• Title/Summary/Keyword: composite design index

Search Result 171, Processing Time 0.035 seconds

Gross Profitability Premium in the Korean Stock Market and Its Implication for the Fund Distribution Industry (한국 주식시장에서 총수익성 프리미엄에 관한 분석 및 펀드 유통산업에 주는 시사점)

  • Yoon, Bo-Hyun;Liu, Won-Suk
    • Journal of Distribution Science
    • /
    • v.13 no.9
    • /
    • pp.37-45
    • /
    • 2015
  • Purpose - This paper's aim is to investigate whether or not gross profitability explains the cross-sectional variation of the stock returns in the Korean stock market. Gross profitability is an alternative profitability measure proposed by Novy-Marx in 2013 to predict cross-sectional variation of stock returns in the US. He shows that the gross profitability adds explanatory power to the Fama-French 3 factor model. Interestingly, gross profitability is negatively correlated with the book-to-market ratio. By confirming the gross profitability premium in the Korean stock market, we may provide some implications regarding the well-known value premium. In addition, our empirical results may provide opportunities for the fund distribution industry to promote brand new styles of funds. Research design, data, and methodology - For our empirical analysis, we collect monthly market prices of all the companies listed on the Korea Composite Stock Price Index (KOSPI) of the Korea Exchanges (KRX). Our sample period covers July1994 to December2014. The data from the company financial statementsare provided by the financial information company WISEfn. First, using Fama-Macbeth cross-sectional regression, we investigate the relation between gross profitability and stock return performance. For robustness in analyzing the performance of the gross profitability strategy, we consider value weighted portfolio returns as well as equally weighted portfolio returns. Next, using Fama-French 3 factor models, we examine whether or not the gross profitability strategy generates excess returns when firmsize and the book-to-market ratio are controlled. Finally, we analyze the effect of firm size and the book-to-market ratio on the gross profitability strategy. Results - First, through the Fama-MacBeth cross-sectional regression, we show that gross profitability has almost the same explanatory power as the book-to-market ratio in explaining the cross-sectional variation of the Korean stock market. Second, we find evidence that gross profitability is a statistically significant variable for explaining cross-sectional stock returns when the size and the value effect are controlled. Third, we show that gross profitability, which is positively correlated with stock returns and firm size, is negatively correlated with the book-to-market ratio. From the perspective of portfolio management, our results imply that since the gross profitability strategy is a distinctive growth strategy, value strategies can be improved by hedging with the gross profitability strategy. Conclusions - Our empirical results confirm the existence of a gross profitability premium in the Korean stock market. From the perspective of the fund distribution industry, the gross profitability portfolio is worthy of attention. Since the value strategy portfolio returns are negatively correlated with the gross profitability strategy portfolio returns, by mixing both portfolios, investors could be better off without additional risk. However, the profitable firms are dissimilar from the value firms (high book-to-market ratio firms); therefore, an alternative factor model including gross profitability may help us understand the economic implications of the well-known anomalies such as value premium, momentum, and low volatility. We reserve these topics for future research.

Functionalities of Squid Liver Hydrolysates (오징어 간 가수분해물의 기능성)

  • Lee, Su-Seon;Park, Si-Hyang;Park, Joo-Dong;Konno, Kunihiko;Choi, Yeung Joon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1677-1685
    • /
    • 2012
  • The autolysate and hydrolysate of a common squid liver, Todarodes pacificus, were prepared. Autolysis (liver ratio, pH, temperature) and Protamex-treated hydrolysis (pH, temperature, ratio of protease to liver) conditions were optimized by response surface methodology using central composite design for under 1 hr of hydrolysis time. The desirability profile indicated that maximum DH could be achieved at a squid liver of 93.5%, pH 6.4, and $47^{\circ}C$ in autolysis, while that of Protamex-treated hydrolysis did at a Protamex-to-squid liver level of 0.33%, pH 6.0, and $55^{\circ}C$. Three amino acids, proline, cysteine, and methionine, were not detected in the total amino acid composition of the Protamex-treated hydrolysate, while they were detected in the free amino acid composition. Cadmium was $8.32{\pm}0.03$ mg/100 g-powder for raw, $3.56{\pm}0.02$ mg/100 g-powder for the autolysate, and $13.26{\pm}0.04$ mg/100 g powder for the Protamex-treated hydrolysate. The major molecular weight ranged from 1.0 to 1.5 kDa for the autolysate and from 210 to 470 Da for the Protamex-treated hydrolysate. Food functionalities of the autolysate, such as surface hydrolphobicity, emulsion activity index, emulsion stability, water, and fat adsorption, were similar to the Protamex-treated hydrolysate. Both the autolysate and Protamex-hydrolysate showed high inhibitory activities on the angiotensin-I converting enzyme. Cell toxicity against the HepG2 cell line was not detected in the autolysate or the Protamex-treated hydrolysate by 200 ${\mu}g/mL$.

