• Title/Summary/Keyword: collecting rate

Search Result 400, Processing Time 0.024 seconds

Characterizations of a Cold Trap System for the Process Stabilization of Al2O3 by ALD Equipment (ALD 장비의 Al2O3 공정 안정화를 위한 저온 트랩 장치의 특성 평가)

  • Yong Hyeok Seo;Won Woo Lee;In Hwan Kim;Ji Eun Han;Yeon Ju Lee;Che Hoo Cho;Yongmin Jeon;Eou-Sik Cho;Sang Jik Kwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.92-96
    • /
    • 2024
  • The application of the technology for forming Al2O3 thin films using ALD(atomic layer deposition) method is rapidly increasing in the semiconductor and display fields. In order to increase the efficiency of the ALD process in a mass production line, metallic by-products generated from the ALD process chamber must be effectively collected. By collecting by-products flowing out of the chamber with a cold trap device before they go to the vacuum pump, damage to the vacuum pump can be prevented and the work room can be maintained stably, resulting in increased process flow rate. In this study, a cold trap was installed between the ALD process chamber and the dry pump to measure and analyze by-products generated during the Al2O3 thin film deposition process. As a result, it was confirmed that Al and O elements were discharged, and the collection forms were two types: bulk and powder. And the binding energy peaked at 73.7 ~ 74.3 eV, the binding energy of Al 2p, and 530.7 eV, the binding energy of O 1s, indicating that the binding structure was Al-O.

  • PDF

Renal Anomalies in Children with Turner Syndrome (Turner 증후군 환자에서 신기형에 관한 연구)

  • Kim, Ji Young;Hong, Sun Young;Park, Young Mi;Park, Yong Hoon;Chung, Woo Yeong
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.7
    • /
    • pp.891-895
    • /
    • 2002
  • Purpose : The prevalence of renal anomalies in Turner syndrome(TS) has been reported to vary from 33% to 60%. The purpose of this study was to clarify the true incidence of renal malformations in Korean TS. Methods : We evaluated 33 patients with Turner syndrome diagnosed by karyotype in Inje University Busan Paik hospital and Youngnam University from January 1995. Intravenous pyelography(IVP) was performed on all patients; abdominal ultrasonography and 99mTc-DMSA renal scan were performed on some. Cytogenetic analysis was performed on all patients with peripheral blood lymphocytes. Results : Of the total 33 patients, the karyotype showed 45, X in 18(54.5%) patients, mosaicism in 11(33.3%) patients and structural aberration in 4(12.2%) patients. The overall incidence of renal anomalies was 36.4%. The renal anomalies included four cases of horeshoe kidney, six cases of abnormal renal collecting system one case of single kidney and one case of malrotation. The incidence of renal anomalies in 45, X karotype(44.4%) showed a higher rate than that of mosaicism and structural aberration(26.7%), but there is no statistical significance. Conclusion : The incidence of renal anomalies in Korean TS reveals 36.4%. This rate is similar to other foreign TS studies. We recommend that renal ultrasonography or IVP for investigation of renal anomalies should be done as a screening procedure for the better quality of life in patients with TS.

Effect of Treatments of Post-Epicotyl grafting on the Survival Percentage and Growth in Walnut Trees(Juglans sinensis Dode) (호도나무 유경접목 후 처리가 활착율 및 생장에 미치는 영향)

  • Lee, Uk;Lee, Moon-Ho;Jung, Myung-Suk;Byun, Kwang-Ok;Hyun, Jung-Oh;Kwon, Yong-Hee
    • Korean Journal of Plant Resources
    • /
    • v.21 no.1
    • /
    • pp.36-40
    • /
    • 2008
  • To product grafts and construct its spread-system effectively, this study was carried out to investigate into effects on the survival percentage and growth in walnut trees(Juglans sinensis Dode) according to transplanting type and post-epicotyl grafting treatment. In the average survival percentage of the grafting according to post-epicotyl grafting transplanting type, TPGB1(transplanting in grafting bed) showing 89.02% was highest. Also, the survival percentage was different from appropriate temperature and humidity within treatment. As a result of the average survival percentage of the grafting by species, KWN-3 having 81.59% was highest with high survival percentage of total treatment in general. In addition, it is concluded that the nutrition condition of scions and collecting parts are strongly related to survival percentage on having significantly difference of its survival percentage by species. The growth rate of the survival grafts by transplanting type after grafting revealed that all of the investigation items(height and diameter growth of grafts, diameter growth of scions and etc.) resulted in same trend. TPGB1 having the highest tree height growth, 15.97cm($2.0{\sim}59.0cm$), showed the highest growth on diameter growth of shoots, 7.55mm($1.65{\sim}14.71mm$), and scions, 8.12mm($1.82{\sim}13.58mm$), as well. In the growth of each treatment according to different developing parts of shoots in grafts, the lateral bud, 12.05cm, was much superior to the terminal bud,9.57cm, on only graft height growth. However, the survival rate according to collecting parts of scions and developing parts of shoots with same treatment was not different with among-species.

