• Title/Summary/Keyword: comparison measurement

Search Result 3,147, Processing Time 0.026 seconds

Comparison of Distance of Subacromial Space Using Ultrasonographic Measurement on Arm Positions of Shoulder Injured Patients (견부손상환자의 팔의 자세에 따른 초음파 영상을 이용한 견봉하공간 거리의 비교)

  • Jee, Eun-Mi;Kim, Suhn-Yeop;Park, Ji-Whan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.397-406
    • /
    • 2011
  • Purpose : Recently ultrasound images has been used to measure the subacromial space with a linear measurement of the acromiohumeral distance. The purpose of this study was to comparison of distance of subacromial space using ultrasonographic measurement on arm positions of shoulder injured patients. Methods : The subjects were 30 shoulder injured patients (19 males and 11 females). Ultrasonography was performed to measure subacromial space during each shoulder resting position, $45^{\circ}$ abduction, internal rotation with $45^{\circ}$ abduction and external rotation with $45^{\circ}$ abduction. Results : Subacromial space was a significantly difference between injured arm and normal arm at shoulder resting position. At $45^{\circ}$ abduction, subacromial space was narrowing significantly between injured arm and normal arm. At external rotation with $45^{\circ}$ abduction, subacromial space were wider in normal arm than in injured arm but it was not significantly. Intra-observer reliability for ultrasonography measurement of subacromial distance was excellent (.96~.99). Conclusion : These results identified that positions of injured shoulder was related to subacromion space.

Comparison of Human Responses to Transportation Noise in Monaural and Binaural Hearing, Part I: Measurement and Analysis (교통소음의 모노럴과 바이노럴 청감 비교 연구 I: 측정 및 분석)

  • Kim, Jaehwan;Lim, Chang-Woo;Jeong, Wontae;Hong, Jiyoung;Cheung, Wansup;Lee, Soogab
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1268-1278
    • /
    • 2004
  • Measurement of noise is not only to know the information of acoustic pressure but to assess human response to noise. To find human response to transportation noise through the laboratory study we have to measure and reproduce noise. The method of noise reproduction is largely divided into monaural and binaural techniques. But human fundamentally hears sound through both ears, referred as binaural hearing. Binaural signal is different from monaural signal because it includes more information of physical phenomena like acoustical reflection, diffraction and refraction. Especially head and pinna play an important role in perceiving change of signal origin. So, the amplitude of binaural signal is higher than that of monaural signal and spectrum of both signals is discriminated. Most of assessment and regulation of transportation noise are, however, based on monaural measurement techniques. The quantitative difference between monaural and binaural measurement is investigated in this study. Comparison on several transportation noisesshows defect of information in monaural measurements.

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography (초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden (전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술)

  • Jung Jae Kap;Kim Han Jun;Kwon Sung Won;Kim Myung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.6
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

A Study on the Measurement for Table Deflection using Laser Interferometer and Simulation (레이저를 이용한 테이블 처짐 측정과 시뮬레이션에 관한 연구)

  • 김민주
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.55-63
    • /
    • 1999
  • The acceleration of the performance of machine tools influences the development of the semi-conductor and optical technology as the development of NC and measurement technology. Because the measurement has been done to unload condition without considering of mechanical stiffness in the case of machining center as we measure the quasi-static error of machine tools on general study people who works on the spot has many problems on the data value. Also there are no satisfiable results until now in spite of many studys about this because the deflections of the table and the shaft supporting a workpiece influence, influence the accuracy of the table and shaft supporting a workpiece influence the accuracy of the workpiece. And there is doubt about the inspection method of measured error. In this paper Therefor we will help working more accurately on the spot by measuring analyzing displaying the defoec-tion of the table and support shaft when we load on the table and the support shaft of machining center using laser interfer-ometer. Also we try to settle new conception of the measurement method and more accurate grasp of the deflection tenden-cy by verifing the tendency of the error measured through the comparison of the simulated error measured through the comparison of the simulated error using ANSYS a common finite element analysis program which is able to measure heat deformation material deformation and error resulted from this study.

  • PDF

Study on the Defects Detection in Composites by Using Optical Position and Infrared Thermography

  • Kwon, Koo-Ahn;Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Choi, Won Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.2
    • /
    • pp.130-137
    • /
    • 2016
  • Non-destructive testing methods for composite materials (e.g., carbon fiber-reinforced and glass fiber-reinforced plastic) have been widely used to detect damage in the overall industry. This study detects defects using optical infrared thermography. The transient heat transport in a solid body is characterized by two dynamic quantities, namely, thermal diffusivity and thermal effusivity. The first quantity describes the speed with thermal energy diffuses through a material, whereas the second one represents a type of thermal inertia. The defect detection rate is increased by utilizing a lock-in method and performing a comparison of the defect detection rates. The comparison is conducted by dividing the irradiation method into reflection and transmission methods and the irradiation time into 50 mHz and 100 mHz. The experimental results show that detecting defects at 50 mHz is easy using the transmission method. This result implies that low-frequency thermal waves penetrate a material deeper than the high-frequency waves.

