• Title/Summary/Keyword: combined device

Search Result 499, Processing Time 0.026 seconds

Real-time Monitoring of Colloidal Nanoparticles using Light Sheet Dark-field Microscopy Combined with Microfluidic Concentration Gradient Generator (μFCGG-LSDFM)

  • Choe, Hyeokmin;Nho, Hyun Woo;Park, Jonghoon;Kim, Jin Bae;Yoon, Tae Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.2
    • /
    • pp.365-370
    • /
    • 2014
  • For real-time monitoring of colloidal nanoparticles (NPs) in aqueous media, a light sheet type dark-field microscopy system combined with a microfluidic concentration gradient generator (${\mu}FCGG$-LSDFM) was developed. Various concentrations of colloidal Au NPs were simultaneously generated with the iFCGG and characterized with the LSDFM setup. The number concentrations and hydrodynamic size distributions were measured via particle counting and tracking analysis (PCA and PTA, respectively) approaches. For the 30 nm Au NPs used in this study, the lower detection limit of the LSDFM setup was 3.6 ng/mL, which is about 400 times better than that of optical density measurements under the same ${\mu}FCGG$ system. Additionally, the hydrodynamic diameter distribution of Au NPs was estimated as $39.7{\pm}12.2nm$ with the PTA approach, which agrees well with DLS measurement as well as the manufacturer's specification. We propose this ${\mu}FCGG$-LSDFM setup with features of automatic generation of NP concentration gradient and real-time monitoring of their physicochemical characteristics (e.g., number concentration, and hydrodynamic size distribution) as an important component of future high-throughput screening or high-content analysis platforms of nanotoxicity.

Increase in Voltage Efficiency of Picoinjection using Microfluidic Picoinjector Combined Faraday Moat with Silver Nanoparticles Electrode (은 나노입자 전극과 패러데이 모트를 이용한 미세유체 피코리터 주입기의 전압효율 상승)

  • Noh, Young Moo;Jin, Si Hyung;Jeong, Seong-Geun;Kim, Nam Young;Rho, Changhyun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.472-477
    • /
    • 2015
  • This study presents modified microfluidic picoinjector combined Faraday moat with silver nanoparticle electrode to increase electrical efficiency and fabrication yield. We perform simple dropping procedure of silver nanoparticles near the picoinjection channel, which solve complicate fabrication process of electrode deposition onto the microfluidic picoinjector. Based on this approach, the microfluidic picoinjector can be reliably operated at 180 V while conventional Faraday moat usually have performed above 260 V. Thus, we can reduce the operation voltage and increase safety. Furthermore, the microfluidic picoinjector is able to precisely control injection volume from 7.5 pL to 27.5 pL. We believe that the microfluidic picoinjector will be useful platform for microchemical reaction, biological assay, drug screening, cell culture device, and toxicology.

Development of a Tensile Cell Stimulator to Study the Effects of Uniaxial Tensile Stress on Osteogenic Differentiation of Bone Marrow Mesenchymal Stem Cells (세포 인장 자극기의 개발과 세포 인장 자극을 통한 성체 줄기세포의 골분화 유도)

  • Shin, Hyun-Jun;Lee, Woo-Teak;Park, Suk-Hoon;Lee, Sun-Hwa;Park, Jung-Ho;Yoon, Yong-San;Shin, Jennifer H.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.7
    • /
    • pp.629-636
    • /
    • 2009
  • Mechanical stimulation is known to play a vital role on the differentiation of mesenchymal stem cells (MSCs) to pre-osteoblasts. In this research, we developed a tensile cell stimulator, composed of a DC motor-driven actuator and LVDT sensor for measuring linear displacement, to study the effects of tensile stress on osteogenic differentiation of MSCs. First, we demonstrated the reliability of this device by showing the uniform strain field in the silicon substrate. Secondly, we investigated the effects of tensile stretching on osteogenic differentiation. We imposed a pre-set cyclic strain at a fixed frequency on cell monolayer cultured on a flexible silicon substrate while varying its amplitude and duration. 60 min of resting period was allowed between 30 min of cyclic stretching and this cycle is repeated up to 7 days. Under the combined stimulation with osteogenic media and mechanical stretching, the osteogenic markers such as alkaline phosphatase (ALP), osterix, and osteopontin began to get expressed as early as 4 days of stimulation, which is much shorter than what is typically required for osteogenic media induced differentiation. Moreover, different markers were induced at different magnitudes of the applied strains. Lastly, for the case of ALP, we observed the antagonistic effects of osteogenic media when combined with mechanical stretching.

