• Title/Summary/Keyword: complex separation

Search Result 451, Processing Time 0.028 seconds

A Study on Semi Quantitative Risk Analysis for Air Separation Unit using a GRA(Generic Risk Analysis) Method (GRA(Generic Risk Analysis) 기법을 이용한 공기분리시설에 대한 준 정량적 위험성 평가에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.1
    • /
    • pp.56-66
    • /
    • 2013
  • The gas production plants supply the inert gas to production plants for maintaining safe operation and also supply combustible, flammable, explosive and toxic gases as functions of basic materials needed for producing chemical goods. In addition, gas plants need to be safe and reliable operation because they are operated under high temperature, high pressure, cryogenic and catalytic reactions. As these plants have a complex process in operation, there has been a risk that major industrial accidents such as a fire, explosion and toxic gas released, also risks of asphyxiations by inert gases and burns caused by high temperature and cryogenic substances. This study is to carry out the semi quantitative risk assesment method which is the generic risk analysis (GRA). This method is applied to air separation unit(ASU) to identify its initial risk, safety barriers, residual risk and elements important for safety(EIS). The result of this study, suggested the management tools and procedures of implementation for EIS management.

Rapid, Sensitive, and Specific Detection of Salmonella Enteritidis in Contaminated Dairy Foods using Quantum Dot Biolabeling Coupled with Immunomagnetic Separation

  • Kim, Hong-Seok;Chon, Jung-Whan;Kim, Hyunsook;Kim, Dong-Hyeon;Yim, Jin-Hyuk;Song, Kwang-Young;Kang, Il-Byung;Kim, Young-Ji;Lee, Soo-Kyung;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.4
    • /
    • pp.271-275
    • /
    • 2015
  • Colloidal semiconductor CdSe-ZnS core-shell nanocrystal quantum dot (Qdot) are luminescent inorganic fluorophores that show potential to overcome some of the functional limitations encountered with organic dyes in fluorescence labeling applications. Salmonella Enteritidis has emerged as a major cause of human salmonellosis worldwide since the 1980s. A rapid, specific, and sensitive method for the detection of Salmonella Enteritidis was developed using Qdot as a fluorescence marker coupled with immunomagnetic separation. Magnetic beads coated with anti-Salmonella Enteritidis antibodies were employed to selectively capture the target bacteria, and biotin-conjugated anti-Salmonella antibodies were added to form sandwich immune complexes. After magnetic separation, the immune complexes were labeled with Qdot via biotin-streptavidin conjugation, and fluorescence measurement was carried out using a fluorescence measurement system. The detection limit of the Qdot method was a Salmonella Enteritidis concentration of $10^3$ colony-forming units (CFU)/mL, whereas the conventional fluorescein isothiocyanate-based method required over $10^5CFU/mL$. The total detection time was within 2 h. In addition to the potential for general nanotechnology development, these results suggest a new rapid detection method of various pathogenic bacteria from a complex food matrix.

  • PDF

Separation of Optical Isomers of DNS-Amino Acids in High-Performance Liquid Chromatography (고성능 액체크로마토 그래피에 의한 Dansyl-아미노산 광학이성질체의 분리)

  • Sun Haing Lee;Tae Sub O;Kyung Sug Park
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.2
    • /
    • pp.216-223
    • /
    • 1986
  • Separation of optical isomers of DNS derivatized amino acids by a reversed-phase high-performance liquid chromatography has been studied by adding a complex of an optically active amino acid (L-arginine) with the metal ion (Cu(II), Zn(II), Cd(II), Ni(II)) to the mobile phase. The separations are affected by the concentrations of acetonitrile, chelate and buffer. They are also affected by the pH and the kinds of metal and buffer. A separation mechanism, which is based on steric effect of the ligand exchange reaction for the formation of ternary complexes by the D,L-DNS-amino acids and the chiral additive associated with the stationary phase, is proposed to interpret the elution behaviors of D, L-dansyl-amino acids.

  • PDF

Selective Separation and Determination of Iron with Ion-Exchange Resins (이온교환수지에 의한 철의 선택적 분리 및 정량)

  • Yong Soon Chung;Dong Won Kim;Seung Ho Kim;Dai Woon Lee
    • Journal of the Korean Chemical Society
    • /
    • v.31 no.1
    • /
    • pp.45-54
    • /
    • 1987
  • Dowex 1-X8 resin ion exchanged with calcon carboxylic acid (CCA-Dowex 1-X8) and 2-methyl-8-hydroxyquinoline(MHQ) impregnated-Amberlite XAD-4 resin (MHQ-XAD-4) were examined for the separation and preconcentration of ferric ion from the various matrices. The stabilities of these resins were investigated, and their capacities on ferric ion were also measured. The effect of pH on the adsorption of ferric ion and matrix ions, such as Al(Ⅲ) and Ca(Ⅱ), was investigated to determine the optimun pH ranges. Separation and preconcentration of iron in aluminium foil and mineral water samples were studied by elution method with these resin columns. The recovered ions by 10ml of 2F nitric acid was determined by flame atomic spectrophotometry. SP-Sephadex C-25 column was used to separate ferrous and ferric ion in mineral water by stepwise elution with ferrozine and 1 % ascorbic acid-ferrozine solution. The concentrated and separated each ion could be determined spectrophotometrically at the analytical wavelenth of Fe(Ⅱ)-ferrozine complex (562nm).

