• Title/Summary/Keyword: composite element

Search Result 3,065, Processing Time 0.029 seconds

A Boundary-layer Stress Analysis of Laminated Composite Beams via a Computational Asymptotic Method and Papkovich-Fadle Eigenvector (전산점근해석기법과 고유벡터를 이용한 복합재료 보의 경계층 응력 해석)

  • Sin-Ho Kim;Jun-Sik Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.1
    • /
    • pp.41-47
    • /
    • 2024
  • This paper utilizes computational asymptotic analysis to compute the boundary layer solution for composite beams and validates the findings through a comparison with ANSYS results. The boundary layer solution, presented as a sum of the interior solution and pure boundary layer effects, necessitates a mathematically rigorous formalization for both interior and boundary layer aspects. Computational asymptotic analysis emerges as a robust technique for addressing such problems. However, the challenge lies in connecting the boundary layer and interior solutions. In this study, we systematically separate the principles of virtual work and the principles of Saint-Venant to tackle internal and boundary layer issues. The boundary layer solution is articulated by calculating the Papkovich-Fadle eigenfunctions, representing them as linear combinations of real and imaginary vectors. To address warping functions in the interior solutions, we employed a least squares method. The computed solutions exhibit excellent agreement with 2D finite element analysis results, both quantitatively and qualitatively. This validates the effectiveness and accuracy of the proposed approach in capturing the behavior of composite beams.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.

Performance Analysis of LIPCA Actuator considering Material Non-linearity of embedded PZT wafer (압전 세라믹의 재료 비선형성을 고려한 LIPCA 작동기의 성능 해석)

  • Lee, Sang-Ki;Kim, Young-Sung;Park, Hoon-Cheol;Yoon, Kwang-Joon;Goo, Nam-Seo;Cho, Chahng-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.37-44
    • /
    • 2004
  • This paper deals with the performance analysis of LIPCA(Light-weight Piezo-Composite actuator) including the material nun-linearity of the embedded 3203HD PZT wafer. For this analysis, we used a piezo-shell element code based on a nine-node assumed strain shell element formulation. The material non-linearity was implemented in the formulation due to a large observed discrepancy between the measured displacement and the computed actuation displacement based on the linear analysis. An experimentally extracted piezo-strain function of the PZT wafer and incremental formulation were incorporated into the linear finite element code to improve the accuracy of the estimated actuation displacement of the LIPCA. The non-linear piezo-shell program was used to predict the non-linear performance of the LIPCA. The simulated actuation displacement from the non-linear code showed much better agreement with the measured data.

Ambient vibration testing of Berta Highway Bridge with post-tension tendons

  • Kudu, Fatma Nur;Bayraktar, Alemdar;Bakir, Pelin Gundes;Turker, Temel;Altunisik, Ahmet Can
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.21-44
    • /
    • 2014
  • The aim of this study is to determine the dynamic characteristics of long reinforced concrete highway bridges with post-tension tendons using analytical and experimental methods. It is known that the deck length and height of bridges are affected the dynamic characteristics considerably. For this purpose, Berta Bridge constructed in deep valley, in Artvin, Turkey, is selected as an application. The Bridge has two piers with height of 109.245 m and 85.193 m, and the total length of deck is 340.0 m. Analytical and experimental studies are carried out on Berta Bridge which was built in accordance with the balanced cantilever method. Finite Element Method (FEM) and Operational Modal Analysis (OMA) which considers ambient vibration data were used in analytical and experimental studies, respectively. Finite element model of the bridge is created by using SAP2000 program to obtain analytical dynamic characteristics such as the natural frequencies and mode shapes. The ambient vibration tests are performed using Operational Modal Analysis under wind and human loads. Enhanced Frequency Domain Decomposition (EFDD) and Stochastic Subspace Identification (SSI) methods are used to obtain experimental dynamic characteristics like natural frequencies, mode shapes and damping ratios. At the end of the study, analytical and experimental dynamic characteristic are compared with each other and the finite element model of the bridge was updated considering the material properties and boundary conditions. It is emphasized that Operational Modal Analysis method based on the ambient vibrations can be used safely to determine the dynamic characteristics, to update the finite element models, and to monitor the structural health of long reinforced concrete highway bridges constructed with the balanced cantilever method.

