• Title/Summary/Keyword: comparison accuracy

Search Result 3,210, Processing Time 0.034 seconds

Development of Regularized Expectation Maximization Algorithms for Fan-Beam SPECT Data (부채살 SPECT 데이터를 위한 정칙화된 기댓값 최대화 재구성기법 개발)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Soo-Jin;Kim, Kyeong-Min;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.464-472
    • /
    • 2005
  • Purpose: SPECT using a fan-beam collimator improves spatial resolution and sensitivity. For the reconstruction from fan-beam projections, it is necessary to implement direct fan-beam reconstruction methods without transforming the data into the parallel geometry. In this study, various fan-beam reconstruction algorithms were implemented and their performances were compared. Materials and Methods: The projector for fan-beam SPECT was implemented using a ray-tracing method. The direct reconstruction algorithms implemented for fan-beam projection data were FBP (filtered backprojection), EM (expectation maximization), OS-EM (ordered subsets EM) and MAP-EM OSL (maximum a posteriori EM using the one-step late method) with membrane and thin-plate models as priors. For comparison, the fan-beam protection data were also rebinned into the parallel data using various interpolation methods, such as the nearest neighbor, bilinear and bicubic interpolations, and reconstructed using the conventional EM algorithm for parallel data. Noiseless and noisy projection data from the digital Hoffman brain and Shepp/Logan phantoms were reconstructed using the above algorithms. The reconstructed images were compared in terms of a percent error metric. Results: for the fan-beam data with Poisson noise, the MAP-EM OSL algorithm with the thin-plate prior showed the best result in both percent error and stability. Bilinear interpolation was the most effective method for rebinning from the fan-beam to parallel geometry when the accuracy and computation load were considered. Direct fan-beam EM reconstructions were more accurate than the standard EM reconstructions obtained from rebinned parallel data. Conclusion: Direct fan-beam reconstruction algorithms were implemented, which provided significantly improved reconstructions.

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

A Double-Blind Comparison of Paroxetine and Amitriptyline in the Treatment of Depression Accompanied by Alcoholism : Behavioral Side Effects during the First 2 Weeks of Treatment (주정중독에 동반된 우울증의 치료에서 Paroxetine과 Amitriptyline의 이중맹 비교 : 치료초기 2주 동안의 행동학적 부작용)

  • Yoon, Jin-Sang;Yoon, Bo-Hyun;Choi, Tae-Seok;Kim, Yong-Bum;Lee, Hyung-Yung
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.277-287
    • /
    • 1996
  • Objective : It has been proposed that cognition and related aspects of mental functioning are decreased in depression as well as in alcoholism. The objective of the study was to compare behavioral side effects of paroxetine and amitriptyline in depressed patients accompanied by alcoholism. The focused comparisons were drug effects concerning psychomotor performance, cognitive function, sleep and daytime sleepiness during the first 2 weeks of treatment. Methods : After an alcohol detoxification period(3 weeks) and a washout period(1 week), a total of 20 male inpatients with alcohol use disorder (DSM-IV), who also had a major depressive episode(DSM-IV), were treated double-blind with paroxetine 20mg/day(n=10) or amitriptyline 25mg/day(n=10) for 2 weeks. All patients were required to have a scare of at least 18 respectively on bath the Hamilton Rating Scale far Depression(HAM-D) and Beck Depression Inventory(BDI) at pre-drug baseline. Patients randomized to paroxetine received active medication in the morning and placebo in the evening whereas those randomized to amitriptyline received active medication in the evening and placebo in the morning. All patients performed the various tasks in a test battery at baseline and at days 3, 7 and 14. The test battery included : critical flicker fusion threshold for sensory information processing capacity : choice reaction time for gross psychomotor performance : tracking accuracy and latency of response to peripheral stimulus as a measure of line sensorimotor co-ordination and divided attention : digit symbol substitution as a measure of sustained attention and concentration. To rate perceived sleep and daytime sleepiness, 10cm line Visual analogue scales were employed at baseline and at days 3, 7 and 14. The subjective rating scales were adapted far this study from Leeds sleep Evaluation Questionnaire and Epworth Sleepiness Scale. In addition a comprehensive side effect assessment, using the UKU side effect rating scale, was carried out at baseline and at days 7 and 14. The efficacy of treatment was evaluated using HAM-D, BDI and clinical global impression far severity and improvement at days 7 and 14. Results : The pattern of results indicated thai paroxetine improved performance an mast of the lest variables and also improved sleep with no effect on daytime sleepiness aver the study period. In contrast, amitriptyline produced disruption of performance on same tests and improved sleep with increased daytime sleepiness in particular at day 3. On the UKU side effect rating scale, mare side effects were registered an amitriptyline. The therapeutic efficacy was observed in favor of paroxetine early in day 7. Conclusion : These results demonstrated thai paroxetine in much better than amitriptyline for the treatment of depressed patients accompained by alcoholism at least in terms of behavioral safety and tolerability, furthermore the results may assist in explaining the therapeutic outcome of paroxetine. For example, and earlier onset of antidepressant action of paroxetine may be caused by early improved cognitive function or by contributing to good compliance with treatment.

