• Title/Summary/Keyword: comparison of diseases

Search Result 1,048, Processing Time 0.033 seconds

Evaluation of a rapid diagnostic kit "BIOLINE RSVTM" for the detection of respiratory syncytial virus (Respiratory Syncytial Virus 감염의 조기 진단 kit "바이오라인 알에스브이TM"의 평가)

  • Kim, So-Hee;Sung, Ji-Yeon;Yang, Mi-Ae;Eun, Byung-Wook;Lee, Jin-A;Choi, Eun-Hwa;Lee, Hoan-Jong
    • Pediatric Infection and Vaccine
    • /
    • v.14 no.1
    • /
    • pp.91-96
    • /
    • 2007
  • Purpose : This study was performed to evaluate a new rapid diagnostic kit (BIOLINE $RSV^{TM}$; Standard Diagnostics Inc., Yongin, Korea), a lateral-flow immunoassay, in the detection of respiratory syncytial virus (RSV) from the nasopharyngeal aspirates (NPA) of children with lower respiratory tract infections (LRTIs) in comparison with other diagnostic methods. Methods : Three hundred and nineteen NPAs were selected from a large pool of NPAs that had been obtained from children with LRTIs. All specimens had already been tested for RSV by culture and immunofluorescent (IF) test, and had been kept frozen. Tests with BIOLINE $RSV^{TM}$ were performed at least twice. All who conducted the experiments or interpreted the test results were blinded to the results of both culture and IF tests. Results : One hundred seven (97.3%) of 110 specimens that were positive for RSV by both culture and IF test, 29 (87.9%) of 33 that were positive by IF test only, 20 (76.9%) of 26 that were positive by culture only, and 140 (93.3%) of 150 that were negative by both methods were negative for RSV by BIOLINE $RSV^{TM}$. By combining the above results, the following 5 diagnostic values of BIOLINE $RSV^{TM}$ were determined in comparison with viral culture or IF test; sensitivity, 92.3% (156/169, 95% confidence interval [CI], 87.1-97.5%); specificity, 93.3% (140/150, 95% CI, 88.4-98.2%); positive predictive value, 94.0% (156/166, 95% CI, 89.5-98.5%); negative predictive value, 91.5% (140/143, 95% CI, 86.0-97.0%); and agreement, 95.9% (306/319, 95% CI, 92.1-99.7%), respectively. Conclusion : This study revealed that BIOLINE $RSV^{TM}$ demonstrated good sensitivity and specificity for the detection of RSV antigen from NPAs of children with LRTIs. Because of simple methods and quick results, this test may be useful for the diagnosis of RSV infection during the epidemic periods.

  • PDF

FEM Analysis of the Effects of Mouth guard material properties on the Head and Brain under Mandibular Impact (구강보호장치의 재료적인 특성이 하악골 충격 시악골 및 두부에 미치는 영향에 관한 유한요소분석)

  • Kang, Nam-Hyun;Kim, Hyung-Sub;Woo, Yi-Hyung;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.325-334
    • /
    • 2008
  • Statement of problem & Purpose: The purpose of this study was to investigate the effect of a mouth guard material properties on the skull and brain when they were under impact loads on mandible. Material and methods: Two customized mouth protectors having different material propeerst ieach other were made for a female Korean who had no history of brain trauma, no cerebral diseases, nomal occlusion and natural dentition. The 3D finite element model of human skull and brain scanned by means of computed tomography was constructed. The FEM model of head was composed of 407,825 elements and 82,138 nodes, including skull, brain, maxilla, mandible, articular disc, teeth and mouth guard. The stress concentrations on maxillary teeth, maxilla and skull with two mouth guards were evaluated under oblique impact load of 800N onto mandibular 3 loading points for 0.1sec. And the brain relative displacement was compared in two different mouth guard materials under same condition. Result and Conclusion: The results were as follows; 1. In comparison of von Mises stress on maxillary teeth, a soft mouth guard material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 2. In comparison of von Mises stress on maxilla and skull, A soft mouth protector material had significantly lower stress values on measuring point than a hard mouth protector materials (P < .05). 3. For impact loads on mandible, there were more stress concentrated area on maxilla and skull with hard mouth guard than soft with mouth protector. 4. For impact loads on mandible, brain relative displacement had little relation with mouth guard material properties. In results of this study, soft mouth guard materials were superior to hard mouth guard materials for mandible impact loads for prevention of sports injuries. Although the results of this study were not enough to figure out the roles of needed mouth guard material properties for a human head, we got some knowledge of the pattern about stress concentration and distribution on maxilla and skull for impact loads with soft or hard mouth protector. More studies are needed to substantiate the relationship between the mouth guard materials and sports injuries.