Stability Analysis of Waste Landfill Using Multi-interface Element Numerical Method (복합 경계면요소 수치해석에 의한 매립지 안정성 해석)

  • 장연수;김홍석
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.4
    • /
    • pp.29-38
    • /
    • 2004
  • A finite element nonlinear stress-deformation model with multi-interface element is applied to the stability analysis of waste landfill slope. Strength parameters of waste and geosynthetic materials are obtained from the triaxial test of waste and the direct shear test of geosynthetics, respectively. The landfill models used for the numerical models are fit to regulations of the Korean waste management law. The results of the strength tests showed linear behavior for the waste and nonlinear behavior for the eosynthectic materials. The stability analysis with multi-interface element for the geosynthetic materials in the liner system showed large shear stress and slippage at the boundary of the foundation and the slope of the waste fill. This analysis verified the necessity of multi-interface analysis for waste landfills with composite liners.

Modal testing and finite element model calibration of an arch type steel footbridge

  • Bayraktar, Alemdar;Altunisk, Ahmet Can;Sevim, Baris;Turker, Temel
    • Steel and Composite Structures
    • /
    • v.7 no.6
    • /
    • pp.487-502
    • /
    • 2007
  • In recent decades there has been a trend towards improved mechanical characteristics of materials used in footbridge construction. It has enabled engineers to design lighter, slender and more aesthetic structures. As a result of these construction trends, many footbridges have become more susceptible to vibrations when subjected to dynamic loads. In addition to this, some inherit modelling uncertainties related to a lack of information on the as-built structure, such as boundary conditions, material properties, and the effects of non-structural elements make difficult to evaluate modal properties of footbridges, analytically. For these purposes, modal testing of footbridges is used to rectify these problems after construction. This paper describes an arch type steel footbridge, its analytical modelling, modal testing and finite element model calibration. A modern steel footbridge which has arch type structural system and located on the Karadeniz coast road in Trabzon, Turkey is selected as an application. An analytical modal analysis is performed on the developed 3D finite element model of footbridge to provide the analytical frequencies and mode shapes. The field ambient vibration tests on the footbridge deck under natural excitation such as human walking and traffic loads are conducted. The output-only modal parameter identification is carried out by using the peak picking of the average normalized power spectral densities in the frequency domain and stochastic subspace identification in the time domain, and dynamic characteristics such as natural frequencies mode shapes and damping ratios are determined. The finite element model of footbridge is calibrated to minimize the differences between analytically and experimentally estimated modal properties by changing some uncertain modelling parameters such as material properties. At the end of the study, maximum differences in the natural frequencies are reduced from 22% to only %5 and good agreement is found between analytical and experimental dynamic characteristics such as natural frequencies, mode shapes by model calibration.

An Analysis of the Reinforced Concrete Circular Ring Sector Plates with Arbitrary Boundary Conditions (任意의 境界條件을 갖는 鐵筋콘크리트 扇形板의 解析(II) - 第 2報 鐵筋比 및 邊長比의 影響 -)

  • Jo, Jin-Gu
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.1
    • /
    • pp.78-86
    • /
    • 1992
  • This paper aims at investigating the effect of steel ratio and the magnitude of edge-ratio on the mechanical characteristics of reinforced concrete ring sector plate. The influence of steel bars was taken into account by coupling stiffness matrix of the steel bar element with that of the concrete plate element without dealing with separate element of steel bar and by establishing the composite stiffness matrix, which leads to the desirable result which does not increase th number of element could be obtained. Through case studies with 6 cases various steel ratios in ring sector plate supported at four edges and 4 cases with different open angles, the influence of the steel ratio was examined. A numerical analysis to find out the effect of the steel ratio d ue to above mentioned cases was carried out by 4 boundary conditions ; all edges clamped (B.C-1), all edges simply supported (B.C-2), curvilinear two edges clamped and other edges free (B.C-3) and curvilinear two edges simply supported and other edges free(B.C-4). The main results obtained are summarized as follows : 1. The effect of steel ratio on the magnitude of lateral deflection and x-directional bending moment at the center of sector plate and the midpoint of outer and inner curvilinear edges is almost the same up to $30^{\circ}$ of open angle. Beyond $30^{\circ}$ of the angle, the larger the angle, the greater the effect of ratio. 2. In design works using balanced steel ratio, the effect of steel bar can be ignored. But for larger open angles, especially greater than $90^{\circ}$, it proves desirable to consider the effect of steel bar. 3. The effect of the arc length of center circle/straight edge on lateral deflection and bending moment is remarkable in B.C-2. For larger open angle, the effect is also noted except for B.C-3 which turn out hardly affected. 4. The effect of the radius of curvature/straight side length on lateral deflection and x-directional bending moment is noted in B.C-2. As open angle increases, B.C-1 and B.C-3 almost agree and B.C-2 approaches B.C-4.

