• Title/Summary/Keyword: compartment modeling

Search Result 65, Processing Time 0.026 seconds

Development of an Optimal Compartment Design System of Naval Ships Using Compartment Modeling and Ship Calculation Modules (구획 모델링 및 선박 계산 모듈을 이용한 함정의 최적 구획 배치 시스템 개발)

  • Roh, Myung-Il;Lee, Sang-Uk;Lee, Kyu-Yeul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Recently, compartment design of a naval ship for efficiently utilizing the limited spaces has become more important. However, the compartment design of the naval ship was not optimized like that of a commercial ship because of a number of design requirements. Thus, the task is being manually performed using the data of parent ships and designers' experiences. To improve this procedure, an optimal compartment design system, which can generate better compartment design result with the satisfaction of various design requirements, is developed in this study. Finally, to evaluate of the applicability of the developed system, it is applied to the compartment design of a 9,000ton missile destroyer(DDG). The result shows that the developed system can yield better result than original design.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT 에서의 간암-간 대조 곡선의 Simulation)

  • Kim, S.J.;Lee, K.H.;Kim, J.H.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.271-272
    • /
    • 1998
  • Contrast-enhanced CT has an important role in the assessment of liver lesions. However, the optimal protocol to get most effective result is not clear. The main principle for deciding injection protocol is to optimize lesion detectability by rapid scanning when lesion-to-liver contrast is maximum. For this purpose, we developed a physiological model of contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver was modeled in two paths. This dual supply character distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and the second is by portal vein. It is assumed that only hepatic artery can supply blood to hepatocellular carcinoma (HCC) compartment. It is known that this causes the difference of contrast enhancement between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using computer program Matlab, CT contrast-enhancement curves were simulated. Simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with mean enhancement curves from 24 patients exposed to the same protocols as simulation. These enhancement curves were in a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and analyzed the effects. These may help to optimize the scanning protocols for good diagnosis.

  • PDF

Numerical Study on the Validity of Scaling Law for Compartment Fires (구획 화재의 상사 법칙 유효성에 관한 수치해석 연구)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2014
  • In this study, to assess the validity of scaling law which was based on the ventilation factor and utilized in fields of compartment fires, numerical simulations were conducted on full- and 2/5 reduced-scale compartment fires using FDS and simulation results were compared with the previously published experimental data. The numerical modeling used in this study was verified by comparing the predicted temperature at several points of the upper layer with the experiment data. Temperature and concentration distribution inside of compartments and velocity profile at door of compartment are analyzed to assess the validity of scaling law. Comparison between the predicted results on the full- and reduced-scale compartments shows good agreements on the inner compartment flow patterns, outflowing flame patterns from the compartments, and vertical temperature distributions.

Parametric optimization of FPSO hull dimensions for Brazil field using sophisticated stability and hydrodynamic calculations

  • Lee, Jonghun;Kim, Byung Chul;Ruy, Won-Sun;Han, Ik Seung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.478-492
    • /
    • 2021
  • In this study, hull dimensions of an FPSO were optimized to maximize its operability at Brazil field. In contrast with the previous works which have used simplified models to evaluate some indicators related to stability and hydrodynamic performances of FPSOs for its own optimal design, we developed a generic hull and compartment modeler and sophisticated stability and hydrodynamic calculation modules. With the aid of the developed tools, the hull optimization was performed with initial dimensions of an FPSO originally designed for west Africa field. The optimization results indicated the relative importance of hydrodynamic performances compared with stability performances for the FPSO hull dimensioning by showing that there were 3 active constraints related to them, which were the natural periods of heave and roll and the maximum pitch angle under 1-year return period waves at full load condition. To the author's knowledge, this study is the first attempt to combine altogether the hull and compartment modeling and full set of stability and hydrodynamic calculations precisely to optimize an FPSO's hull dimensions within 30 min. Also, it is worthwhile to mention that the developed methods are generic enough to be applied to all types of ship-shaped offshore platforms.