  • PDF

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Performance Evaluation of Machine Learning and Deep Learning Algorithms in Crop Classification: Impact of Hyper-parameters and Training Sample Size (작물분류에서 기계학습 및 딥러닝 알고리즘의 분류 성능 평가: 하이퍼파라미터와 훈련자료 크기의 영향 분석)

  • Kim, Yeseul;Kwak, Geun-Ho;Lee, Kyung-Do;Na, Sang-Il;Park, Chan-Won;Park, No-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.5
    • /
    • pp.811-827
    • /
    • 2018
  • The purpose of this study is to compare machine learning algorithm and deep learning algorithm in crop classification using multi-temporal remote sensing data. For this, impacts of machine learning and deep learning algorithms on (a) hyper-parameter and (2) training sample size were compared and analyzed for Haenam-gun, Korea and Illinois State, USA. In the comparison experiment, support vector machine (SVM) was applied as machine learning algorithm and convolutional neural network (CNN) was applied as deep learning algorithm. In particular, 2D-CNN considering 2-dimensional spatial information and 3D-CNN with extended time dimension from 2D-CNN were applied as CNN. As a result of the experiment, it was found that the hyper-parameter values of CNN, considering various hyper-parameter, defined in the two study areas were similar compared with SVM. Based on this result, although it takes much time to optimize the model in CNN, it is considered that it is possible to apply transfer learning that can extend optimized CNN model to other regions. Then, in the experiment results with various training sample size, the impact of that on CNN was larger than SVM. In particular, this impact was exaggerated in Illinois State with heterogeneous spatial patterns. In addition, the lowest classification performance of 3D-CNN was presented in Illinois State, which is considered to be due to over-fitting as complexity of the model. That is, the classification performance was relatively degraded due to heterogeneous patterns and noise effect of input data, although the training accuracy of 3D-CNN model was high. This result simply that a proper classification algorithms should be selected considering spatial characteristics of study areas. Also, a large amount of training samples is necessary to guarantee higher classification performance in CNN, particularly in 3D-CNN.

Estimation of Soil Surface Temperature by Heat Flux in Soil (Heat flux를 이용한 토양 표면 온도 예측)

  • Hur, Seung-Oh;Kim, Won-Tae;Jung, Kang-Ho;Ha, Sang-Keon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.3
    • /
    • pp.131-135
    • /
    • 2004
  • This study was carried out for the analysis of temperature characteristics on soil surface using soil heat flux which is one of the important parameters forming soil temperature. Soil surface temperature was estimated by using the soil temperature measured at 10 cm soil depth and the soil heat flux measured by flux plate at 5 cm soil depth. There was time lag of two hours between soil temperature and soil heat flux. Temperature changes over time showed a positive correlation with soil heat flux. Soil surface temperature was estimated by the equation using variable separation method for soil surface temperature. Arithmetic mean using temperatures measured at soil surface and 10 cm depth, and soil temperature measured at 5 cm depth were compared for accuracy of the value. To validate the regression model through this comparison, F-validation was used. Usefulness of deductive regression model was admitted because intended F-value was smaller than 0.001 and the determination coefficient was 0.968. It can be concluded that the estimated surface soil temperatures obtained by variable separation method were almost equal to the measured surface soil temperature.

Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system (국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교)

  • Park, Hye-Young;Cho, Hyeon-Je;Kim, Eun-Mi;Hur, Gham;Kim, Yong-Hoon;Lee, Byung-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • Purpose : To compare free-breathing and respiratory-triggered diffusion-weighted imaging on 1.5-T MR system in the detection of hepatic lesions. Materials and Methods: This single-institution study was approved by our institutional review board. Forty-seven patients (mean 57.9 year; M:F = 25:22) underwent hepatic MR imaging on 1.5-T MR system using both free-breathing and respiratory-triggered diffusion-weighted imaging (DWI) at a single examination. Two radiologists retrospectively reviewed respiratory-triggered and free-breathing sets (B50, B400, B800 diffusion weighted images and ADC map) in random order with a time interval of 2 weeks. Liver SNR and lesion-to-liver CNR of DWI were calculated measuring ROI. Results : Total of 62 lesions (53 benign, 9 malignant) that included 32 cysts, 13 hemangiomas, 7 hepatocellular carcinomas (HCCs), 5 eosinophilic infiltration, 2 metastases, 1 eosinophilic abscess, focal nodular hyperplasia, and pseudolipoma of Glisson's capsule were reviewed by two reviewers. Though not reaching statistical significance, the overall lesion sensitivities were increased in respiratory-triggered DWI [reviewer1: reviewer2, 47/62(75.81%):45/62(72.58%)] than free-breathing DWI [44/62(70.97%):41/62(66.13%)]. Especially for smaller than 1 cm hepatic lesions, sensitivity of respiratory-triggered DWI [24/30(80%):21/30(70%)] was superior to free-breathing DWI [17/30(56.7%):15/30(50%)]. The diagnostic accuracy measuring the area under the ROC curve (Az value) of free-breathing and respiratory-triggered DWI was not statistically different. Liver SNR and lesion-to-liver CNR of respiratory-triggered DWI ($87.6{\pm}41.4$, $41.2{\pm}62.5$) were higher than free-breathing DWI ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) (p value < 0.001, respectively). Conclusion: Respiratory-triggered diffusion-weighted MR imaging seemed to be better than free-breathing diffusion-weighted MR imaging on 1.5-T MR system for the detection of smaller than 1 cm lesions by providing high SNR and CNR.

Diagnostic Value of Cyfra 21-1 in Differential Diagnosis of Pleural Effusion (흉수의 감별 전단으로 Cyfra 21-1의 진단적 가치)

  • Lee, Hak-Jun;Lee, Kwan-Ho;Shin, Kyeong-Cheol;Shin, Chang-Jin;Park, Hye-Jung;Mun, Yeung-Chul;Lee, Kyung-Hee;Chung, Jin-Hong;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.50-56
    • /
    • 1999
  • Background : Pleural effusion is a common clinical problem and many clinical and laboratory evaluations, such as tumor marks, have been studied to discriminate malignant pleural fluid from benign pleural fluid. However their usefulness in the diagnosis of pleural effusion is still not established fully. We studied the diagnostic value of cyfra 21-1 in diagnosis of malignant pleural effusion. Methods: Pleural fluid was obtained from 45 patients with malignant diseases(32 lung cancer patients, 13 metastatic malignant diseases) and 47 patients with benign diseases. The level of cyfra 21-1 in the pleural fluid and serum were determined using a CYFRA 21-1 enzyme immunoassay kit(Cis-Bio International Co.). The t-test was used for comparison between two diseases groups and receiver operating characteristic(ROC) curves were constructed by calculating the sensitivities and specificities of the cyfra 21-1 at several points to determine the diagnostic accuracy of the cyfra 21-1. Results: In patients with primary lung cancer, the level of cyfra 21-1 in the pleural fluid was significantly higher than those of patients with benign diseases and had positive correlations between the level of cyfra 21-1 in the pleural fluid and serum levels. In the ROC curve analysis of the pleural fluid, the curve for primary lung cancer group was located closer to the left upper comer and the cut off value, sensitivity and specificity of the cyfra 21-1 of the primary lung cancer group was determined as 22.25ng/ml, 81.8% and 78.7% respectively. Conclusions: Our data indicates that the measurement of cyfra 21-1 level in pleural effusion has useful diagnostic value to discriminate malignant pleural effusion in primary lung cancer from benign pleural effusion.

