• Title/Summary/Keyword: cold wind

Search Result 537, Processing Time 0.027 seconds

The investigation of Literature about cause, Symptom, theory of treatment prescription of 'Han-So'( ) = cough caused by cold-evil (한수(寒嗽)의 원인(原因) 증상(症狀) 치료처방(治法處方)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Park, Dong-Il;Jeong, Seung-Gi;Lee, Hyeong-Gu
    • The Journal of Internal Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.157-164
    • /
    • 1990
  • The results of the investigation of literature were summerized as follows ; 1. The factors of cough caused by cold-evil were revealed as the following order cold weather and drinking cold water, the disease caused by exoganous cold-evil and wind-evil, Lung affected by cold-evil, both spleen and lung avoided by cold-evil 2. The symptom of cough caused by cold-evil were appeared as follows. Tense pulse, Tense chest-voice hoarsness, intolerance to cold, fever anhidrosis fidgetiness nonthirst cough caused by cold-evil 3. The treatment of cough caused by cold-evil were showeding as follws Cleaning away cold-evil eliminating the pholegm, dispelling exogenous evils, making warm-heat 4. The prescription of 'Han So' were used frequently as the orders followed

  • PDF

A Study on the Effectiveness of Wind Corridor Construction forImproving Urban Thermal Environment: A Case study of Changwon, South Korea (도시 열환경 개선을 위한 취약지역 선정 및 바람길 조성 방안: 창원시를 대상으로)

  • Kim, Jong-Sung;Kang, Jung-Eun
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.4
    • /
    • pp.187-202
    • /
    • 2021
  • This study examined the effectiveness of wind corridor construction by analyzing the thermal environment, cold air generation, ventilation, and geographical characteristics to improve urban thermal environment and establish the basis for specialized strategy in Changwon-si, Gyeongsangnam-do. Using spatial analysis and remote sensing techniques, surface temperature, land cover and land use, wind field, and slope were measured and through this, a wind corridor analysis model was constructed. As a result of the analysis as of 2020, Changwon-si generally has land cover characteristics that are advantageous for the generation of cold air, but the temperature in most urban areas is the highest, and the temperature in areas such as north Changwon area, Jinbukmyeon, Ung-dong, and Ungcheon-dong are relatively high. There was a typical trend of high average wind speed in mountain regions and low average wind speed in urban areas. Accordingly, the north Changwon area, the former Changwon downtown area, the Hogye-ri and Pyeongseong-ri areas, and the Changpo Bay area are derived as vulnerable areas to thermal environment, and various measures to reduce temperature and improve air quality that the inflow of cold air into the area considering the characteristics of each area and securing wind ventilation between the surrounding mountains, reservoirs, and park areas were proposed.

Wind Corridor Analysis and Climate Evaluation with Biotop Map and Airborne LiDAR Data (비오톱 지도와 항공라이다 자료를 이용한 바람통로 분석 및 기후평가)

  • Kim, Yeon-Mee;An, Seung-Man;Moon, Soo-Young;Kim, Hyeon-Soo;Jang, Dae-Hee
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.6
    • /
    • pp.148-160
    • /
    • 2012
  • The main purpose of this paper is to deliver a climate analysis and evaluation method based on GIS by using airborne LiDAR data and Biotop type map and to provide spatial information of climate analysis and evaluation based on Biotop type Map. At first stage, the area, slope, slope length, surface, wind corridor function and width, and obstacle factors were analyzed to obtain cold/fresh air production and wind corridor evaluation. In addition, climate evaluation was derived from those two results in the second stage. Airborne LiDAR data are useful in wind corridor analysis during the study. Correlation analysis results show that ColdAir_GRD grade was highly correlated with Surface_GRD (-0.967461139) and WindCorridor_ GRD was highly correlated with Function_GRD (-0.883883476) and Obstacle_GRD (-0.834057656). Climate Evaluation GRID was highly correlated with WindCorridor_GRD (0.927554516) than ColdAir_GRD (0.855051646). Visual validations of climate analysis and evaluation results were performed by using aerial ortho-photo image, which shows that the climate evaluation results were well related with in-situ condition. At the end, we applied climate analysis and evaluation by using Biotop map and airborne LiDAR data in Gwangmyung-Shiheung City, candidate for the Bogeumjari Housing District. The results show that the aerial percentile of the 1st Grade is 18.5%, 2nd Grade is 18.2%, 3rd Grade is 30.7%, 4th Grade is 25.2%, and 5th Grade is 7.4%. This study process provided both the spatial analysis and evaluation of climate information and statistics on behalf of each Biotop type.

