• Title/Summary/Keyword: complex analytical method

Search Result 431, Processing Time 0.025 seconds

Identification of Dynamic Properties of Globe Valve by Test (시험에 의한 글로브밸브의 동특성 비교 분석)

  • 박형기
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.308-314
    • /
    • 1999
  • This paper presents the results of structural identification of a safety-related valve for nuclear power plant by impact hammer test as well as shaking table tests by using broadband random wave and sine sweep excitation. The test specimen is a Y-type motor operated globe valve. The test was performed as a "support test" to validate the analytically obtained modal parameters of the valve during its seismic qualification process by analytical method. From the study results it has been found that the shaking table test generally yields higher natural frequencies and lower damping values compared with those of impact hammer test. And it has been recognized that impact hammer test for modal identification of complex structures should be applied very carefully to get reasonable results.e results.

  • PDF

Analysis of Hysteretic Behavior of R/C Members subjected to Load Reversals - Single component model having the finite size of plastic regions - (반복하중을 받는 철근콘크리트 부재의 이력거동 해석 -유한한 소성력을 갖는 일원성분 모델을 사용하여-)

  • 김윤일;이리형;서수연;천영수
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.04a
    • /
    • pp.6-11
    • /
    • 1990
  • Inelastic behavior of reinforced concrete members is very complex and affected by many factors. Therefore, though using the finite element method which is good to predict the response of R/C member, it has to be proceeded to model these factors appropriately which have influence on the behavioral characteristics of reinforced concrete members. The proposed model consists of the physical single component model having the finite size of plastic regions and the hysteretic rules, by regressing experimental data, which can idealize the hysteretic behavior of R/C member under inelastic cyclic loads. This study confirms the accuracy of the developed analytical model through comparison with the test results of R/C members having a variety of shear-to-depth ratio and maximum shear stress.

  • PDF

Modified Unipolar Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Voltage Source Inverters

  • Srirattanawichaikul, Watcharin;Premrudeepreechacharn, Suttichai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.489-500
    • /
    • 2014
  • This paper presents a simple modified unipolar carrier-based pulsewidth modulation (CB-PWM) strategy for the three-level neutral-point-clamped (NPC) voltage source inverter (VSI). Analytical expressions for the relationship between modulation reference signals and output voltages are derived. The proposed modulation technique for the three-level NPC VSI includes the maximum and minimum of the three-phase sinusoidal reference voltages with zero-sequence voltage injection concept. The proposed modified CB-PWM strategy incorporates a novel method that requires only of one triangular carrier wave for generate the gating pulses in three-level NPC VSI. It has the advantages of being simplifying the algorithm with no need of complex two/multi-carrier pulsewidth modulation or space vector modulation (SVM) and it's also simple to implement. The possibility of the proposed CB-PWM technique has been verified though computer simulation and experimental results.

Analysis of FE/test result for con011ing the squeal noise of wheel brake system (휠제동장치의 스퀼소음 제어를 위한 해석결과 분석)

  • Cha, Jung-Kwon;Park, Yeong-Il;Lee, Dong-Kyun;Cho, Dong-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.595-600
    • /
    • 2009
  • Passengers in a vehicle feel uncomfortable due to squeal noise. Squeal noise, a kind of self-excited vibration, is generated by the friction force between the disc and the pad of the automobile. In this paper, modal analysis of wheel brake system was performed in order to prediction of squeal phenomenon. It was shown that the prediction of system instability is possible by FEM. Finite element model of that brake system was made. Some parts of a real brake was selected and modeled. The normal mode analysis method performs analyses of each brake system component. Experiment of modal analysis was performed for each brake components and experimental results were compared with analytical result from FEM. The complex eigenvalue analysis results compared with braking test. The analysis results show good correlation with braking test for the squeal frequency at an unstable mode.

  • PDF

High-resolution 1H NMR Spectroscopy of Green and Black Teas

  • Jeong, Ji-Ho;Jang, Hyun-Jun;Kim, Yongae
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.2
    • /
    • pp.78-84
    • /
    • 2019
  • High-resolution $^1H$ NMR spectroscopic technique has been widely used as one of the most powerful analytical tools in food chemistry as well as to define molecular structure. The $^1H$ NMR spectra-based metabolomics has focused on classification and chemometric analysis of complex mixtures. The principal component analysis (PCA), an unsupervised clustering method and used to reduce the dimensionality of multivariate data, facilitates direct peak quantitation and pattern recognition. Using a combination of these techniques, the various green teas and black teas brewed were investigated via metabolite profiling. These teas were characterized based on the leaf size and country of cultivation, respectively.

Determination of Vitamin B12 and Biotin in Foods for Special Dietary Uses with Immunoaffinity Column (면역친화성 컬럼을 이용한 특수용도식품 중 비타민B12와 비오틴 분석 연구)

  • Oh, Bo-Young;Ye, Min-Ji;Hu, Soo-Jung;Lee, Hye-Young;Bang, Soo-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.252-260
    • /
    • 2020
  • This study was conducted to improve the standard method for vitamin B12 and biotin contained in foods for special dietary uses to ensure the specificity of the complex matrix properties of foods. For the food code, the test method was improved to determine vitamin B12 and biotin by high-performance liquid chromatography (HPLC)-UV using column-switching after concentration using immunoaffinity column. The immunoaffinity columns contain a gel suspension of monoclonal antibody specific to the vitamin of interest so that it can be used to concentrate the vitamin B12 and biotin and remove interferences from the food extracts. Moreover, validation of advanced new methods was carried out to support the suitability of the proposed analytical procedure (specificity, linearity, detection limits (LOD), quantitative limits (LOQ), accuracy, and precision). The improved analytical method is being used to monitor relevant food items on sale. The results of this study showed that the new analytical method is suitable and appropriate for managing food intended for special dietary uses.

