• Title/Summary/Keyword: colonoscope

Search Result 18, Processing Time 0.029 seconds

자가구동 대장내시경 개발을 위한 생체내 마찰특성 연구

  • 김영태;권은영;성인하;김대은;김병규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.291-291
    • /
    • 2004
  • 현재 국내에서 꾸준히 증가추세를 보이는 대장관련 질환의 검진과 치료를 위해 대장내시경을 이용한 시술의 빈도가 높아지고 있다. 현재 이용되고 있는 대장내시경은 대부분 구조적으로 굵기는 약 1 cm 이며 길이는 약 1.5 m이다 이러한 내시경은 항문을 통한 삽입이 용이하도록 하기 위해 적당한 유연성과 동시에 축방향의 비교적 큰 Stiffness를 갖고 있으며 최근 개발되고 있는 제품들은 이러한 Stiffness의 조절이 가능하여 삽입이 효과적으로 이루어질 수 있도록 하고 있다.(중략)

  • PDF

Single Use (Disposable) Duodenoscope: Recent Development and Future

  • Kihyun Ryu;Sunguk Jang
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.191-196
    • /
    • 2022
  • Unlike simple forward-viewing endoscopes such as gastroscope or colonoscope, duodenoscope houses much more complex design to fulfil its function. This design differences leave duodenoscopes more prone to contamination from inadequate disinfection process and potential dissemination of pathogens. Recent reports on dissemination of infection through the duodenoscope mandated an overhaul of duodenoscope utilization including development of a disposable duodenoscope. This article reviews the current state of disposable duodenoscope development, including reported early efficacy as well as its future direction and utilization.

Motion Characteristics of Smart Capsule with Triangular Arrangement of Actuators (삼각 배치 구동에 의한 스마트 캡슐의 이동 특성)

  • 임형준;민현진;김병규;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.854-857
    • /
    • 2001
  • At present, colonoscopy is performed by means of quite long and flexible endoscopes and controlled manually. Although the flexibility of the distal tip allows the endoscope to follow the tortuous path of the colon, the insertion of the endoscope requires the endoscopist to exert forces on and to perform rotations of the proximal end; these actions cause discomfort to the patient. Though self-propelling colonoscopic systems has been suggested to overcome these problems, it is difficult to pass through highly curved regions of the intestine. In this paper, we introduce a steering mechanism for a self-propelling coloinlscope, the smart capsule, which has three actuator units. The mechanism is designed not only to move forward and backward but also to pass through the curved regions. We derived the governing equations of this mechanism. Active movements and motion control are developed.

  • PDF

Intussusception after Colonoscopy: A Case Report and Review of Literature

  • Hassan, Wan Amir Wan;Teoh, William
    • Clinical Endoscopy
    • /
    • v.51 no.6
    • /
    • pp.591-595
    • /
    • 2018
  • Intussusception after colonoscopy is an unusual complication. A MEDLINE search revealed only 7 reported cases. We present a report of a 28-year-old man who developed abdominal pain several hours after routine colonoscopy and in whom computed tomography (CT) revealed colocolic intussusception. We postulate that this condition is iatrogenic and induced by suctioning of gas on withdrawal of the colonoscope. A common observation among the reported cases was abdominal pain several hours after colonoscopy and right-sided intussusception. All cases had colonoscopy reaching the right side of the colon. Treatment for adult intussusception remains controversial with regard to reduction versus resection, especially given the high association with a pathological cause and malignancy. Among the 8 reported cases, only the current case did not require surgery. A combination of benign colonoscopy, CT, and the clinical picture should provide sufficient information to initially choose a more conservative treatment approach.

A study on the current status and perioperative management of antithrombotic in a general hospital

  • You, Seoung-Hee;Park, Sungwon
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.108-115
    • /
    • 2022
  • The purpose of this study is to investigate the actual status of antithrombotic management before and after the procedure or surgery, the difference between the duration of medication suspension by clinical and demographic characteristics, and the patient's understanding and satisfaction after medication management by a dedicated nurse. The results were as follows. The most commonly used antithrombotic agents were aspirin and flavitol. The drug discontinuation period according to antithrombotic, procedures, and underlying diseases, there was a significant difference in duration for each variables(p<.000). In the case of antiplatelet drugs, 5-day suspension was the most frequent, and anticoagulants 2-day suspension was the most frequent. Depending on the procedure,colonoscope,nucleoplasty,rotator cuff repair,and total knee arthroplasty commonly showed more than 80% of 5-day discontinuation. The differences according to underlying diseases are as follows. 64.7% of all diseases discontinued on the 5th. The patient's understanding of the nurse's medication management performed before and after the procedure was found to be lower in Angina patients than those with other diseases. In terms of age, those in their 50s showed higher understanding than other age groups. There were no differences in understanding and satisfaction with the remaining characteristics.