Comparison of Thermal Insulation of Multi-Layer Thermal Screens for Greenhouse: Results of Hot-Box Test (온실용 다겹보온자재의 보온성 비교 -Hot box 시험 결과를 중심으로-)

  • Yun, Sung-Wook;Lee, Si-Young;Kang, Dong-Hyeon;Son, Jinkwan;Park, Min-Jung;Kim, Hee-Tae;Choi, Duk-Kyu
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.255-264
    • /
    • 2019
  • In this study, we conducted the hot box tests to compare the changes in thermal insulation for the four types of multi-layer thermal screens by the used period after collecting them from the greenhouses in the field when they were replaced at the end of their usage. The main materials for these four types of multi-layer thermal screens were matt georgette, non-woven fabrics, polyethylene (PE) foam, chemical cotton, etc. These materials were differently combined for each multi-layer thermal screen. We built specimens ($70{\times}70cm$) for each of these multi-layer thermal screens and measured the temperature descending rate, heat transmission coefficient, and thermal resistance for each specimen through the hot box tests. With regard to the material combinations of multi-layer thermal screens, thermal insulation can be increased by applying a multi-layered PE foam. However, it is considered that the multi-layered PE foam significantly less contributes to heat-retaining than chemical wool that forms an air-insulating layer inside multi-layer thermal screens. For the suitable heat-retaining performance of multi-layer thermal screens, basically, materials with the function of forming an air-insulating layer such as chemical cotton should be contained in multi-layer thermal screens. The temperature descending rate, heat transmission coefficient, and thermal resistance of multi-layer thermal screens were appropriately measured through the hot box tests designed in this study. However, in this study, we took into consideration only the four kinds of multi-layer thermal screens due to difficulties in collecting used multi-layer thermal screens. This is the results obtained with relatively few examples and it is the limit of this study. In the future, more cases should be investigated and supplemented through related research.

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

A Study on the Mothers' Knowledge and Practice about the Infant Weaning Diet (영유아 어머니의 이유식에 대한 지식정도 및 실태조사)

  • Kim, Mi-Sook;Choi, Kyung-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.7 no.1
    • /
    • pp.38-53
    • /
    • 2001
  • The main purpose of this study was to present the basic materials that help the nursing of the infants and consultation of childcare by examinating the knowledge and practice of the mothers about the weaning diet. The data for this study was collected from 205 mothers with infants(6-36 months) who visited two hospitals or one university hospital in Seoul, who were living in one apartment Suwon area between July. 7. and September 10, 2000. The 57 questionnaires were used for collecting the data and SAS program was used to analyse the data. The results are as follows. 1. The items of low score in the result of the knowledge data were as follows. [Initial weaning time, the important nutritional problem in infant, considering factor during feeding, the relation of proper weaning food & age, the time of used by cup, to apply of proper spicies in weaning food, the time of completing weaning, the time of stopping weaning at abnormal sign, and the inappopriate reason of dry mixed powdered food (Sunsik) as a weaning food.] 2. Higher educated mothers presented more high score than lower educated mothers in the knowledge about the weaning. (p<0.05) 3. Before the weaning, more mothers were using the commercial milk (51.2%) than the breast milk (13.2%). 4. Mothers get the knowledge about the weaning from the infants care book of cook books(26.4%). 68% of mothers had not received any consulting service with regard to the weaning, 10.2% of them consulted Pediatrician about the weaning and 0.5% of them with nurse. 5. Most mothers began supplymentary food, from four to six months (65.4%). the ratio was about the same as the ratio of mothers who knEw the appropriate time for the introduction of supplymentary food(83.2%) 6. The main solid food was commercial food, not home-prepared food. 7. Higher educated mothers used home-prepared weaning food more often than lower educated mothers(P<0.05). 8. The used rate by spoon was 57.4%, but the rate of mother's knowledge data was 95.0%. 9. The time of completing the weaning was in 12-18 months(53.8%). It is similar to the mother's knowledge data(52.7%) Conclusion ; According to knowledge data, it turns out that most mothers know moderatly about the weaning (everage 60/100). However their knowledge and practice on the methods & procedures on the weaning were inadquate. Especially, most mothers did not consult with those qualification about the weaning. Therefore, the role of the nurse as a provider of information on the weaning should be emphasized with varied educational programs in many health care center.