Uncertainty Evaluation of the Analysis of 11-Nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol in Human Urine by GC/MS (GC/MS를 이용한 소변 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Jeong, Jae-Chul;Suh, Sung-Ill;Suh, Yong-Jun;Lee, Jeong-Jik;Kim, Jong-Sang;In, Moon-Kyo
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.480-487
    • /
    • 2008
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH), the major metabolite of ${\Delta}^9$-tetrahydrocannabinol, in urine sample by solid-phase extraction (SPE) and GC/MS detection. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day and inter-person validation were performed using statistical analysis of several indicative factors. Measurement uncertainty associated with target analyte in real forensic samples was estimated using quality control (QC) data. Traceability of measurement was established through traceable standards, calibrated volumetric glassware and volume measuring device. The major factors of contribution to combined standard uncertainty, were calibration linearity, inter-day repeatability and inter-person reproducibility, while those associated with preparation of analytical standards and sampling volume were not so important considering the degree of contribution. Relative combined standard uncertainties associated with the described method was 12.05% for THCCOOH.

Side-Channel Attacks on Square Always Exponentiation Algorithm (Square Always 멱승 알고리듬에 대한 부채널 공격)

  • Jung, Seung-Gyo;Ha, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.3
    • /
    • pp.477-489
    • /
    • 2014
  • Based on some flaws occurred for implementing a public key cryptosystem in the embedded security device, many side-channel attacks to extract the secret private key have been tried. In spite of the fact that the cryptographic exponentiation is basically composed of a sequence of multiplications and squarings, a new Square Always exponentiation algorithm was recently presented as a countermeasure against side-channel attacks based on trading multiplications for squarings. In this paper, we propose Known Power Collision Analysis and modified Doubling attacks to break the Right-to-Left Square Always exponentiation algorithm which is known resistant to the existing side-channel attacks. And we also present a Collision-based Combined Attack which is a combinational method of fault attack and power collision analysis. Furthermore, we verify that the Square Always algorithm is vulnerable to the proposed side-channel attacks using computer simulation.

Torticollis Management Using the Customized Soft Neck Collar in CATCH 22 Syndrome Combined with Klippel-Feil Anomaly: A Case Report

  • Moon, Myung-Hoon;Kim, Soo-Yeon
    • Journal of Interdisciplinary Genomics
    • /
    • v.1 no.2
    • /
    • pp.19-22
    • /
    • 2019
  • CATCH 22 syndrome is rare genetic disease that has various manifestations. Cervical vertebral anomaly, such as Klippel-Feil anomaly, is frequently observed in the patients with CATCH22 syndrome. We present the case of an 11-year-old female patient with CATCH22 syndrome and Klippel-Feil anomaly who had been treated torticollis using the customized soft neck collar. During the patient's first visit to our clinic, she presented with low ear set, skull deformity, intellectual disability, and tilting of the head to the left by approximately 25 degrees. Imaging studies revealed multisegmental fusion and C3 hemivertebrae of the cervical spine and left thoracic scoliosis at T4 with 50 degrees of Cobb's angle. We instructed passive stretching and applied the customized soft neck collar we invented. The ipsilateral aspect of the neck collar is designed to provide vertical support between the clavicle and mandibular angle and is adjustable in height. The Velcro was attached to the neck collar at the point of contact with the ipsilesional mandibular angle, which provides negative sensory feedback, inducing her to tilt neck to the contralesional side. We applied the neck collar for 2 hours a day. After 1 year of treatment, her neck inclination angle improved from 25 to 10 degrees. Providing negative sensory feedback using the customized soft neck collar can be one of the treatment options of postural management in patients with torticollis in cases of CATCH 22 syndrome combined with Klippel-Feil anomaly.

Development of AUV's Waypoint Guidance Law and Verification by HILS (무인잠수정의 경로점 유도 법칙 설계 및 HILS 검증)

  • Hwang, Jong-Hyon;Yoo, Tae-Suk;Han, Yongsu;Kim, Hyun Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1417-1423
    • /
    • 2020
  • This paper proposes a waypoint guidance algorithm for the Autonomous Underwater Vehicle(AUV). The proposed simplified guidance algorithm is presented, which is combined LOS guidance and cross-track guidance for path following. Cross-track error is calculated using the position of the AUV and reference path. LOS guidance and cross-track guidance are appropriately changed according to cross-track error. And the stability of the system has been improved using variable cross-track control gain by cross-track error. Also, in this paper, navigation hardware in-the loop simulation(HILS) is implemented to verify navigation algorithm of AUV that performs combined navigation using inertial navigation device and doppler velocity log(DVL). Finally, we design integrated system HILS (including navigation HILS) for performance verification of guidance algorithm of the autonomous underwater vehicle. By comparing the sea test result with HILS result, the proposed guidance algorithm and HILS configuration were confirmed be correct.

