• Title/Summary/Keyword: complex analytical method

Search Result 431, Processing Time 0.028 seconds

A Simplified Analytical Method for the Capacity and Level of Service of Signalized Intersections (신호교차로 용량 및 서비스수준에 대한 간략적 분석방법(4갈래 교차로 비포화 상태를 대상으로))

  • Hong, Soon-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.4 s.75
    • /
    • pp.43-56
    • /
    • 2004
  • The KHCM procedure is a micro level analysis at signalized intersections requiring a lot of input variables and complex computations. The research was to investigate the possibility of simplifying the analysis procedures by using the generalized or the combined variables that less influence on the adjusted traffic volume and through-car equivalents of left or right turns. It was also tried to make lane grouping into directional flow ratio(v/s) based on a field surveys. The maximum and minimum values of each variables were compared with each other through the KHCM analysis procedures in terms of control delay. The lane grouping and the synthetical influence of a simplified method was evaluated with the scenario built in prevailing maximum and minimum conditions. The study showed that the control delay was not significantly sensitive to the selected variables and the lane grouping and their synthetical influence as well.

Interaction Analysis on Deployment of Multiple Wave Energy Converters in a Floating Hybrid Power Generation Platform (부유식 복합발전 플랫폼내의 다수 파력발전기 배치를 위한 상호작용 해석)

  • Lee, Hyebin;Cho, Il Hyoung;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 2016
  • In this study, the present deployment of the multiple wave energy converters (WECs) in a floating wind-wave hybrid power generation platform was estimated considering the interaction effect among WEC buoys. The interaction processes of multiple buoys were very complex, since scattered and radiated waves from each buoy affected the others in the array. The interaction analysis of the diffraction and radiation problem by the array of WECs was applied by matched eigenfunction expansion method (MEEM). The analytical solutions were compared with the results of numerical calculation based on WAMIT. The overall performance of 24 WECs installed in the hybrid power generation platform was evaluated by the q-factor representing the interaction effect among buoys.

In vitro and in vivo studies on theophylline mucoadhesive drug delivery system

  • Bandyopadhyay, AK;Perumal, P
    • Advances in Traditional Medicine
    • /
    • v.7 no.1
    • /
    • pp.51-64
    • /
    • 2007
  • Mucus is an aqueous gel complex with a constitution of about 95% water, high molecular weight glycoprotein (mucin), lipid, salts etc. Mucus appears to represent a significant barrier to the absorption of some compounds. Natural mucoadhesive agent was isolated and purified from the aqueous extract of the seeds of prosopis pallida (PP). Formulated tablet with the isolated material by wet granulation method. Some natural edible substances are in consideration for candidates as mucoadhesive agents to claim more effective controlled drug delivery as an alternative to the currently used synthetic mucoadhesive polymers. Subjected the materials obtained from natural source i.e. PP and standard synthetic substance, sodium carboxymethyl cellulose for evaluation of mucoadhesive property by various in vitro and in vivo methods. Through standard dissolution test and a model developed with rabbit, evaluated in vitro controlled release and bioadhesive property of theophylline formulation. Mucoadhesive agent obtained from PP showed good mucoadhesive potential in the demonstrated in vitro and in viνo models. The results suggest that the mucoadhesive agent showed controlled release properties by their application, substantially. In order to assess the gastrointestinal transit time in vivo, a radio opaque X-ray study performed in healthy rabbit testing the same controlled release formulation with and without bioadhesive polymer. Plasma levels of theophylline determined by the HPLC method and those allowed correlations to the in vitro mucoadhesive study results. Better correlation found between the results in different models. PP may acts as a better natural mucoadhesive agent in the extended drug delivery system.

Simulation of Elastic Wave Propagation in Anisotropic Materials (이방성 재료에서의 탄성파 전파 과정에 대한 시뮬레이션)

  • Kim, Young-H.;Lee, Seung-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.4
    • /
    • pp.227-236
    • /
    • 1997
  • Quantitative analysis and imaging of elastic wave propagation are very important for the materials evaluation as well as flaw detection. The elastic wave propagation in an anisotropic media is more complex, and analysis and imaging become essential for flaw detection and materials evaluation. In the anisotropic media, the wave velocity is dependent on the propagation direction. In addition, the direction of group velocity is different from that of phase velocity, the direction of energy flow is not same as the propagation direction of wavefront (beam skewing effect). Especially, this effect becomes critical for the large anisotropic media such as fiber composite materials, and the results using elastic waves for those materials have to be analyzed considering the wave propagation mechanism. Since the analytical approach for the wave propagation in the anisotropic materials is limited, the numerical analysis such as finite difference method (FDM) have been used for these case. Therefore, 2-dimensional FDM program for the elastic wave propagation is developed, and wave propagation in anisotropic media are simulated.