Quality Characteristics and Reduced Sugar Conditions of Yanggaeng Prepared with Steamed Liriopis Tuber Extract Using Response Surface Methodology (반응표면분석법을 이용한 증숙 맥문동 첨가 양갱의 품질 특성 및 당류 저감화 조건 연구)

  • Park, Chanyoung;Park, So Hae;Kim, Won Baek;Hwang, Ji Hoe;Lee, Heeseob
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.2
    • /
    • pp.229-236
    • /
    • 2017
  • This study was performed to optimize yanggaeng processing conditions prepared with different amounts of steamed Liriopis tuber (SLT) extract, sugar, and agar powder using response surface methodology. The experimental conditions were designed according to the central composite design with 16 experimental points, including two replicates for three independent variables. The experimental data on physicochemical properties, textural properties, and sensory evaluation were fitted to various models, and the accuracy of the equations was analyzed by ANOVA. Among the responses, pH, water content, sugar content, L-value, browning index, chewiness, gumminess, and sensory properties of appearance, color, sweetness, hardness, texture, and overall acceptability showed significant correlation with contents of SLT, sugar, and agar powder. From these results, optimum formulation of yanggaeng was calculated as follows: SLT 35 mL, sugar 55.23 g, and agar powder 3.39 g.

Optimization for Maillard Reaction Substrate Conditions of Ribose and Hydrolyzed Wheat Gluten Solution Using Response Surface Methodology (반응표면분석법을 이용한 Ribose와 소맥 글루텐 산 가수분해물의 마이얄 반응기질 조건 최적화)

  • Moon, Ji-Hye;Choi, Hee-Don;Choi, In-Wook;Kim, Yoon-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.3
    • /
    • pp.458-465
    • /
    • 2011
  • Response surface methodology (RSM) was applied to optimize substrate conditions of ribose and hydrolyzed wheat gluten solution for Maillard reaction. Independent variables were NaCl concentration of hydrolyzed wheat gluten ($X_1$), concentration of ribose ($X_2$) and concentration of hydrolyzed wheat gluten ($X_3$), while the dependent variables of the central composite design (CCD) were browning index (absorbance 420 nm), DPPH radical scavenging activity (DF) and sensory preference (score). Optimum substrate conditions at $140^{\circ}C$, 30 min reaction were 3% NaCl concentration of hydrolyzed wheat gluten, 6.2% concentration of ribose and 13.27% concentration of hydrolyzed wheat gluten. The coefficients of determination ($R^2$) were 0.975, 0.960 and 0.854, the model fit was very significant (p<0.001). DPPH radical scavenging activities and sensory preferences were predicted as 700 (DF) and 8.42 (score), respectively. The model solution increased more browning and DPPH radical scavenging activities with increasing ribose and hydrolyzed wheat gluten concentration. Especially hydrolyzed wheat gluten concentration was the most influential factor, while NaCl concentration of hydrolyzed wheat gluten hardly affected the responses. Sensory preference was increased with rising wheat gluten concentration and decreasing NaCl concentration of hydrolyzed wheat gluten.