A Study on the Wind Ventilation Forest Planning Techniques for Improving the Urban Environment - A Case Study of Daejeon Metropolitan City - (도시환경 개선을 위한 바람길숲 조성 계획기법 개발 연구 - 대전광역시를 사례로 -)

  • Han, Bong-Ho;Park, Seok-Cheol;Park, Soo-Young
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.51 no.2
    • /
    • pp.28-41
    • /
    • 2023
  • The objective of the study was to develop an Urban Windway Forest Creation Planning Technique for the Improvement of the Urban Environment using the case of Daejeon Metropolitan City. Through a spatial analysis of fine dust and heat waves, a basin zone, in which the concentration was relatively serious, was derived, and an area with the potential of cold air flow was selected as the target area for the windway forest development by analyzing the climate and winds in the relevant zone. Extreme fine dust areas included the areas of the Daejeon Industrial Complex Regeneration Business District in Daedeok-gu and Daedeok Techno Valley in Yuseong-gu. Heat wave areas included the areas of Daedeok industrial Complex in Moksang-dong, the Daejeon Industrial Complex Regeneration Business District in Daehwa-dong, and the high-density residential area in Ojeong-dong. As a result of measuring the wind speeds in Daejeon with an Automatic Weather System, the average wind speeds during the day and night were 0.1 to 1.7 m/s,, respectively. So, a plan of for a windway forest that smoothly induces the movement of cold air formed in outer forests at night is required. The fine dust/heat wave intensive management zones of Daejeon Metropolitan City were Daejeoncheon, Yudeungcheon, Gapcheon-Yudeungcheon, and Gapcheon. The windway forest formation plan case involved the old city center of Daejeon Metropolitan City among the four zones, the Gapcheon-Yudeungcheon area, in which the windway formation effect was presumed to be high. The Gapcheon-Yudeungcheon area is a downtown area that benefits from the cold and fresh air generated on Mt. Gyejok and Mt. Wuseong, which are outer forests. Accordingly, the windway forest was planned to spread the cold air to the city center by connecting the cold air generated in the Seosa-myeon forest of Mt. Gyejok and the Namsa-myeon forest of Mt. Wuseong through Gapcheon, Yudeungcheon, and street forests. After selecting the target area for the wind ventilation forest, a climate map and wind formation function evaluation map were prepared for the area, the status of variation wind profiles (night), the status of fine dust generation, and the surface temperature distribution status were grasped in detail. The wind ventilation forest planning concept and detailed target sites by type were identified through this. In addition, a detailed action plan was established according to the direction of creation and setting of the direction of creation for each type of wind ventilation forest.

Development of Dome-Type Cold Storage Facility Using 3-D CFD Simulation (3차원 CFD 시뮬레이션을 이용한 돔형 저온저장고 개발)

  • 양길모;고학균;홍지향
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.35-44
    • /
    • 2003
  • This study was conducted to develop proper model for cold storage facility that could of for uniform heat movement and air movement f3r green grocery and improve improper design of the existing container-type cold storage facility. For that reason, new model(dome-type) cold storage facility was developed using 3-D CFD(computational fluid dynamics) simulation. The size was 6m${\times}$6m${\times}$5m. Its size and configuration were same to simulation model. Unit cooler was designed to send cold air in 4 side ways. A dome-type cold storage facility showed uniform distributions of air temperature and velocity because cold air was forced to move down along the ceiling and the wall and then circulated to the unit cooler from the central part of the floor. Dome-type cold storage facility also showed by low wind velocity, below 1 m/s that could minimized cold damage and quality deterioration.

A Study on Sinusitis in Pediatric Patients : the Analysis of Age and the Classification of Korean Medical Clinical Type (한방병원에 내원한 부비동염 환아의 연령 분석 및 임상 유형 분류)

  • Lee, Sun Jung;Kang, Kyung Ha;Park, Eun Jeong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.9-21
    • /
    • 2016
  • Objectives The purpose of this study is to analyze sinusitis patients who visited the department of pediatrics, OO Korean medicine hospital by using their age and to classify the clinical type by Korean medical theory. Methods The study was conducted based on 178 cases that consisted of sinusitis patients (from 1 to 15 years old) who visited OO Korean medicine hospital from March 2014 to March 2015. We analyzed the age of patients and classified them by the clinical type by reviewing patient's charts. After that, we compared the results with the results of previous studies. Results and Conclusions 178 Patients were studied. 2-years-age group was 19.7% of the study group which was higher than that of previous studies. The Lung-Kidney Yin Deficiency (肺腎陰虛) group was 33.1%, Wind-Heat (風熱) group was 29.8% and the Wind-Cold (風寒) group 18.5%, Spleen-Lung Qi Deficiency (脾肺氣虛) group was 15.7% and the Heart-Spleen Qi Deficiency (心脾氣虛) group was 2.8% of the study group. Children are full of Yang but lack of Yin (陽常有餘陰常不足) so they easily transform into heat and fire (化熱化火). The patients who had sinusitis were most likely to suffer from the common cold for more than a week, once a month. 45.1% of the people from the study group was suffered from common cold more than a week, and 43.8% of the people got common cold once a months. About 21.6 % and 18.3% of the people got common cold twice a month and once every 2 months, respectively. The remaining 15.7% got cold during the season changes.

