• 제목/요약/키워드: collector efficiency

검색결과 326건 처리시간 0.018초

이중투과체 및 VIP복합 단열재 적용 평판 집열기의 성능 향상에 대한 연구 (Research on Improvement of Efficiency in Flat Plate Solar Collector by Using Double-Wall Glazing and VIP Insulation)

  • 이두호;장한빈;김용학;도규형;이광섭;류남진
    • 설비공학논문집
    • /
    • 제28권11호
    • /
    • pp.458-465
    • /
    • 2016
  • The purpose of this research is to improve the thermal effiency of solar collector and to quantitatively analyze its performance. Solar thermal systems have been limited to water heating systems mainly using low-temperature range. However, through diverse developments, the application has been extended to medium- and high-temperature fields such as solar heating, solar air conditioning, and solar thermal industrial process. Among the diverse research, this research is specially focusing on enhancement of the thermal performance by minimizing the heat loss coefficient of flat plate solar collectors. In order to do it, a front-side glazing material and a back-side insulation material with high insulated structure is proposed and based on computational analysis, the performance of energy collecting volume of the proposed solar collector is analyzed. The research shows that the proposed structure has the excellent performance at medium- and high-temperature range. therefore, it is expected that the proposed structure can easily replace existing technologies.

이중 진공관형 태양열 집열기의 집열관 내부 형상과 운전 조건이 성능 변화에 미치는 영향 (Effects of Absorber Tube Shape and Operating Conditions on Thermal Performance of All-Glass Evacuated Tube Solar Collectors)

  • 최은용;김용;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제25권1호
    • /
    • pp.19-25
    • /
    • 2005
  • All-glass evacuated tube solar collectors consist of glass evacuated tubes and absorber tubes. Solar thermal energy from the sun is transferred to the working fluid through the glass evacuated tube and the absorber tube. Several collectors which have different absorber tubes are tested to find the effects of the absorber tube shapes and the operating conditions such as the incident heat flux and the flow rate. As the results, the efficiency of the collector which has a finned tube U tube is about $2{\sim}5%$ higher than that of the others in all cases on an average. And the collector has a finned U tube has the highest efficiency at the high flow rate and the low incident heat flux. In this condition, the outlet mean temperature is low and the heat loss becomes small. Also, it is known that the fin effect is greater than the shade effect.

병원건물의 스마트그리드시스템의 에너지절약평가 및 경제성분석 (Economic Analysis and Energy Saving Evaluation for Smart Grid System of Hospital Building)

  • 홍원표
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.129-139
    • /
    • 2010
  • 본 논문은 대형 병원 건물에 신재생에너지 및 열병합시스템을 설치하였을 경우 에너지 성능해석 및 경제성평가를 도출한 것이다. 태양광, 태양열, 지열, 마이크로터빈 및 마이크로터빈과 지열을 복합한 하이브리드 에너지시스템에 대하여 각각 분석하였다. 분석결과 지열 및 마이크로터빈 시스템이 비교적 양호한 결과를 얻었으며 특히 하이브리드시스템으로 운전하는 경우 병동부의 냉난방공급이 가능하고 경제성평가에서도 매우 좋은 결과를 나타냈다. 이는 빌딩 스마트 그리드시스템의 에너지해석 및 경제성평가 방법을 통한 시스템 구축에 필수적인 자료 활용할 수 있다.

An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector

  • Rokhman, Fatkhur;Hong, Boo-Pyo;You, Jin-Kwang;Yoon, Jung-In;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.360-363
    • /
    • 2012
  • A solar air heating has low efficiency compared with the solar water heating because the heat capacity of the air is small. The heat received by solar collector plate is not fully transferred to the air and then a part of them became the losses to the environment through conduction and convection process. This research is focusing on a design of better combined multi-purposed system suggested by us and aims to secure the more efficient solar energy utilization by combining the hot water and air heating system. The result in this paper has shown that the proposed design has better thermal performance than that of the common design. Furthermore, it was found that the performance of the combined air - water heating system increases the efficiency from 30% to 35%-40%.

  • PDF

심해저 망간단괴 집광기 채집장치의 설계평가 (Design Evaluation of Pickup Device Collecting Deep-Sea-Manganese Nodules)

  • 최종수;이태희;홍섭;심재용
    • 한국정밀공학회지
    • /
    • 제15권3호
    • /
    • pp.68-74
    • /
    • 1998
  • Performance and efficiency of deep seabed collector is a primary factor for feasibility of commercial deep ocean mining. The efficiency of manganese nodules collector depends on vehicle mobility relative to undulating seafloor and is attributed pickup head to keep altitude and elevation of it against seafloor. For this reason, motion control of pickup head relative to the changing deep-sea topography and other disturbances is of particular importance in design of pickup device. The concept of design axiom is applied to a pickup device of hybrid type in order to evaluate the concept design. Kinematic analysis conducted in absolute Cartesian coordinates gives position, velocity, and acceleration of the hydraulic cylinders which enable the pickup head to keep the preset optimal distance from seafloor. Inverse dynamic analysis provides the driving forces of hydraulic cylinders and the reaction forces at each joint. Design sensitivity analysis is performed in order to investigate the effects of possible design variables on the change of the maximum strokes of hydraulic cylinders. The direct differentiation method is used to obtain the design sensitivity coefficients.

