• 제목/요약/키워드: commercial power

검색결과 2,023건 처리시간 0.025초

An Effective Viewport Resolution Scaling Technique to Reduce the Power Consumption in Mobile GPUs

  • Hwang, Imjae;Kwon, Hyuck-Joo;Chang, Ji-Hye;Lim, Yeongkyu;Kim, Cheong Ghil;Park, Woo-Chan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권8호
    • /
    • pp.3918-3934
    • /
    • 2017
  • This paper presents a viewport resolution scaling technique to reduce power consumption in mobile graphic processing units (GPUs). This technique controls the rendering resolution of applications in proportion to the resolution factor. In the mobile environment, it is essential to find an effective resolution factor to achieve low power consumption because both the resolution and power consumption of a GPU are in mutual trade-off. This paper presents a resolution factor that can minimize image quality degradation and gain power reduction. For this purpose, software and hardware viewport resolution scaling techniques are applied in the Android environment. Then, the correlation between image quality and power consumption is analyzed according to the resolution factor by conducting a benchmark analysis in the real commercial environment. Experimental results show that the power consumption decreased by 36.96% on average by the hardware viewport resolution scaling technique.

고유진동수 기반 석션기초의 지반구속효과 분석 (Confinement Effect Analysis Of Suction Pile In Ground Soil On The Basis Of Natural Frequency Measurement)

  • 유무성;이준신;이종화;서윤호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.31-36
    • /
    • 2022
  • This paper presents the measuring process of dynamic properties of offshore wind power foundation and provides consideration of each step. This Guideline enables to maintain consistent measuring procedure and therefore increase the reliability of test results. Small scaled suction bucket foundation was fabricated to represent the commercial support structure installation mechanism and two cases(free-free, free-fixed) of dynamic tests were performed at workshop. From the tests, the importance of dynamic properties of connection part between suction bucket and tower was figured out. More over, types and configuration of measuring devices are recommended which can help find the natural frequency of wind turbine foundation correctly. In field test, it was found that the natural frequency of suction bucket foundation was increased linearly with the penetration depth due to the confining effect of ambient soil. Meanwhile, it was not easy to get an enough excitation force with normal impact hammer because the N.F of suction bucket model was in the lower range of 0 Hz ~ 5 Hz. Therefore, new excitation method which has enough force and can excite lower frequency range was devised. This study will help develop safety check procedure of suction bucket foundation in field at each installation stage using the N.F measurement.

상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • 제24권1호
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

A Study on the Design of a Planar Loop Sensor for Partial Discharge Diagnosis of 22.9 kV XLPE Power Cables

  • Lim, Kwang-Jin;Yang, Sang-Hyun;Shin, Dong-Hoon;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권4호
    • /
    • pp.559-565
    • /
    • 2008
  • This study designed a new type of loop antenna that is able to detect partial discharges based on microstrip line technology. In the diagnosis of power cables, partial discharge signals are generally produced at a frequency range less than 100MHz because high frequency PD signals are lost along a propagation path in such cables. The new type of loop antenna sensor has been studied using simulation software known as CST microwave studio version 5.0. In partial discharge measurement experiments, a commercial HFCT sensor was used as a reference sensor. Several experiments were made over HFCT and loop antenna sensors for detecting partial discharges on 22.9kV MV XLPE cable. In this study, we showed the loop antenna designed in this study that can be applied as a commercial HFCT sensor.

냉각시스템에 의한 태양광 발전의 효율 개선 (Solar Photovoltaic According to Installation of Cooling System)

  • 염성배;최홍규;최영준;홍성구;김태훈
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.66-71
    • /
    • 2009
  • 태양광 발전은 일사량이 높을수록 발전량이 증가된다. 그러나 일사량이 높아짐에 따라 셀의 온도도 같이 증가해 발전 효율은 감소하게 된다. 냉각시스템의 설치는 이러한 문제점을 해결하기 위한 적절한 방법이 될 수 있으나 냉각시스템 설치 후 태양광 발전량의 증가량, 냉각시스템의 설치비용, 냉각시스템의 유지 보수비용 등 실용화에 필요한 내용은 논의되고 있지 않다. 따라서 본 논문에서는 냉각시스템의 효과 및 상용화 가능성에 대해 기술하였다. 실험결과 냉각시스템 설치 후, 연평균 약 5.76[%]의 발전량 증가를 기대할 수 있다.

유압시스템의 궤적 추종 시뮬레이션 모델 개발 (Development of Simulation Model for Trajectory Tracking on Hydraulic System)

  • 최종환
    • 한국금형공학회:학술대회논문집
    • /
    • 한국금형공학회 2008년도 하계 학술대회
    • /
    • pp.61-66
    • /
    • 2008
  • The hydraulic system have been used much in a heavy machine which high power source is desired. In the case of the heavy press machine and the injection molding machine, the use of the hydraulic power is essential especially for increasing productivity and getting the good products. Because the hydraulic circuit is very complex and the system parameters are uncertain, the development of the simulation model for hydraulic system is not easy in the heavy machine. In this case, Many researchers have used a commercial program for analysis and development in a major field of study. In this paper, the aim is to develop the simulation model of the hydraulic system with various commercial program for trajectory tracking. And adaptive control method is applied to the simulation model for the trajectory tracking of a cylinder motion. Load on the cylinder is modeled in ADAMS program, the hydraulic circuit including pump, spool valve and cylinder is modeled in AMESim program and a controller is designed in MatLab/simulink program. The suggested model is applied for the tracking of a cylinder motion, and through computer simulation, its trajectory tracking performance is illustrated.

  • PDF

Low GWP 냉매를 적용한 해수열 히트펌프의 성능해석 (The Performance Analysis of Sea Water Heat Pump applied Low GWP Refrigerants)

  • 임승택;김현주;이호생
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.92-97
    • /
    • 2016
  • In this study, the seawater Heat Pump System using seawater with temperature of annual domestic conditions ($0^{\circ}C$ to $25^{\circ}C$) is designed in order to compare its performance against the Heat Pump using unused heat of seawater. As a potential replacement for current refrigerants that exacerbate global warming and ozone delpetion, a Low GWP refrigerant's performance is analyzed. The basic water to water Heat Pump system is chosen and three commercial refrigerants - R134a, R410a, R32 - are used to compare against new Low GWP refrigerant R1234ze. When seawater with temperature of $25^{\circ}C$ is used, the performance change showed maximal increase in COP, 38.3%. low GWP refrigerant R1234ze, showed great performance characteristics reach to 5.242 and Existing commercial refrigerant, R134a showed only less than 0.03 performance difference against R1234ze. The study confirms notable performance of R1234ze refrigerant through simulation as environmentally friendly refrigerant for domestic seawater Heat Pump.

소리쟁이 뿌리 열수 추출물의 폴리페놀 함량 및 추출물의 항산화 효과 (Polyphenol Contents of Rumex crispus Root Extract with Hot Water and its Antioxidative Effect)

  • 윤영심;정갑섭
    • 한국환경과학회지
    • /
    • 제21권10호
    • /
    • pp.1265-1274
    • /
    • 2012
  • This study was conducted to investigate the extraction characteristics including total polyphenol compound content (TPC) and the antioxidative effect of Rumex crispus root extract on commercial corn oil. Extraction yield was increased with extraction temperature but decreased with extraction ratio. No significant differences in aromatics content were found among the extracts prepared with various extraction conditions; extraction ratio, extraction temperature, extraction pH and composition of extractant. Total flavonoid content of the extract was increased with extraction temperature and extraction pH, and highest value of it was found when extractant composition of ethanol in water was 75%. Total polyphenol compound content (TPC) of the extract with 10 fold extraction ratio showed the highest value, but no significant difference in TPC was found with extraction temperature. Reducing power and DPPH (${\alpha}$,${\alpha}$-diphenyl-${\beta}$-picrylhydrazyl) radical scavenging ability (RSA) of the extract in spectrophotometric absorbance were decreased with extraction ratio but increased with extraction temperature and showed 63.1%~98.4% and 67.6%~86.7% of those of ascorbic acid in reducing power and DPPH RSA, respectively. The antioxidative effects of the extract on corn oil were 84.8~93.0% of that of commercial butylated hydroxytoluene, the antioxidant index value was highest when the ethanol composition to water in extractant was equal ratio.

냉각시스템 설치에 따른 태양광 발전 (Solar photovoltaic according to installation of cooling system)

  • 홍성구;최홍규;유해출;이찬재;한상권;김태훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.189-192
    • /
    • 2008
  • 태양광 발전은 일사량이 높을수록 발전량이 증가된다. 그러나 일사량이 높아짐에 따라 셀의 온도도 같이 증가해 발전 효율은 감소하게 된다. 냉각시스템의 설치는 이러한 문제점을 해결하기 위한 적절한 방법이 될 수 있으나 냉각시스템 설치 후 태양광 발전량의 증가량, 냉각시스템의 설치비용, 냉각시스템의 유지 보수비용 등 실용화에 필요한 내용은 논의되고 있지 않다. 따라서 본 논문에서는 냉각시스템의 효과 및 상용화 가능성에 대해 기술하였다.

  • PDF

상용 CFD코드를 이용한 입형 다단 원심펌프 성능해석 (Performance Analysis of the Vertical Multi-stage Centrifugal Pump using Commercial CFD Code)

  • 모장오;강신정;송근택;남청도;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 추계 학술대회논문집
    • /
    • pp.150-155
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is not only to confirm how much the effect of three kinds of blade inlet breadth (11mm, 11.5mm, 12mm) of impeller has influence on the performance of vertical multi-stage pump but also to make clear the cause about performance difference at the exit side of impeller and guide vane. The vertical multi-stage pump consisit of the impeller, guide, vane and cylinder. The grid of numerical analysis used to the vertical multi-stage pump is 18,000, 45,000, and 100000 cells in case of the impeller, guide vane, cylinder and total grid is 730,000 cells. The characteristics such as total pressure coefficient, total head, shaft horse power, power efficiency at the exit side of impeller and guide vane, discharge coefficient are represented according to flow rage changing.

  • PDF