• Title/Summary/Keyword: combustion method

Search Result 1,732, Processing Time 0.034 seconds

A Study on the Basic Investigation for the Fire Risk Assessment of Education Facilities (교육시설 화재위험성 평가를 위한 기초조사에 관한 연구)

  • Lee, Sung-Il;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.351-364
    • /
    • 2021
  • Purpose: Fire load analysis was conducted to secure basic data for evaluating fire risk of educational facilities. In order to calculate the fire load through a preliminary survey, basic data related to the fire load of school facilities were collected. Method: The basic data were the definition and types of fire loads, combustion heat data for the calculation of fire loads. The fire load was evaluated by multiplying the combustion heat by the weight of the combustibles in the compartment when calculating the fire load. Result: As for the fixed combustible materials of A-elementary school, the floor was mainly made of wood, in consideration of emotion and safety in the classroom, music room, and school office, and the rest of the compartments were made of stone. The ceiling and walls were made of gypsum board and concrete, so they were not combustible. The typical inflammable items in each room were desks, chairs, and lockers in the classroom, and the laboratory equipment box and experimental tool box were the main components in the science room, and books, bookshelves, and reading equipment occupied a large proportion in the library room. Conclusion: 'The fire loads of A-elementary' schools according to the combustibles loaded were in the order of library, computer room, English learning room, teacher's office, general classroom, science hall, and music room.

Risk Assessment of Smoke Generated During Combustion for Some Wood (일부 목재의 연소 시 발생되는 연기의 위험성 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.33 no.4
    • /
    • pp.373-380
    • /
    • 2022
  • In this study, Chung's equations 1, 2, and 3 were extended to standardize smoke safety rating evaluation in case of fire, and Chung's equations-V, smoke performance index-V, and smoke growth index-V were calculated. Five types of wood were selected and their smoke indices were measured using the cone calorimeter method according to ISO 5660-1. The smoke risk was graded by the smoke risk index-VI according to Chung's equation-VI. Smoke risk index-VI increased in the order of PMMA (1) ≈ maple (1.01) < ash (1.57) < needle fir (4.98) < paulownia (46.15) < western red cedar (106.26). It was predicted that maple and ash had the lowest smoke risk, and paulownia and western red cedar had the highest. The five samples' CO mean production rate (COPmean) was 0.0009~0.0024 g/s, indicating that these woods were incompletely burned than the polymethyl methacrylate (PMMA) reference material. Regarding the smoke properties of the chosen woods, the smoke performance index-V (SPI-V) increased as the bulk density increased, and the smoke risk index-VI (SRI-VI) decreased.

International Comparison of Decoupling of Greenhouse Gas Emissions in the Steel Industry (철강산업의 온실가스 배출 탈동조화 국제비교)

  • Kim, Dong Koo
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.113-139
    • /
    • 2022
  • The iron and steel industry is a manufacturing industry with the largest greenhouse gases emissions and has a great ripple effect on the national economy as a core material industry. This study internationally compared the decoupling patterns of greenhouse gases emissions in the iron and steel industry from 1990 to 2019, focusing on Korea, Japan, and Germany. In particular, unlike previous studies that considered only fuel combustion emissions, this study considered all fuel combustion emissions, industrial process emissions, and indirect emissions from the use of electricity and heat. As a result of the analysis, Korea is interpreted as expansive coupling, Japan as decoupling, and Germany as unclear. Therefore, the decoupling path that the Korean iron and steel industry should take should not be in Germany, but in the form of seeking a decoupling method similar to Japan or more effective than Japan. In addition, this study considered the characteristics of the iron and steel industry as much as possible and presented the causes of the decoupling analysis results and implications for the Korean iron and steel industry through comparison with Japan and Germany. In particular, four factors were suggested as factors which has promoted decoupling in Japan: high value-added of Japanese iron and steel products, development of energy efficiency technology in the Japanese iron and steel industry, strategic M&A of the Japanese iron and steel industry, and maintaining competitiveness according to the closed distribution structure of Japanese iron and steel products. The Korean iron and steel industry should also use the case of Japan as a benchmark to further increase added value through quality uprade and product diversification of iron and steel products, while at the same time making efforts to fundamentally reduce greenhouse gas emissions through the development of new technologies.

Current status of brominated flame retardants (BFR) and polybrominated dibenzo-p-dioxins and furans (PBDDs/PBDFs) (브롬화난연제 및 브롬화다이옥신류의 연구동향)

  • Kwon, Myung-Hee;Song, Ki-Bong;Kang, Yung-Ryul;Hwang, Seung-Ryu;Shin, Sun Kyoung;Kim, Kum-Hee;Park, Jin Soo;Kim, Sue-Jin;Lee, Su-Yung;Kim, Dong-Hoon;Jung, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.443-458
    • /
    • 2008
  • Brominated flame retardants (BFRs) are chemical compounds that inhibit the combustion of organic materials by scavenging free radicals that would otherwise encourage the spread of flames. These compounds are found in a wide variety of materials including paints, plastics, textiles, furniture and electronics. Mounting evidence, however, suggests that the non-reactive BFRs can easily leach into the environment and pose significant environmental and health concerns. PBDDs/PBDFs are often formed in the process of manufacturing brominated flame retardants and from the combustion of waste products containing flame retardants BFR. Therefore, this paper describes the general characteristics, management status, residual concentration in environments and analytical method.

Analysis of Rollover Angle According to Arrangement of Main Parts of Electric Tractor Using Dynamic Simulation (시뮬레이션을 이용한 전기 트랙터 주요 부품 배치에 따른 전도각 분석)

  • Jin Ho Son;Yeong Su Kim;Yu Shin Ha
    • Journal of the Korea Society for Simulation
    • /
    • v.32 no.4
    • /
    • pp.77-84
    • /
    • 2023
  • In the agricultural sector, power sources are being developed that use alternative energy sources such as electric tractors and hydrogen tractors, away from internal combustion engine tractors. As parts such as engines and transmissions used in conventional internal combustion engine tractors are replaced with motors and batteries, the center of gravity changes, and thus the risk of rollover should be considered. The purpose of this study is to analyze the overturn angle of the main parts of the electric tractor through dynamic simulation to minimize the overturn accident and to derive the optimal arrangement of parts to improve stability. A total of nine dynamics simulations were conducted by designing three components of the PTO motor, drive motor and the battery pack, and three factors of the arrangement method. As a result of the experiment, it was confirmed that Type3 Level3, in which the drive motor and the PTO motor are located at the front and rear of the tractor, and two battery packs are located in the middle of the tractor, has a high rollover angle. As a result of this study, the stability increased as the center of gravity was placed backward and located below. Future research needs to be done to find the optimal location of parts considering their performance and placement efficiency.

A Study on Estimation of Air Pollutants Emission from Residential Wood Stove (주거용 화목난로의 대기오염 배출량 추정에 관한 연구)

  • Kim, Pil-Su;Jang, Young-Kee;Kim, Jeong;Shin, Yong-Il;Kim, Jeong-Soo;An, Jun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.3
    • /
    • pp.276-285
    • /
    • 2010
  • Recently the Korean government has tried to cut down the $PM_{10}$ concentration by the Special Law for Air Quality Improvement. But the concentrations of $PM_{10}$ have exceeded the air quality standard at most monitoring stations. Primary $PM_{10}$ emitted from various sources and emission data have large uncertainty. The biomass burning is one of the major sources of $PM_{10}$ emission. The biomass burning is composed of wood stove usage, meat cooking and agricultural combustion etc.. Activity data and emission factors for the biomass burning are limited, and it is hard to calculate the air pollution emissions from these sources. In this study, we tried to estimate the air pollution emission from residential wood stove usage. The number of total wood stoves is estimated by the survey of wood stove manufacturer. And air pollution emission factors for the wood stove are investigated using the flue gas measurement by U.S. EPA particulate test method (Method 5G). As the results, the $PM_{10}$ and CO emission factors of wood stove are estimated as 7.7 g/kg-wood and 78.8 g/kg-wood respectively. The annual $PM_{10}$ and CO emissions from wood stove are calculated as 1,200~3,600 ton/year and 12,600~36,400 ton/year in Korea. It is confirmed that wood stove is the one of major sources of biomass burning, and the survey for activity data and the measurement for emission factors are needed for reducing the uncertainty of these emission data.

Combustion and NOx Emission Characteristics of the Gas Turbine Combustor Burning Medium-Btu Gas as Alternative Fuel (중발열량 가스 대체 시 가스터빈 연소기의 연소 및 NOx 배출 특성)

  • Lee, Chan;Seo, Je-Young
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.320-327
    • /
    • 2003
  • A CFD (Computational fluid Dynamics) research is conducted for the investigation of the fuel alteration of MBTU (medium-Btu) gas in IGCC gas turbine combustor. The computational analysis method of the gas turbine combustor is constructed by incorporating MBTU gas reaction and fuel NOx models into commercial CFD code. With the use of the present analysis method, comparisons are made on the flow velocity, the chemical species and the temperature distributions, and on the flame shape and behavior of gas turbine combustor firing natural gas and MBTU gases (coal gas, heavy residue oil gas). Furthermore, the NOx formation characteristics and the turbine matching condition of the combustor are analyzed. Based on the computed analysis results, the present study provides the directions for the redesign and the design modification of IGCC gas turbine combustor firing MBTU gas as alternative fuel.

Comparative Smoke Analysis of CORESTA Monitoring Cigarettes (CORESTA 모니터링 담배의 비교 분석)

  • Lee, Seung-Yong;Ji, Sang-Un;Shin, Hea-Geun
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.33 no.1
    • /
    • pp.28-38
    • /
    • 2011
  • This experiment was conducted as a part of Asia collaborative study on purpose of verifying the difference between CM6 and CM7 including 3R4F for reference. It carried out using various analytical categories for example, main stream, sidestream and Av. smoke. Additional analysis such as physical properties, blending ratio, combustibility and general leaf component analysis also implemented in order to investigate the difference. We complied with ISO standard and CORESTA recommended method during analytical operating procedures. In this study, we described that comparative analytical result for CM6 and CM7 known as reference or monitoring cigarettes including 3R4F for reference. All sample cigarettes were conditioned at $22^{\circ}C$, 60% relative humidity for 48 hours. Av. Smoke, MS and SS smoke analysis were performed over five times with two smoking condition, ISO and Health Canada with the exception of Av. smoke analysis. We complied with ISO standard method during analytical operating procedures. And, we conducted additional analysis, such as physical properties, blending ratio, combustibility and leaf component analysis also in order to investigate the difference. In conclusion, we found out some differences between CORESTA monitoring cigarette No. 6 and No 7. The smoke components such as total particulate matters, NFDPM, nicotine and carbon monoxide contents of CM7 were a little lower than CM6. And, these phenomena were the same as not only main stream smoke but also side stream smoke and Av. smoke. This tendency was consistent with ISO and Health Canada smoking condition. Besides, leaf constituents' color of CM7 was darker than CM6. In case of combustibility, it showed short combustion time approximately 30 seconds.

Fabrication of $\textrm{ZrB}_2$ by SHS Process and Reaction-bonded $\textrm{ZrB}_2$-ZrC Composite (SHS법에 의한 $\textrm{ZrB}_2$ 합성과 반응소결된 $\textrm{ZrB}_2$-ZrC계 복합체의 제조)

  • Lee, Yun-Bok;Kim, Jeong-Seop;Kim, Sang-Bae;Park, Hong-Chae;O, Gi-Dong
    • Korean Journal of Materials Research
    • /
    • v.9 no.1
    • /
    • pp.8-13
    • /
    • 1999
  • $ZrB _2$ was prepared from a mixture of $ZrO_2$, $B_2$$O_3$and Mg by SHS method. The combustion products were successfully obtained from a mixture of $Zro_2$:$B_2$$O_3$:Mg=1:2.0:8.5(molar ratio). MgO, by-product, was removed to 92.7% by leaching with 1M HCl solution at 9$0^{\circ}C$, for 10 hours. After leaching, the mean particle size of the resultant $ZrB_2$powders was 23.6$\mu\textrm{m}$. $ZrB_2$-ZrC composite was suitably obtained from a mixture of C/Zr=1.2 molar ratio by arc-melting method. The density of arc-melted specimen increased by adding excess zirconium content(x). The bulk density was 6.17g/㎤ for x=0, and 6.37g/㎤ x=4. Vickers hardness of arc-melted specimen was /$1290kg\textrm{mm}^2$ for x=0, and fracture toughness increased to 4.2MPa.m\ulcornerforx=4 compared to 3.4MPa.m\ulcornerfor x=0.

  • PDF

A Study on a Comparison of Sky View Factors and a Correlation with Air Temperature in the City (하늘시계지수 비교 및 도시기온 상관성 연구: 강남 선정릉지역을 중심으로)

  • Yi, Chaeyeon;Shin, Yire;An, Seung Man
    • Atmosphere
    • /
    • v.27 no.4
    • /
    • pp.483-498
    • /
    • 2017
  • Sky view factor can quantify the influence of complex obstructions. This study aims to evaluate the best available SVF method that represents an urban thermal condition with land cover in complex city of Korea and also to quantify a correlation between SVF and mean air temperature; the results are as follows. First, three SVF methods comparison result shows that urban thermal study should consider forest canopy induced effects because the forest canopy test (on/off) on SVF reveals significant difference range (0.8, between maximum value and minimum value) in comparison with the range (0.1~0.3) of SVFs (Fisheye, SOLWEIG and 3DPC) difference. The significance is bigger as a forest cover proportion become larger. Second, R-square between SVF methods and urban local mean air temperature seems more reliable at night than a day. And as the value of SVF increased, it showed a positive slope in summer day and a negative slope in winter night. In the SVF calculation method, Fisheye SVF, which is the observed value, is close to the 3DPC SVF, but the grid-based SWG SVF is higher in correlation with the temperature. However, both urban climate monitoring and model/analysis study need more development because of the different between SVF and mean air temperature correlation results in the summer night period, which imply other major factors such as cooling air by the forest canopy, warming air by anthropogenic heat emitted from fuel oil combustion and so forth.