • Steel and Composite Structures
    • /
    • 제38권4호
    • /
    • pp.463-476
    • /
    • 2021
  • The concept of using Steel-concrete (SC) composite walls as retaining walls has recently been introduced by the authors and their effectiveness of resisting out-of-plane loads has also been demonstrated. In this paper, an improved analytical formulation based on partial interaction theory, which has previously been developed by the authors, is presented. The improved formulation considers a new loading condition and also accounts for cracking in concrete to simulate the real conditions. Due to a limited number of test specimens, further finite element (FE)simulations are performed in order to verify the analytical procedure in more detail. It is observed that the results from the improved analytical procedure are in excellent agreement with both experimental and numerical results. Moreover, a detailed parametric study is conducted using the developed FE model to investigate effects of different parameters, such as distance between shear connectors, shear connector length, concrete strength, steel plate thickness, concrete cover thickness, wall's width to thickness ratio, and wall's height to thickness ratio, on the behavior of SC composite walls subjected to out-of-plane loads.

Vibration and damping characteristics of the masonry wall strengthened with bonded fibre composite patch with viscoelastic adhesive layer

  • Laib, Salaheddine;Meftah, Sid Ahmed;Youzera, Hadj;Ziane, Noureddine;Tounsi, Abdelouahed
    • Computers and Concrete
    • /
    • 제27권3호
    • /
    • pp.253-268
    • /
    • 2021
  • The present paper treats the free vibration problem of the masonry wall strengthened with thin composite plate by viscoelastic adhesive layer. For this goal two steps are considered in the analytical solution. In the first one, an efficient homogenisation procedure is given to provide the anisotropic properties of the masonry wall. The second one is dedicated to purpose simplified mathematical models related to both in-plane and out-of-plane vibration problems. In these models, the higher order shear theories (HSDT's) are employed for a more rigours description of the shear deformation trough the masonry wall and the composite sheet. Ritz's method is deployed as solution strategy in order to get the natural frequencies and their corresponding loss factors. The obtained results are validated with the finite element method (FEM) and then, a parametric study is undertaken for different kinds of masonry walls strengthened with composite sheets.

Corner Steel plate-Reinforced Core Wall System

  • Park, Hong-Gun;Kim, Hyeon-Jin;Park, Jin-Young
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.193-199
    • /
    • 2019
  • For better structural performance and constructability, a new composite core wall system using steel plate columns at the corners of the core section was developed. Using the proposed core wall, nonlinear section analysis and 3-dimensional structural analysis were performed for the prototype core wall section and super high-rise building, respectively. The analysis results showed that, when compared to traditional RC core wall case, the use of the corner steel plate columns provided better structural capacity, which allows less wall thickness and re-bars. Further, due to such effects, the construction cost and time can be reduced despite the use of steel plate columns.

Seismic performance of CFS shear wall systems filled with polystyrene lightweight concrete: Experimental investigation and design methodology

  • Mohammad Rezaeian Pakizeh;Hossein Parastesh;Iman Hajirasouliha;Farhang Farahbod
    • Steel and Composite Structures
    • /
    • 제46권4호
    • /
    • pp.497-512
    • /
    • 2023
  • Using light weight concrete as infill material in conventional cold-formed steel (CFS) shear wall systems can considerably increase their load bearing capacity, ductility, integrity and fire resistance. The compressive strength of the filler concrete is a key factor affecting the structural behaviour of the composite wall systems, and therefore, achieving maximum compressive strength in lightweight concrete while maintaining its lightweight properties is of significant importance. In this study a new type of optimum polystyrene lightweight concrete (OPLC) with high compressive strength is developed for infill material in composite CFS shear wall systems. To study the seismic behaviour of the OPLC-filled CFS shear wall systems, two full scale wall specimens are tested under cyclic loading condition. The effects of OPLC on load-bearing capacity, failure mode, ductility, energy dissipation capacity, and stiffness degradation of the walls are investigated. It is shown that the use of OPLC as infill in CFS shear walls can considerably improve their seismic performance by: (i) preventing the premature buckling of the stud members, and (ii) changing the dominant failure mode from brittle to ductile thanks to the bond-slip behaviour between OPLC and CFS studs. It is also shown that the design equations proposed by EC8 and ACI 318-14 standards overestimate the shear force capacity of OPLC-filled CFS shear wall systems by up to 80%. This shows it is necessary to propose methods with higher efficiency to predict the capacity of these systems for practical applications.

접촉면 요소를 사용한 합성 지하벽의 비선형 해석 (Nonlinear Analysis of Composite Basement Wall Using Contact Element)

  • 서수연;이성호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권3호
    • /
    • pp.176-184
    • /
    • 2007
  • 본 연구의 목적은 H-Pile과 벽체가 합성하여 거동하는 합성 지하벽의 내력 및 구조적 거동을 해석적으로 파악하고 구조성능을 평가하여 다양한 형태의 응력조건에 대한 거동예측 방법을 제시하는 것이다. 이를 위하여 유한요소 범용 프로그램인 ATENA를 이용하여 H-Pile, 콘크리트 벽체, 스터드볼트 연결부 등에 대한 모델링방법을 설정하고 기 실험된 합성지하벽 실험체들에 대한 비선형 해석을 실시하였다. H-Pile과 콘크리트 벽체를 연결하는 스터드볼트에 의해 전달되는 전단 및 축응력을 접촉면 요소로 모델링하여 비선형 해석을 실시한 결과, 비록 초기강성은 해석결과가 다소 높게 나타났지만, 실험결과와 해석결과가 좋은 대응을 보이는 것으로 나타났다.

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.

친환경 점토질 다공블럭 벽체의 열성능 분석 연구 (A Study on Thermal Performance Analysis of the Sustainable Clayed Hollow Block Wall)

  • 장용성;박효순
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.65-70
    • /
    • 2004
  • The purpose of this study is to analysis the thermal performance of the clayed hollow block wall. Its thermal performance was evaluated comparison with the cement block wall, it was generally used in building envelope. To that end, we conducted a insulation performance experiment and heating and cooling load simulation for a respective wall. In addition, we calculated a construction cost for each other's wall. The results of this study can be summarized as follows. (1) According to experiment of a insulation performance, coefficient of overall heat transmission of the cement block wall and clayed hollow block wall was calculated respectively $2.72W/^2K$ and $1.42W/^2K$. (2) The annular load saving of the clayed hollow block wall was evaluated 1.5% larger than its of the cement block wall. (3) The construction cost of the clayed hollow block wall was calculated 73% more expensive than its of the cement block wall. (4) The construction cost of the clayed hollow block composite wall was calculated 13.7% more expensive than its of the cement block composite wall.