  • PDF

Present Status of Soil Contamination Facilities (특정토양오염관리대상시설의 실태에 관한 고찰)

  • Kim, Ki-Ho;Park, Jae-Soo;Kim, Hae-Keum;Choi, Sang-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.287-292
    • /
    • 2012
  • This study was to build the database by collecting the results of legal leak test and self-test conducted by the owners of soil contamination facilities at soil-related specialized agency to grip objective status on soil contamination facilities and evaluate classification results. The results of the study showed that the unsuitable rate of business unit is 53.6%, the business with leak that could cause actual pollution is 25.7%, the unsuitable rate of the voluntary self-test is 57.3%, that of the compulsory inspection is 17.2% depending on the test motivation, that of the direct-test is 58.9%, and that of the indirect-test is 22.5% depending on the test methods. There was a significant difference between the test motivation conducted and the test methods applied. From the results of the unsuitable reasons obtained we could assume that about 20% of the whole target tanks became potential sources with natural defects occurred when such tanks were made, and 2.2% of the whole tankers examined that persisting period was caused by progressing corrosion below the minimum thickness.

An Application of Software Reliability Estimation Model on Weapon System (국내 무기체계 분야의 소프트웨어 신뢰성 추정 모델 적용 사례)

  • Bak, Da-Un
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.178-186
    • /
    • 2020
  • In the domain of Korean weapon system development, issues about software reliability have become crucial factors when developing a weapon system. There is a process required for weapon system software development and management that includes certain activities required to improve the reliability of software. However, these activities are biased toward static and dynamic analyses of source code and do not include activities necessarily required by the international standard. IEEE std. 1633-2016 defines a process for software reliability engineering and describes software reliability estimation as an essential activity in the process. Software reliability estimation means that collecting defective data during the test and estimating software reliability by using the statistical model. Based on the estimated model, developers could estimate the failure rate and make comparisons with the objective failure rate to determine termination of the test. In this study, we collected defective data and applied reliability estimation models to analyze software reliability in the development of a weapon system. To achieve objective software reliability, we continuously tested our software and quantitatively calculated software reliability. Through the research, we hope that efforts to include activities described by the international standard will be carried out in the domain of Korean weapon system development.

Evaluation of the Relationship between Meteorological Drought and Agricultural Drought of Geum River Basin During 2014~2016 (금강유역 2014~2016년 기상학적 가뭄과 농업가뭄간의 상관성 평가)

  • Lee, Ji Wan;Kim, Kyoung-Ho;Kim, Sehoon;Woo, Soyoung;Kim, Seong Joon
    • Journal of Wetlands Research
    • /
    • v.21 no.spc
    • /
    • pp.80-89
    • /
    • 2019
  • The purpose of this study is to analyze the relationship between SPI (Standardized Precipitation Index) meteorological drought and RDI (Reservoir Drought Index) agricultural drought for Geum river basin. Drought Indices was calculated by collecting data of precipitation and agricultural reservoir water storage rate from 2014 to 2016. To evaluated the correlation between meteorological and agricultural drought, the Pearson correlation and the Receiver Operation Characteristic (ROC) analysis were conducted to evaluate the correlation between meteorological and agricultural droughts. The SPI-6 and RDI showed the highest relationship with Pearson coefficient 0.606 and ROC hit rates 0.722 respectively, and the spatial occurrence patterns of drought using overlapped SPI-6 and RDI, the big differences between the 2 indices were occurred in the upstream areas of Miho stream and Nonsan stream from August to October 2015. The analysis using reservoirs specifications for areas where reservoir droughts occurred was conducted, and the areas showing severe drought of RDI were the reservoir areas having relatively small value of basin magnifying power (BMP). This means that a reservoir has the reaction capability for agricultural drought mainly depending on the reservoir BMP.