• Title/Summary/Keyword: combined screening

Search Result 211, Processing Time 0.03 seconds

Combined Screening of Cervical Cancer, Breast Cancer and Reproductive Tract Infections in Rural China

  • Li, Zhi-Fang;Wang, Shao-Ming;Shi, Ju-Fang;Zhao, Fang-Hui;Ma, Jun-Fei;Qiao, You-Lin;Feng, Xiang-Xian
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.7
    • /
    • pp.3529-3533
    • /
    • 2012
  • Objectives: To investigate the current prevalence and knowledge of cervical cancer, breast cancer and reproductive tract infections (RTIs) in rural Chinese women, and to explore the acceptance and feasibility of implementing a combined screening program in rural China. Methods: A population-based, cross-sectional study was conducted among women aged 30 to 59 years old in Xiangyuan County, Shanxi Province from 2009 to 2010. Socio-demographic characteristics, knowledge of cervical cancer, breast cancer and RTIs, and the attitude toward single or combined screening were collected by an interview questionnaire. Each participant received a clinical examination of the cervix, breast and reproductive tract. Examinations included visual inspection, mammography, laboratory tests and pathological diagnosis. Results: A total of 1,530 women were enrolled in this study. The prevalence of cervical precancerous lesions, suspicious breast cancer, suspicious benign breast disease and RTIs was 1.4%, 0.2%, 14.0% and 54.3%, respectively. Cervicitis, trichomonas vaginitis, and bacterial vaginitis were the three most common RTIs among our participants. Television, radio broadcast, and public education during screening were the major source of healthcare knowledge in rural China. Moreover 99.7% of women expressed great interest in participating in a combined screening project. The affordable limit for combined screening project was only 50 RMB for more than half of the rural women. Conclusion: A combined screening program would be more effective and popular than single disease screening projects, while appropriate accompanied education and a co-pay model for its successful implementation need to be explored, especially in low-resource settings.

Evaluation of the efficacy of nutritional screening tools to predict malnutrition in the elderly at a geriatric care hospital

  • Baek, Myoung-Ha;Heo, Young-Ran
    • Nutrition Research and Practice
    • /
    • v.9 no.6
    • /
    • pp.637-643
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Malnutrition in the elderly is a serious problem, prevalent in both hospitals and care homes. Due to the absence of a gold standard for malnutrition, herein we evaluate the efficacy of five nutritional screening tools developed or used for the elderly. SUBJECTS/METHODS: Elected medical records of 141 elderly patients (86 men and 55 women, aged $73.5{\pm}5.2years$) hospitalized at a geriatric care hospital were analyzed. Nutritional screening was performed using the following tools: Mini Nutrition Assessment (MNA), Mini Nutrition Assessment-Short Form (MNA-SF), Geriatric Nutritional Risk Index (GNRI), Malnutrition Universal Screening Tool (MUST) and Nutritional Risk Screening 2002 (NRS 2002). A combined index for malnutrition was also calculated as a reference tool. Each patient evaluated as malnourished to any degree or at risk of malnutrition according to at least four out of five of the aforementioned tools was categorized as malnourished in the combined index classification. RESULTS: According to the combined index, 44.0% of the patients were at risk of malnutrition to some degree. While the nutritional risk and/or malnutrition varied greatly depending on the tool applied, ranging from 36.2% (MUST) to 72.3% (MNA-SF). MUST showed good validity (sensitivity 80.6%, specificity 98.7%) and almost perfect agreement (k = 0.81) with the combined index. In contrast, MNA-SF showed poor validity (sensitivity 100%, specificity 49.4%) and only moderate agreement (k = 0.46) with the combined index. CONCLUSIONS: MNA-SF was found to overestimate the nutritional risk in the elderly. MUST appeared to be the most valid and useful screening tool to predict malnutrition in the elderly at a geriatric care hospital.

DVSF: A Distributed System for Virtual Screening (DVSF: 가상 검색을 위한 분산 시스템)

  • 황석찬;최종선;이상근;임재훈;최재영;노경태;이지수
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.1
    • /
    • pp.25-32
    • /
    • 2003
  • As one of a new generation of industries, biotechnology is currently spotlighted, and is creating new research and industrial areas that can be readily combined with information technology. Among them, virtual screening is a method for new drug design which uses computer simulation to virtually design active drug candidates for special disease. In this paper, we present a distributed system for virtual screening, called DVSF(Distributed Virtual Screening Facilities). DVSF is designed and developed to perform virtual screening efficiently on logically distributed idle or strategic resources in a small or medium scale laboratory.