Outcomes of endoscopic retrograde cholangiography and percutaneous transhepatic biliary drainage in liver transplant recipients with a Roux-en-Y biliary-enteric anastomosis

  • Divyanshoo Rai Kohli;Bashar A. Aqel;Nicole L. Segaran;M. Edwyn Harrison;Norio Fukami;Douglas O. Faigel;Adyr Moss;Amit Mathur;Winston Hewitt;Nitin Katariya;Rahul Pannala
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.27 no.1
    • /
    • pp.49-55
    • /
    • 2023
  • Backgrounds/Aims: Data regarding outcomes of endoscopic retrograde cholangiography (ERC) in liver transplant (LT) recipients with biliary-enteric (BE) anastomosis are limited. We report outcomes of ERC and percutaneous transhepatic biliary drainage (PTBD) as first-line therapies in LT recipients with BE anastomosis. Methods: All LT recipients with Roux-BE anastomosis from 2001 to 2020 were divided into ERC and PTBD subgroups. Technical success was defined as the ability to cannulate the bile duct. Clinical success was defined as the ability to perform cholangiography and therapeutic interventions. Results: A total of 36 LT recipients (25 males, age 53.5 ± 13 years) with Roux-BE anastomosis who underwent biliary intervention were identified. The most common indications for a BE anastomosis were primary sclerosing cholangitis (n = 14) and duct size mismatch (n = 10). Among the 29 patients who initially underwent ERC, technical success and clinical success were achieved in 24 (82.8%) and 22 (75.9%) patients, respectively. The initial endoscope used for the ERC was a single balloon enteroscope in 16 patients, a double balloon enteroscope in 7 patients, a pediatric colonoscope in 5 patients, and a conventional reusable duodenoscope in 1 patient. Among the 7 patients who underwent PTBD as the initial therapy, six (85.7%) achieved technical and clinical success (p = 0.57). Conclusions: In LT patients with Roux-BE anastomosis requiring biliary intervention, ERC with a balloon-assisted enteroscope is safe with a success rate comparable to PTBD. Both ERC and PTBD can be considered as first-line therapies for LT recipients with a BE anastomosis.

Design of Sensor Network for Estimation of the Shape of Flexible Endoscope (연성 대장내시경의 형상추정을 위한 센서네트워크의 설계)

  • Lee, Jae-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • In this paper, a method of shape prediction of an endoscope handling robot that can imitate a surgeon's behavior using a sensor network is suggested. Unit sensors, which are composed of a 3-axis magnetometer and 3-axis accelerometer pair comprise the network through CAN bus communication. Each unit of the sensor is used to detect the angle of the points in the longitudinal direction of the robot, which is made from a flexible tube. The signals received from the sensor network were filtered using a low pass Butterworth filter. Here, a Butterworth filter was designed for noise removal. Finally, the Euler angles were extracted from the signals, in which the noise was filtered by the low path Butterworth filter. Using this Euler angle, the position of each sensor on the sensor network is estimated. The robot body was assumed to consist of links and joints. The position of each sensor can be assumed to be attached to the center of each link. The position of each link was determined using the Euler angle and kinematics equation. The interpolation was carried out between the positions of the sensors to be able to connect each point smoothly and obtain the final posture of the endoscope in operation. The experimental results showed that the shape of the colonoscope can be visualized using the Euler angles evaluated from the sensor network suggested and the shape of serial link estimated from the kinematics chain model.

A Case Report of Colonic Mucinous Adenocarcinoma in 27 Year Old Patient (27세 남자환자에서 발견된 대장의 점액선암종 1례)

  • Woo Sun Rou;Ju Seok Kim;Sun Hyung Kang;Hee Seok Moon;Jae Kyu Sung;Hyun Yong Jeong
    • Journal of Digestive Cancer Research
    • /
    • v.6 no.2
    • /
    • pp.69-72
    • /
    • 2018
  • Mucinous adenocarcinoma occurs in 1.6-25.4% of patients with colorectal cancer. We report a case of a 27-year-old man with negative findings on initial colonoscopic biopsy, but finally diagnosed with mucinous adenocarcinoma of the colon. After undergoing an abdominal CT due to persistent abdominal pain, he was transferred to our hospital. The abdominal CT showed a diffuse and irregular wall thickening in the distal transverse colon. Due to the edema and stenosis of colonic wall, it was difficult to insert the colonoscope into the proximal region; a biopsy revealed chronic colitis with lymphofollicular hyperplasia. Transverse colectomy and lymph node dissection were performed. The diagnosis was mucinous adenocarcinoma of approximately 20×4.5 cm. Compared to adenocarcinoma, mucinous adenocarcinoma is found in a younger population with an advanced stage and is less responsive to palliative chemotherapy. Therefore, recalcitrant abdominal pain even in young people warrants early detection through appropriate examinations such as abdominal CT and colonoscopy.

  • PDF