• 제목/요약/키워드: combined water

검색결과 1,893건 처리시간 0.027초

합류식 하수관거의 유출 특성 분석 조사 (Characteristics and Combined Sewer Overflows)

  • 안기선;장성용;권영호
    • 한국환경과학회지
    • /
    • 제19권6호
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.

A Post-Implementation Assessment of the Effectiveness of a Separate Sewer System in Improving River Water Quality

  • Reyes, Nash Jett;Geronimo, Franz Kevin;Guerra, Heidi;Choi, Hyeseon;Jeon, Minsu;Kim, Lee-Hyung;Ku, Jin Hye;Jun, Kyung Soo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.241-241
    • /
    • 2021
  • Recent developments recommend the use of SSS to prevent combined sewer overflows and reduce excessive pollutant deposition in the receiving waters; however, other studies also suggest that SSS have minimal or no advantage over CSS in terms of reducing the pollutant loads being discharged in natural waterways. This study was conducted to evaluate the effectiveness of employing SSS in improving the water quality of the rivers in Okcheon-gun, South Korea. The former combined sewer outfalls (CSOs) were monitored to determine the presence of illicit connections or leaks in the newly-established SSS. Dry and wet-day monitoring was conducted alongside the collection of water samples on 14 points along the reach of the rivers and four former CSOs to determine water quality changes and patterns of pollutant loading. Among the 34 former CSOs in the study area, eight former CSOs exhibited dry-day discharges, implying the possibility of having illicit connections, leaks, or illegal wastewater discharge in the system. Moreover, relatively high biochemical oxygen demand (BOD) chemical oxygen demand (COD) concentrations, ranging from 4.8 mg/L to 24.9 mg/L and 6.4 mg/L to 10.1 mg/L, respectively were observed on three out of the four monitored CSOs. Fluctuations in the pollutant concentrations in the different monitored points along the river was also observed due to the presence of pipes discharging polluted water. Ultimately, further studies are necessary to identify the sources of dry-day discharges in the CSOs to successfully improve the water quality of the rivers in the area.

  • PDF

Exhaust Gas Recirculation/Water Injection Experimental Results for NOx Emission Reduction in Diesel Engine

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권7호
    • /
    • pp.823-832
    • /
    • 2007
  • This paper presents the static characteristics of EGR-WI combined system. The water injection system was statically characterized by recording the engine exhaust outlet $NO_x$ emissions for comparison with baseline $NO_x$ emissions. Effects of the water injection system on CO and HC emissions and fuel consumption were examined. The research engine used for these experiments was a 103 kW turbocharged, intercooled, 2.5 L VM Motori CIDI engine equipped with a cooled EGR system. Water injection in the intake system demonstrated the potential for significant reductions in engine outlet $NO_x$ emissions. The system has reduced engine outlet $NO_x$ emissions by 40-50%, but caused significant increases in CO and HC emissions, particularly at low loads. Fuel consumption effects were minimal.

PREDICTION OF COMBINED SEWER OVERFLOWS CHARACTERIZED BY RUNOFF

  • Seo, Jeong-Mi;Cho, Yong-Kyun;Yu, Myong-Jin;Ahn, Seoung-Koo;Kim, Hyun-Ook
    • Environmental Engineering Research
    • /
    • 제10권2호
    • /
    • pp.62-70
    • /
    • 2005
  • Pollution loading of Combined Sewer Overflows (CSOs) is frequently over the capacity of a wastewater treatment plant (WWTP) receiving the water. The objectives of this study are to investigate water quality of CSOs in Anmyun-ueup, Tean province and to apply Storm Water Management Model to predict flow rate and water quality of the CSOs. The capacity of a local WWTP was also estimated according to rainfall duration and intensity. Eleven water quality parameters were analyzed to characterize overflows. SWMM model was applied to predict the flow rate and pollutant load of CSOs during rain event. Overall, profile of the flow and pollutant load predicted by the model well followed the observed data. Based on model prediction and observed data, CSOs frequently occurs in the study area, even with light precipitation or short rainfall duration. Model analysis also indicated that the local WWTP’s capacity was short to cover the CSOs.

정수처리를 위한 여과지의 역세척에 관한 연구 (A Study on Backwashing of Granular Fiters Used in Water Treatment)

  • 이정택;안종호;최근호
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Mechanical response of rockfills in a simulated true triaxial test: A combined FDEM study

  • Ma, Gang;Chang, Xiao-Lin;Zhou, Wei;Ng, Tang-Tat
    • Geomechanics and Engineering
    • /
    • 제7권3호
    • /
    • pp.317-333
    • /
    • 2014
  • The study of the mechanical behavior of rockfill materials under three-dimensional loading conditions is a current research focus area. This paper presents a microscale numerical study of rockfill deformation and strength characteristics using the Combined Finite-Discrete Element Method (FDEM). Two features unique to this study are the consideration of irregular particle shapes and particle crushability. A polydisperse assembly of irregular polyhedra was prepared to reproduce the mechanical behavior of rockfill materials subjected to axial compression at a constant mean stress for a range of intermediate principal stress ratios in the interval [0, 1]. The simulation results, including the stress-strain characteristics, relationship between principal strains, and principal deviator strains are discussed. The stress-dilatancy behavior is described using a linear dilatancy equation with its material constants varying with the intermediate principal stress ratio. The failure surface in the principal stress space and its traces in the deviatoric and meridian plane are also presented. The modified Lade-Duncan criterion most closely describes the stress points at failure.

섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계 (Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제24권11호
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.

물리·화학적 및 생물학적 처리가 결합된 장치형 하천정화 시스템에 관한 연구 (A Study on the Equipment Type of Stream Purification System that Applies Combined Physicochemical and Biological Treatment)

  • 엄한기;김성철;김성수;김삼주
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.273-281
    • /
    • 2017
  • The objective of this study is to evaluate the performance of stream purification equipment system combined MBP (Micro Bubble Process) and AGBP (Aerobic Granular Biofilm Process). Based on results, the optimal HRT (Hydraulic Retention Time) of MBP and AGBP set as 0.72 and 2.4 h, respectively. In the results of continuous operation on combined MBP and AGBP, it is possible to achieve a BOD, TSS and T-P removal efficiency of 85, 90 and 94%, respectively. It also confirmed that the water quality of the stream can be purified with increasing circulation flow through water simulation evaluation applied the QUAL-NIER model. Consequently this purification system can resolve the stream purification and dry stream problem.

동해와 염해를 동시에 받는 콘크리트의 복합열화에 관한 연구 (A Study on the Combined Deterioration of Concrete subjected to Freezing-Thawing and Chloride Attack)

  • 김은겸;최상덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.225-228
    • /
    • 2005
  • This paper was accomplished for analyzing the reason of the above deterioration happened on the deck of concrete bridge. The bridge was constructed at 660m above the sea level having more freezing and snowing days. Therefore, it is placed on the particular condition sprinkling $CaCl_2$ enough for keeping up with moderate traffic condition. When it is considered to the former condition, the bridge can be assumed to potentialities for combined deterioration with freezing-thawing under sprinkling deicing chemical. Core specimens were gathered from the concrete deck for clearing the reason of the above deterioration exactly, and it is used for various tests for measuring the compressive strength, elastic modulus, content of $Cl^-$, freezing-thawing at the fresh and salt water. As a result of freezing-thawing test, the specimen at the fresh water has over 90$\%$ of durability factor, but another specimen at 1$\%$ of salt water has 0$\%$ of durability factor at 140 cycles of the freezing-thawing. The result means that frost damage is sccelerated at the salt water. Therefore, the deterioration of the concrete deck is estimated to be occured by combined effects of freezing-thawing and chloride ion attack.

  • PDF