• 제목/요약/키워드: collector efficiency

검색결과 326건 처리시간 0.026초

단일 진공관형 집열기 히트파이프 작동유체에 따른 열성능 연구 (Thermal Performance Study of Various Heat Pipe Working Fluid for Evacuated Tubular Solar Collector)

  • 주홍진;김정배;김종보;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.97-103
    • /
    • 2007
  • This study was carried out to compare the thermal performance and operating characteristics of evacuated tubular solar collector(ETSC) with different working fluid. The evacuated tubular solar collectors with different working fluid of heat pipe were investigated in the same operating condition for a indoor experiment equipment. First, the result of working fluid with Water showed that $F_R({\tau}{\alpha})$ was 0.6636 and $F_RU_L$ was -1.8457 Second, Ethanol showed that $F_R({\tau}{\alpha})$ was 0.6147 and $F_RU_L$ was -0.6365. Third, Flutec-pp9 showed that $F_R({\tau}{\alpha})$ was 0.515 and $F_RU_L$ was -3.2313. Finally MA's showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_RU_L$ was -2.0086.

지역난방용 태양열시스템 (Solar District Heating System)

  • 백남춘;이진국;윤응상;윤석만;신우철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

태양열 및 외기 열원식 히트펌프 시스템 시뮬레이션 (Simulation of Solar and Ambient-air-assisted Heat Pump)

  • 백남춘;박준언;송병하;이진국;김홍제
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.17-24
    • /
    • 2000
  • Thermal performance of a SAAHPS (Solar and Ambient-air-assisted Heat Pump System) located in KIER is simulated with TRNSYS 14.2. The SAAHPS is composed of dual evaorators, each of which is used as a solar fluid heat source and an air fluid heat source. Polynomial coefficients data for the SAAHPS is supplied with Frigosoft, a program widely used for heat pump modeling. In general, collector area and storage volume are 2 key parameters in SAAHPS thermal performance. A parametric study is performed in this study to assess sensitivity of collector area and storage volume in SAAHPS. We concluded that firstly collector area and storage volume are the primary variables in SAAHPS thermal performance, secondly COP of SAAHPS is higher than that of conventional heat pumps. Therefore. collector efficiency can be enhanced swith SAAHPS during a heating season.

  • PDF

진공관형 태양열 집열기 히트파이프 작동유체에 따른 열성능 연구 (Experimental Study on Thermal Performance of Various Heat Pipe Working Fluid for Evacuated Tubular Solar Collector)

  • 주홍진;곽희열;김정배;김종보
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.70-75
    • /
    • 2007
  • This study was carried out to compare the thermal performance and operating characteristics of evacuated tubular solar collector(ETSC) with different working fluid. The evacuated tubular solar collectors with different working fluid of heat pipe were investigated in the same operating condition for a indoor experiment equipment. First, the result of working fluid with Water showed that $F_R({\tau}{\alpha})$ was 0.6636 and $F_{R}U_{L}$ was -1.8457. Second, Ethanol showed that $F_R({\tau}{\alpha})$ was 0.6147 and $F_{R}U_{L}$ was -0.6365. Third, Flutec-pp9 showed that $F_R({\tau}{\alpha})$ was 0.515 and $F_{R}U_{L}$ was -3.2313. Finally MA's showed that $F_R({\tau}{\alpha})$ was 0.6572 and $F_{R}U_{L}$ was -2.0086.

  • PDF

Simulation and Model Validation of a Parabolic Trough Solar Collector for Water Heating

  • Euh, Seung-Hee;Kim, Dae Hyun
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.17-26
    • /
    • 2013
  • The aim of this study is to analyze the performance of a parabolic trough solar collector (PTC) for water heating and to validate the model performance. The simulated model was compared, calibrated and verified with the experimental results. RMSE (Root mean square error) was used to calibrate the convective heat transfer coefficient between the absorber pipe and the ambient air which was the main factor affecting the heat transfer associated with the PTC. The calibrated model was better fitted with the experimental model. The maximum, minimum and mean deviation between the measured and predicted water temperatures differed only $0.81^{\circ}C$, $0.09^{\circ}C$ and $0.31^{\circ}C$ respectively in the calibrated model. RMSE values were decreased from 0.5389 to 0.4910, 0.0134 to 0.0125 and R-squared was increased from 0.9955 to 0.9956 after calibration. The temperature of water was increased from $33.7^{\circ}C$ to $48^{\circ}C$ in 12hour test. The thermal efficiency of the collector was calculated to be 55%. The calibrated model showed good agreement with the experimental data for model validation.