  • PDF

Determination of N,N-Dimethylformamide in Ambient Air Using Adsorption Sampling and Thermal Desorption with GC/MS Analysis (흡착-열탈착-GC/MS를 이용한 환경대기 중 N,N-Dimethylformamide 농도 측정)

  • Seo, Young-Kyo;Hwang, Yoon-Jung;Lee, Soon-Jin;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.357-366
    • /
    • 2010
  • The purpose of this study is to evaluate a method for the measurement of N,N-Dimethylformamide (DMF) and to apply the method to the ambient air samples. For the determination of DMF together with other general VOCs (e.g., benzene, toluene, and xylenes), adsorption sampling and thermal desorption with GC/MS was used in this study. The sampling and analytical approaches tested in this study showed a good repeatability and linearity with lower detection limits of less than 0.35 ppb. Field measurements were carried out at three industrial sites (Daegu-Seongseo, Siwha and Banwall industrial complexes) and one residential site in Daegu city during a period from October 2006 to November 2008. DMF was detected in 71.8% of the total samples from the Seongseo industrial complex, well known for textile industry. In contrast, DMF was detected in only 20.4% and 12.9% of all the samples from the other two sites in Banwall and Siwha industrial complexes, respectively. This implies that sources of DMF should be strongly associated with textile industry. The mean concentration of DMF also appeared to be the highest in Seongseo site (5.95 ppb), followed by a residential site in Daegu (3.28 ppb), Banwall (0.88 ppb) and Siwha (0.55 ppb). In this study, we demonstrated the environmental significance of DMF in urban ambient air. To our knowledge, the DMF measurement introduced in this paper is the first case of an official report in Korea.

A Study on Synthetic Method and Material Analysis of Calcium Ammine Chloride as Ammonia Transport Materials for Solid SCR (Solid SCR용 암모니아 저장물질인 Calcium Ammine Chloride의 합성방법 및 물질분석 연구)

  • Shin, Jong Kook;Yoon, Cheon Seog;Kim, Hongsuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.199-207
    • /
    • 2015
  • Solid materials of ammonia sources with SCR have been considered for the application of lean NOx reduction in automobile industry, to overcome complex problems of liquid urea based SCR. These solid materials produce ammonia gas directly with proper heating and can be packaged by compact size, because of high volumetric ammonia density. Among ammonium salts and metal ammine chlorides, calcium ammine chloride was focused on this paper due to low decomposition temperature. In order to make calcium ammine chloride in lab-scale, simple reactor and glove box was designed and built with ammonium gas tank, regulator, and sensors. Basic test conditions of charging ammonia gas to anhydrous calcium chloride are chosen from equilibrium vapor pressure by Van't Hoff plot based on thermodynamic properties of materials. Synthetic method of calcium ammine chloride were studied for different durations, temperatures, and pressures with proper ammonia gas charged, as a respect of ammonia gas adsorption rate(%) from simple weight calculations which were confirmed by IC. Also, lab-made calcium ammine chloride were analyzed by TGA and DSC to clarify decomposition step in the equations of chemical reaction. To understand material characteristics for lab-made calcium ammine chloride, DA, XRD and FT-IR analysis were performed with published data of literature. From analytical results, water content in lab-made calcium ammine chloride can be discovered and new test procedures of water removal were proposed.

Analytic adherend deformation correction in the new ISO 11003-2 standard: Should it really be applied?

  • Ochsner, A.;Gegner, J.;Gracio, J.
    • Journal of Adhesion and Interface
    • /
    • v.5 no.2
    • /
    • pp.14-26
    • /
    • 2004
  • For reliable determination of mechanical characteristics of adhesively bonded joints used e.g. as input data for computer-aided design of complex components, the thick-adherend tensile-shear test according to ISO 11003-2 is the most important material testing method. Although the total displacement of the joint is measured across the polymer layer directly in the overlap zone in order to minimize the influence of the stepped adherends, the substrate deformation must be taken into account within the framework of the evaluation of the shear modulus and the maximum shear strain, at least when high-strength adhesives are applied. In the standard ISO 11003-2 version of 1993, it was prescribed to perform the substrate deformation correction by means of testing a one-piece reference specimen. The authors, however, pointed to the excessive demands on the measuring accuracy of the extensometers connected with this technique in industrial practice and alternatively proposed a numerical deformation analysis of a dummy specimen. This idea of a mathematical correction was included in the revised ISO 11003-2 version of 2001 but in the simplified form of an analytical method based on Hooke's law of elasticity for small strains. In the present work, it is shown that both calculation techniques yield considerably discordant results. As experimental assessment would require high-precision distance determination (e.g. laser extensometer), finite element analyses of the deformation behavior of the bonded joint are performed in order to estimate the accuracy of the obtained substrate deformation corrections. These simulations reveal that the numerical correction technique based on the finite element deformation modeling of the reference specimen leads to considerably more realistic results.

