• Title/Summary/Keyword: composite panels

Search Result 394, Processing Time 0.032 seconds

Seismic Performance Assessment of a Modular System with Composite Section (합성단면을 적용한 모듈러 시스템의 내진 성능평가)

  • Choi, Young-Hoo;Lee, Ho-Chan;Kim, Jin-Koo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.69-77
    • /
    • 2017
  • By producing pre-engineered modular system in the factory, It is enable to expedite construction and can be distinguished from two types by the method resisting load. One is the open-sided modular system composed of beams and columns. The other is enclosed modular system composed of panels and studs. Of the modular systems, the open-sided modular system buildings the connection between modules are difficult due to closed member sections, and the overall strength is reduced as a result of local buckling. In this study, in order to solve these problems, a modular system with folded steel members filled with concrete are proposed. The capacity spectrum method presented in ATC 40 is used for seismic performance assessment of the proposed model structure and the structure with conventional steel members. The analysis results show that at the performance point of each model the number and rotation of plastic hinge formed in the proposed modular system are smaller than those in the conventional system. Based on this observation it is concluded that the proposed system with composite sections has superior seismic capacity compared with conventional system.

Enhancement of Ultrasonic C-scan Images for Inspection of Multi-layered Composite Panels (다층 후판 복합재 패널의 결함 검출을 위한 C-Scan 이미지 보정기법)

  • Cho Hyun;Song Sung-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.264-267
    • /
    • 2006
  • One of the serious problems that make the flaw identification in a multi-layered thick composite panel more difficult is the interferenceeffect of the upper layer. To take care of such a problem, here we propose an image enhancement approach that can get rid of such an interference effect to ultrasonic C-scan images by a normalization of the acquired signals by a reference signals, and demonstrate its performance in the experiments. Specifically, three specimens with artificial flaws are prepared and ultrasonic C-scan images are acquired experimentally to eliminate the undesired interference effect. Cleat successes are observed in the present study demonstrating the high potential of the proposed algorithm as a practical image enhancement tool in many practical situations.

  • PDF

Analysis of Sound Insulation Performance of Honeycomb Composite Panels for Cruise Ships (크루즈선박용 허니컴 패널의 차음 성능 해석)

  • Kwon, Hyun-Wung;Hong, Suk-Yoon;Roh, Jae-Ouk;Song, Jee-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.2
    • /
    • pp.234-240
    • /
    • 2014
  • In this paper, the interface matrix of honeycomb composite panel has been derived by the governing equation of a honeycomb sandwich panel. The interface matrix of honeycomb panel is added to the previously developed transfer matrix method, thus analysis of the multi-layered insulation composite panel with honeycomb is accomplished. Furthermore, predictions of sound transmission loss(STL) for the ship's insulation panel with honeycomb and mineral wool are presented. The insulation performance of the honeycomb used for skin of the ship's insulation panel is better than that of 0.35 mm steel panel by 2dB, approximately. Although honeycomb panel has inefficient insulation performance beside steel panel, honeycomb panel achieve improvements in the performance of weight reduction. The surface density of the panel with honeycomb is rather than with steel by $5.2kg/m^2$. It is decrease in weight by 31.7 %.

Geometric Modeling of the Skin-Stringer Integrated Panel with Three-Dimensional Woven Composite (3차원 직조 복합재료 스킨-스트링거 일체형 패널의 기하학적 모델링)

  • Yeonhi, Kim;Hiyeop, Kim;Jungsun, Park;Joonhyung, Byun
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.8-17
    • /
    • 2022
  • This paper presents a novel geometric modeling technique to predict the mechanical properties of an aircraft wing's skin-stringer integrated panel. Due to mechanical and adhesive fastening, this panel is vulnerable to stress concentration and debonding, so we designed it to integrate the skin and stringer using three-dimensional woven composites. Geometric modeling was conducted by measuring the geometric parameters of the specimen and defining the pattern of the yarns as functions. We used a weighted average model with iso-strain and iso-stress assumptions to predict the mechanical properties of the panel parts. We then compared the results of a finite element analysis with a compression test to verify the accuracy of our model. Our proposed technique proved to be more efficient than the traditional experimental method for predicting the mechanical properties of skin-stringer integrated panels.

Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 발코니 천정 내부결로 예측)

  • Choi Yoon-Ki;Ahn Jae-Bong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.155-163
    • /
    • 2003
  • There are a growing number of cases to expand balconies of apartments faced with open air in order to enhance functional satisfaction and efficiency of dwelling space. In case of the balcony expansion at the floor, however, it is difficult to exclude a possibility of bringing about internal condensation due to the difference of temperature between indoor air and outdoor air caused by the Inflow of outer low-temperature air through the upper part of ceilings by failure in completely putting together the outer composite wall panels on the aluminum curtain walls installed at outer walls This study is to forecast possible occurrence of internal condensation around parapets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation, which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature

Thermoelectric Composites Based on Carbon Nanotubes and Micro Glass Bubbles (탄소나노튜브 및 마이크로 글래스 버블 기반 열전 복합재)

  • Kang, Gu-Hyeok;Seong, Kwangwon;Kim, Myungsoo;Kim, In Guk;Bang, In Cheol;Park, Hyung Wook;Park, Young-Bin
    • Composites Research
    • /
    • v.28 no.2
    • /
    • pp.70-74
    • /
    • 2015
  • In this paper, carbon nanotubes (CNTs) and micro glass bubbles (GBs) have been incorporated into a polyamide6 (PA6) matrix to impart thermoelectric properties. The spaces created in the matrix by GBs allows the formation of "segregated" CNT network. The tightly bound CNT network, if controlled properly, can serve as a conductive path for electron transport, while prohibiting phonon transport, which would provide an ideal configuration for thermoelectric applications. The CNTs and GBs were dispersed in a nylon-formic acid solution using horn sonication followed by coagulation in deionized water, and nanocomposite panels were fabricated using a hot press. The performance of nanocomposite panels was evaluated from thermal and electrical conductivities and Seebeck coefficient, and a thermoelectric figure of merit as high as 0.016 was achieved.