Accuracy of Combined Visual Inspection with Acetic Acid and Cervical Cytology Testing as a Primary Screening Tool for Cervical Cancer: a Systematic Review and Meta-Analysis

  • Chanthavilay, Phetsavanh;Mayxay, Mayfong;Phongsavan, Keokedthong;Marsden, Donald E;White, Lisa J;Moore, Lynne;Reinharz, Daniel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5889-5897
    • /
    • 2015
  • Background: The performance of combined testing visual inspection with acetic acid (VIA) and cervical cytology tests might differ from one setting to another. The average estimate of the testing accuracy across studies is informative, but no meta-analysis has been carried out to assess this combined method. Objective: The objective of this study was to estimate the average sensitivity and specificity of the combined VIA and cervical cytology tests for the detection of cervical precancerous lesions. Materials and Methods: We conducted a systematic review and a meta-analysis, according to the Cochrane Handbook for Systematic Review of Diagnostic Test Accuracy. We considered two cases. In the either-positive result case, a positive result implies positivity in at least one of the tests. A negative result implies negativity in both tests. In the both-positive case, a positive result implies having both tests positive. Eligible studies were identified using Pubmed, Embase, Website of Science, CINHAL and COCRANE databases. True positive, false positive, false negative and true negative values were extracted. Estimates of sensitivity and specificity, positive and negative likelihood (LR) and diagnostic odds ratios (DOR) were pooled using a hierarchical random effect model. Hierarchical summary receiver operating characteristics (HSROC) were generated and heterogeneity was verified through covariates potentially influencing the diagnostic odds ratio. Findings: Nine studies fulfilled inclusion criteria and were included in the analysis. Pooled estimates of the sensitivities of the combined tests in either-positive and both-positive cases were 0.87 (95% CI: 0.83-0.90) and 0.38 (95% CI: 0.29-0.48), respectively. Corresponding specificities were 0.79 (95% CI: 0.63-0.89) and 0.98 (95% CI: 0.96-0.99) respectively. The DORs of the combined tests in either-positive or both-positive result cases were 27.7 (95% CI: 12.5-61.5) and 52 (95% CI: 22.1-122.2), respectively. When including only articles without partial verification bias and also a high-grade cervical intraepithelial neoplasia as a threshold of the disease, DOR of combined test in both-positive result cases remained the highest. However, DORs decreased to 12.1 (95% CI: 6.05-24.1) and 13.8 (95% CI: 7.92-23.9) in studies without partial verification bias for the combined tests in the either-positive and both-positive result cases, respectively. The screener, the place of study and the size of the population significantly influenced the DOR of combined tests in the both-positive result case in restriction analyses that considered only articles with CIN2+ as disease threshold. Conclusions: The combined test in the either-positive result case has a high sensitivity, but a low specificity. These results suggest that the combined test should be considered in developing countries as a primary screening test if facilities exist to confirm, through colposcopy and biopsy, a positive result.

Development of a Delirium Occurrence Screening Model for Patients in Medical Intensive Care Units (내과계 중환자 섬망발생 선별모형 개발)

  • Lee, Hyun Sim;Kim, So Sun
    • Journal of Korean Clinical Nursing Research
    • /
    • v.19 no.3
    • /
    • pp.357-368
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate risk factors related to delirium and to develop screening model on delirium occurrence in MICU (Medical Intensive Care Unit) patients. Methods: For developing a preliminary tool for delirium, the data of 166 patients were collected and analyzed. In order to estimate the accuracy and discriminating power for the developed screening model, 98 patients were enrolled. The data used in this study were collected by EMR (Electronic Medical Record) review from January to September in 2012. The collected data were analyzed using SPSS/PC Win 18.0 program. Results: Screening model on delirium in MICU patients was developed using the results of logistic regression. The total score of screening model was 24 point and measuring point was 10 point. When the measuring point is over 10 point, it means that the risk of delirium occurrence is high. The discriminating power and the validity of screening model showed AUC .908 (p <.001) and .935 (p <.001) respectively. This result showed that the screening model on delirium which developed in this study was an appropriate model for screening the delirium risk group in MICU. The sensitivity of the screening model was 83%, specificity 89% and accuracy 84%. Conclusion: The developed screening model on delirium occurrence in MICU should be combined with EMR for screening and preventing delirium in a high risk group.

First trimester screening for trisomy 18 by a combination of nuchal translucency thickness and epigenetic marker level

  • Lee, Da Eun;Kim, Shin Young;Kim, Hyun Jin;Park, So Yeon;Kim, Min Hyoung;Han, You Jung;Ryu, Hyun Mee
    • Journal of Genetic Medicine
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • Purpose: The aim of this study was to assess the diagnostic efficacy of noninvasive prenatal screening for trisomy 18 by assessing the levels of unmethylated-maspin (U-maspin) and fetal nuchal translucency (NT) thickness during the first trimester of pregnancy. Materials and Methods: A nested case-control study was conducted using maternal plasma samples collected from 65 pregnant women carrying 11 fetuses with trisomy 18 and 54 normal fetuses. We compared the U-maspin levels, NT thicknesses, or a combination of both in the first trimester between the case and control groups. Results: U-maspin levels and NT thickness were significantly elevated in the first trimester in pregnant women carrying fetuses with trisomy 18 when compared to those carrying normal fetuses (27.2 vs. 6.6 copies/mL, P<0.001 for U-maspin; 5.9 vs. 2.0 mm, P<0.001 for NT). The sensitivities of the U-maspin levels and NT thickness in prenatal screening for fetal trisomy 18 were 90.9% and 90.9%, respectively, with a specificity of 98.1%. The combined U-maspin levels and NT thickness had a sensitivity of 100% in prenatal screening for fetal trisomy 18, with a specificity of 98.1%. Conclusion: A combination of U-maspin levels and NT thickness is highly efficacious for noninvasive prenatal screening of fetal trisomy 18 in the first trimester of pregnancy.