Can we obtain sea-surface flow information from satellite scatterometer winds\ulcorner

  • Park, Kyung-Ae;Cornillon, Peter;Chung, Jong-Yul;Kim, Kuh
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.621-626
    • /
    • 2002
  • A satellite scatterometer is a microwave radar sensor used to measure the backscattering at a sea surface. This instrument transmits radar pulses to the sea surface and measure the radar energy reflected back towards the source. Changes in wind velocity make sea surface roughness change and then affect on backscattered power. This gives us information of sea surface wind speed. Directions of wind vectors are acquired by multiple, collocated, and nearly simultaneous measurements. It should be noted that the scatterometer observes not the wind directly but the wind stress vector relative to the surface current. This suggests the possibility that the satellite scatterometer winds can include the effect of the surface current. This study shows the evidence that scatterometer measure surface wind stress, not surface winds and presents the velocity structure of oceanic warm and cold eddies.

  • PDF

Experimental Study of the Effect on Cabin Thermal Comfort for Cold Storage Systems in Vehicles (축냉 시스템이 차 실내 열 쾌적성에 미치는 영향에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This paper presents the experimental study of cabin thermal comfort using a cold storage heat exchanger in a vehicle air-conditioning system. Recent vehicle-applied ISG functions for fuel economy and emission, but when vehicles stop, compressors in the air-conditioning system stop, and the cabin temperature sharply increases, making passengers feel thermal discomfort. This study conducts thermal comfort evaluation in the vehicle, which is applied to a cold storage system for the climate control wind tunnel test and the vehicle fleet road test with various airflow volume rates and ambient temperatures blowing to the cold storage heat exchanger. The experimental results, in the cold storage system, air discharge temperature is $3.1-4.2^{\circ}C$ lower than current air-conditioning system when the compressor stops and provides cold air for at least 38 extra seconds. In addition, the blowing airflow volume to the cold storage heat exchanger with various ambient temperature was examined for the control logic of the cold storage system, and in the results, the airflow volume rate is dominant over the outside temperature. For this study, a cold storage system is economically useful to keep the cabin at a thermally comfortable level during the short period when the engine stops in ISG vehicles.

Study on Rice Growing Environment Against Cold Sea Wind in Eastern Coastal Area of Korean Peninsula (동해안 냉해풍지역의 벼 생육환경 연구)

  • Kim, Jeong-Il;Lee, Ji-Yoon;Park, Dong-Soo;Park, No-Bong;Kwon, Oh-Deog;Chang, Jae-Ki;Lee, Ji-Hun;Kim, Sang-Yeol;Kang, Hang-Won
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.55 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • This study was conducted to analysis a major cause of rice yield reduction in 4 research points, 1, 2, 3, and 5km, from coastline in the East Sea. There were great changes of temperature in each research point, though the average temperature a day was no difference between each research point. Each temperature in 1, 2, and 3km research points was 8, 7, and $4^{\circ}C$ lower than in 5km when cold salty wind was generated due to cold pool. As it was close in coastline, its soil was abundant sand components, little silt and clay soil components and lacking in cation exchange capacity(CEC). And plant height became a smaller, heading date was delayed for 3~4 days, and dry weight was reduced. Also, it was to be down percent of fertile grain. As cultivation site was close in seaside, its decline was larger because of reduction of panicle number per hill. It was "Samdeogbyeo" that was variety adapted in cold salty wind, having yield potential more than 90% in 2km.

Management Planning of Wind Corridor based on Mountain for Improving Urban Climate Environment - A Case Study of the Nakdong Jeongmaek - (도시환경개선을 위한 산림 기반 바람길 관리 계획 - 낙동정맥을 사례로 -)

  • Uk-Je SUNG;Jeong-Min SON;Jeong-Hee EUM;Jin-Kyu MIN
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.21-40
    • /
    • 2023
  • This study analyzed the cold air characteristics of the Nakdong Jeongmaek, which is advantageous for the formation of cold air that can flow into the city, in order to suggest the wind ventilation corridor plans, which have recently been increasing interest as a way to improve the urban thermal environment. In addition, based on the watershed analysis, specific cold-air watershed areas were established and management plans were suggested to expand the cold air function of the Nakdong Jeongmaek. As a result of the analysis of cold air in the Nakdong Jeongaek, cold air was strongly generated in the northern forest of the Jeongamek, and flowed into nearby cities along the valley topography. On average, the speed of cold air was high in cities located to the east of the Jeongmaek, while the height of cold air layer was high in cities located to the west. By synthesizing these cold air characteristics and watershed analysis results, the cold-air watershed area was classified into 8 zones, And the plans were proposed to preserve and strengthen the temperature reduction of the Jeongmaek by designating the zones as 'Conservation area of Cold-air', 'Management area of Cold-air', and 'Intensive management area of Cold-air'. In addition, in order to verify the temperature reduction of cold air, the effect of night temperature reduction effect was compared with the cold air analysis using weather observation data. As a result, the temperature reduction of cold air was confirmed because the night temperature reduction was large at the observation station with strong cold air characteristics. This study is expected to be used as basic data in establishing a systematic preservation and management plan to expand the cold air function of the Nakdong Jeongmaek.