Comparison of dietary behavior, changes of diet, and food intake between 40~59 years old subjects living in urban and rural areas in Lao PDR (라오스 도시·농촌 지역별 40~59세 주민들의 식행동, 식생활변화 및 식품섭취 비교 연구)

  • Kim, Ji Yeon;Yi, Kyungock;Kang, Minah;Kang, Younhee;Lee, Gunjeong;Kim, Harris Hyun-soo;Hansana, Visanou;Kim, Yuri
    • Journal of Nutrition and Health
    • /
    • v.49 no.2
    • /
    • pp.111-124
    • /
    • 2016
  • Purpose: The current study was conducted for evaluation and comparison of dietary behavior and food intake in different regions of Lao PDR. Methods: The survey was conducted on 979 people aged 40~59 years old living in 25 urban provinces and 25 rural provinces in four districts (VTE Capital-Chanthabuly, Xaysetha, VTE Province-Phonhong, and Thoulakhom) of Laos. General demographic information, health status, and dietary behavior were surveyed using a questionnaire. Results: The literacy ratio (p = 0.000), education level (p = 0.000), asset ownership level (p = 0.000), and government and private employee ratio (p = 0.000) were higher in urban subjects compared with rural subjects. The mean value of weight (p = 0.000), waist circumference (p = 0.000), and diastolic blood pressure (p = 0.009) and alcohol consumption (p = 0.000), self-rated health status (p = 0.001), and the rate of obesity (p = 0.000) were significantly higher in urban subjects compared with rural subjects. However, the rate of current smoker was significantly higher in the rural group (p = 0.023). Meals are becoming more westernized by higher frequency of eating out, consumption of fatty meat and fried or stir-fried food in urban areas compared to rural areas. Urban subjects had relatively better balanced meals compared to rural subjects whereas they consumed insufficient meals per day and consumed meals irregularly compared to rural subjects. Intake of fruit and milk was significantly higher in urban subjects compared with rural subjects. However, the intake of vegetables was significantly higher in rural areas than urban areas. Conclusion: The result of this study showed that the traditional Lao diet is being replaced by an unhealthy western dietary pattern, which may be a risk factor for increasing development of non-communicable disease (NCD) in Lao PDR. Planning of proper personalized nutritional intervention and education in each area is needed to decrease the health risks of NCD.

Effect of Low-Level Laser to Oral Microorganisms (저출력 레이저가 구강미생물에 미치는 영향)

