Permeability Evaluation of OPC and GGBFS Concrete with Cold Joint (콜드조인트를 가진 OPC 및 GGBFS 콘크리트의 투수성 평가)

  • Choi, Se-Jin;Kim, Seong-Jun;Moon, Jin-Man;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.435-441
    • /
    • 2015
  • Concrete, as a porous media, has permeability and it is considered as a major parameter for durability evaluation. Cold joint caused by delayed placing of concrete accelerates water permeation and intrusion of harmful ions. In the paper, concrete specimens containing GGBFS (Ground Granulated Blast Furnace Slag) and OPC (Ordinary Portland Cement) are prepared with cold joint section, and water permeability and water flow at the age of 91 days are measured for 2 weeks. Sound concrete with GGBFS shows decreased permeability to 89% for sound concrete with OPC and 0.86 of decreasing ratio is evaluated in GGBFS concrete with cold joint. Through WPT (Water Penetration Test), the effects of mineral admixture and cold joint on water permeability are evaluated, and variation in water behavior via cold joint is analyzed through probabilistic method as well.

Fresh and hardened properties of concrete containing cold bonded aggregates

  • Thomas, Job;B., Harilal
    • Advances in concrete construction
    • /
    • v.2 no.2
    • /
    • pp.77-89
    • /
    • 2014
  • The properties of fresh and hardened concrete made using three types of artificial cold bonded aggregates are determined. The properties, namely, slump, water absorption, compressive strength and splitting tensile strength of concrete containing artificial aggregate are reported. The variables considered are aggregate type and water-to-cement ratio. Three types of cold bonded aggregates are prepared using fly ash and quarry dust. The water-to-cement ratio of 0.35, 0.45, 0.55 and 0.65 is used. The test result indicates that artificial aggregates can be recommended for making the concrete up to a strength grade of 38 MPa. The use of quarry dust in the production of artificial aggregate mitigates environmental concerns on disposal problems of the dust. Hence, the alternate material proposed in this study is a green technology in concrete production.

A comparative experimental study on the mechanical properties of cast-in-place and precast concrete-frozen soil interfaces

  • Guo Zheng;Ke Xue;Jian Hu;Mingli Zhang;Desheng Li;Ping Yang;Jun Xie
    • Geomechanics and Engineering
    • /
    • v.36 no.2
    • /
    • pp.145-156
    • /
    • 2024
  • The mechanical properties of the concrete-frozen soil interface play a significant role in the stability and service performance of construction projects in cold regions. Current research mainly focuses on the precast concrete-frozen soil interface, with limited consideration for the more realistic cast-in-place concrete-frozen soil interface. The two construction methods result in completely different contact surface morphologies and exhibit significant differences in mechanical properties. Therefore, this study selects silty clay as the research object and conducts direct shear tests on the concrete-frozen soil interface under conditions of initial water content ranging from 12% to 24%, normal stress from 50 kPa to 300 kPa, and freezing temperature of -3℃. The results indicate that (1) both interface shear stress-displacement curves can be divided into three stages: rapid growth of shear stress, softening of shear stress after peak, and residual stability; (2) the peak strength of both interfaces increases initially and then decreases with an increase in water content, while residual strength is relatively less affected by water content; (3) peak strength and residual strength are linearly positively correlated with normal stress, and the strength of ice bonding is less affected by normal stress; (4) the mechanical properties of the cast-in-place concrete-frozen soil interface are significantly better than those of the precast concrete-frozen soil interface. However, when the water content is high, the former's mechanical performance deteriorates much more than the latter, leading to severe strength loss. Therefore, in practical engineering, cast-in-place concrete construction is preferred in cases of higher negative temperatures and lower water content, while precast concrete construction is considered in cases of lower negative temperatures and higher water content. This study provides reference for the construction of frozen soil-structure interface in cold regions and basic data support for improving the stability and service performance of cold region engineering.

Distortional buckling performance of cold-formed steel lightweight concrete composite columns

  • Yanchun Li;Aihong Han;Ruibo Li;Jihao Chen;Yanfen Xie;Jiaojiao Chen
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.675-688
    • /
    • 2024
  • Cold-formed steel (CFS) is prone to buckling failure under loading. Lightweight concrete (LC) made of lightweight aggregate has light weight and excellent thermal insulation performance. However, concrete is brittle in nature which is why different materials have been used to improve this inherent behavior of concrete. The distortional buckling (DB) performance of cold-formed steel-lightweight concrete (CFS-LC) composite columns was investigated in this paper. Firstly, the compressive strength test of foam concrete (FC) and ceramsite concrete (CC) was carried out. The performance of the CFS-LC members was investigated. The test results indicated that the concrete-filled can effectively control the DB of the members. Secondly, finite element (FE) models of each test specimen were developed and validated with the experimental tests followed by extensive parametric studies using numerical analysis based on the validated FE models. The results show that the thickness of the steel and the strength of the concrete-filled were the main factors on the DB and bearing capacity of the members. Finally, the bearing capacity of the test specimens was calculated by using current codes. The results showed that the design results of the AIJ-1997 specification were closer to the experimental and FE values, while other results of specifications were conservative.