Preparation of Cosmeceuticals Containing Wheat Sprout Extracts: Optimization of Emulsion Stability Using CCD-RSM (밀싹 추출물이 함유된 Cosmeceuticals의 제조: CCD-RSM을 이용한 유화안정성 최적화)

  • Jang, Hyun Sik;Ma, Xixiang;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.320-325
    • /
    • 2021
  • In this study, an optimization for the production of water emulsion was designed by adding an extract of wheat sprout, which is known to contain a large amount of antioxidants. The central composite design of reaction surface analysis method (CCD-RSM) was used for the optimization process. The amount of emulsifier, emulsification time, and added amount of wheat sprout extract were selected as independent variables based on our preliminary experiments. The mean droplet size (MDS), viscosity, and emulsion stability index (ESI) were set as the responses to evaluate the stability of the emulsion. For each independent variable, the P-value and coefficient of determination were evaluated to verify the reliability of the experiments. From the result of CCD-RSM, optimum conditions for the emulsification were determined as 23.6 min, 7.7 wt.%, and 3.9 wt.% for the emulsification time, amount of emulsifier, and amount of sprout, respectively. From the optimized condition obtained, MDS, viscosity, and ESI after 7 days from reaction were estimated as 252.3 nm, 616.7 cP, and 88.7%, respectively. The overall satisfaction was 0.9137, which supported the validity of the experiments, and the error rate was measured at 0.5% or less by advancing the experiments. Therefore, an optimized process for producing an emulsion by adding the malt extract was designed by the CCD-RSM.

Reliability of mortar filling layer void length in in-service ballastless track-bridge system of HSR

  • Binbin He;Sheng Wen;Yulin Feng;Lizhong Jiang;Wangbao Zhou
    • Steel and Composite Structures
    • /
    • v.47 no.1
    • /
    • pp.91-102
    • /
    • 2023
  • To study the evaluation standard and control limit of mortar filling layer void length, in this paper, the train sub-model was developed by MATLAB and the track-bridge sub-model considering the mortar filling layer void was established by ANSYS. The two sub-models were assembled into a train-track-bridge coupling dynamic model through the wheel-rail contact relationship, and the validity was corroborated by the coupling dynamic model with the literature model. Considering the randomness of fastening stiffness, mortar elastic modulus, length of mortar filling layer void, and pier settlement, the test points were designed by the Box-Behnken method based on Design-Expert software. The coupled dynamic model was calculated, and the support vector regression (SVR) nonlinear mapping model of the wheel-rail system was established. The learning, prediction, and verification were carried out. Finally, the reliable probability of the amplification coefficient distribution of the response index of the train and structure in different ranges was obtained based on the SVR nonlinear mapping model and Latin hypercube sampling method. The limit of the length of the mortar filling layer void was, thus, obtained. The results show that the SVR nonlinear mapping model developed in this paper has a high fitting accuracy of 0.993, and the computational efficiency is significantly improved by 99.86%. It can be used to calculate the dynamic response of the wheel-rail system. The length of the mortar filling layer void significantly affects the wheel-rail vertical force, wheel weight load reduction ratio, rail vertical displacement, and track plate vertical displacement. The dynamic response of the track structure has a more significant effect on the limit value of the length of the mortar filling layer void than the dynamic response of the vehicle, and the rail vertical displacement is the most obvious. At 250 km/h - 350 km/h train running speed, the limit values of grade I, II, and III of the lengths of the mortar filling layer void are 3.932 m, 4.337 m, and 4.766 m, respectively. The results can provide some reference for the long-term service performance reliability of the ballastless track-bridge system of HRS.

Correlation Analysis between Injury Index of Multi-cell Headrest through k-means Clustering DB (k-means clustering DB를 통한 Multi-cell headrest의 상해지수 간 상관관계 분석)