  • Yoon, In-Jong;Auh, Q-Schick;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.35 no.1
    • /
    • pp.31-39
    • /
    • 2010
  • This study is to observe the bacteriocidal effect of the Low Level Laser (LLL) against oral microorganisms which are related to the occurrence of periodontal diseases and oral malodors. The Porphyromonas gingivalis 2561 (P. gingivalis 2561) and Prevotella intermedia (Pr. intermedia) were treated with photosensitizing substance-toluidine blue O (TBO; C.I. 52040) and then radiated with the LLL which has 650nm wavelength for 1, 2, 3 and 5mins. continuously upon varying distances of 1, 2 and 3cm for each experimental groups. The results are as follows; 1. The P. gingivalis 2561 which was treated with TBO and then radiated with LLL at a distance of 3cm for 1min. showed 99.99% higher antibacterial effect in comparison to the experimental group treated only with TBO. 2. The Pr. intermedia which was treated with TBO and then radiated with LLL at a distance of 3cm for 1min. showed 99.8% higher antibacterial effect in comparison to the experimental group treated only with TBO. 3. The bacteriocidal effect of the P. gingivalis 2561 treated with TBO was found to gradually increase as the radiation time of LLL extended from 1min. to 3min. at 1min. intervals. 4. A slight decrease in bacteriocidal effect of the P. gingivalis 2561 was found as the radiation distance of LLL increased from 1cm to 3cm at 1cm intervals. 5. The bacteriocidal effect of the Pr. intermedia was found to slightly decrease as the radiation distance of LLL increased from 1cm to 3cm at 1cm. intervals. As the results shown above suggest, the bacteriocidal effect of LLL was found to increase as the radiation time extended and the distance shortened. Moreover, even the experimental group radiated with LLL at 3cm distance for 1min. which showed the lowest level of bacteriocidal effect, was found to have 99.8% higher bacteriocidal effect than the experimental group which was treated only with TBO and, therefore, this clearly shows the bacteriocidal effect of LLL against oral microorganisms. Thus, the use of LLL is thought to become very useful for suportive treatment for periodontitis and implantitis, and controlling oral malodors as long as it is used within the limits where there is no side effect.

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Comparison of Ultrasound-guided Suprapubic Aspiration with Urethral Catheterization in Infants (영유아에서 초음파 감시하 치골상부 방광천자와 도뇨관 채뇨의 비교)

  • Lee, Jung-Won;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.59-64
    • /
    • 2007
  • Purpose : Suprapubic aspiration(SPA) has been considered the "gold standard" for obtaining urine in non-toilet trained infants. Ultrasound(US)-guided SPA improves the success rate of the procedure and reduces the complications. However, many physicians perceive SPA as invasive and prefer the use of urethral catheterization (Ucat). We compared the success rate, complications and accuracy of US-guided SPA and Ucat. Methods : 121 infants who visited Ewha Womans University Mokdong Hospital with suspected urinary tract infection(UTI) were investigated. For the first study, the study infants were randomly assigned to either the US-guided SPA(n=32) or Ucat(n=32) groups. The success rate and complications of both procedures were compared. For the second study, US-guided SPA and Ucat were performed simultaneously(n=57). The accuracy of urethral catheterization was subsequently analyzed. The criteria for success was defined as the collection of more than 0.5 mL of urine. UTI was diagnosed by the presence of uropathogens over 105 colony-forming units (CFU)/mL. Results : The overall success rate of the US-guided SPA was 96.9%(71.9% in first attempts, 25.0% in second attempts) which was not significantly different compared to 96.9%(90.6% in first attempts, 6.3% in second attempts) in the Ucat(P>0.05) group. The aspirated urine volume was $7.4{\pm}3.7mL$ in the US-guided SPA group, which was not significantly different to $4.5{\pm}2.6mL$ in the Ucat(P>0.05) group. The accuracy of Ucat in comparison to the US guided SPA was low with sensitivity 59.5%, specificity 86.6%, false-positive rate 13.3% and false-negative rate 40.5%. Conclusion : US-guided SPA should be encouraged as the best method to collect the urine in non-toilet trained infants with UTI.

  • PDF

A Comparison of Health Behavior between Rural and Urban in Soonchun City (순천시 지역적 특성에 따른 건강 행태 비교)

  • Min, Hye-Young;Oh, Hyohn-Joo
    • Journal of agricultural medicine and community health
    • /
    • v.24 no.1
    • /
    • pp.49-63
    • /
    • 1999
  • The objective of the study was to examine and compare health behavior between rural area and urban area in Soonchun city. Data were collected through personal interviews from 25, April to 30, May in 1998. Questions were asked to the rural area residents(n=399) and urban area residents(n=149) about their health behaviors, including such as self-recognition of health status, health related behaviors(smoking, drinking, eating habit, and exercising), status of disease and prevention, and utilization of hospital. As we examine the demographic characteristics, rural area residents were more aged(p<0.001) than urban area residents. And the urban residents had higher education(p<0.01), higher income(p<0.01) and higher health care cost(p<0.01) than rural residents. There were difference in health status existed between rural and urban residents. Rural residents had poorer health status(p<0.01) than urban residents, and however urban residents had more anxiety about their health(p<0.01) than rural residents. Comparison of the health related behavior between rural and urban area residents, rural residents were more likely to smoke(p<0.05), less intake of milk(p<0.01), do not exercise(p<0.01), and less try to lose their weight(p<0.01) than urban residents. Rural resident used to suffer from chronic diseases than urban residents(p<0.01). Consideration of health care need for rural residents are required due to the results shown as above. Therefore, the health care center, where most of the rural residents depend on for their treatment and prevention of disease, should make inquiries about resident's health care need and evaluate the important information sources for construction of a health care information system.

  • PDF

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves (수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교)

  • Kang Joon Kyu;Hong Joon Hwa;Kim Hyung Tai;Park In Duk;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.496-500
    • /
    • 2005
  • There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.

The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP (Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과)

  • Chin, Jae-Yong;Lim, Chae-Man;Koh, Youn-Suck;Park, Pyung-Whan;Choi, Jong-Moo;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.201-209
    • /
    • 1996
  • Background : Auto-PEEP which develops when expiratory lung emptying is not finished until the beginning of next inspiration is frequently found in patients on mechanical ventilation. Its presence imposes increased risk of barotrauma and hypotension, as well as increased work of breathing (WOB) by adding inspiratory threshold load and/or adversely affecting to inspiratory trigger sensitivity. The aim of this study is to evaluate the relationship of auto-PEEP with WOB and to evaluate the effect of PEEP applied by ventilator (external PEEP) on WOB in patients with auto-PEEP. Method : 15 patients, who required mechanical ventilation for management of acute respiratory failure, were studied. First, the differences in WOB and other indices of respiratory mechanics were examined between 7 patients with auto-PEEP and 8 patients without auto-PEEP. Then, we applied the 3 cm $H_2O$ of external PEEP to patients with auto-PEEP and evaluated its effects on lung mechanics as well as WOB. Indices of respiratory mechanics including tidal volume ($V_T$), repiratory rate, minute ventilation ($V_E$), peak inspiratory flow rate (PIFR), peak expiratory flow rate (PEFR), peak inspiratory pressure (PIP), $T_I/T_{TOT}$, auto-PEEP, dynamic compliance of lung (Cdyn), expiratory airway resistance (RAWe), mean airway resistance (RAWm), $p_{0.1}$, work of breathing performed by patient (WOB), and pressure-time product (PTP) were obtained by CP-100 Pulmonary Monitor (Bicore, USA). The values were expressed as mean $\pm$ SEM (standard error of mean). Results : 1) Comparison of WOB and other indices of respiratory mechanics in patients with and without auto-PEEP : There was significant increase in WOB ($l.71{\pm}0.24$ vs $0.50{\pm}0.19\;J/L$, p=0.007), PTP ($317{\pm}70$ vs $98{\pm}36\;cm$ $H_2O{\cdot}sec/min$, p=0.023), RAWe ($35.6{\pm}5.7$ vs $18.2{\pm}2.3\;cm$ H2O/L/sec, p=0.023), RAWm ($28.8{\pm}2.5$ vs $11.9{\pm}2.0cm$ H2O/L/sec, p=0.001) and $P_{0.1}$ ($6.2{\pm}1.0$ vs 2.9+0.6 cm H2O, p=0.021) in patients with auto-PEEP compared to patients without auto-PEEP. The differences of other indices including $V_T$, PEFR, $V_E$ and $T_I/T_{TOT}$ showed no significance. 2) Effect of 3 cm $H_2O$ external PEEP on respiratory mechanics in patients with auto-PEEP : When 3 cm $H_2O$ of external PEEP was applied, there were significant decrease in WOB ($1.71{\pm}0.24$ vs $1.20{\pm}0.21\;J/L$, p=0.021) and PTP ($317{\pm}70$ vs $231{\pm}55\;cm$ $H_2O{\cdot}sec/min$, p=0.038). RAWm showed a tendency to decrease ($28.8{\pm}2.5$ vs $23.9{\pm}2.1\;cm$ $H_2O$, p=0.051). But PIP was increased with application of 3 cm $H_2O$ of external PEEP ($16{\pm}2$ vs $22{\pm}3\;cm$ $H_2O$, p=0.008). $V_T$, $V_E$, PEFR, $T_I/T_{TOT}$ and Cdyn did not change significantly. Conclusion : The presence of auto-PEEP in mechanically ventilated patients was accompanied with increased WOB performed by patient, and this WOB was decreased by 3 cm $H_2O$ of externally applied PEEP. But, with 3 cm $H_2O$ of external PEEP, increased PIP was noted, implying the importance of close monitoring of the airway pressure during application of external PEEP.