Biosphere Modeling for Dose Assessment of HLW Repository: Development of ACBIO (고준위 방사성패기물 처분장 생태계 모델링을 위한 ACBIO개발)

  • Lee, Youn-Myoung;Hwang, Yong-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.73-100
    • /
    • 2008
  • For the purpose of evaluating dose rate to individual due to long-term release of nuclides from the HLW repository, a biosphere assessment model and the implemented code, ACBIO, based on BIOMASS methodology have been developed by utilizing AMBER, a general compartment modeling tool. To show its practicability and usability as well as to see the sensitivity of compartment scheme or parametric variation to concentration and activity in compartments as well as annual flux between compartments at their peak values, some calculations are made and investigated: For each case when changing the structure of compartments and GBIs as well as varying selected input Kd values, all of which seem very important among others, dose rate per nuclide release rate is separately calculated and analyzed. From the maximum dose rates (Bq/y), flux-to-dose conversion factors (Sv/Bq) for each nuclide were derived, which are to be used for converting the nuclide release rate appearing from the geosphere through various GBIs to dose rate (Sv/y) for individual in critical group. It has been also observed that compartment scheme, identification of possible exposure group and GBIs could be all highly sensitive to the final consequences in biosphere modeling.

  • PDF

Prediction of Sprinkler activation time using two-layer zonal model (Zone 모델을 이용한 스프링클러의 작동시간 예측)

  • 김명배;한용식;윤명오
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.15-18
    • /
    • 1996
  • A general description of sprinkler activation time in compartment-fire-generated smoke layers is made. For calculation of the time hot layer temperature is obtained from two-layer zonal model and time constant of sprinkler is measured. Upper-layer thickness at the instant of sprinkler activation is also presented with changes of opening area. The outputs of the present study provide inputs for the interaction modeling of sprinkler spray and compartment fire environment, which simulates fire suppression phenomena.

  • PDF

A Study on the 3-D Geometric Modeler for Safety Assessment of Damaged Ships (손상선박의 안전성평가를 위한 3차원 형상 모델러에 관한 연구)

  • 이동곤;이순섭;박범진
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.30-36
    • /
    • 2003
  • To improve survivability of damaged ship, assessment of stability and structural safety, and behavior analysis in wave is required. Prediction of sinking time, damage stability and structural strength considering progressive flooding and dynamic force in wave is very important. To do it, a geometric model which can be express damaged ship is prepared. This paper described the geometric modeler for survivability assessment of damaged ship. The modeler is developed based on 3-D geometric modeling kernel, ACIS. The hull form and compartment definition is available fundamentally. And requirement for modeler contains data generation and interface for hydrostatic calculation, behavior analysis, and longitudinal strength analysis and so on. To easy access modeling system by conventional user such as crew, user interface is developing.

Prediction of sprinkler activation time in compartment fire (구획화재에서의 스프링클러 작동시간 예측 연구)

  • 김명배;한용식
    • Fire Science and Engineering
    • /
    • v.10 no.4
    • /
    • pp.13-18
    • /
    • 1996
  • A general description of sprinkler activation time in compartment-fire-generated smoke layers is made. For calculation of the time hot layer temperature is obtained from two-layer zonal model and time constant of sprinkler is measured. Upper-layer thickness at the instant of sprinkler activation is also presented with changes of opening area. The output of the present study provide inputs for the interaction modeling of sprinkler spray and compartment fire environment, which simulates fire suppression phenomena. Futhermore, experiments are performed in mock-up with gasoline pool fire in order to evaluate the reliability of the model.

  • PDF

PREDICTION OF THE TRITIUM CONCENTRATION IN THE SOIL WATER AFTER THE OPERATION OF WOLSONG TRITIUM REMOVAL FACILITY

  • CHOI HEUI-JOO;LEE HANSOO;SUH KYUNG SUK;KANG HEE SUK
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.385-390
    • /
    • 2005
  • The effect of the Wolsong Tritium Removal Facility on the change of tritium concentration in the soil water was assessed by introducing a dynamic compartment model. For the mathematical modeling, the tritium in the environment was thought to come from two different sources. Three global tritium cycling models were compared with the natural background concentration. The dynamic compartment model was used to model the behavior of the tritium from the nuclear power plants at the Wolsong site. The source term for the dynamic compartment model was calculated with the dry and wet deposition rates. The area around the Wolsong nuclear power plants was represented by the compartments. The mechanisms considered in deriving the transfer coefficients between the compartments were evaporation, runoff, infiltration, hydrodynamic dispersion, and groundwater flow. We predicted what the change of the tritium concentration around the Wolsong nuclear power plants would be after future operation of the tritium removal facility to show the applicability of the model. The results showed that the operation of the tritium removal facility would reduce the tritium concentration in topsoil water quickly.