• Title/Summary/Keyword: component testing

Search Result 592, Processing Time 0.031 seconds

A Study on the Characteristics of Ion, Carbon, and Elemental Components in PM2.5 at Industrial Complexes in Ansan and Siheung (안산·시흥 산업단지 지역 PM2.5 중 이온, 탄소, 원소성분의 특성 연구)

  • Lee, Hye-Won;Lee, Seung-Hyeon;Jeon, Jeong-In;Lee, Jeong-Il;Lee, Cheol-Min
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.2
    • /
    • pp.66-74
    • /
    • 2022
  • Background: The health effects of particulate matter (PM2.5) bonded with various harmful chemicals differ based on their composition, so investigating and managing their concentrations and composition is vital for long-term management. As industrial complexes emit considerable quantities of pollutants, higher PM2.5 concentrations and chemical component effects are expected than in other places. Objectives: We investigated the concentration distribution ratios of PM2.5 chemical components to provide basic data to inform future major emissions control and PM2.5 reduction measures in industrial complexes. Methods: We monitored five sites near the Ansan and Siheung industrial complexes from August 2020 to July 2021. Samples were collected and analyzed twice per week in spring/winter and once per week in summer/autumn according to the National Institute of Environmental Research in the Ministry of Environments' Air Pollution Monitoring Network Installation and Operation Guidelines. We investigated and compared composition ratios of 29 ions, carbon, and elemental components in PM2.5. Results: The analysis of PM2.5 components at the five sites revealed that ion components accounted for the greatest total mass at approximately 50% while carbon components and elemental components contributed 23~28% and 8~10%, respectively. Among the ionic components, NO3- occupies the greatest proportion. OC occupies the greatest proportion of the carbon components and sulphur occupies the greatest proportion of elemental components. Conclusions: This study investigated the concentration distribution ratios of PM2.5 chemical components in industrial complexes. We believe these results provide basic chemical component concentration ratio data for establishing future air management policies and plans for the Ansan and Siheung industrial complexes.

Parameter estimation and assessment of bias in genetic evaluation of carcass traits in Hanwoo cattle using real and simulated data

  • Mohammed Bedhane;Julius van der Werf;Sara de las Heras-Saldana;Leland Ackerson IV;Dajeong Lim;Byoungho Park;Mi Na Park;Seunghee Roh;Samuel Clark
    • Journal of Animal Science and Technology
    • /
    • v.65 no.6
    • /
    • pp.1180-1193
    • /
    • 2023
  • Most carcass and meat quality traits are moderate to highly heritable, indicating that they can be improved through selection. Genetic evaluation for these types of traits is performed using performance data obtained from commercial and progeny testing evaluation. The performance data from commercial farms are available in large volume, however, some drawbacks have been observed. The drawback of the commercial data is mainly due to sorting of animals based on live weight prior to slaughter, and this could lead to bias in the genetic evaluation of later measured traits such as carcass traits. The current study has two components to address the drawback of the commercial data. The first component of the study aimed to estimate genetic parameters for carcass and meat quality traits in Korean Hanwoo cattle using a large sample size of industry-based carcass performance records (n = 469,002). The second component of the study aimed to describe the impact of sorting animals into different contemporary groups based on an early measured trait and then examine the effect on the genetic evaluation of subsequently measured traits. To demonstrate our objectives, we used real performance data to estimate genetic parameters and simulated data was used to assess the bias in genetic evaluation. The results of our first study showed that commercial data obtained from slaughterhouses is a potential source of carcass performance data and useful for genetic evaluation of carcass traits to improve beef cattle performance. However, we observed some harvesting effect which leads to bias in genetic evaluation of carcass traits. This is mainly due to the selection of animal based on their body weight before arrival to slaughterhouse. Overall, the non-random allocation of animals into a contemporary group leads to a biased estimated breeding value in genetic evaluation, the severity of which increases when the evaluation traits are highly correlated.

Classification of Handwritten and Machine-printed Korean Address Image based on Connected Component Analysis (연결요소 분석에 기반한 인쇄체 한글 주소와 필기체 한글 주소의 구분)

  • 장승익;정선화;임길택;남윤석
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.10
    • /
    • pp.904-911
    • /
    • 2003
  • In this paper, we propose an effective method for the distinction between machine-printed and handwritten Korean address images. It is important to know whether an input image is handwritten or machine-printed, because methods for handwritten image are quite different from those of machine-printed image in such applications as address reading, form processing, FAX routing, and so on. Our method consists of three blocks: valid connected components grouping, feature extraction, and classification. Features related to width and position of groups of valid connected components are used for the classification based on a neural network. The experiment done with live Korean address images has demonstrated the superiority of the proposed method. The correct classification rate for 3,147 testing images was about 98.85%.

