• Title/Summary/Keyword: cold water

Search Result 1,916, Processing Time 0.023 seconds

Treatment of surface water using cold plasma for domestic water supply

  • Nguyen, Dung Van;Ho, Phong Quoc;Pham, Toan Van;Nguyen, Tuyen Van;Kim, Lavane
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.412-417
    • /
    • 2019
  • This paper presents the results of using cold plasma to treat surface water for domestic use purpose. Experimental results showed that cold plasma was an effective method for destroying bacteria in water. After treatment with cold plasma, concentration of coliform and Escherichia coli dramatically reduced. Besides, cold plasma significantly removed water odor, increased dissolved oxygen and decreased the concentration of chemical oxygen demand. However, cold plasma significantly raised the concentration of nitrite and nitrate. Other disadvantages of treating with cold plasma were conductivity increase and pH reduction. Pretreatment steps of coagulation, flocculation, sedimentation and sand filtration followed by disinfection with cold plasma exhibited a high efficiency in surface water treatment. All parameters of surface water after treatment by using the prototype satisfied with the allowance standard of domestic water quality.

Estimation model of reasonable amount of domestic cold water and hot water supplies in apartment houses (공동주택의 적정 급수.급탕량 산정 모델)

  • 김성남;하태웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.758-765
    • /
    • 1999
  • The estimation of reasonable amount of domestic cold water and hot water supplies in apartment houses is very important for the economical design of domestic cold water and hot water supply system which include pumps, boilers, heat exchangers, and various water reservoirs. To suggest the model of predicting reasonable amount of domestic cold water and hot water supplies, residents and actual domestic cold water and hot water consumption have been investigated for 740 apartment houses in Seoul and Bun-Dang, Kyunggi-Do. The model is suggested as a function of exclusive area of the apartment house and results of the model show generally good agreement with published data.

  • PDF

Characteristics of Cooling Temperature of Cold Water Pipes Buried in the Wall of a Small Mobile Modular House (소형 이동식 모듈주택의 벽면에 냉수배관 매설에 의한 냉방온도 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.110-117
    • /
    • 2022
  • A chiller cooler absorbs the thermal energy of water to generate cold water and supplies the generated cold water to a cold water pipe buried in the wall of a small mobile modular house to greatly increase the cooling area. An attempt was made to reduce the required cooling time significantly. A small chiller cooler suitable for the cooling load of a small mobile modular house with an area less than 3.3 m2 was employed. When cooling is done during summer using a chiller cooler installed outdoors, heat absorption energy loss occurs in the cold water pipe owing to the high temperature. To address this, a study was conducted to reduce the endothermic energy loss significantly. As the mass flow rate of the cold water flowing inside the cold water pipe increased, the temperature decrease gradient of the cold water increased. From the start of the cooling operation, the air temperature of the small mobile modular house decreased linearly in proportion to the operation time. Furthermore, the temperature of the air inside the small mobile modular house decreased in proportion to the increase in the flow of water inside the cold water pipe.

A Study on Cooling Systems with Cold Water Panels in the Walls of Small Buildings (소형 건축 벽면의 냉수 패널에 의한 냉방시스템에 관한 연구)

  • Cho, Dong-Hyun;Jo, Myeong-Gi
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.20-26
    • /
    • 2019
  • This study was conducted on cooling systems in which, for the first time at home and abroad, cold water panels are embedded in the walls of small buildings for radiant cooling by heat absorption with cold water. In summer, cold water is circulated through cold water (chiller) circulation tubes embedded in three walls (two side walls and one rear wall) of a building to implement radiant cooling by the coldness of the water. From the results of this study, the experimental and theoretical natural convection heat transfer coefficients were relatively well-matched over the entire experimental range, thereby verifying the reliability of the experimental results. The surface temperature reduction rate of the walls in which cold water panels are embedded was large whereas that of the walls where no cold water panels are embedded was very small.

Irrigation water temperature and cold water damage of paddy (관개수온과 벼의 냉수피해)

  • 정상옥;오창준
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.14-21
    • /
    • 1998
  • In 1996, a cold-water damage occured in the paddy field at downstream of the Unmoon dam. To study the cause and the preventive measures of the cold-water damage a field study was performed during the growing season of 1997. Field measurements such as water temperatures at reservoir, irrigation canal and in the paddy field were made. As a result, there was no cold-water damage due to the right irrigation water management practice in 1997. The cold-water damage is passible to happen, however, and the preventive measures were provided.