  • PDF

The Central Venous Catheter-related Infection of Chlorhexidine-silver Sulfadiazine Coated Catheters in Medical ICU (내과계 중환자실 환자에서 Chlorhexidine-silver Sulfadiazine Coated Catheter의 중심정맥관 감염에 대한 연구)

  • Jung, Young Ju;Koh, Younsuck;Lim, Chae-Man;Lee, Jae Seung;Yu, Mi Hyun;Oh, Yeon Mok;Shim, Tae Sun;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Hong, Sang-Bum
    • Tuberculosis and Respiratory Diseases
    • /
    • v.59 no.4
    • /
    • pp.389-396
    • /
    • 2005
  • Background : Central venous catheters(CVCs) area major source of nosocomial infection. Chlorhexidine-silver sulfadiazine coated catheters (CHSS) were developed to reduce the rate of CVC infection. However, the clinical effectiveness of CHSS in comparison wth non-coated catheter (NCC) remains to be evaluated. Methods : From January 2004 to December 2004 in medical intensive care unit (ICU) of Asan Medical Center, CVCs were inserted in 446 cases. We retrospectively analyzed characteristics of patients and catheterization,the catheter-related infection rate and colonization, microbiologic findings, and insertion sites (subclavian, jugular, femoral) according to the type of inserted CVCs (NCC: 187 cases, CHSS: 259 cases). Catheter related infection is defined as catheter related bacteremia and catheter related non-bacteremic sepsis. Results : 1) The mean age of the patients in each group was $62{\pm}16$ years, $63{\pm}15$ years (p=0.42), and sex ratio 94:50, 141:69 (p=0.9) in NCC and CHSS. Duration of ICU admission ($29{\pm}37$, $26{\pm}44$ p=0.42), duration of mechanical ventilation ($17{\pm}22$, $15{\pm}19$ p=0.17), and APACHE III score at the time of CVC insertion ($81{\pm}34$, $82{\pm}37$ p=0.61) were not different between both groups. 2) Mean duration of catheterization was 118 in NCC and 119 in CHSS (p=0.98). Number of catheter-days was 2176 days in NCC and 3035 days in CHSS. Catheter-related infection occurred in 9 (4.8%) cases receiving NCC and 4 cases (1.5%) receiving CHSS. Catheterrelated infection incidence per 1000 catheter-days was 4.1 and 1.3, respectively (p=0.04). CHSS was associated with a significant reduction of infection in jugular catheters regarding to insertion sites (p=0.01). 3) Microorganisms causing infection were Staphylococcus aureus (n=3), Candida (n=3), coagulase-negative Staphylococci (n=2), and Klebsiella (n=1) in NCC, and Candida species (n=2), coagulase-negative Staphylococci (n=2), Proteus (n=1) in CHSS. Conclusion : CHSS has significantly reduced the episodes of infection compared to NCC in jugular catheterization in medical ICU.