• Title/Summary/Keyword: collector efficiency

Search Result 326, Processing Time 0.024 seconds

Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating (온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석)

  • Sohn, Jin-Gug
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.5
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

Development of Passive-Type Daylighting System for Large Space (대공간 적용을 위한 패시브형 자연채광시스템 개발)

  • Sung, Tae-Kyung;Park, Yeon-Min;Kim, Joung-Min;Lee, Chung-Sik;Lee, Euol-Young;Joung, Che-Bong;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • Whereas recent domestic buildings and industrial facilities are being constructed as large as possible, the daylighting systems for the large space have rarely been developed. Domestic situation has been reported as only several small or medium sized daylighting systems have been developed, and the large scaled systems have entirely being imported from abroad. We have developed a large scaled daylighting system for the big space. The developed system have been evaluated in terms of the average system efficiency and daylighting factor. Each results are shown with tabulated experimental data.

Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon (활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성)

  • Byeon, Jeong-Hoon;Hwang, Jung-Ho;Ji, Jun-Ho;Kang, Suk-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules (액체식 PVT 복합모듈의 유형별 성능 비교 분석)

  • Kim, Jin-Hee;Kang, Jun-Gu;Kim, Jun-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

A study on the photocatalyst filter design using UV-C (UV-C를 이용한 광촉매 필터 디자인에 관한 연구)

  • Han, Sang Yun;Kang, Seung Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.276-282
    • /
    • 2019
  • The purpose of this study was to analyze the structure of general filter using ultrafine filter (Profilter), dust collector filter, HEPA (HAPA-High Efficiency Particulate Air) filter, deodorized filters, etc. of air purifiers and to study new types of purified filters that can improve ultrafine dust, harmful gases, and sterilization cleanup performance. The study was also conducted by adding photocatalyst filters to the existing step-by-step filtration filter types, which were proposed in the design three coupling structure filters of the left and right UV-LED installation frames and the photocatalyst coating honeycomb frame. Future research is needed on the effect of photocatalyst filters. This study was to investigate the application and structure of photocatalyst filters to air purifiers.

Role of network geometry on fluid displacement in microfluidic color-changing windows

  • Ucar, Ahmet Burak;Velev, Orlin D.;Koo, Hyung-Jun
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.865-884
    • /
    • 2016
  • We have previously demonstrated a microfluidic elastomer, which changes apparent color and could have potential applications in smart windows. The practical use of such functional microfluidic systems requires rapid and uniform fluid displacement throughout the channel network with minimal amount of liquid supply. The goal of this simulation study is to design various microfluidic networks for similar applications including, but not limited to, the color-switching windows and compare the liquid displacement speed and efficiency of the designs. We numerically simulate and analyze the liquid displacement in the microfluidic networks with serpentine, parallel and lattice channel configurations, as well as their modified versions with wide or tapered distributor and collector channels. The data are analyzed on the basis of numerical criteria defined to evaluate the performance of the corresponding functional systems. We found that the lattice channel network geometry with the tapered distributors and collectors provides most rapid and uniform fluid displacement with minimum liquid waste. The simulation results could give an important guideline for efficient liquid supply/displacement in emerging functional systems with embedded microfluidic networks.

System Development of Removing Dust and Odor from Manufacturing Process of FRP Products (FRP제품 가공시 발생하는 분진 및 악취 제거 시스템 개발)

  • Yun, Huy Kwan;Kim, Jae Yong
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.547-552
    • /
    • 2009
  • When fiber reinforced plastics (FRP) products are manufactured, dust and odor materials are inevitably generated in a workplace. To improve the bad condition of the workshop, we developed the Hybrid Bag Filter attached activated carbon fiber (ACF) and installed the system at two companies producing FRP goods. In order to raise the efficiency of dust collection, we set the ducts both on the ceiling and at the bottom of the wall and according to the circumstances of the workshop's space, moving dust collector also adopted as a different type of flexible duct. Pulse Jet Type Bag Filter is also equipped to operate the system more effectively, for the improved fine environment because of high dust removal efficiency. Finally, we investigated the removal tendency of the dust and odor when operating the System of Hybrid Bag Filter.

A Study on the Effect of Dust Precharging on Filtration Performance

  • Park, Y.O;Park, S.J.;Lee, J.H.;Kim, S.D.;Park, H.S.;Park, H.K.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.E2
    • /
    • pp.53-59
    • /
    • 2001
  • A hybrid dust-collector combining electrostatic charging with fabric filtration method was developed, and its performance characteristics were evaluated in this study. Charged particles build porous dendritic structure on the surfaces of filter by electrostatic attraction, increasing the collection efficiency of dust particles and reducing the pressure drop through the deposited dust layer and filter media. The cleaning performance of the dust layer is improved because the dendritic structured dust layer can be removed more easily by pulse jet cleaning flow. The results of the experiment showed a reduction of fine particle emission of 37% and the energy saving of 13% by precharging dust particles before filtration.

  • PDF

Study on the Development and Verification of Dry Manufacturing Technology for improving Quality of Recycled Fine Aggregate (순환잔골재 품질개선을 위한 건식생산기술의 개발 및 검증에 관한 연구)

  • Na, Chul-Sung;Choi, Hyeong-Gil;Kim, Young-Duck;Kwon, Soo-Kil;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.469-472
    • /
    • 2008
  • As recycled fine aggregate manufacturing technology with exceeding in economical efficiency, reduction efficiency of environmental load and quality improvement effect of recycled fine aggregate, it is to develop dry manufacturing system composed specific gravity separator of high-speed rotation impact type and centrifugal Force Powder Collector, etc. in this study. And it is to verify performance with evaluating quality of recycled fine aggregate. In consequence, it is identify that performance improvement effect of recycled fine aggregate by crushing recycled fine aggregate according to high-speed rotation impact, separating and collecting powder and minuteness dust according to centrifugal Force and mass defect, separating and reclaiming minuteness sand to mass defect.

  • PDF

A Study on Optimum Design of an Axial Cylcone structure using Response Surface Method (반응표면법을 활용한 축류형 사이클론 구조 최적화 설계에 관한 연구)

  • Cho, Jinill;Yun, Junho;Cho, Yeongkwang;Seok, Hyunho;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.17 no.3
    • /
    • pp.71-79
    • /
    • 2021
  • Ultrafine dust, which is emitted from industrial factories or all kinds of vehicles, threatens the human's respiratory system and our environment. In this regard, separating airborne particles is essential to mitigate the severe problem. In this work, an axial cyclone for the effective technology of eliminating harmful dust is investigated by numerical simulation using Ansys 2020, Fluent R2. In addition, the optimized structure of the cyclone is constructed by means of multi objective optimization based on the response surface method which is a representative method to analyze the effect of design parameter on response variables. Among several design parameters, the modified length of the vortex finder and dust collector is a main point in promoting the performance of the axial cyclone. As a result, the optimized cyclone exhibits remarkable performance when compared to the original model, resulting in pressure drop of 307 Pa and separator efficiency of 98.5%.