• 제목/요약/키워드: commercial power

검색결과 2,029건 처리시간 0.031초

저압계통 보호 엔지니어링을 위한 시각화 소프트웨어 개발 (A Development of Visualization Software for Protective Engineering in Low-Voltage Power Systems)

  • 윤상윤;이남호;이욱화;이진;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권7호
    • /
    • pp.297-305
    • /
    • 2006
  • This paper summarizes a development of visualization software for protective engineering in low-voltage power systems. The study is concentrated on the following aspects. First, a software engineering method is applied for designing the object-oriented program. The design and implementation of a Graphic User Interface(GUI) and its integration to a power system framework are developed using object-oriented programming(OOP) in Visual C++. Second, we develop the short circuit analysis module that oriented a low-voltage power system. It is possible to calculate a peak, symmetrical RMS, DC component and asymmetrical fault currents for each time. And it is the first software that can calculate the fault current for single branch of three-phase system. The calculation accuracy is compared with commercial software, and the libraries of low-voltage components are served for convenience use. Third, protective engineering functions are equipped. It is possible to automatically select the circuit breaker which based on the user input characteristics and the fault current calculation and examine the protective coordination. Through the case study, we verified that the developed software can be effectively used to examine the protective engineering in low-voltage power systems.

도심 고층건물 지붕에서의 소형 풍력발전기 발전량 예측 (Estimation of wind power generation of micro wind turbine on the roof of high rise buildings in urban area)

  • 최형식;장호남
    • 신재생에너지
    • /
    • 제5권4호
    • /
    • pp.21-27
    • /
    • 2009
  • Potential yield of micro wind turbine on the roof of urban high rise buildings is estimated. Urban wind profile is modeled as logarithmic profile above the mean building height with roughness length 0.8, displacement 7.5 m. Mean wind velocity from the meteorological agency data at the hight of 50m is used. Wind velocity changes are simulated on the rectangular roof of 26, 45, 53 degree pitch and the circular roof by computational fluid dynamics and RNG k-$\varepsilon$ turbulence models. Wind velocity increased approximately by a factor of the order of 270 % on the 26 degree pitched roof. In the 100 m and 200 m high buildings, wind enhancement is greater at the front side than at the center of the building. In the building arrangement model wind velocity changes abruptly and it becomes wind gusts. When commercial wind turbines are installed on the building roof, average power and annual power generation enhanced by 3~4 times than normal wind velocity at 50m and 6 kw wind turbine can generate 1053 kwh per month on the 26 degree pitched roof at 50m height and sufficiently supply electrical power with 15 household for common electrical use and food waste disposer. However, power output will vary significantly by the wind conditions in the order of $\pm$ 20 %.

  • PDF

원격검침을 위한 저 전력 무선 디지털 수도계량기 (Wireless Digital Water Meter with Low Power Consumption for Automatic Meter Reading)

  • 이영우;오승엽
    • 한국정보통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.963-970
    • /
    • 2008
  • RFID/USN 기술을 이용하여 각종 계량기를 원격으로 검침하려는 시도가 계속되고 있다. 수도 검침의 경우 아직 무선으로 원격 검침하는 체계가 발표되었거나 상용화되지 못하였다. 본 논문에서는 원격검침을 위한 디지털 수도 계량기의 설계 및 구현을 기술한다. 자기장을 감지하는 홀 센서를 사용하여 검침하고 그 결과를 ZigBee 무선으로 게이트웨이에 전송한다. 배터리만으로 계량기의 내구연한을 견뎌야 하므로 저전력 설계가 필수적이다. 구현된 계량기의 전력 소모량을 분석하여 3V, 3000mAh 용량 배터리, 2개로 8년의 내구연한을 견딜 수 있음을 보였다.

Remaining and emerging issues pertaining to the human reliability analysis of domestic nuclear power plants

  • Park, Jinkyun;Jeon, Hojun;Kim, Jaewhan;Kim, Namcheol;Park, Seong Kyu;Lee, Seungwoo;Lee, Yong Suk
    • Nuclear Engineering and Technology
    • /
    • 제51권5호
    • /
    • pp.1297-1306
    • /
    • 2019
  • Probabilistic safety assessments (PSA) have been used for several decades to visualize the risk level of commercial nuclear power plants (NPPs). Since the role of a human reliability analysis (HRA) is to provide human error probabilities for safety critical tasks to support PSA, PSA quality is strongly affected by HRA quality. Therefore, it is important to understand the underlying limitations or problems of HRA techniques. For this reason, this study conducted a survey among 14 subject matter experts who represent the HRA community of domestic Korean NPPs. As a result, five significant HRA issues were identified: (1) providing a technical basis for the K-HRA (Korean HRA) method, and developing dedicated HRA methods applicable to (2) diverse external events to support Level 1 PSA, (3) digital environments, (4) mobile equipment, and (5) severe accident management guideline tasks to support Level 2 PSA. In addition, an HRA method to support multi-unit PSA was emphasized because it plays an important role in the evaluation of site risk, which is one of the hottest current issues. It is believed that creating such a catalog of prioritized issues will be a good indication of research direction to improve HRA and therefore PSA quality.

A study on characteristics and internal exposure evaluation of radioactive aerosols during pipe cutting in decommissioning of nuclear power plant

  • Kim, Sun Il;Lee, Hak Yun;Song, Jong Soon
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1088-1098
    • /
    • 2018
  • Kori unit #1, which is the first commercial nuclear power plant in Korea, was permanently shutdown in June 2017, and it is about to be decommissioned. Currently in Korea, researches on the decommissioning technology are actively conducted, but there are few researches on workers internal exposure to radioactive aerosol that is generated in the process of decommissioning nuclear power plants. As a result, the over-exposure of decommissioning workers is feared, and the optimal working time needs to be revised in consideration of radioactive aerosol. This study investigated the annual exposure limits of various countries, which can be used as an indicator in evaluating workers' internal exposure to radioactive aerosol during pipe cutting in the process of decommissioning nuclear power plants, and the growth and dynamics of aerosol. Also, to evaluate it, the authors compared/analyzed the cases of aerosol generated when activated pipes are cut in the process of nuclear power plants and the codes for evaluating internal exposure. The evaluation codes and analyzed data conform to ALARA, and they are believed to be used as an important indicator in deriving an optimal working time that does not excess the annual exposure limit.

원격 전력제어 및 대기전력 관리 기능을 갖는 새로운 스마트 스위치 설계 (Design of New Smart Switch with Remote Power Control and Standby Power Management Function)

  • 이용안;김강철;한석붕
    • 한국정보통신학회논문지
    • /
    • 제14권10호
    • /
    • pp.2343-2350
    • /
    • 2010
  • 본 논문에서는 내장형 웹서버를 구현하여 원격지에서 실시간으로 소비전력 및 대기전력을 감시하고 제어할 수 있는 새로운 스마트 스위치를 제안하였다. 제안한 스위치는 상용화된 스마트 미터 제품과 같이 전력을 측정하고, 유. 무선 통신을 통하여 원격지에서 실시간으로 소비전력을 모니터링하고 각 스위치를 온/오프 할 수 있다. 또한, 기존의 절전형 콘덴서와 멀티 탭의 기능인 대기전력, 과전류 및 과부하에 대한 자동 차단 기능을 모두 갖는다. 본 논문에서 설계한 스마트 스위치는 원격 제어 및 모니터링을 위하여 PC를 이용하지 않고 전용의 내장형 웹서버를 구현함으로서 기존의 제품들보다 하드웨어 및 전력소비가 적으며 소형화된 단일제품으로 상용화가 가능하다.

소방 방재설비용 연료전지 발전시스템의 비절연형 고효율 전력변환기 설계 (High Efficiency Power Conversion System of Non Isolated Type Applied in Fuel Cell Generator Used to Fire Prevention Installation)

  • 곽동걸
    • 마이크로전자및패키징학회지
    • /
    • 제13권3호
    • /
    • pp.19-26
    • /
    • 2006
  • 본 논문은 예비 전력공급설비의 일환으로 비상시 소방 방재설비에 적용되는 연료전지 발전시스템에 대해 연구된다. 제안된 시스템은 비상시 상용 전력공급의 차단에 대비하여 소방 방재설비들의 전력공급원으로 이용된다. 연료전지 발전시스템에서 가장 손실이 큰 부분은 전력변환부이다. 또한 전력변환부의 손실은 전력변환을 위해 사용된 전력용 반도체 스위치의 스위칭 손실로 주어진다. 본 논문에서는 이러한 연료전지 발전시스템의 출력을 최대한 활용하기 위하여 부분공진의 기법이 적용된 고효율의 전력변환기가 제안된다. 또한 연료전지 발전시스템에 적용된 고효율 전력변환기는 비절연형으로 설계되고 사용된 제어스위치들은 새로운 소프트 스위칭 회로토폴로지에 의해 무손실로 동작되어 시스템의 효율을 증대시킨다. 다양한 컴퓨터 시뮬레이션과 특성실험을 통해 이론적 해석의 타당성이 입증된다.

  • PDF

IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템 (Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010)

  • 전정채;오훈
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3100-3106
    • /
    • 2014
  • 본 논문에서는 전력 시스템의 전원 및 부하 측을 동시에 감시가 가능한 다 채널(전압 8채널, 전류 10채널) 전력 측정 시스템을 개발하였다. 제안된 시스템은 전력품질과 관련된 규정인 IEEE 1459-2010의 정의를 사용하여 전력 성분을 계산하는 신호처리 알고리즘을 기반으로 TMS320C42 DSP를 이용하여 개발하였다. 개발된 시스템은 표준 전원 공급 장치를 이용하여 그 성능 시험을 실시하였고, 그 결과 측정오차는 0.2% 이하로 나타났다. 또한 제안된 시스템을 3상 4선식 전력시스템에 설치하여 실증 시험을 실시하여 그 성능을 입증하였다. 제안된 시스템은 상업 및 산업용 전력 시스템에 적용하여 동시에 다 채널로 전력을 측정 및 분석함으로써 전력품질과 관련된 다양한 문제를 줄일 수 있을 것이다.

슈퍼캐패시터와 가변속 엔진발전기를 이용한 독립형 전원 시스템 (An Isolated Power System Based on Variable Speed Engine Generator with Super-capacitor)

  • 이준환;이승환;설승기
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.128-134
    • /
    • 2008
  • 독립형 전원시스템에서 엔진을 이용한 발전시스템은 지금까지 에너지의 효율적인 측면보다는 설치 단가 및 신뢰성이 중요한 이슈가 되어왔으나, 최근 들어 신뢰성과 함께 에너지의 효율적 사용, 대기 환경 개선 및 발전 전력 품질 등이 점차 중요시 되어가고 있다. 가변속 엔진 발전 시스템의 경우 출력 전력에 대응하여 엔진 속도를 가변함으로써, 경부하시 획기적인 효율 개선이 가능하다. 또한 부하 전압, 주파수는 출력 인버터에 의해 제어되므로, 그 응답 속도가 빨라 고 품질의 전력을 전원에 공급할 수 있다. 특히 급격한 부하 증가 시 엔진 출력이 늘어나는 시간동안 부족한 전력을 슈퍼캐패시터로부터 공급받음으로써, 부하 급증 시에도 안정된 전력 공급이 가능하다. 본 논문에서는 소형 디젤 엔진과 슈퍼캐패시터를 이용한 가변속 엔진 발전 시스템의 개념을 설명하고, 가변속 운전의 필요성, 고정 운전속 대비 연비 절감 및 3상 4선식 인버터를 사용한 고품질의 전력 공급 등의 타당성을 모의 실험과 실험을 통하여 검증하도록 한다.

View Factor를 고려한 마이크로그리드 적용용 고효율 P-Type Si 양면형 태양광 모듈의 출력량 예측 (Power Prediction of P-Type Si Bifacial PV Module Using View Factor for the Application to Microgrid Network)

  • 최진호;김광순;차혜림;김규광;방병관;박소영;안형근
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.182-187
    • /
    • 2018
  • In this study, 20.8% of a p-type Si bifacial solar cell was used to develop a photovoltaic (PV) module to obtain the maximum power under a limited installation area. The transparent back sheet material was replaced during fabrication with a white one, which is opaque in commercial products. This is very beneficial for the generation of more electricity, owing to the additional power generation via absorption of light from the rear side. A new model is suggested herein to predict the power of the bifacial PV module by considering the backside reflections from the roof and/or environment. This model considers not only the frontside reflection, but also the nonuniformity of the backside light sources. Theoretical predictions were compared to experimental data to prove the validity of this model, the error range for which ranged from 0.32% to 8.49%. Especially, under $700W/m^2$, the error rate was as low as 2.25%. This work could provide theoretical and experimental bases for application to a distributed and microgrid network.