Cyclic testing of chevron braced steel frames with IPE shear panels

  • Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.19 no.5
    • /
    • pp.1167-1184
    • /
    • 2015
  • Despite considerable life casualty and financial loss resulting from past earthquakes, many existing steel buildings are still seismically vulnerable as they have no lateral resistance or at least need some sort of retrofitting. Passive control methods with decreasing seismic demand and increasing ductility reduce rate of vulnerability of structures against earthquakes. One of the most effective and practical passive control methods is to use a shear panel system working as a ductile fuse in the structure. The shear Panel System, SPS, is located vertically between apex of two chevron braces and the flange of the floor beam. Seismic energy is highly dissipated through shear yielding of shear panel web while other elements of the structure remain almost elastic. In this paper, lateral behavior and related benefits of this system with narrow-flange link beams is experimentally investigated in chevron braced simple steel frames. For this purpose, five specimens with IPE (narrow-flange I section) shear panels were examined. All of the specimens showed high ductility and dissipated almost all input energy imposed to the structure. For example, maximum SPS shear distortion of 0.128-0.156 rad, overall ductility of 5.3-7.2, response modification factor of 7.1-11.2, and finally maximum equivalent viscous damping ratio of 35.5-40.2% in the last loading cycle corresponding to an average damping ratio of 26.7-30.6% were obtained. It was also shown that the beam, columns and braces remained elastic as expected. Considering this fact, by just changing the probably damaged shear panel pieces after earthquake, the structure can still be continuously used as another benefit of this proposed retrofitting system without the need to change the floor beam.

Impact Resistance Properties of High Strength Fiber-Reinforced Composites According to Types and Amounts of Fibers (섬유 종류 및 혼입량에 따른 고강도 섬유보강 복합재료의 충돌 저항 성능)

  • Choi, Jeong-Il;Park, Se-Eon;Kim, Gyu-Yong;Lee, Sang-Kyu;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.349-355
    • /
    • 2020
  • The purpose of this study is to investigate the effects of types and amounts of fibers on the compressive strength and tensile behavior high strength fiber-reinforced composites under a static load and impact resistance properties of composites under a high-velocity projectile impact load. Three kinds of mixtures were designed and specimens were manufactured. compressive strength, uniaxial tension, and high velocity projectile impact load tests were performed. Test results showed that the amount of fiber has a greater effect on the tensile strength an d tensile strain capacity than the compressive strength, an d the tensile strain capacity was improved by using hybrid fibers. It was also found that the amount of steel fiber had a great influence on the impact resistance capacity of panels. Although the impact resistance capacity of panels could be improved by using hybrid fibers, the difference of impact resistance capacity between specimens was found to be larger than the case of use of single fiber.

Simulation of Solar Irradiance Distribution Under Agrivoltaic Facilities (영농형 태양광 발전 시설 하부의 일사량 분포 모의)

  • Jeong, Young-Joon;Lee, Sang-Ik;Lee, Jong-Hyuk;Seo, Byung-Hun;Kim, Dong-Su;Lee, Jimin;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.2
    • /
    • pp.1-13
    • /
    • 2022
  • Agrivoltaic facility is the composite system that the solar panel is installed above the farmland, and it enables crop and electricity production simultaneously. Solar panels of the agrivoltaic facilities can block and reduce the amount of solar irradiance arriving at the farmland, but it can help the crop growth by preventing excessive solar irradiance. Therefore, to clarify how the agrivoltaic facilities affect the crop growth, precise solar irradiance distribution under the solar panel should be modeled. In this study, PAR (photosynthetically active radiation), radiation from 400 to 700 nm, which crops usually use to grow, was extracted from the total irradiance and its distribution model under various conditions was developed. Monthly irradiance distributions varied because the elevation of the sun was changed over time, which made the position changed that the local maximum and minimum irradiance appear. The higher panel height did not cause any significant difference in the amount of irradiance reaching below the solar panel, but its distribution became more uniform. Furthermore, the panel angles with the most irradiance arriving below the solar panel were different by month, but its difference was up to 2%p between the irradiance with 30° angle which is usually recommended in Korea. Finally, the interval between panels was adjusted; when the ratio of the length of the panel to the empty space was 1:2, the irradiance of 0.719 times was reached compared to when there was no panel, 0.579 times for 1:1 and 0.442 times for 2:1.

An Experimental Study on the Behavior of Curved Panel Parts Using Composite Materials (복합소재를 활용한 곡면 패널의 부재단위 성능 평가)

  • Park, Hee Beom;Park, Jong-Sup;Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.474-480
    • /
    • 2018
  • FRP is a new material that is lightweight, has high strength and high durability, and is emerging as a third construction material in many countries. The composite material panel targeted in this study was a curved member and is the most frequently used arch-shaped member of a structures, such as tunnels. Composite curved panels can be produced in high quality and large quantities through automation operations. On the other hand, the frequency of application is low, and the design criteria and experimental data are lacking. Therefore, this study examined the mechanical performance of the member unit first to verify its performance as structural members of the FRP curved panel. For this purpose, tensile, compression, and connection performance tests were carried out. The tensile tests showed greater tensile strength of specimens with larger curvature, and the compression tests showed that the composite section of a composite material has greater compressive strength than the concrete section. Finally, the test of the performance of the connection showed that the attachment performance of the connection was more than equal to that of the FRP composite material panel.