Applicability of screenings for shotcrete's combined aggregates (숏크리트용 혼합골재로서 스크리닝스의 활용성 연구)

  • Han, Seung-Hwan;Yoo, Tae-Seok;Kim, Nag-Young;Kim, Hong-Jong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.149-160
    • /
    • 2013
  • In the mix proportion of shotcrete, it was analyzed as required in terms of eco-friendly technology to take advantage of the screenings. Screenings of recycling can be a solution in order to overcome the quality degradation due to the recent lack of good quality sand as well as the utilization of waste materials. Five regional screening and screening replaced fine aggregates for physical characteristics were analyzed to evaluate the usability screenings as shotcrete's combined aggregate. It was analyzed the effect of particle size distribution in the combined aggregate for shotcrete and maximum replacement was estimated according to the type of screenings.

A Estimation Method for Ratio of Generator Composition included Combined Heat and Power Using Screening Curve Method (열병합발전이 고려된 심사곡선법에 의한 전원구성 비율 산정방법의 연구)

  • Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Kyu;Kim, Mi-Ye;Yeon, Jun-Hee;Kim, Myung-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.736-738
    • /
    • 2005
  • For calculating optimal generation composition of The Basic Plan of Long Term Electricity Supply & Demand, the Screening Curve Method that using generation cost for planning is needed. This paper will induce optimal power system ratio included Combined Head and Power and suggest the method for optimal generation composition of The Basic Plan of Long Term Electricity Supply & Demand that considered policy side.

  • PDF

The First Newborn Screening Study of T-Cell Receptor Excision Circle and κ-Deleting Recombination Excision Circle for Severe Combined Immunodeficiency in Korea: A Pilot Study (국내 최초 T-Cell Receptor Excision Circle과 κ-Deleting Recombination Excision Circle 신생아 선별검사에 관한 연구)

  • Son, Sohee;Kang, Ji-Man;Kim, Jong Min;Sung, Sein;Kim, Yi-Seoul;Lee, Haejeong;Kim, BitA Reum;Lee, Yeon Kyoung;Ko, Sun Young;Shin, Son Moon;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.24 no.3
    • /
    • pp.134-140
    • /
    • 2017
  • Purpose: Severe combined immunodeficiency (SCID) is the most serious form of primary immunodeficiency. Infants with SCID are susceptible to life-threatening infections. To establish newborn screening for SCID in Korea, we performed a screening test for T-cell receptor excision circle (TREC) and ${\kappa}$-deleting recombination excision circle (KREC) in neonates and investigated the awareness of SCID among their parents. Methods: Collections of dried blood spots from neonates and parent surveys were performed at the Samsung Medical Center and Cheil General Hospital & Women's Healthcare Center in Korea. The amplification crossing point (Cp) value <37.0 was defined as TREC/KRECpositive based on cutoff values from measuring multiplex real-time polymerase chain reaction. A Cp value >39.0 was defined as negative. Results: For TREC/KREC screening, 141 neonates were enrolled; 63 (44.7%) were male. One hundred forty neonates (99.3%) had positive TREC/KREC results at the time of the initial test; 82.3% and 75.9% were positive and 17.0% and 23.4% were weakly positive for TREC and KREC, respectively. In one neonate (0.7%), the initial TREC/KREC test result was negative. However, repeated tests obtained and confirmed a positive result. For an awareness survey, 168 parents were engaged. Only 2% of parents (3/168) knew that the newborn screening test for SCID had been introduced and performed in other countries. Eighty-four percent of parents (141/168) replied that nationwide newborn SCID screening should be performed in Korean newborns. Conclusions: In this study, newborn SCID screening was performed along with assessment of public awareness of the SCID test in Korea. The study results showed that newborn SCID screening can be readily applied for clinical use at a relatively low cost in Korea.

A Combined Multiple Regression Trees Predictor for Screening Large Chemical Databases (대용량 화학 데이터 베이스를 선별하기위한 결합다중회귀나무 예측치)

  • 임용빈;이소영;정종희
    • The Korean Journal of Applied Statistics
    • /
    • v.14 no.1
    • /
    • pp.91-101
    • /
    • 2001
  • It has been shown that the multiple trees predictors are more accurate in reducing test set error than a single tree predictor. There are two ways of generating multiple trees. One is to generate modified training sets by resampling the original training set, and then construct trees. It is known that arcing algorithm is efficient. The other is to perturb randomly the working split at each node from a list of best splits, which is expected to generate reasonably good trees for the original training set. We propose a new combined multiple regression trees predictor which uses the latter multiple regression tree predictor as a predictor based on a modified training set at each stage of arcing. The efficiency of those prediction methods are compared by applying to high throughput screening of chemical compounds for biological effects.

  • PDF