The Effect of Mobilization Combined with Shoulder Active Contraction of Depth between the Coracoid Process and Humeral Head (어깨의 능동 수축을 동반한 관절가동술이 부리돌기와 위팔뼈 머리 사이의 거리에 미치는 영향)

  • Sun-min Kim;Sang-hun Jang
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.2
    • /
    • pp.69-75
    • /
    • 2023
  • Purpose: This study examined the distance between the coracoid process and the humeral head using an ultrasonography device when shoulder active contraction were applied according to the guided direction in the end range of shoulder mobilization. This study aims to provide essential data on treating shoulder disease patients. Methods: The subjects of this study were 20 adults with healthy shoulder joints. ultrasonography (US) equipment was used to examine shoulder joint mobilization under two conditions: (1) anteroposterior (AP) joint mobilization and (2) superoinferior (SI) joint mobilization. Shoulder active contraction was assessed in the end range. The distance between the coracoid process and the humeral head was measured. A linear probe was used for US; the frequency was set to 7.5MHz, and the US image display method was set to B-mode. The US measurement values were measured in (1) the starting position, (2) the end range position, and (3) the end range position of the shoulder active contraction, and the moving distance was drawn in a straight line through the US image. The distance was determined as the measurement value, and the average values were compared. Reults: The results were as follows: (1) the measured AP Joint mobilization increased by an average of .52cm from the end range of the joint mobilization with shoulder active contraction; (2) the measured SI Joint mobilization increased by an average of .49cm from the end range of the joint. Conclusion: When shoulder mobilization is applied, the distance between the coracoid process and the humeral head increases when muscle contraction occurs through shoulder active contraction in the end range, according to the therapist's guidance. Therefore, shoulder mobilization combined with shoulder active contraction is an effective treatment method for patients with shoulder injuries.

  • PDF

Co-sensitization of N719 with an Organic Dye for Dye-sensitized Solar Cells Application

  • Wu, Zhisheng;Wei, Yinni;An, Zhongwei;Chen, Xinbing;Chen, Pei
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.5
    • /
    • pp.1449-1454
    • /
    • 2014
  • The co-sensitization of N719 with a cyclic thiourea functionalized organic dye, coded AZ5, for dye-sensitized solar cells (DSSCs) was demonstrated. Due to its intensive absorption in ultraviolet region, AZ5 could compensate the loss of light harvest induced by triiodide, thereby the short-circuit photocurrent density ($J_{sc}$) was increased for co-sensitized (N719+AZ5) DSSC. Moreover, the electron recombination and dye aggregation were retarded upon N719 cocktail co-sensitized with AZ5, thus the open-circuit voltage ($V_{oc}$) of co-sensitized device was enhanced as well. The increased $J_{sc}$ (17.9 $mA{\cdot}cm^{-2}$) combined with the enhanced $V_{oc}$ (698 mV) ultimately resulted in an improved power conversion efficiency (PCE) of 7.91% for co-sensitized DSSC, which was raised by 8.6% in comparison with that of N719 (PCE = 7.28%) sensitized alone. In addition, co-sensitized DSSC exhibited a better stability than that of N719 sensitized device probably due to the depression of dye desorption.

Performance Analysis of Circulator-Based Collocated Device for Wi-Fi System and WiMAX System in Shared Band (주파수대역을 공유하는 Wi-Fi 시스템과 WiMAX 시스템이 결합된 써큘레이터 기반의 공존장치 성능 분석)

  • Kim, Dong-Eun;Kim, Jong-Woo;Park, Su-Won;Rhee, Seung-Hyong;Kang, Chul-Ho;Han, Ki-Young;Kang, Hyon-Goo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.6
    • /
    • pp.56-65
    • /
    • 2009
  • The single device that is combined more than one communication systems in shared band is called collocated system. In this paper, the collocated system is made by combination of Wi-Fi and WiMAX system. Performance of the collocated system is analysed by using two communication model, Collaborative and Non-Collaborative. To minimize the mutual interference between Wi-Fi and WiMAX system in collocated system, the circulator-based collocated system is proposed and analysed it's performance characteristics.