An Experimental Study on the Strength in Mass-Concrete and Heat of Hydration (수화열과 메스콘크리트의 강도에 관한 실험적 연구)

  • 백민수;정근호;김종락;이영도;김영희;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.217-224
    • /
    • 1998
  • This study describes examinations made for the purpose of obtaining data for strength control of mass concrete in the cold season. The examination in outline of analysis of temperatures of mass concrete(corresponding to member thickness of 1m) and comparisons with water-cured specimens of various concrete specimens cured in sealed condition. As a result, it was found that mass concrete placed in the cold season, if strength is controlled based on 28-day age, is seen to require a strength correction factor.

  • PDF

Field Application of High Strength Concrete under Cold Weather Conditions (650kgf/$\textrm{cm}^2$ 고강도 콘크리트 한중 시공사례)

  • 정재동;노재호;한정호;조일호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.04a
    • /
    • pp.260-265
    • /
    • 1994
  • High strength concrete(65MPa) was used for construction of the bulk cement storage silo by using sliding form. This paper presents mix design, production, quality control and experience with field application of high strength concrete under cold weather conditions. It is shown to be possible to produce high strength concrete of compressive strength of 50~60 MPa by using high-range water reducer to lower w/c ratio with appropriate quality control.

  • PDF

A Study in Application and Manufacture Technique of Cold-Mix Cold-Laid Type Asphalt Concrete Using of Polymer Modified Asphal (개질 아스팔트를 이용한 상온아스콘 제조 및 실용화 연구)

  • 김영근;남궁연;박유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.627-634
    • /
    • 1997
  • This is the Study on Application and Manufacture Technique of Cold-Mix, Cold-Laid type Asphalt Concrete using of Polymer modified asphalt the could be constructed easily and economically on damaged road repaireless for seasons. The modified materials for this study are SBS(Styrene-Butadiene-Styrene). SBR (Styrene-Butadiene-Rubber) and PUR(Polyurethane). The Marshall stability and the value of flow and resistance in water stability degree according to the alternation types and weight percent of modified materials were compared and evaluated on this study. The results of the study show that PUR modified asphalt have improvement of over 150% Marshall stability in AI MS-14 standard and they are evaluated to have the easiness of storage and better working efficiency compared with other types of modified asphalt compound.

  • PDF

Evaluation of Chloride Penetration Resistance of Frost Concrete according to the water-cement ratio, during the Cold Wave (한파로 인한 초기 동해를 입은 콘크리트의 염해 저항성 평가)

  • Park, Dong-Cheon;Lee, Jun-Hae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.165-166
    • /
    • 2020
  • The climate on the Korean Peninsula has been warmed recently, abnormal weather conditions such as heat waves, cold waves, and tropical nights have been detected frequently. Precisely, the number of days with cold waves in the winter has increased, and rapid changes of temperature in the morning and afternoon have occurred frequently in the 2000s. Due to the previous phenomenons, this research is focused on evaluating the concrete's Chloride Penetration Resistance and Durability, and the difference of the resistance according to the W/C.

  • PDF

Quality Inspection for Cast-In-Place Concrete with the Device to Record Curing Temperature (양생온도 이력 기록장치를 이용한 현장타설 콘크리트의 품질검사)

  • Cho, Yeong-Kweon;Kim, Kwan-Ho;Kim, Meyong-Won;Lee, Jun-Gu;Yoo, Jung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.351-354
    • /
    • 2005
  • Quality of concrete required to achieve the desired levels of strength and durability depend on the effectiveness of the curing method. During cold weather, the concrete at the time of placement should be taken to prevent damage to concrete due to freezing. Since the cement-water reaction is exothermic by nature, the temperature within mass concrete can be quite high. The temperature control for massive sections should be taken more careful than for shallow sections. However, in the constructing hydraulic structures, the curing temperature control for concrete had been very difficult to be taken in a proper way because the conditions constructing them are poor and contractors are small enterprises. For several. reasons including above, Rural Research Institute has developed a device and program for recording curing temperature history in cold weather concrete and mass. As there are two major advantages of the device, namely cheapness and availability, this program and device has been recommended to the use of curing temperature control in cold weather concrete and mass.

  • PDF

A Study on the improvement of Strength delay according to Low Temperature of Cold Weather Concrete (한중콘크리트의 저온에 의한 강도지연 개선연구)

  • Lee, Sang-Soo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.51-59
    • /
    • 2012
  • The cold weather concrete poured in the winter season can cause the problem of the Due to recent high-rise building is made. In this research, the nominal mix of the early strength in concrete tried to be set through the mixing proportion experiment for each empirical variable and each component strength properties for the early strength improvement tries to be examined. In the cold weather concrete experiment, the cement and high early strength (type3) cement improving in OPC than OPC was excellent. The polycarboxylic acid based compound was exposed to be excellent in the intensity revelation properties. Because the using of the fly ash was disadvantageous it was excluded from this experiment. It showed the optimum temperature for the intensity revelation up over $12^{\circ}C$.

  • PDF