  • PDF

Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections

  • Roy, Krishanu;Ting, Tina Chui Huon;Lau, Hieng Ho;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.233-250
    • /
    • 2018
  • Back-to-back built-up cold-formed steel un-lipped channel sections are used in cold-formed steel structures; such as trusses, wall frames and portal frames. In such built-up columns, intermediate fasteners resist the buckling of individual channel-sections. No experimental tests or finite element analyses have been reported in the literature for back-to-back built-up cold-formed steel un-lipped channel sections and specially investigated the effect of screw spacing on axial strength of such columns. The issue is addressed in this paper. The results of 95 finite element analyses are presented covering stub to slender columns. The finite element model is validated against the experimental tests recently conducted by authors for back-to-back built-up cold-formed steel lipped channel sections. The verified finite element model is then used for the purposes of a parametric study to investigate the effect of screw spacing on axial strength of back-to-back built-up cold-formed steel un-lipped channel sections. Results are compared against the built-up lipped channel sections and it is shown that the axial strength of un-lipped built-up sections are 31% lesser on average than the built-up lipped channel sections. It was also found that the American Iron and Steel Institute (AISI) and the Australian and New Zealand Standards were over-conservative by around 15% for built-up columns failed through overall buckling, however AISI and AS/NZS were un-conservative by around 8% for built-up columns mainly failed by local buckling.

Numerical study of steel sandwich plates with RPF and VR cores materials under free air blast loads

  • Rashad, Mohamed;Yang, T.Y.
    • Steel and Composite Structures
    • /
    • v.27 no.6
    • /
    • pp.717-725
    • /
    • 2018
  • One of the most important design criteria in military tunnels and armoured doors is to resist the blast loads with minimum structural weight. This can be achieved by using steel sandwich panels. In this paper, the nonlinear behaviour of steel sandwich panels, with different core materials: (1) Hollow (no core material); (2) Rigid Polyurethane Foam (RPF); and (3) Vulcanized Rubber (VR) under free air blast loads, was investigated using detailed 3D nonlinear finite element models in Ansys Autodyn. The accuracy of the finite element model proposed was verified using available experimental test data of a similar steel sandwich panel tested. The results show the developed finite element model can be reliably used to simulate the nonlinear behaviour of the steel sandwich panels under free air blast loads. The verified finite element model was used to examine the different parameters of the steel sandwich panel with different core materials. The result shows that the sandwich panel with RPF core material is more efficient than the VR sandwich panel followed by the Hollow sandwich panels. The average maximum displacement of RPF sandwich panel under different ranges of TNT charge (1 kg to 10 kg at a standoff distance of 1 m) is 49% and 53% less than the VR and Hollow sandwich panels, respectively. Detailed empirical design equations were provided to quantify the maximum deformation of the steel sandwich panels with different core materials and core thickness under a different range of blast loads. The developed equations can be used as a guide for engineer to design steel sandwich panels with RPF and VR core material under a different range of free air blast loads.

Investigation on SCFs of concrete-filled circular chord and square braces K-joints under balanced axial loading

  • Chen, Yu;Hu, Kang;Yang, Jian
    • Steel and Composite Structures
    • /
    • v.21 no.6
    • /
    • pp.1227-1250
    • /
    • 2016
  • Most of the research work has been conducted on K-joints under static loading. Very limited information is available in consideration of fatigue strength of K-joints with concrete-filled chord. This paper aims to describe experimental and numerical investigations on stress concentration factors (SCFs) of concrete-filled circular chord and square braces K-joints under balanced axial loading. Experiment was conducted to study the hot spot stress distribution along the intersection of chord and braces in the two specimens with compacting concrete filled in the chord. The test results of stress distribution curves of two specimens were reported. SCFs of concrete-filled circular chord and square braces K-joints were lower than those of corresponding hollow circular chord and square brace K-joints. The corresponding finite element analysis was also conducted to simulate stress distribution along the brace and chord intersection region of joints. It was achieved that experimental and finite element analysis results had good agreement. Therefore, an extensive parametric study was carried out by using the calibrated finite element model to evaluate the effects of main geometric parameters and concrete strength on the behavior of concrete-filled circular chord and square braces K-joints under balanced axial loading. The SCFs at the hot spot locations obtained from ABAQUS were compared with those calculated by using design formula given in the CIDECT for hollow SHS-SHS K-joints. CIDECT Design Guide was generally quite conservative for predicting SCFs of braces and was dangerous for predicting SCFs of chord in concrete-filled circular chord and square braces K-joints. Finally SCF formulae were proposed for circular chord and square braces K-joints with concrete-filled in the chord under balanced axial loading. It is shown that the SCFs calculated from the proposed design equation are generally in agreement with the values derived from finite element analysis, which were proved to be reliable and accurate.