  • PDF

Speciation of Chromium in Water Samples with Homogeneous Liquid-Liquid Extraction and Determination by Flame Atomic Absorption Spectrometry

  • Abkenar, Shiva Dehghan;Hosseini, Morteza;Dahaghin, Zohreh;Salavati-Niasari, Masoud;Jamali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2813-2818
    • /
    • 2010
  • A novel method was developed for the speciation of chromium in natural water samples based on homogeneous liquid-liquid extraction and determination by flame atomic absorption spectrometry (FAAS). In this method, Cr(III) reacts with a new Schiff's base ligand to form the hydrophobic complex, which is subsequently entrapped in the sediment phase, whereas Cr(VI) remained in aqueous phase. The Cr(VI) assay is based on its reduction to Cr(III) by the addition of sodium sulfite to the sample solution. Thus, separation of Cr(III) and Cr(VI) could be realized. Homogeneous liquid-liquid extraction based on the pH-independent phase-separation process was investigated using a ternary solvent system (water-tetrabutylammonium ion ($TBA^+$)-chloroform) for the preconcentration of chromium. The phase separation phenomenon occurred by an ion-pair formation of TBA and perchlorate ion. Then sedimented phase was separated using a $100\;{\mu}L$ micro-syringe and diluted to 1.0 mL with ethanol. The sample was introduced into the flame by conventional aspiration. After the optimization of complexation and extraction conditions such as pH = 9.5, [ligand] = $1.0{\times}10^{-4}\;M$, [$TBA^+$] = $2.0{\times}10^{-2}\;M$, [$CHCl_3$] = $100.0\;{\mu}L$ and [$ClO_4$] = $2.0{\times}10{-2}\;M$, a preconcentration factor (Va/Vs) of 100 was obtained for only 10 mL of the sample. The relative standard deviation was 2.8% (n = 10). The limit of detection was sufficiently low and lie at ppb level. The proposed method was applied for the extraction and determination of chromium in natural water samples with satisfactory results.

Isoprene/n-pentane separation using facilitated transport membranes with SPEEK-AgNO3 (SPEEK-AgNO3로 이루어진 촉진 수송 분리 막을 사용한 isoprene/n-pentane 혼합물 분리)

  • Choi, Hyun Woo;Kim, Dong Bum;Kim, Hoon Sik;Lee, Chang Ha;Choi, Dae Ki
    • Clean Technology
    • /
    • v.10 no.3
    • /
    • pp.169-176
    • /
    • 2004
  • Sulfonated ionomer membranes, sulfonated poly(ether ether)ketone (SPEEK)-$AgNO_3$, were prepared and tested for separation of the isoprene/n-pentane mixtures. The facilitated transport membranes showed good selectivity and permeance of isoprene over n-pentane and long-term stability. Depending on various reaction conditions, the degree of sulfonation (DS) of SPEEK was measured by 1H NMR spectroscopy and the performance of the membranes was affected by the DS of SPEEK as a whole. As the DS of SPEEK was increased, the selectivity of isoprene over n-pentane increased and eventually reached a maximum selectivity of 850 ~ 900 and the stability of that was continued more than 100 h.

  • PDF

Hydrogen Perm-Selectivity Property of the Palladium Hydrogen Separation Membranes on Porous Stainless Steel Support Manufactured by Metal Injection Molding (금속 사출성형 방식의 다공성 스테인리스 강 지지체에 형성된 팔라듐 수소 분리막의 투과 선택도 특성)

