• Title/Summary/Keyword: combination resonance

Search Result 224, Processing Time 0.023 seconds

Determination of the Degree of Nonlinearity in the Response of Offshore Structures Using Higher Order Transfer Functions (고차 전이함수를 이용한 해양구조물 거동의 비선형도 결정)

  • 백인열
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.1
    • /
    • pp.116-125
    • /
    • 1995
  • Higher order nonlinear transfer functions are applied to model the nonlinear responses obtained Inn dynamic analysis of single degree of freedom systems (SDOF) subjected to wave and current loadings. The structural systems are subjected to single harmonic, two wave combination and irregular wave loading. Three different sources of nonlinearities are examined for each of the wave loading condition and it is shown that the nonlinear response appear at the resonance frequencies of the SDOF even when virtually no wave energy exists at those resonance frequencies. Higher order nonlinear transfer functions based on Volterra series representation are used to model the nonlinear responses mainly f3r the flexible systems and clearly shows the degrees of nonlinearity either as quadratic or cubic.

  • PDF

Effects of Korean Traditional Medicine Treatment on Spontaneous Osteonecrosis of the Knee: A Case Report

  • Lee, Soo-Kyung;Park, Eun-Young;Lee, June-Haeng;Kang, Sun-Woo;Won, Yoon-Jae;Yang, Myeong-Yeol;Ha, Jae-Joon
    • Journal of Acupuncture Research
    • /
    • v.39 no.1
    • /
    • pp.59-63
    • /
    • 2022
  • Spontaneous osteonecrosis of the knee (SONK) is a common form of osteonecrosis of the knee and mainly affects the medial condyle due to localized vascular insufficiency. We report a case of SONK in a 65-year-old woman who had severe knee pain in her left knee whichimpeded her capacityto walk beyond 10 minutes. Bilateral knee X-rays revealed degenerative osteoarthritis of both knees and magnetic resonance imaging revealed R/O SONK in the lateral aspect of the medial femoral condyle, as well as a medial meniscal posterior horn root tear, and a Grade 1 medial collateral ligament injury. She was hospitalized at Jaseng Hospital of Korean Medicine for 21 days and receivedcombination therapy includingacupuncture, pharmacopuncture, and herbal medicine. Patient-reported scales indicated that her pain and physical functional limitations were alleviated. Combination therapy consisting of Korean traditional medicine may bean alternative nonoperative treatment approach for patients with SONK.

Brain Tumor Detection Based on Amended Convolution Neural Network Using MRI Images

  • Mohanasundari M;Chandrasekaran V;Anitha S
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.10
    • /
    • pp.2788-2808
    • /
    • 2023
  • Brain tumors are one of the most threatening malignancies for humans. Misdiagnosis of brain tumors can result in false medical intervention, which ultimately reduces a patient's chance of survival. Manual identification and segmentation of brain tumors from Magnetic Resonance Imaging (MRI) scans can be difficult and error-prone because of the great range of tumor tissues that exist in various individuals and the similarity of normal tissues. To overcome this limitation, the Amended Convolutional Neural Network (ACNN) model has been introduced, a unique combination of three techniques that have not been previously explored for brain tumor detection. The three techniques integrated into the ACNN model are image tissue preprocessing using the Kalman Bucy Smoothing Filter to remove noisy pixels from the input, image tissue segmentation using the Isotonic Regressive Image Tissue Segmentation Process, and feature extraction using the Marr Wavelet Transformation. The extracted features are compared with the testing features using a sigmoid activation function in the output layer. The experimental findings show that the suggested model outperforms existing techniques concerning accuracy, precision, sensitivity, dice score, Jaccard index, specificity, Positive Predictive Value, Hausdorff distance, recall, and F1 score. The proposed ACNN model achieved a maximum accuracy of 98.8%, which is higher than other existing models, according to the experimental results.