  • PDF

RETScreen 모델이용 태양열온수시스템 초기설계단계 설계용량 최적화기법의 TRNSYS 모델과의 비교분석 (Comparative Study on Size Optimization of a Solar Water Heating System in the Early Design Phase Using a RETScreen Model with TRNSYS Model Optimization)

  • 이경호
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.693-699
    • /
    • 2013
  • This paper describes a method for size optimization of the major design variables for solar water heating systems at the stage of concept design. The widely used RETScreen simulation tool was used for optimization. Currently, the RETScreen tool itself does not provide a function for optimization of the design parameters. In this study, an optimizer was combined with the software. A comparative study was performed to evaluate the RETScreen-based approach with the case study of a solar heating system in an office building. The optimized results using the RETScreen model were compared to previously published results with the TRNSYS model. The objective function of the optimization is the life-cycle cost of the system. The optimized design results from the RETScreen model showed good agreement with the optimized TRNSYS results for the solar collector area and storage volume, but presented a slight difference for the collector slope angle in terms of the converged direction of the solutions. The energy cost, life-cycle cost, and thermal performance regarding collector efficiency, system efficiency, and solar fraction were compared as well, and the RETScreen model showed good agreement with the TRNSYS model for the conditions of the base case and optimized design.

건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구 (A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application)

  • 민성혜;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

나선유로에 의한 태양열 축열조 성층화 촉진(제1보 실증실험) (Enhancement of Stratification for Solar Water Storage Tank with Spiral Jacket and Coil(Part 1:Verification Experiment))

  • 권재욱;홍희기
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.336-342
    • /
    • 2012
  • Large-scale active solar heat systems are generally using heat exchanger between collector and storage tank loops to prevent damage by freezing. It is difficult to maintain stratification in a storage tank in the system owing to greater flow rate enhancing heat transfer. In the previous study, we introduced a spiral-jacketed storage tank and obtained good results to keep system performance of general level without better stratification. We added a scroll-shaped heat exchanger coil on the upper part in the spiral-jacketed storage tank. As a result of the experiment, it was verified that degree of stratification of the new type storage tank is higher than that of the previous one with a possibility of better collector efficiency and solar fraction.

지역별 기상조건과 급수온도에 따른 태양열 온수공급 시스템 성능에 관한 연구 (A Study on Performance of Solar Thermal System for Domestic Hot Water According to the Weather Conditions and Feedwater Temperatures at Different Locations in Korea)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.41-54
    • /
    • 2019
  • The purpose of this study is to analyze the performance of solar thermal system according to regional weather conditions and feedwater temperature. The performance analysis of the system was carried out for the annual and winter periods in terms of solar fraction, collector efficiency and it's optimal degree. The system is simulated using TRNSYS program for 6 cities, Seoul, Incheon, Gangneung, Mokpo, Gwangju, and Ulsan. Simulation results prove that the solar fraction of the system varies greatly from region to region, depending on weather conditions and feedwater temperatures. Monthly average solar fraction for winter season from November to February, a time when heat energy is most required, indicated that the highest is 73.6% in Gangnueng and the lowest is 56.9% in Seoul. This is about 30% relative difference between the two cities. On the other hand, the collector efficiency of the system for all six cities was analyzed in the range between 40% and 42%, indicating small difference compare to the solar fraction. The annual average solar fraction is rated the highest at 40 collector degree, while monthly average solar fraction during winter season is rated at 60 degree.

비금속 공기식 집열기의 이론 분석 및 성능실험 (Theoretical & Experimental Study on the Air-Type Nonmetallic Collectors.)

  • 이동원;이종호
    • 태양에너지
    • /
    • 제6권1호
    • /
    • pp.77-86
    • /
    • 1986
  • In this study, theoretical & Experiemental Analysis on three different air type solar collectors (One of metallic material: AI, two of non-metallic materials; GIWA & Slate) are performed. The results of three different collectors show the similiar performance in spite of different absorber material. The results of experiment are coincided with the theoretical results, and thus it is possible to estimate the performance of collector for the other experiment measuring variables. As a result, the thermal conductivity has no influence on the collector efficiency, because air, heat transfer medium, flows through over the whole surface of absorber plate.

  • PDF