Microstructure investigation of iron artifacts excavated from No. 3 tomb of Bogam-ri in Naju City, Chollanam-do Province (나주 복암리 3호분 출토 철제유물의 금속학적 조사)

  • Yu, Jae-Eun;Go, Hyeoung-Sun;Hwong, Jin-Ju
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.115-132
    • /
    • 2001
  • No. 3 Tomb of Bogam-ri, in Naju City, Chollanam-do Province, was a site excavated and inspected from 1996 to 1998 and had a various grave forms, including jar-coffins, stone-chambers and stone-cists. Although most of the metal artifacts excavated from it were severely corroded, we could implement microstructure investigation by collecting samples from the iron axes, iron coffin-nails and iron clamps in which the metal parts were remained. The metal structures were inspected by using metallographic microscope and SEM, and fine components analysis was implemented by ICP. To examine the hardness differences in accordance with the structure distribution, we measured the hardness by structures with Vickers hardness testing machine. As a result of the metal structure inspection, most of them were pure iron, ferrite, and also pearlite, cementite and widmannstaten structures were displayed. We could confirm carbonization was formed on the surface of the iron axes-B, iron coffin-nails-B, and iron clamps-A. There was no carbonization in the rest of the artifacts, and it is not certain that whether the carbonized parts were peeled off through extreme corrosion or they were not carbonized when they were made. In the particular part of a blade, the quality of the material was strengthened through processing. Due to the processing re-grain was caused and fine grain particles were formed. As a result of the ICP component analysis, there were no addition atoms because pure irons were used as materials. In the mean time, No. 17 jar-coffin where the iron axes-A are excavated, is chronologically ordered as from the late-fourth century to the mid-fifth century, and No. 1 and No. 2 stone chambers, where the rest of the artifacts were excavated, as the early-sixth century. It was difficult to relate the periodic differences with the manufacture technique artifacts which we inspected because there were no distinct characteristics of the manufacture technique of the metal structures and it is impossible to conclude the artifacts and sites are at the same period although their periods are different.

  • PDF

Determination of True Stress-Strain Curves of Auto-body Plastics Using FEGM (FEGM을 이용한 자동차용 플라스틱의 진응력-변형률 선도 도출)

  • Park, C.H.;Kim, J.S.;Huh, H.;Ahn, C.N.;Choi, S.J
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.223-226
    • /
    • 2009
  • The plastics are widely utilized in the inside of vehicles. The dynamic tensile characteristics of auto-body plastics are important in a prediction of deformation mode of the plastic component which undergoes the high speed deformation during car crash. This paper is concerned with the dynamic tensile characteristics of the auto-body plastics at intermediate strain rates. Quasi-static tensile tests were carried out at the strain rate ranged from 0.001/sec to 0.01/sec using the static tensile machine(Instron 5583). Dynamic tensile tests were carried out at the strain rate ranged from 0.1/sec to 100/sec using the high speed material testing machine developed. Conventional extensometry method is no longer available for plastics, since the deformation of plastic is accompanied with localized deformation. In this paper, quasi-static and dynamic tensile tests were performed using ASTM IV standard specimens with grids and images from a high speed camera were analyzed for strain measurement. True stress-strain relations and the actual strain rates at each deformation step were obtained by processing load data and deformation images, assuming the plastics to deform uniformly in each grid.

  • PDF

A Study of Testing Procedure Temperature of Electronic Equipment for Railway Environments (Cold and Heat) (철도용 전자기기의 온도환경(내한성, 내열성)에 대한 시험검사 절차에 대한 분석연구)

  • Kim, Jin-Hwan;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.748-753
    • /
    • 2011
  • Generally, in the temperature and environment test of railway electronics, cold and heat resistant tests are involved. Relevant KRS standards describe "There is no problem" as acceptance criteria for function check during the temperature and environment tests. According to this requirement, testers perform some function and performance tests which are easy to perform during test procedure using temperature chamber. This paper reviews the limit of current check method for cold and heat resistant tests and proposes an alternative. An alternative is the application of data sheet. Using data sheet, the temperature of equipped components is checked whether this temperature meet acceptance criteria or not. Also, this paper suggests temperature test range guidelines comparing temperature standards for general IC component. For the example in real field, this method uses the lowest temperature and the highest temperature in major domestic cities.