  • Sungwook Cho;Seong S. Cheon
    • Composites Research
    • /
    • v.37 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The development of transportation methods has improved human transportation convenience and made it possible to expand the travel radius of people with disabilities who have difficulty moving. However, in the case of WAV (wheelchair Accessible Vehicle), the safety that may occur in a vehicle accident is still lower than that of regular passenger seats. In particular, in the case of a rear-end collision that may occur in a defenseless situation, it can cause fatal neck injuries to disabled passengers. Therefore, a more detailed design plan must be reflected in the headrest to be applied to WAV. In this study, a multi-cell headrest was proposed to implement local compression characteristic distribution of the headrest during rear-end collision of WAV. Afterwards, a correlation analysis was performed between the passenger's NIC (Neck Injury Criterion) and impact energy absorption using the data set construction through analysis and the clustering results using k-means clustering. As a result of clustering, it was confirmed that data clusters with similar characteristics were formed, and a correlation analysis between NIC and impact energy absorption through the characteristics of each cluster was performed. As a result of the analysis, it was confirmed that the softer the cell compression characteristics in Mid3 and Mid6, the more impact energy absorption increases, and the harder the cell compression characteristics in Front2, Mid3, and Mid6, the more effective it is in reducing NIC.

Preparation of Cosmeceuticals Containing Scutellaria baicalensis Extracts: Optimization of Emulsion Stability and Antibacterial Property (황금추출물이 함유된 Cosmeceuticals의 제조: 유화안정성 및 항균특성 최적화)

  • Seheum Hong;Young Woo Choi;Wenjia Xu;Seung Bum Lee
    • Applied Chemistry for Engineering
    • /
    • v.35 no.4
    • /
    • pp.316-320
    • /
    • 2024
  • To optimize the emulsion stability and antibacterial activity against Escherichia coli (E. coli) of cosmeceuticals using Scutellaria baicalensis extracts and olive wax as natural emulsifiers, we conducted a study. The independent variables were the amounts of Scutellaria baicalensis extracts and olive wax added. The response variables included the emulsion stability index (ESI) of the cosmeceuticals product and the inhibition diameter against E. coli. Through central composite design-response surface methodology (CCD-RSM), we obtained a statistically significant and reliable regression equation within a 95% confidence interval. By optimizing multiple responses, we determined that the optimal emulsification conditions that satisfied both ESI and E. coli inhibition diameter were 3.7 wt% of Scutellaria baicalensis extracts and 2.7 wt% of olive wax. The predicted ESI and E. coli inhibition diameter were 97.9% and 9.7 mm, respectively. When actual experiments were conducted under the optimal conditions, the measured ESI and E. coli inhibition diameter were 95.0% and 9.4 mm, respectively, with an average error rate of 3.2 ± 0.4%.

Effects of Optimized Co-treatment Conditions with Ultrasound and Low-temperature Blanching Using the Response Surface Methodology on the Browning and Quality of Fresh-cut Lettuce (반응표면분석법으로 최적화한 초음파와 저온 블랜칭의 병용처리 조건이 신선편이 양상추의 갈변과 품질에 미치는 영향)

  • Kim, Do-Hee;Kim, Su-Min;Kim, Han-Bit;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.19 no.4
    • /
    • pp.470-476
    • /
    • 2012
  • Enzymatic action and microbial growth degrade the quality of fresh-cut lettuce. Browning, a bad smell, and softening during storage are the major forms of quality deterioration. Health-oriented consumers tend to avoid foods treated with chemicals to maintain their freshness. This study was conducted to evaluate the change in the quality of fresh-cut lettuce with combined low-temperature blanching (LB) and ultrasonication (US). The optimum condition was selected using the response surface methodology (RSM), through a regression analysis with the following independent variables; the ultrasonication time (X1), blanching temperature (X2), blanching time (X3), and dependent variable; ${\Delta}E$ value (y). It was found that the condition with the lowest ${\Delta}E$ value occurred with combined 90s US and $45^{\circ}C$ 90s LB (US+LB). The combined treatment group (US+LB) was stored at $10^{\circ}C$ for 9 days with the control group and each single-treatment group, with low-temperature blanching and ultrasonication. Overall, the US+LB group had a significantly high $L^*$ value, which indicates significantly low $a^*$, $b^*$, ${\Delta}E$, browning index, PPO, and POD activity values, and a low total bacteria count (p < 0.05). The US+LB group also had the highest sensory score (except for aroma and texture; p > 0.05).

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF