• Title/Summary/Keyword: complex wastewater

Search Result 218, Processing Time 0.039 seconds

A Study on the Reduction of Total Phosphate of the Concerned Pollution Area in the Main Stream of Mangyeong River (만경강 본류 중 오염우심지역의 TP 저감방안 연구)

  • Jounghwa, Choi;Jaeog, Kwon;Miseon, Lee;Wook, Jang;Geunhwa, Choi;Eunhye, Ko;Seohyeon, Sim;Changwoo, Cho
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.6
    • /
    • pp.316-326
    • /
    • 2022
  • This study aimed to investigate the causes of the increasing Total Phosphate(TP) in the mainstream of Mangyeong river over the past 10 years, and suggested a reduction plan of about 3 points. First, the high TP concentration was continuously released in the discharge outlet of the Haepo bridge stormwater pipeline. The average TP concentration was 5.066 mg/L and values as high as 29.470 mg/L were measured. The highest pollution contribution rate to the Mangyeong river was more than 70 %. The cause of the pollution was expected to take place somewhere in Wanju Industrial Complex. Second, the average TP concentration of wastewater-treated effluent in the H factory was 0.405 mg/L. If a TP reduction facility is additionally installed in the H factory, it will help reduce TP uptake by Lake Saemangeum. Third, the TP concentration of untreated non-point source point flowing into the Samrae stream was very high with an average of 2.828 mg/L. Also, the pollution contribution rate of Samraecheon 2 to Mangyeong river was 21.8 % on average and up to 58 %. The pollution contribution rate was also high during the agricultural season and the winter, during which the flow rate is decreased. Investigation of these three points may be continuously needed, and analysis results and policy proposals presented to Jeollabukdo and Wanjugun to manage pollution sources.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

A Study on the Growth Process and Cases Type of Smart Farm - Focused on the Case of Korea and Japan - (스마트팜의 발전과정과 유형별 사례 조사 - 한국과 일본의 사례를 중심으로 -)

  • Nam, Yun-Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.37-46
    • /
    • 2024
  • The city is developing into a smart city. Smart villages and smart farms are developing in rural areas. Architectural technology needs synergy with smart cities, smart villages, and smart factories (intelligent factories) to help architectural experts understand smart farms and build facilities and equipment. Smart farms require design and construction technology with architectural structure and function. The purpose of this study was to investigate the current status and cases of smart farms in Korea and to investigate cases abroad. The conclusion is as follows. ① Smart farms are developing rapidly. The Korean government is expanding smart farms by utilizing ICT technology and infrastructure. ② 'Smart Farm Innovation Valley', which has been promoted since 2018, is a cutting-edge convergence cluster industrial complex that integrates production, education, and research functions such as start-ups and technological innovation. ③ In domestic cases, smart farms are operated in subway stations, buildings, supermarkets, and restaurants. ④ In the Japanese case, a dome-type smart farm was being operated. It utilized factory wastewater, waste heat, renewable energy, and used new materials. Otemachi Ranch raised livestock and provided a lounge on the 13th floor of the building. ⑤ In the cases of Korea and Japan, the smart farm technology is very similar. As stated earlier, since the food culture and agricultural technology of both countries are similar, we hope to promote the development of smart farms that can reduce concerns about future food by communicating and sharing mutual technologies.

The Performance of the Lanthanum-Zeolite Composite for the Eutrophication Prevention (부영양화 방지를 위한 란탄-제올라이트 복합체의 성능평가)

  • Kang, Min-Koo;Shin, Gwan-Woo;Park, Hyoung-Soon;Kim, Tae-Soo;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.3
    • /
    • pp.206-213
    • /
    • 2014
  • Nutrients such as phosphorus and nitrogen have been widely known as important source of algal appearance in eutrophic water. In order to prevent lake eutrophication, it is required to remove these nutrients not only presented in the lake water, but also released from the sediment. In order to solve this problem this study, the trivalent lanthanum ions and ammonia Nitrogen ($NH_4{^+}-N$) for the adsorption capacity of a zeolite support as it combines the lake water has dissolved in the nutrient removal, as well as deposits in the eluted in the continuously adsorbing the complex to develop and study was to inhibit the growth of algae. In experimental results, lanthanum complexes when the adsorption characteristics were evaluated $PO_4{^{3-}}-P$ and the $NH_4{^+}-N$ removal was confirmed that has an excellent ability, when it applied lake water the time of Chl-a and the turbidity decreased. In this study, these results suggest that the lanthanum complexes produced inhibitory effects on algae in the lake water is determined to excellent. Further, when applied to a complex of lanthanum in lake water to a standard 48 hours Acute Toxicity Method of toxicity were measured, and the results for the toxic effect was not observed.

Copper Accumulation in Cells of Copper-Tolerant Bacteria, Pseudomonas stutzeri (구리 내성균(Pseudomonas stutzeri)의 균체내 구리 축적특성)

  • Cho, Ju-Sik;Han, Mun-Gyu;Lee, Hong-Jae;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.1
    • /
    • pp.48-54
    • /
    • 1997
  • This study was performed to develop the biological treatment technology of wastewater polluted with heavy metals. The copper-tolerant bacteria, Pseudomonas stutzeri which possessed the ability to accumulate copper, was isolated from mine wastewaters polluted with various heavy metals. The characteristics of copper accumulation in the cells and the recovery of the copper from the cells accumulating zinc, were investigated. Removal rate of copper from the solution containing 100mg/l of copper by copper-tolerant bacteria was more than 78% at 2 days after inoculation with the cells. A large number of the electron-dense granules were found mainly on the cell wall and cell membrane fractions, when determined by transmission electron microscopy. Energy dispersive X-ray spectroscopy revealed that the electron-dense granules were copper complex with the substances binding copper. The copper accumulated into the cells was not desorbed by deistilled water, but more than 80% of the copper accumulated was desorbed by 0.1M-EDTA solution. The residues of the cells after combustion at $550^{\circ}C$ amounted to about 23.2% of the dry weight of the cells. EDS analysis showed that residues were relatively pure copper compound containing more than 78.4% of copper.

  • PDF

A Study on the Odor Characteristics and Identification of Microbial in Biological Swine Manure Treatment Process by Bioreactor (생물반응기를 도입한 돈분뇨의 생물학적 처리공정에서 악취발생 특성 및 미생물동정에 관한 연구)

  • Ko, Joon-il;Park, Gui-hwan;Bae, Ju-soon;Oh, Gil-young;Chung, Seon-yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.526-532
    • /
    • 2015
  • A bioreactor filling with pellets and stones was equipped to the swine manure treatment system, which is expected to emit high concentration of odor in the process of the organic wastewater treatment system, and in comparison with the activated sludge process as the control process, the reactor operation state, treatment water quality and odor emission concentration were measured. The reactor using the bioreactor proved to be much more stable in the bubble condition, treatment water transparency, etc, and BOD removal efficiency was also much better. The removal efficiency of T-N and T-P, however, showed little difference in the two reactors. Odor, as a result of examining $NH_3-N$, $NH_3$ concentratio, and complex odor, was 4 times to 24 times less emitted in the system using bioreactor than in the activated sludge system. $H_2S$, methyl mercaptan, dimethyl sulfide, and dimethyl disulfide were not found or were found in only 5 ppbs in each reactor and showed little difference between the two reactors. In the bioreactor process, Bacillus sp./ Pseudomonas sp. species were mainly found and in the activated sludge process, acterium sp. Chryseobacterium sp. species were mainly found.

Effects of Sewage Effluent on Organic Matters of Nakdong River: Comparison of Daily Loading (낙동강 수계 내 하수처리 방류수가 하류 하천 유기물에 미치는 영향: 부하량 비교)

  • Seong, Jin-Uk;Park, Je-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.210-217
    • /
    • 2012
  • This study investigated the water quality of effluents from the wastewater treatment plants, located at the Gumi Complex 4, Gumi, and Wonpyong, in Gumi. DOC accounted for higher than 70% of TOC, and oxidation efficiencies, calculated from carbon, were 13~43% for BOD and 37~73% for CODMn, respectively. Based on the biological decomposition experiments, R-DOC account for higher than 70% of DOC, mostly being occupied by refractory organic matters. This indicated that the biodegradable organics occupied more proportions of organic loadings than the refractory organics. The effect of the organics from a discharge of a sewage treatment plant on rivers, Gumi industrial Complex 4, Gumi, and Wonpyong on lower streams of the Nakdong River were found to be 15%, 6% and 16% respectively. The ratio of 15% suggests that comparatively, no large portions of TOC loadings are occupied, but the problem is that the biodegradable organic matters occupy a lot more proportions than that of the refractory organic matters. Thus, it is highly estimated that the refractory organics can gradually increase the pollution level of organics and precursors of disinfection by-products to the down-stream water treatment plants.

A Study on the Pollution of Bisphenol A in Surface Sediment around Gwangyang Bay (광양만 주변해역의 표층퇴적물 중 Bisphenol A의 오염에 관한 연구)

  • Cho Hyeon-Seo;Kim Yong-Ok;Shin Tai-Sun;Horiguchi Toshihiro
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.2
    • /
    • pp.104-110
    • /
    • 2004
  • This study was carried out to survey the pollution of bisphenol A(BPA) and total organic carbon(TOC) in surface sediments around Gwangyang bay. BPA is suspected chemicals as endocrine disruption. Gwangyang bay Is located on the mid south coast of Korea. It is a semi-closed bay which Yeosu petrochemical industrial complex, POSCO(Pohang Steel Company) and Gwangyang container harbor are located. The surface sediments were collected at 15 stations with gravity corer at October, 1999, February, May and August, 2000. Also, the stream and intertidal sediment were collected at 5 sites at August, 2000. Concentrations of BPA in surface sediments were in the range of 0.46 to 24.59 ng/g dry wt.. Seasonal range(mean value) of BPA are 0.59 to 9.00(1.88) ng/g dry wt. at October, 0.99 to 2.97(1.57) ng/g dry wt. at February, 0.46 to 24.59(2.53)ng/g dry wt. at May and 0.54 to 2.46 (1.29)ng/g dry wt. at August. BPA was seasonally fluctuated, and the highest mean value and range were detected at May, 2000. BPA was highly distributed in the inner part of Kwangyang bay than Yosu sound. Concentrations of BPA in stream and intertidal sediments showed the highest value in downstream near Yochon petrochemical industrial complex and Yondung stream. It suggests that the source of BPA are industrial wastewater and municipal sewage. TOC in surface sediments were in the range of 0.09∼1.22%. There was no any correlation between the BPA and TOC.

  • PDF

Sewer Decontamination Mechanism and Pipe Network Monitoring and Fault Diagnosis of Water Network System Based on System Analysis (시스템 해석에 기초한 하수관망 오염 매카니즘과 관망 모니터링 및 이상진단)

  • Kang, OnYu;Lee, SeungChul;Kim, MinJeong;Yu, SuMin;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.980-987
    • /
    • 2012
  • Nonpoint source pollution causes leaks and overtopping, depending on the state of the sewer network as well as aggravates the pollution load of the aqueous water system as it is introduced into the sewer by wash-off. According, the need for efficient sewer monitoring system which can manage the sewage flowrate, water quality, inflow/infiltration and overflow has increased for sewer maintenance and the prevention of environmental pollution. However, the sewer monitoring is not easy since the sewer network is built in underground with the complex nature of its structure and connections. Sewer decontamination mechanism as well as pipe network monitoring and fault diagnosis of water network system on system analysis proposed in this study. First, the pollution removal pattern and behavior of contaminants in the sewer pipe network is analyzed by using sewer process simulation program, stormwater & wastewater management model for expert (XP-SWMM). Second, the sewer network fault diagnosis was performed using the multivariate statistical monitoring to monitor water quality in the sewer and detect the sewer leakage and burst. Sewer decontamination mechanism analysis with static and dynamic state system results showed that loads of total nitrogen (TN) and total phosphorous (TP) during rainfall are greatly increased than non-rainfall, which will aggravate the pollution load of the water system. Accordingly, the sewer outflow in pipe network is analyzed due to the increased flow and inflow of pollutant concentration caused by rainfall. The proposed sewer network monitoring and fault diagnosis technique can be used effectively for the nonpoint source pollution management of the urban watershed as well as continuous monitoring system.

A Study on the Consciousness of the Environment Pollution Problem in Pohang City (환경문제에 관한 시민의식 조사 - 통합후 포항시민을 대상으로 -)

  • Ha, Yeong-Gil;Park, Kyung-Min;Kwon, Young-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.21 no.1
    • /
    • pp.61-73
    • /
    • 1996
  • This study conducted to determine the attitude on environment pollution by Pohang city citizens. 1,059 Pohang city citizens in the age group 20 and over were chosen and surveyed by officials's interview at Up, Myun and Dong during the period 6 September to 20 September 1995. The issue problems to be solved in Pohang city were traffic control 47.3%, environment pollution 22.7%, cultural institutions 11.6%, water service 9.9%, education system 5.1% and community security 2.1%. The 55.1% of subjects responded that responsibility for environment pollution is every citizens duty. The trash from houses were 'garbage'(48.1%), 'waste of life'(21.8%), 'reuse trash'(15.6%) and 'one use thing'(14.5%) in order. The 66.9% of subjects responded that the trash's standard envelopes can be easily tear and its texture is not good. The respondents sometimes or often had experienced foreign bodies, sediment in the water service supply. The 45.9% of the respondents use natural water as drinking water, and the water service supply(26.7%), underground water(17.0%) and buying water(9.3%) were followed. Pertaining to the air pollution(by percent) was pollution of the steel industry complex 78.0%, combustive gas 16.6% and construction dust 1.7%. The respondents at southern district complained of respiratory tract by air pollution and the respondents at northern district complained of the visual disturbance and the offensive odor(P<0.05). Water pollution problem is factory's wastewater 56.2%, home wastewater 36.4% and livestock's wastewater 5.6% in order. The respondents at southern district complained of the noise pollution by airplanes and factories at the afternoon and the respondents at northern district complained of the noise pollution by vehicles(P<0.05).

  • PDF