  • PDF

A Study of Interrelationships between the Effect of the Upwelling Cold Water and Sea Breeze in the Southeastern Coast of the Korean Peninsula (한반도 동남연안지역의 냉수대 영향과 해풍의 상호관련성 연구)

  • Lee, Hwa-Woon;Ji, Hyo-Eun;Lee, Soon-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.481-492
    • /
    • 2009
  • The characteristic of cold water by upwelling in the southeast of the Korean Peninsula and the effect of sea breeze in this region are investigated. The coastal upwelling around the southeast coast of the Korea Peninsula is analyzed by using Coastal Oceanographic Data statistical analyses for 5 years were carried out. The period of an cold water event, on the average, was observed southwesterly wind events. The analysis suggests that strong and persistent southwesterly winds in period of an cold water play an important role of bring the moisture to the surface, generating persistent cyclone as jangma. In order to investigate the effect of cold water on sea breeze, we considered two case. First, Exp. 1 is not occurred coastal upwelling on sea breeze. Second, Exp. 2 is occurred cold water on sea breeze. Two experiments were completed separately to the effects of cold water by upwelling. The results show the sea breeze is stronger in Exp. 2, when the cold water occurs, and weaker in Exp. 1, when there is no cold water. In order to verify the effect of the sea breeze on the cold water by upwelling, on the intensification and change of direction of the prevailing wind, the sea breeze effectively intensify cold water condition.

Study on the Cold Mass Occurrence in the Eastern Coast of the Korean Peninsula in Summer (하계 한국동해안 냉수대 발생의 시공간적 분포특성)

  • Suh Young-Sang;Hwang Jae-Dong
    • Journal of Environmental Science International
    • /
    • v.14 no.10
    • /
    • pp.945-953
    • /
    • 2005
  • Daily time series of longshore sea surface temperature (SST) data at 3 stations, sea surface SST data at 58 stations in the eastern coast of the Korean Peninsular from 2001 to 2005 were used in order to study the temporal and spatial variations of the upwelling coastal cold water occurred in summer season. When the cold water occurred, SST has been decreased more than $-5^{\circ}C$ in a day. The cold water occurred frequently in the eastern coastal areas of Korea such as Ulgi, Kampo, Jukbyun. Daily variations of cold water temperature were quantified using remote control buoy system at Kijang in the southeastern coastal water from July to August in 2004. Hourly variations of SST occurred around $\pm3^{\circ}C$ when cold water disappeared at Kijang. There were close relationship between the strength of East Korean Warm Current, North Korean Cold Water and the scale of spatio-temporal cold water variations in summer season.

Spatio-Temporal Variation of Cold Water Masses along the Eastern Coast of Korea in 2013 and 2014

  • Han, In-Seong;Park, Myung-Hee;Min, Seung-Hwan;Kim, Ju-Yeon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.3
    • /
    • pp.286-295
    • /
    • 2016
  • With the results of observations in 2013 and 2014 including ocean buoys, in-situ investigations and wind data, we examined the spatio-temporal variation of cold water masses along the eastern coast of Korea. Usually, a cold water mass first appears along the northern part of the eastern coast from May to July, and then along the southern part of the eastern coast from late June to mid-August. Cold water masses appear 3~5 times a year and remain for 5~20 days in the southwestern part of the East Sea. A distinctive cold water mass appeared usually in mid-July in this area, the surface temperature of which was below $10^{\circ}C$ in some cases. During the appearance of a cold water mass in the southwestern part of the East Sea, the horizontal temperature gradient was large at the surface and a significant low water temperature below $8^{\circ}C$ appeared at the bottom level. This appearance of cold water masses clearly corresponded to southwesterly winds, which generated coastal upwelling.

The Movement of the Cold Water in the Korea Strait

  • Lim, Du Byung
    • 한국해양학회지
    • /
    • v.8 no.1
    • /
    • pp.46-52
    • /
    • 1973
  • From available data, the movement of the cold water in the Korea Strait was investigated. The cold water forms an undercurrent with a speed of 0.10knots near Ulgi in June. Sometimes it reaches a speed of 0.35knots. The cold water forms a sharp wdege in the western channel like a salt wedge in an estuary. The calculated volume transport of the cold water is 17,135 cubic meters per second in June. The external influences are also discussed.

  • PDF

A Study on Cold-water damage on paddy field at the Downstream of the Unmoon Dam (운문댐 하류 논지역에서의 냉수피해 조사연구)

  • Chung, Sang-Ok;Oh, Chang-Jun
    • Current Research on Agriculture and Life Sciences
    • /
    • v.15
    • /
    • pp.39-46
    • /
    • 1997
  • In 1996, a cold-water damage occured in the paddy field at the downstream of the Umoon dam. To study the cause and the preventive measures of the cold-water damage a field study was performed during the growing season of 1997. Field measurements such as water temperatures at reservoir, irrigation canal and in the paddy field were made. As a result, there was no cold-water damage due to the right irrigation water management practice in 1997. The cold-water damage is possible to happen, however, and the preventive measures were provided.

  • PDF