병영시설의 태양열급탕시스템에 관한 연구 (A Study on the Solar Water Heating System in the Military Facilities)

  • 김두천;서진석
    • 대한설비공학회지:설비저널
    • /
    • 제11권4호
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF

반온실형(半溫室型) 제습(除濕).태양열(太陽熱) 목재(木材)드라이어의 일사량(日射量)과 열효율분석(熱效率分析)에 관(關)한 연구(硏究) (Analysis of Solar Radiation and Heat-Efficiency in Semi-Greenhouse Type Solar-Dehumidification Lumber Dryer)

  • 이형우
    • 태양에너지
    • /
    • 제9권3호
    • /
    • pp.3-12
    • /
    • 1989
  • Semi-greenhouse type solar-dehumidification drying of oak was carried out to investigate the possibility to dry wood using solar energy in Korea. The energy balance equation was set up, considering all the energy requirements, and the solar radiation was calculated to analyze the efficiencies of solar dryer with and without the dehumidifier. The average temperature inside dryer and collector rose up to $52^{\circ}C$ and $70^{\circ}C$, respectively. The average daily total beam, diffuse, and ground-reflected radiations were 7.27MJ, 8.70MJ, and 0.33MJ on the roof and 2.08MJ, 4.84MJ, and 5.37MJ on the south wall collector, respectively. Heat efficiency of solar dryer was 14.04% with dehumidifier and 13.13% without dehumidifier. The energy required to remove 1g of water from wood was 0.0289MJ/g in solar-dehumidification drying and 0.0310 MJ/g in semi-greenhouse type solar drying.

  • PDF

지열시스템이 포함된 빌딩마이크로그리드 시스템의 에너지성능평가 및 경제성분석 (Economic Evaluation of Building Micro-Grid Including Geothermal Energy System in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.273-277
    • /
    • 2009
  • This paper presents a basic energy performance data of micro gas turbine, Renewable Energy(BIPV and Solar Collector System, geothermal system) and a hybrid energy system(geothermal system and microturbine) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently, the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. Finally, in energy performance aspect, Micro gas turbine system and hybrid energy system were high-efficiency system in hospital building. Hybrid energy system also give us a powerful alternative energy system economically.

  • PDF

Deinking of ONP with Cellulolytic Enzymes and Synthetic Collecter in Alkaline pH

  • Yoon, Kyong-Dong;Eom, Tae-Jin
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.451-454
    • /
    • 2006
  • This paper presents an overview of ONP deinking efficiency with cellulolytic enzymes and synthetic collector in alkaline pH. Deinking is a series of unit operations designed to detach ink from cellulose fibers and separate the dispersed ink from the pulp slurry. Deinking chemicals are process aids that enable expensive mill equipment used in these unit operations to operate more efficiently - often much more efficiently. We propose the blended deinking agent with cellulolutic enzymes and synthetic collector in deinking pulp of conventional alkaline method. The deinking efficiency of old news print in alkaline pH was enhanced with enzyme treatments. The brightness of deinked pulp was increased with less residual ink particles and yield of enzymatic deinked pulp was improved compared to the deinked pulp of conventional alkaline method.

  • PDF

개인용(個人用)컴퓨터를 이용(利用)한 외부집열판형(外部集熱板型) 제습태양열(除濕太陽熱) 목재건조(木材乾燥)의 자동화(自動化)에 관한 연구(硏究) (A Study on the automation of external collector type solar-dehumidification drying of wood using a personal computer)

  • 이형우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제20권2호
    • /
    • pp.23-30
    • /
    • 1992
  • An experimental external external collector type, solar dehumidification dryer was retrofitted with a simple computer-based control system. Solar, solar-dehumidification, and air-drying of 3cm-thick douglas-fir were carried out to investigate the drying-conditions and characteristics of this system, and to analyze the energy efficiencies of each drying met hods in summer. The drying rate of solar-dehumidification was 12%/day, which was about 2 times and 3 times faster than that of solar-and air-drying, respectively. The amount of diurnal temperature fluctuation inside the solar-dryer was greatly reduced and the energy efficiency was enhanced from 25% to 60% by the dehumidifier.

  • PDF