Comparison of Cavitation Patterns between Model Scale Observations using Model and Full-Scale Wakes and Full Scale Observations for a Propeller of Crude Oil Carrier (원유운반선 프로펠러의 모형 및 실선 축척 반류에서의 공동현상과 실선에서 관측된 공동현상의 비교)

  • Choi, Gil-Hwan;Chang, Bong-Jun;Hur, Jae-Wook;Cho, Dae-Seung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this paper, cavitation patterns of model tests were compared with those of full-scale measurement for a propeller of crude oil carrier which was suffered from erosions on suction side of blade tip region. Cavitation tests were performed at design and ballast draft using model and full scale nominal wakes. A model ship and wire mesh method was used for the simulation of wake patterns of model nominal wakes. For the prediction of full-scale wake patterns, a RANS solver(Fluent 6.3) was used and wire mesh method was used for the simulation of the full scale wakes. Comparison results show that cavitation patterns using predicted full-scale wake patterns are closer to cavitation patterns of full-scale measurement at ballast draft condition. Also, cloud cavitations were observed on the position of eroded area at both full-scale measurement and cavitation tests using simulated full-scale wake patterns.

Comparison of the 6-DOF Motion Sensor and Stain Gauge Data for Ice Load Estimation on IBRV ARAON (쇄빙연구선 ARAON호의 빙하중 추정을 위한 6자유도 운동계측 및 스트레인 게이지 데이터의 비교 분석)

  • Min, Jung Ki;Cheon, Eun-Jee;Kim, Jin Myung;Lee, Sang Chul;Choi, Kyungsik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.529-535
    • /
    • 2016
  • This study focuses on the comparison of measured data from 6-DOF motion sensor and strain gauge installed in the IBRV ARAON during 2015 summer voyage in the Arctic. Procedures to calculate the global ice load from MotionPak II inertial measurement system and the local load from stain gauge system are discussed. The ship's speed and peak load are determined in the concept of an ice collision "event". It is found that the peak values in the global ice calculated form whole ship motion analysis fall in the range of 1.5~3 times of the local ice load based in strain gauge measurement.

The Development of Exercise Accuracy Measurement Algorithm Supporting Personal Training's Exercise Amount Improvement

  • Oh, Seung-Taek;Kim, Hyeong-Seok;Lim, Jae-Hyun
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.57-67
    • /
    • 2022
  • The demand for personal training (PT), through which high exercise effects can be achieved within short-term, has recently increased. PT can achieve an exercise amount improvement effect, only if accurate postures are maintained upon performing PT, and exercise with inaccurate postures can cause injuries. However, research is insufficient on exercise amount comparisons and judging exercise accuracy on PT. This study proposes an exercise accuracy measurement algorithm and compares differences in exercise amounts according to exercise postures through experiments using a respiratory gas analyzer. The exercise accuracy measurement algorithm acquires Euler anglesfrom major body parts operated upon exercise through a motion device, based on which the joint angles are calculated. By comparing the calculated joint angles with each reference angle in each exercise step, the status of exercise accuracy is judged. The calculated results of exercise accuracy on squats, lunges, and push-ups showed 0.02% difference in comparison with actually measured results through a goniometer. As a result of the exercise amount comparison experiment according to accurate posture through a respiratory gas analyzer, the exercise amount was higher by 45.19% on average in accurate postures. Through this, it was confirmed that maintaining accurate postures contributes to exercise amount improvement.

Strategies Used by Young Children in Weight Measurement Tasks ($4{\sim}6$세 유아의 무게 측정전략 발달에 관한 연구)

  • Rhee, Bo-Young;Kim, Ju-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.45 no.7
    • /
    • pp.49-60
    • /
    • 2007
  • The purpose of this study was to analyze the weight measurement tasks according to children's ages and whether 4-to 6-year-old children use proper measurement equipment to measure weight. The study subjects were 105 preschool children: 37,38, and 30 4-, 5-, and 6-year-old children, respectively. The results showed that young children use 3 to 4 strategies. They used a strategy to estimate objects visually on the first step in measurement by direct comparison. On the second step, in measurement by nonstandard unit, they held up objects with one hand or two hands. That is, two strategies were shown in measuring objects with hands in this second step. On the third step, which is measured by standard unit, they used a strategy to choose the equal arm balance out of suggested measurement equipment.