Transmitted Noise Reduction of Piezoelectric Smart Panels using Passive/Active Method in Wide Range frequency (수동/능동적 방법을 혼용한 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;박우철
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.73-79
    • /
    • 2001
  • In this paper, the transmitted noise reduction performance of piezoelectric smart panels is experimentally studied. The proposed piezoelectric smart panels are comprised of plate structure on which piezoelectric sensor/actuators are bonded and sound absorbing material is provided. It is a combination of passive and active approaches utilizing a passive effect at high frequencies and an active effect at low frequencies. To prove the concept of piezoelectric smart panels, an acoustic measurement experiment is performed. An acoustic tunnel is designed and its acoustic characteristics are tested. Below 800Hz, the tunnel exhibits a plane wave guide characteristics. When an absorbing material is bonded on a single plate, a remarkable transmitted noise reduction in mid frequency range is observed except the first resonance frequency. By enabling the active control of single smart panel with negative feedback control. about 10dB noise reduction is achieved at the resonance frequencies. The double smart panel got 4dB at the first resonance frequency and has more potential to reduce the transmitted noise in a wide range frequency. Piezoelectric smart panels incorporating passive absorbing material and active piezoelectric devices is a promising technology for noise reduction in a wide range frequency.

  • PDF

A Comparison Study of Magnetic Resonance Imaging Findings and Neurological Signs in Canine Brain Diseases

  • Kim, Min-Ju;Song, Joong-Hyun;Hwang, Tae-Sung;Lee, Hee-Chun;Yu, Do-Hyeon;Kang, Byeong-Teck;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.178-183
    • /
    • 2018
  • The object of this study was to compare magnetic resonance imaging (MRI) findings and neurological signs in canine brain diseases. Brain diseases can cause severe neurological deficits and may be life-threatening. The antemortem diagnosis of the brain diseases is difficult for the clinician, since definitive diagnosis is based upon histopathological confirmation. Brain diseases are often associated with specific clinical signs, signalment, progression, and location. Accurate lesion localization through neurological examination and MRI findings is helpful for developing a differential diagnosis. A retrospective study was performed to compare the neurological examination of dogs with suspected brain disease to the MRI findings. Based on this study, neurological examination is a reliable way to localize most brain lesions. Postural reaction deficits do not provide sufficient information to localize lesions. Additionally, not all brain lesions present clinical signs and inflammatory lesions may cause no detectable abnormalities on MRI. Therefore, in clinical practice, a combination of neurological examination and MRI findings recommended for accurate brain lesion localization.

Design of a Novel 2D-Metamaterial CRLH ZOR Antenna with a Microstrip Patch Capacitively Coupled to a Rectangular Ring (직각 링과 용량성 결합된 마이크로스트립 패치 구조의 새로운 2차원 메타 재질 구조 CRLH 0차 공진 안테나의 설계)

  • Jang, Geon-Ho;Kahng, Sung-Tek
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.143-151
    • /
    • 2010
  • In this paper, a novel rectangular patch antenna is proposed to have Zeroth Order Resonance(ZOR) generated based on the Metamaterial Complosite Right- and Left-Handed(CRLH) structure. Making the in-phase electric field over the entire antenna other than a half-wavelength as the fundamental resonance mode of a standard microstrip patch or its positive multiple, the metallic patch is suggested to be capacitively coupled with only one surrounding rectangular ring, different from the previous 1D ZOR antennas commonly having several metal cells in line. The performance of the proposed antenna is simulated by a 3D field solver that inputs the sizes of the physical structure corresponding to the equivalent circuit designed to have ZOR at 2.4 GHz. Consequently, the resonance frequency, the gain and the antenna efficiency are observed 2.4 GHz, 5 dB and 98%, respectively. Besides, the important property of the proposed antenna is addressed as the combination of the low profile as an advantage of microstrip patch antennas, and the omni-directional field pattern typical of monopole antennas.

Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)

  • Martin, Thomas;Wang, Yi;Rashid, Shams;Shao, Xingfeng;Moeller, Steen;Hu, Peng;Sung, Kyunghyun;Wang, Danny JJ
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.210-222
    • /
    • 2017
  • Purpose: To develop a novel combination of controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) with integrated SSFP (CAIPI-iSSFP) for accelerated SSFP imaging without banding artifacts at 3T. Materials and Methods: CAIPI-iSSFP was developed by adding a dephasing gradient to the balanced SSFP (bSSFP) pulse sequence with a gradient area that results in $2{\pi}$ dephasing across a single pixel. Extended phase graph (EPG) simulations were performed to show the signal behaviors of iSSFP, bSSFP, and RF-spoiled gradient echo (SPGR) sequences. In vivo experiments were performed for brain and abdominal imaging at 3T with simultaneous multi-slice (SMS) acceleration factors of 2, 3 and 4 with CAIPI-iSSFP and CAIPI-bSSFP. The image quality was evaluated by measuring the relative contrast-to-noise ratio (CNR) and by qualitatively assessing banding artifact removal in the brain. Results: Banding artifacts were removed using CAIPI-iSSFP compared to CAIPI-bSSFP up to an SMS factor of 4 and 3 on brain and liver imaging, respectively. The relative CNRs between gray and white matter were on average 18% lower in CAIPI-iSSFP compared to that of CAIPI-bSSFP. Conclusion: This study demonstrated that CAIPI-iSSFP provides up to a factor of four acceleration, while minimizing the banding artifacts with up to a 20% decrease in the relative CNR.

Imaging of self-assembled monolayers by surface plasmon microscope (표면 플라즈몬 현미경을 이용한 자기조립 단분자막의 이미징)

  • 표현봉;신용범;윤현철;양해식;김윤태
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.1
    • /
    • pp.97-102
    • /
    • 2003
  • Multi-channel images of 11-MUA(11-Mercaptoundecanoic acid) and 11-MUOH(11-Mercaptoundecanol) self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. The patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each point on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching, which are common in the detection methods based on fluorescence.

Surgery for a Case of Three-Compartment Trigeminal Schwannoma : Technical Aspects

  • Chung, Jong-Chul;Chung, Seung-Young;Kim, Seong-Min;Park, Moon-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.4
    • /
    • pp.383-387
    • /
    • 2010
  • Complete removal of three-compartment trigeminal schwannomas is a challenge to neurosurgeons. To expand exposure of each compartment, the combination and modification of skull base approaches are necessary. The 61-year-old woman was admitted with chronic headache. Preoperative magnetic resonance imaging showed $47{\times}50{\times}40\;mm$-sized tumor originating primarily in the middle cranial fossa extended to the posterior and the infratemporal fossa. We performed operation in five stage; 1. Zygomatic osteotomy, 2. Inferior temporal fossa plate removal and foramen ovale opening, 3. Cavernous sinus opening, 4. Tailored anterior petrosectomy, 5. Meckel's cave opening. Combination of skull base surgery should be concerned according to the patient. In this study, extradural basal extension with zygomatic osteotomy, interdural posterior extension with tailored anterior petrosectomy, and intracavemous exploration are reasonable options for remodeling three-compartment lesion into a single compartment. Tailoring of bone resection and exploring through natural pathway between meningeal layers accomplish single-stage operation for complete removal of tumors.

Performance Evaluation of IRB System Using Seismic Isolation Test (내진시험을 통한 IRB 시스템의 성능 평가)

  • Park, Young-Gee;Ha, Sung Hoon;Woo, Jae Kwan;Choi, Seung-Bok;Kim, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.401-406
    • /
    • 2013
  • This paper presents experimental evaluation of IRE (isolation roller bearing) seismic isolation device. From the combination of base isolation on the IRE system displacement response spectrum and acceleration response spectrum, the compressive strength and the coefficient of friction experiments. Also the IRE system is evaluated by environment test according to KS standards. Both the resonance and seismic experiments using a combination of the IRE and Natural Rubber Bearing (NRB) are performed in order to analyze the seismic isolation of the IRE system dynamic characteristics. For the given load and exciting frequency, the resonant frequency becomes lower, but the resonant magnification remains to be same. However, it is shown that when we consider the IRE only, the vibration on the table with the horizontal movement and the independent horizontal displacement due to the rolling motion of the plate and roller are significantly reduced. This result verifies that the proposed optimal design method of the IRE system is very effective.

  • PDF