Analysis on Food Waste Compost by Near Infrared Reflectance Spectroscopy(NIRS) (Near Infrared Reflectance Spectroscopy(NIRS)에 의한 음식물 쓰레기 퇴비 분석에 관한 연구)

  • Lee Hyo-Won;Kil Dong-Yong
    • Korean Journal of Organic Agriculture
    • /
    • v.13 no.3
    • /
    • pp.281-289
    • /
    • 2005
  • In order to find out an alternative way of analysis of food waste compost, the Near Infrared Reflectance Spectroscopy(NIRS) was used for the compost assessment because the technics has been known as non-detructive, cost-effective and rapid method. One hundred thirty six compost samples were collected from Incheon food waste compost factory at Namdong Indurial Complex. The samples were analyzed for nitrogen, organic matter (OM), ash, P, and K using Kjedahl, ignition method, and acid extraction with spectrophotometer, respectively. The samples were scanned using FOSS NIRSystem of Model 6500 scanning mono-chromator with wavelength from $400\~2,400nm$ at 2nm interval. Modified partial Least Squares(MPLS) was applied to develop the most reliable calibration model between NIR spectra and sample components such as nitrogen, ash, OM, P, and K. The regression was validated using validation set(n=30). Multiple correlation coefficient($R^2$) and standard error of prediction(SEP) for nitrogen, ash, organic matter, OM/N ratio, P and K were 0.87, 0.06, 0.72, 1.07, 0.68, 1.05, 0.89, 0.31, 0.77, 0.06, and 0.64, 0.07, respectively. The results of this experiment indicates that NIRS is reliable analytical method to assess some components of feed waste compost, also suggests that feasibility of NIRS can be Justified in case of various sample collection around the year.

  • PDF

Spectrophotometric Determination of Chlorpheniramine Maleate with Methyl Orange (메칠오렌지에 의한 말레인산클로르페니라민의 분광광도 정량)

  • Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.4
    • /
    • pp.139-147
    • /
    • 1986
  • A singly charged methyl orange(MO) anion was found to be extracted with chlorpheniramine maleate(CPM) as a 1 : 1 complex in chloroform. Of various solvents, MO-chloroform system gave a yellow color for CPM, while in the absence of CPM, an organic phase showed almost no color. In this way, the spectrophotometric method was investigated for the determination of CPM by solvent extraction. The addition of alcoholic bolic acid solution to the solvent extract gave a higher color stability and transparency at least 5 days, but the extract alone lost its color intensity significantly. CPM is determined by measuring the absorbance of the extracts over a range of $1{\sim}7{\times}10^{-4}M\;(39{\sim}273\;{\mu}g/ml)$ in aqueous solution at 423 nm. The molar absorptivity was $2.26{\times}10^3\;l,\;mol^{-1},\;cm^{-1}$. The absorbance of the extract was constant in the range of pH $3.7{\sim}4.6$. This novel method was applied for the determination of CPM in artificial and commercial preparations in comparison with the analytical method of CPM tablets in K.P.IV. The results obtained showed that the former was better in accuracy and time consumption than the latter.

  • PDF

An Analysis of the Sound Stopband in Periodically Corrugated 2-D Ducts (반복 주름을 갖는 이차원 덕트의 음파차단 해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Kim, Sang-Ryul;Lee, Seong-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • In this paper, the occurrence of a stopband phenomenon when an acoustic wave propagates through periodically corrugated ducts is discussed using theoretical and BEM analyses. A 2-D duct with sinusoidally corrugated upper and lower walls is considered. When the magnitude of the sinusoidal corrugation is sufficiently small compared to the duct's height, the wave equation is solved with the multiple scaling perturbation method. Then stopbands for Bragg and non-Bragg resonances are computed from the condition where frequency becomes a complex number. A 2-D BEM analysis is performed to compute insertion loss of the duct, and stopbands are confirmed as predicted by analytical analysis.

Optimization of Dies Angles to Improve the Dimensional Accuracy and Straightness of the Shaped Drawn Product based on the FE Simulation and the Taguchi Method (유한요소해석 및 다구찌법을 이용한 형상인발제품 치수정도 및 진직도 향상을 위한 다이스각 최적화)

  • Lee, Sang-Kon;Lee, Jae-Eun;Kim, Byung-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.6
    • /
    • pp.474-480
    • /
    • 2008
  • Recently, rods having irregular sections more complex than a rectangle or ellipse are necessary to produce mechanical parts. The cold shaped drawing process is used to obtain shaped drawn products with high levels of dimensional accuracy and quality. A cross roller guide, considered in this study, is one of the parts produced by shaped drawing process. A cross roller guide has a linear bearing system that rolls along a guide way. A cross roller guide is one of the most important components in terms of equipment because the quality of the product influences the precision linear motion. Therefore, the final dimensional accuracy of the linear rail in the shaped drawing is very important. The objective of this study is to find the optimized die angles to improve the dimensional accuracy and straightness of the final shaped drawn product. In order to achieve the aim of this study, design of experiment, FE-simulation, and the Taguchi method were used. Based on the analytical results, shaped drawing experiment has been performed to verify the result.