  • Kim, Se-Hong;Yang, Ji-Hye;Lim, Da-Sol;Kim, Dong-Won
    • Journal of Surface Science and Engineering
    • /
    • v.50 no.2
    • /
    • pp.98-107
    • /
    • 2017
  • Pd-based membranes have been widely used in hydrogen purification and separation due to their high hydrogen diffusivity and infinite selectivity. However, it has been difficult to fabricate thin and dense Pd-based membranes on a porous stainless steel(PSS) support. In case of a conventional PSS support having the large size of surface pores, it was required to use complex surface treatment and thick Pd coating more than $6{\mu}m$ on the PSS was required in order to form pore free surface. In this study, we could fabricate thin and dense Pd membrane with only $3{\mu}m$ Pd layer on a new PSS support manufactured by metal injection molding(MIM). The PSS support had low surface roughness and mean pore size of $5{\mu}m$. Pd membrane were prepared by advanced Pd sputter deposition on the modified PSS support using fine polishing and YSZ vacuum filling surface treatment. At temperature $400^{\circ}C$ and transmembrane pressure difference of 1 bar, hydrogen flux and selectivity of $H_2/N_2$ were $11.22ml\;cm^{-2}min^{-1}$ and infinity, respectively. Comparing with $6{\mu}m$ Pd membrane, $3{\mu}m$ Pd membrane showed 2.5 times higher hydrogen flux which could be due to the decreased Pd layer thickness from $6{\mu}m$ to $3{\mu}m$ and an increased porosity. It was also found that pressure exponent was changed from 0.5 on $6{\mu}m$ Pd membrane to 0.8 on $3{\mu}m$ Pd membrane.

Study on Pressurized Diesel Reforming System for Polymer Electrolyte Membrane Fuel Cell in Underwater Environment (수중 환경에서 고분자 전해질 연료전지(PEMFC) 공급용 수소 생산을 위한 가압 디젤 개질시스템에 관한 연구)

  • Lee, Kwangho;Han, Gwangwoo;Bae, Joongmyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.528-535
    • /
    • 2017
  • Fuel cells have been spotlighted in the world for being highly efficient and environmentally friendly. A hydrogen which is the fuel of fuel cell can be obtained from a number of sources. Hydrogen source for operating the polymer electrolyte membrane fuel cell(PEMFC) in the current underwater environment, such as a submarine and unmanned underwater vehicles are currently from the metal hydride cylinder. However, metal hydride has many limitations for using hydrogen carrier, such as large volume, long charging time, limited storage capacity. To solve these problems, we suggest diesel reformer for hydrogen supply source. Diesel fuel has many advantages, such as high hydrogen storage density, easy to transport and also well-infra structure. However, conventional diesel reforming system for PEMFC requires a large volume and complex CO removal system for lowering the CO level to less than 10 ppm. In addition, because the preferential oxidation(PROX) reaction is the strong exothermic reaction, cooling load is required. By changing this PROX reactor to hydrogen separation membrane, the problem from PROX reactor can be solved. This is because hydrogen separation membranes are small and permeable to pure hydrogen. In this study, we conducted the pressurized diesel reforming and water-gas shift reaction experiment for the hydrogen separation membrane application. Then, the hydrogen permeation experiments were performed using a Pd alloy membrane for the reformate gas.

A Study on Ground and Object Separation Techniques Utilizing 3D Point Cloud Data in Urban Air Mobility (UAM) Environments (UAM 환경에서의 3D Point Cloud Data 지면/객체 분리 기법 연구)

  • Bon-soo Koo;In-ho choi;Jae-rim Yu
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.481-487
    • /
    • 2023
  • Recently, interest in UAM (Urban Air Mobility) has surged as a critical solution to urban traffic congestion and air pollution issues. However, efficient UAM operation requires accurate 3D Point Cloud data processing, particularly in separating the ground and objects. This paper proposes and validates a method for effectively separating ground and objects in a UAM environment, taking into account its dynamic and complex characteristics. Our approach combines attitude information from MEMS sensors with ground plane estimation using RANSAC, allowing for ground/object separation that isless affected by GPS errors. Simulation results demonstrate that this method effectively operates in UAM settings, marking a significant step toward enhancing safety and efficiency in urban air mobility. Future research will focus on improving the accuracy of this algorithm, evaluating its performance in various UAM scenarios, and proceeding with actual drone tests.

Characters of Mesoscale Convective Complex Development in Korean Peninsula (한반도 중규모 대류복합체의 발달특성에 관한 연구)

  • Lee Soon-Hwan;Won Hyo-Sung
    • Journal of the Korean earth science society
    • /
    • v.26 no.7
    • /
    • pp.698-705
    • /
    • 2005
  • Heavy rain fall in the Korean Peninsula often occurs in the summer season due to MCC (Mesoscale Convective Complex) with complex mechanism. We analysed the Characteristics and the developing mechanism of MCC occurred at 14 July 2004. The results are as follows: a) There is strong wind inflow from the South-west china sea with heavy moisture and this moisture flux acts as the source of heavy rain, b) Because of the separation of upper and lower atmosphere due to an inversion layer at 600hPa, atmosphere over the Korea Peninsula is suddenly unstable. c) This MCC shows strong shear not with wind direction, but with the wind speed, and this wind shear continues the thermodynamic unstability of the convective system. d) MCC was suddenly developed over Heuksando at 1400LST 14 July 2004. Thus we can say that the topography also was strongly associated with the development of MCC and it is also necessary to clarify the relationship between topography and MCC development. in future research.