  • PDF

The Comparison of Video Assisted Thoracic Surgery (VATS) with 10 mm Thoracoscopy to 2 mm Thoracoscopy for Primary Spontaneous Pneumothorax (원발성 자연 기흉에서 10 mm와 2 mm 비디오 흉강경 수술의 비교)

  • Hwang Jin-Wook;Jo Won-Min;Min Byoung-Ju;Son Ho-Sung;Lee In-Sung;Shin Jae-Seung
    • Journal of Chest Surgery
    • /
    • v.38 no.9 s.254
    • /
    • pp.627-632
    • /
    • 2005
  • Background: The video-assisted thoracic surgery (VATS) with 2 mm thoracoscopy in primary spontaneous pneumothorax (PSP) was known to be unreliable in its accuracy and recurrence rate. We compared 10 mm VATS with 2 mm VATS in the results of operation. Material and Method: From Sept. 1998 to Dec. 2002, 176 cases (10 mm VATS; 73 cases, 2 mm VATS; 103 cases) of PSP were treated by VATS blob resection at Korea University Ansan Hospital. 10 mm thoracoscope, 5 mm port, and 5 mm instruments were used in 10 mm VATS group, and 2 mm thoracoscope, 2 mm ports and 2 mm instruments used in 2 mn VATS group. In the two groups, staples were inserted through 11.5 mm port for chest tube. Result: The mean follow-up duration was 20,8$\pm$16.1 months in 10 mm VATS group, and 13.9 $\pm$8.2 months in 2 mm VATS. The most common indication of operation was a recurrent pneumothorax ($34\%$) in 10 mm VATS and patient's desire ($40\%$) in 2 mm VATS, respectively. The operation time, number of staples used in operation, postoperative chest tube keeping days, postoperative total amount of drainage, and postoperative hospitalization days were statistically lower in 2 mm VATS. Other significant variables affecting the operation time in linear regression analysis were the number of staples that used in operation, the presence of pleural adhesion, and type of pleurodesis and thoracoscope used in operation. However, $R^2$ values were lower than 0.1. The postoperative recurrence rate was $2.7\%$ in 10 mm VATS and $2.9\%$ in 2 mm VATS. It was not significant statistically. Recurrent cases developed within 1 year in both groups but the difference was statistically insignificant. Conclusion: Although there were differences in follow-up duration between two groups, the operation time, number of staples that used in operation, postoperative chest tube keeping days, postoperative total amount of drainage, and postoperative hospitalization days were statistically lower in 2 mm VATS. And in 2 mm VATS, there were no technical difficulties during operation and no differences in recurrence rate from 10 mm VATS. As a result, we suggest that 2 mm VATS can be used in the treatment of PSP.

Additivity of Ileal Crude Protein Digestibility and Comparison of Digestibility with Methodological Consideration in Broilers (육계에서의 회장 조단백질 소화율 가산성 평가 및 방법론적 소화율 비교)

  • Lee, Jinyoung;Kong, Changsu
    • Korean Journal of Poultry Science
    • /
    • v.44 no.4
    • /
    • pp.253-258
    • /
    • 2017
  • This study was aimed at evaluating the additivity of crude protein digestibility in mixed diets of corn and soybean meal (SBM), and comparing direct and indirect methods for evaluating crude protein (CP) digestibility. Totally, five hundred and twenty-five 18-day-old broiler chickens were grouped into 7 blocks based on body weight, and randomly allocated to 6 treatment groups in a randomized complete block design. The basal diet, diet 3, was corn-SBM-based, containing 65% corn and 28% SBM. Diets 1 and 5 contained corn and SBM, respectively, as the sole CP source. To use the difference method, 2 diets, diets 2 and 4, were prepared by mixing corn and SBM at the expense of the basal diet, respectively. Diet 2 contained 79% corn and 14% SBM, and diet 4 contained 32.5% corn and 34% SBM. To evaluate the additivity of digestibility values, the difference between measured values for the mixed diets (diets 2, 3, and 4) and predicted values calculated using the measured values for diets 1 and 5 was examined. The apparent (AID) and standardized (SID) ileal digestibility of CP in SBM differed between the direct and indirect methods; however, corresponding digestibility did not differ for corn. Additionally, the predicted and measured digestibility of both AID and SID differed in diets 2 and 3, implying that the digestibility values obtained from diets 1 and 5 were not additive for mixed diets. In conclusion, this study showed that digestibility evaluated by direct and indirect methods depends on the ingredients having different CP concentrations, and this finding may be considered to improve the accuracy of feed formulation for broiler chickens.