  • PDF

Verification with of High Efficiency Chemical Binding System of a Physiologically Active Radioisotope Using ESI-TOF/Ms System (고효율의 ESI-TOF/Ms 시스템을 이용한 생리활성 항체와 방사성동위원소 표지용 착화제의 결합 검증)

  • Joh, Eun-Ha;Hong, Young Don;Choi, Sun Ju
    • YAKHAK HOEJI
    • /
    • v.57 no.6
    • /
    • pp.400-405
    • /
    • 2013
  • In this study, we measured the complex efficiency of a physiologically active antibody, a chelator and radiosiotopes using the ESI-TOF/Ms system for develop good radiopharmaceuticals. For a precise measurement, TLC is a low accuracy method. Loading of same amount of sample is difficult for each test, and work to quantify accurately the results obtained through TLC cannot be afforded compared to the use of other analytical instruments. The method of analysis using a mass spectrometer is capable of a mass analysis of proteins for quantitative analysis. The conjugates of the chelator (CHX-A- DTPA) and the antibody (IgG) were separated through MWCO, and were analyzed using ESI-TOF and MALDI-TOF mass spectrometry. The analysis using MALDI-TOF is roughly divided into measurements on mass spectrometry. When conjugating a small molecular weight of CHX-A-DTPA and a large molecular weight of IgG, distinguishing the peak of the conjugate and the peak of IgG was difficult. However, an ESI-TOF mass spectrometer system is capable of an analysis of mass by decentralizing the IgG. It is utilized as a technique for measuring the metabolic processes during conjugation and the stability evaluation of radiopharmaceuticals. When establishing this technique, the accuracy of the overall radiophar-maceutical analysis is expected to be able to be improved.

Analytical Methods for the Extraction of PV panel Single-Diode model parameters from I-V Characteristic (I-V 특성곡선을 통한 태양전지 패널의 모델 파라미터 추출 방법)

  • Choi, Sung-Won;Ryu, Ji-Hyung;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.847-851
    • /
    • 2011
  • Photovoltaic System is increasing install capacity based on environmental-friendly characteristics. It have been actively studied to improve the efficiency. In order to design highly efficient system, it is important to understand the output characteristics of solar panels. The single diode model can represent the physical characteristics of solar panel. But it needs complex process such as mutli-step measurement and numerical analysis to get the exact parameters. In this paper, The method for extracting characteristic parameters of the single diode model based on the I-V characteristic curves in the panel manufacturer's data-sheet is presented. To verify the proposed method, solar cell model constructed in simulink. Simulink model output compared with output graph in datasheet.

Development of Thermal-Hydraulic-Mechanical Coupled Numerical Analysis Code for Complex Behavior in Jointed Rock Mass Based on Fracture Mechanics (균열 암반의 복합거동해석을 위한 열-수리-역학적으로 연계된 파괴역학 수치해석코드 개발)

  • Kim, Hyung-Mok;Park, Eui-Seob;Shen, Baotang;Synn, Joong-Ho;Kim, Taek-Kon;Lee, Seong-Cheol;Ko, Tae-Young;Lee, Hee-Suk;Lee, Jin-Moo
    • Tunnel and Underground Space
    • /
    • v.21 no.1
    • /
    • pp.66-81
    • /
    • 2011
  • In this study, it was aimed to develop a thermal-hydraulic-mechanical coupled fracture mechanics code that models a fracture initiation, propagation and failure of underground rock mass due to thermal and hydraulic loadings. The development was based on a 2D FRACOD (Shen & Stephasson, 1993), and newly developed T-M and H-M coupled analysis modules were implemented into it. T-M coupling in FRACOD employed a fictitious heat source and time-marching method, and explicit iteration method was used in H-M coupling. The validity of developed coupled modules was verified by the comparison with the analytical result, and its applicability to the fracture initiation and propagation behavior due to temperature changes and hydraulic fracturing was confirmed by test simulations.