• Title/Summary/Keyword: communication cable

Search Result 439, Processing Time 0.035 seconds

A Development and Performance Assessment of On-Line Monitoring System for Optical Fiber Composite Underground Distribution Network using DTS (DTS를 활용한 광복합 지중 배전계통 실시간 감시시스템 개발 및 성능평가)

  • Cho, Jin-Tae;Kim, Ju-Yong;Lee, Hak-Ju;Cho, Hwi-Chang;Choi, Myeong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • Intelligent distribution equipment is inevitable to realize self-healing which is one of smart grid functions in distribution network. Therefore, most of distribution equipment have been developed with self diagnostic sensors. However, it is not effective to construct on-line monitoring system for underground distribution cable because of high cost and low sensitivity. Recently, optical fiber composite cable is being considered for communication and power delivery in order to cope with increasing communication in distribution network. This paper presents the design and performance assessment results of underground cable on-line monitoring system using DTS(Distributed Temperature Sensing) and optical fiber composite underground cable.

Measurement of Screening Effect by Metal Pipe on Induced Voltage to Communication Cable from Electric Railway (전기철도에서의 통신선 유도전압에 대한 금속관 차폐효과 측정)

  • Seol, Il-Hwan;Choi, Kyu-Hyoung;Lee, Sang-Mu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2355-2362
    • /
    • 2014
  • Electric railway induces interference voltage on wayside communication cable which brings about communication errors, malfunction of devices, and safety problem. The magnitude of the induced voltage depends on the electromagnetic field coupling which is affected by metallic installations such as rail and track structures. This paper provides an experimental analysis of the screening effect of metallic pipe on the inductive voltage caused on communication cable. The measurements at a high-speed rail site show that the screening effect of metallic pipe is about 20% when the separation distance between the pipe and communication cable is 1~2 m. The screening effects is less than 1% and can be neglected when the separation distance is more than 4 m. These results are useful to evaluate the screening effects of the metallic installations such as water pipe, gas pipe, and reinforcing bar.

The experimental investigation on the characteristics of the cabling tension (케이블 포설장력 특성에 대한 실험적 고찰)

  • Kim, Dong-Hun;Han, Jin-Woo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.49-53
    • /
    • 2009
  • If you are installing communications cables in the pipeline based on the kind of cable installation tension within the allowed range of the tension must be maintained. The tension of the installation affected by the cable types, cable jacketed status, cross-sectional shape of the pipeline, the substance present in the pipeline, pipeline linear, the direction of the cable is installed. Depending on the size of the cable installation tension fatal influence on the quality of communication, or, at worst, the cable can be cut. In this paper, test bed for building a pipeline and using optical cable and such cable tension was measured. Freedom of access to the pipeline used in the experiment, and installed in conjunction with the cable tension was measured. It possible for the cable installation to determine whether a duplicate, and have compared the actual measured tension value and the theoretical expression.

  • PDF

A Study of Properties Eddy Current Sensor for 22.9kv Distribution Insulation Cable (22.9kV 배전선로 절연전선 검출용 와류탐상 센서 특성 연구)

  • Oh, Yong-Cheul;Kim, Tag-Yong;Lee, Kyeong-Seob;Jeong, Han-Seok;Yoo, Jae-Sik;Yang, Jung-Kwon;Lee, Jae-Bong;Lee, Keon-Hang;Kim, Chong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2140_2141
    • /
    • 2009
  • We used the eddy current sensor for a 22.9kV distribution power line insulation cable diagnosis. The insulation cable which is used in the 22.9kV distribution power line is having element wire from 6 to 18. Consequently, currently to ECT applications it has a limit in the distribution power line. We about under producing to apply in pick-up coil forms and the differential total coil form where becomes sum of zero in order to have. From measurement result, partial broken cable was confirmed 500 mV~980 mV changes from normal state.

  • PDF

Implementation of Communication to Flexibly Configure the Number of Railway Cars (철도차량 수를 유연하게 구성할 수 있는 통신시스템 구현)

  • Yeon, Jun Sang;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.61-66
    • /
    • 2016
  • This paper presents the implementation for a network structure of railway cars using a point to point communication. Most of network's representative specifications for a train are the FIP (Field Bus), MVB (Multifunction Vehicle Bus), CAN and WTB (Wire Train Bus) which is used by ALSOM, SIEMENS and BOMBADIER as major in this field. These networks in a physical layer use a multi-drop method, connected from $1^{st}$ car to $n^{th}$ car of a train through a cable without any extra services such as an electric part, amplifier. However waveforms which is passed through a long cable in the multi-drop are distorted by a capacitance or resistance of the cable or environments. Also since using a cable connected directly from $1^{st}$ car to $n^{th}$ car, if over two trains make double head, it isn't easy to distinguish ID for each railway cars. So by using the point to point network per each car, it is able to reduce a distortion. Also since reducing distortion, this communication speed can be been higher and transmit and receive any packets more stably. Using proposed token in a packet, this can make ID per each railway car automatically. Finally experimental results show the good performance and effectiveness of the proposed method.

The study for image transmission method using communication equipment of KNR (철도연변의 통신설비를 이용한 화상전송방안에 관한 연구)

  • Cho, B.K.;Chang, S.G.;Ryu, S.H.;Kim, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.429-431
    • /
    • 2003
  • CCTV network has been implemented to transmit the image information of platform, ticket gate and transfer section to local headquarters in the KNR(Korean National Railroad). But, communication system for transferring image information around accident field or wayside has not been established ret. thus, at Present implementation of communication equipment is necessary for dynamic image of unspecified accident to be transmitted to headquarters. Copper cable communication network is run by KNR, but it is processing installation of optical cable in connection with the implemental plan for high-speed network from now on. And, the capacity of communication channel will be guaranteed much more than now between station and station. station and central headquarters when optical cable is completed. This study analyzes the image equipment of field for transmission and estimated matters to transmit image information of accident field to headquarters with using communication infrastructure. And, the study considers implemental method of communication network for long-distance image transmission from dozens to hundreds kilometers.

  • PDF

Trend of Industry and Standard related to Offshore Cable for Offshore Wind Farm (해상풍력용 해저케이블 산업 및 기술기준 동향)

  • Kim, Kyung-Hwa;Song, Yong-Un;Kim, Mi-Young;Kim, Mann-Eung
    • Journal of Wind Energy
    • /
    • v.3 no.2
    • /
    • pp.11-17
    • /
    • 2012
  • An offshore(submarine) cable has been used for more than a century, however it has been used mainly for communication or power supply to near-shore island. Therefore, offshore cable has not been got more attention than other types of cable and the related standards have also not been established well. However wind farms have been shifting from land to offshore because of better wind condition. Consequently, it has been pushing up demand for offshore cable. Hence, this paper introduces the trend of offshore cable industry and related standards or recommendations only focusing on offshore wind farm. In details, the installed offshore cables in offshore wind farms, the main offshore cable makers and up to date technologies are covered. In addition, the related standards or recommendations are also analyzed and compared each other.

Impact of Pay TV Market Structure and Competition on Digital Switch Over of Cable TV (유료방송의 시장구조와 경쟁이 케이블 TV의 디지털 전환에 미치는 영향)

  • Do, Joonho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.145-153
    • /
    • 2016
  • Cable TV with largest subscription base in pay TV market has difficulty in managing the task of digital switch over. This study analyzed the factors in delay of cable TV switch over and examined the impact of pay TV market structure and competition. The delaying factors turned out to be the lack of incentives and resources of cable TV operators, insufficient policy measures and acceptance tolerance issues of subscribers. Since cable TV operators with monopolistic status in pay TV market had continuous profit from analog service, they were not responsive to digital switch over which requires additional investment. Policy measures including support for the low income household and mandatory cut-off point for stopping analog broadcasting. Subscriber's willingness to accept digital broadcasting in terms of price sensitivity and preference for convenient operation also played a role. Introduction of IPTV in pay TV market influenced the speed of digital switch over of cable TV operators. MSOs with economies of scale showed higher digital switch over rate than independent SO.

On the Restriction of Cable TV Local Channel's News Commentary Function (케이블TV 지역채널의 해설.논평 금지에 관한 일 고찰)

  • Shin, Tae-Sub;Kim, Jae-Young
    • Korean journal of communication and information
    • /
    • v.56
    • /
    • pp.117-131
    • /
    • 2011
  • This study critically reviews the justifications for the restriction of cable local channel's news commentary function in terms of the fundamental principle of journalism. By doing so, it tries to find some problems and ways to solve them. Broadcasting Law and Korea Communications Commission's Rule inhibiting the news commentary of cable local channel on specific issues conflict with the basis of journalism which is particularly represented in Broadcasting Law. The law and rule tend to solidify public opinion for vested rights of local worthies. In addition, they are likely to degenerate cable local channel to the tools for promoting local government. Therefore, this article proposes the revision of the law and rule towards permitting the news commentary of cable local channel. At the same time, it suggests a new broadcasting policy for inducing cable local channel to increase manpower resources and production investment.

  • PDF

Development of Cable Management System for Ship (선박 전선 관리 시스템 개발)

  • Lee, Jae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.1987-1992
    • /
    • 2008
  • In recent years, the shape of ship building have been advanced. Thus the system is complex and cable is much used in ship. In this paper, Dijkstra algorithm is used to solve the shortest path of cable laying. Cable laying is given much weight in fable management system of ship. The developed cable management system is cut down on expenses and is improve the operation efficiency for ship building. Therefore, the developed cable management system can be used a support system in order to achieve a management target of company.