  • PDF

Psychometric Properties of the Korean Version of the HIV Self-Management Scale in Patients with HIV

  • Kim, Gwang Suk;Chu, Sang Hui;Park, Yunhee;Choi, Jun Yong;Lee, Jeong In;Park, Chang Gi;McCreary, Linda L.
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.3
    • /
    • pp.439-448
    • /
    • 2015
  • Purpose: The purpose of this study was to examine validity and reliability of Webel and colleagues'HIV Self-Management Scale when used with a Korean sample. Methods: The original 20-item HIV Self-Management Scale was translated into Korean using translation and back-translation. Nine HIV nurse experts tested content validity. Principal component analysis (PCA) and confirmatory factor analysis (CFA) of data from 203 patients was used to test construct validity. Concurrent validity was evaluated using correlation with patients'self-rating as a "mart patient"measured using a visual analogue scale. Internal consistency was tested by Cronbach' alpha coefficients. Results: All items were rated as having satisfactory content validity. Based on PCA and consideration of conceptual meaning, a three-factor solution was selected, explaining 48.76% of the variance. CFA demonstrated the adequacy of the three-domain structure of the construct HIV self-management: daily self-management health practices, social support and HIV self-management, and chronic nature of HIV self-management. Goodness-of-fit indices showed an acceptable fit overall with the full model (${\chi}^2/df_{(164)}=1.66$, RMSEA=0.06, SRMR=0.05, TLI=0.91, and CFI=0.92). The Korean version of the HIV Self-Management Scale (KHSMS) was significantly correlated with patients'self-rated smart patient (r=.41). The subscale Cronbach' alpha coefficients ranged from .78 to .81; alpha for the total scale was .89. Conclusion: The KHSMS provides a valid and reliable measure of self-management in Korean patients with HIV. Continued psychometric testing is recommended to provide further evidence of validity with this population.

An Innovative Wellness Program Promoting Participation in Physical Activity of Community-Dwelling Frail Elderly

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.47-56
    • /
    • 2017
  • Background: Given the potential benefits of wellness programs promoting physical activity of the community-dwelling frail elderly, it is recommended that comprehensive wellness programs combined with the component of physical activity. This may improve overall health and potentially lower the health care cost of the frail elderly. In general, the frail elderly residing in community or those after being discharged from hospitals are often committed to enhancing the status of participation in physical activity. Objects: The purposes of this study were to identify specific shortcomings of current wellness programs as part of continuum of community rehabilitation services and to propose alternatives for the care of the community-dwelling frail elderly. Through this study, geriatric health care professionals may be able to implement assessments and programs to successfully promote an effective continuum of care for the frail elderly. Methods: Article reviews were summarized and evaluated. Results: A model elaborating the relationship between components of successful wellness program and participation in physical activities for the community-dwelling frail elderly are recommended. First, periodic monitoring the levels of physical activity by the use of online measurement system should be considered. Second, individualized adaptive technologies for selecting optimal physical activities for the elderly may be better fit to individuals' current status of physical activity. Conclusion: The current status of physical activity in community-dwelling frail elderly can be monitored by online assessment systems. Through the innovative measurement system, elderly may assess his/her physical activity status overtime, select optimal physical activities matching the status, and create the elderly's own adaptive wellness programs that match to the status while residing in his/her community.

Development Rapid Analytical Methods for Inositol as a Trace Component by HPLC and LC-MS/MS in Infant Formula

  • Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.4
    • /
    • pp.466-472
    • /
    • 2015
  • A rapid and simple analytical method, using liquid chromatography tandem mass spectrometry (LC-MS/MS), was developed to detect myo-inositol (MI) in infant formulas. For protein removal: acid hydrolysis and lipid removal through organic solvent extraction. The operating conditions for instrumental analysis were determined based on previously reported analogous methods that used LC-MS/MS. Quantitative analysis was used for the detection limit test, infant formula recovery test, and standard reference material (SRM) 1849a to verify the validity of our LC-MS/MS analytical method, which was developed to quantify MI. For validation, the results of our method were compared with the results of quantitative analyses of certified values. The test results showed that the limit of detection was 0.05 mg/L, the limit of quantitation was 0.17 mg/L, and the method detection limit was 17 mg/kg. The recovery test exhibited a recovery between 98.07-98.43% and a relative standard deviation between 1.93-2.74%. Therefore, the result values were good. Additionally, SRM 1849a was measured to have an MI content of 401.84 mg/kg and recovery of 98.25%, which is comparable to the median certified value of 409 mg/kg. From the aforementioned results, we judged that the instrumental analysis conditions and preparation method used in this study were valid. The rapid analytical method developed herein could be implemented in many laboratories that seek to save time and labor.

Novel Fabrication and Testing of a Bubble-Powered Micropump (새로운 기포동력 마이크로펌프 제작 및 실험)

  • Jung, Jung-Yeul;Kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF