• Title/Summary/Keyword: combined system

Search Result 5,643, Processing Time 0.034 seconds

Comparison of infiltation rate for separate sewer system and combined sewer system in sewer maintenance areas (하수관로정비 지역의 분류식과 합류식 하수관로의 침입율 비교)

  • Gu, Gwangmo;Chu, Shaoxiong;Lim, Bongsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.191-200
    • /
    • 2020
  • This study is to improve the efficiency of BTL (Build Transfer Lease) project operation by comparing the infiltration rate based on the data of 5 years of infiltration of the separate sewer system and combined sewer system. In the survey site, the separate sewer system area consists of eight flowmeters in seven treatment basins, and the combined sewer system area consists of eight flowmeters in five treatment basins. The infillration rate was analyzed by night-time domestic flow evaluation method, and the average infiltration rates of the separate sewer system and combined sewer system were 13% and 16%, respectively. Combined sewer system was about 1.3 times higher than the separate sewer system. The average BOD of separate sewer system was 233 mg/L, which was about 2.4 times higher than the combined sewer system was 107 mg/L. In the comparison of the average pipe diameter-length infiltration of separate sewer system and combined sewer system, the separate sewer system and the combined sewer system were about 0.150 ㎥/d/mm/km and about 0.109 ㎥/d/mm/km, respectively. The floating population in mixed residential and commercial areas has been identified as the cause. Therefore, we propose a method to calculate the infiltration rate in consideration of the margin ratio in the area where the night active population is concentrated.

Study on stability and design guidelines for the combined system of scaffolds and shores

  • Peng, Jui-Lin;Wang, Chung-Sheng;Wang, Shu-Hong;Chan, Siu-Lai
    • Steel and Composite Structures
    • /
    • v.35 no.3
    • /
    • pp.385-404
    • /
    • 2020
  • Since the scaffold is composed of modular members, the total height of multi-story scaffolds does not often meet with the headroom of construction buildings. At this time, other supporting members need to be set up on the top of scaffolds. However, the mechanical behaviors of the combined system of scaffolds and other supporting members have seldom been discussed. This study explores the stability of the combined system of scaffolds and shores. The loading tests conducted in the laboratory show that the critical load of the combined system of two-story scaffolds and wooden shores is about half that of the three-story scaffold system with the same height. In the failure of both the "scaffold system" and the "combined system of scaffolds and shores' after loading, the deformation mainly occurs in the in-plane direction of the scaffold. The outdoor loading test shows that no failure occurs on any members when the combined system fails. Instead, the whole system buckles and then collapses. In addition, the top formwork of the combined system can achieve the effect of lateral support reinforcement with small lateral support forces in the outdoor loading test. This study proposes the preliminary design guidelines for the scaffolding structural design.

The Study of Continuous System Combined with Distributed DVA (II) (분포질량 동흡진기가 부착된 연속체 시스템에 대한 연구 (II))

  • Choi, Jeung-Hyun;Lim, Byoung-Duk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.215-221
    • /
    • 2004
  • Large machine and structure can not be normally treated as lumped parameter system. Such machine or structure must be broken down to individual beams or panels the motion of which must be analysed before an absorber system can be designed for each element. The absorber may be a lumped parameter system or a continuous system. One of the most common elements in a machine or structure is the cantilever, and in this paper is considered the design of a continuous parameter absorber to reduce the transverse vibrations of a beam. So this paper describes the method to obtain the accurate information about combined continuous beam system with DVA. This information is obtained from the combined system's receptance. and this paper shows the convenience and useful informations when design the dynamic vibration absorber with the combined system's receptance.

Analysis of Distance between ATS and ATP Antenna for Normal Operation in Combined On-board Signal System

  • Kim, Minseok;Kim, Minkyu;Kim, Doogyum;Lee, Jongwoo
    • International Journal of Railway
    • /
    • v.5 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Railroad signaling systems are to control intervals and routes of trains. There are ATS, ATP, ATO and ATC system. Trains are operated in the section which is met on the signaling system because various signaling systems are used in Korea. Hence, trains are not operated in the section which is used in the other signaling system. To solve this problem, recently combined on-board system has been developed. The combined on-board system designed by doubling the ATS, ATP and ATC system to ensure the safety of system. The inductance of antenna is change and in return the resonance frequency of antenna is varied by the electromagnetic induction. Therefore, the information signal is not received exactly in the combined on-board system and in return accidents between trains occur. In this paper, electric model of the combined on-board system for considering the ATS and ATP antenna is presented. Moreover, the mutual inductance including the distance between the ATS and ATP antenna is calculated. As a result of the frequency response of the antennas, the mutual inductance met on operation range of resonance frequency is defined.

Design Performance Analysis of Micro Gas Turbine-Organic Rankine Cycle Combined System (마이크로 가스터빈과 유기매체 랜킨사이클을 결합한 복합시스템의 설계 성능해석)

  • Lee Joon Hee;Kim Tong Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.536-543
    • /
    • 2005
  • This study analyzes the design performance of a combined system of a recuperated cycle micro gas turbine (MGT) and a bottoming organic Rankine cycle (ORC) adopting refrigerant (R123) as a working fluid. In contrast to the steam bottoming Rankine cycle, the ORC optimizes the combined system efficiency at a higher evaporating pressure. The ORC recovers much greater MGT exhaust heat than the steam Rankine cycle (much lower stack temperature), resulting in a greater bottoming cycle power and thus a higher combined system efficiency. The optimum MGT pressure ratio of the combined system is very close to the optimum pressure ratio of the MGT itself. The ORC's power amounts to about $25\%$ of MGT power. For the MGT turbine inlet temperature of $950^{\circ}C$ or higher, the combined system efficiency, based on shaft power, can be higher than $45\%$.

Interruption analysis of the SFCL-combined DC circuit breaker system using current-limiting technology

  • Kim, Jun-Beom;Jeong, In-Sung;Choi, Hye-Won;Choi, Hyo-Sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.4
    • /
    • pp.30-34
    • /
    • 2016
  • In this study, a SFCL-combined DC circuit breaker system was proposed by applying the current-limiting technology for DC circuit breaking. The SFCL-combined circuit breaker system consists of a mechanical DC circuit breaker combined with superconductors. To ensure the reliable structure and operation of the SFCL-combined circuit breaker system, a simulation grid was designed using the EMTDC/PSCAD program, and simulation was conducted. The results showed that the SFCL-combined DC circuit breaker system with superconductors limited the maximum fault current by 37%. In addition, the burden on the DC circuit breaker was decreased by 87%.

A Study on the ESS Integration Plan with Inner PCS of Wave-Offshore Hybrid Generation System for Maximizing Power Profile Stability (복합발전의 공급전력 안정성 극대화를 위한 파력발전 PCS의 BESS 연동방안 연구)

  • Jung, Seungmin;Kim, Hyun-Wook;Yoo, Yeuntae;Jang, Gilsoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.82-91
    • /
    • 2014
  • The combined generator system by integrating several renewable energy sources can share the electrical infrastructure and therefore have the advantage of constructing not only the transmission system but also the power conversion system. Among the various combined renewable system, the wind power and wave power has a high possibility of future growth due to the economic feasibility in offshore environment. This kind of large-scale combined systems might be follow the determination by the transmission system operator's directions and control the output profile by focusing at PCC. However, both renewable energies are depend on the unpredictable environmental variation; it is needed to do the compensation devices. In this paper, the ESS compensation plan is proposed to do output determination of the combined generator system by paying attention to active power of utility grid with the analysis of the controllable elements of the wind and wave power generator. The improvement of the new application technique of the combined system is confirmed through using the PSCAD/EMTDC. The entire simulation process was designed by adopting the active power control according to the reference signal of TSO.

Plan of Information System for Combined Treatment of the Oriental and the Western Medicine (한.양방 협진 정보시스템 구축방안 연구)

  • Yea, Sang-Jun;Jang, Hyun-Chul;Kim, Chul;Kim, Jin-Hyun;Kim, Sang-Kyun;Song, Mi-Young
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2009
  • Background : Recently, Medical Act was amended to encourage the induction of combined treatment between Oriental Medicine doctors and Western doctors. As yet, the information infra for combined treatment has not been studied. Objectives : This study aimed to design the architecture of information system for combined treatment of the Oriental and the Western Medicine. Methods : First, we defined the information of combined treatment through the analysis of research trends from the inside and outside of the country. Because the data compatibility is very important, the definition of information must be ahead of anything else. Second, we designed the architecture of information system based on the prior definition. Results : We classified the information for combined treatment by subject such as law, clinic, research, manpower, facilities, and education. In this paper information system examined in three aspects. First the infra layer is organized as hardware, netware, and security. Second is data warehouse layer for the storing, filtering, and extraction of data. Third is service layer which is related to data transmission. And Finally all information for combined treatment is provided through the portal system for medical consumer, political planner, and R&D researcher. Conclusion : In this paper, we studied the essential factors of combined treatment information in the view point of information system. But the detailed design and implementation of information system must be followed to effect this results.

  • PDF

A Study on the Characteristics of the Combined Generation System by Solar and Wind Energy with Power Storage Apparatus for the Geographical Features

  • Lim, Jung-Yeol;Kang, Byeong-bok;Cha, In-Su
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • The development of the solar and the wind energy is necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently MW Class power generation system has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic and wind power was suggested. It combines wind power energy and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with everchanging weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added for the present study.

Analysis on the Operational Characteristics of the Combined Generation System with Power Storage Apparatus that Apply Microcontroller

  • Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.12B no.1
    • /
    • pp.24-30
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative, energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a flew faults with the weather condition. In order to solve these existing problem combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added far the present study. In an experiment, when output of combined generation system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.