• 제목/요약/키워드: cold plate

검색결과 344건 처리시간 0.026초

다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가 (Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF

용접형 판형 열교환기의 열전달 및 압력강하 특성에 관한 실험적 연구 (Experimental study of Heat Transfer and Pressure Drop Characteristics for the Welded Plate Heat Exchanger)

  • 정종윤;김성수;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.419-424
    • /
    • 2008
  • Heat transfer and pressure drop characteristics of welded plate heat exchanger are studied to apply it for the solution heat exchanger of 210RT absorption system. This study quantifies the effect of mass flow rate and strong solution concentration on the heat transfer coefficient and pressure drop in the plate heat exchanger. The concentration of weak solution is fixed at 55% and the strong solution varies 55%, 57%, and 59% in mass. The results show that the overall heat transfer coefficient and pressure drop increase linearly with increasing Reynolds number. It is also found that the heat transfer coefficient of hot side increases with increasing the concentration of strong solution while the strong solution concentration has no effect on heat transfer coefficient of cold side.

  • PDF

상하 비대칭 롤러를 이용한 이중곡면 성형의 변형특성에 대한 연구 (Deformation Characteristics of Compound Curved Plate Bending by Asymmetric Rollers)

  • 최양렬;신종계
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.38-43
    • /
    • 2002
  • Die-less forming is a cold forming process which is to bend thick flat plates into compound curved plates using two asymmetric rollers. This forming method has several advantages compared with line heating which is widely used to fabricate compound curved pieces in shipyards. The die-less forming, however, has scarcely been studied. Even the deformation mechanism in this forming process has not been understood clearly. So, in this paper, the deformation characteristics of die-less forming is investigated analytically and numerically. for the analytic investigation, slab method based on equilibrium equation is applied. And the mechanism of curvature generation is derived for the asymmetry in roller applied. And three dimensional numerical analyses are performed with realistic modeling of interactions between the rollers and work-piece using finite element program, ABAQUS. It is shown that curvature generation is mainly due to the difference of normal positive strain distribution between the top and bottom surface of the work-piece. And a convex-type curved plate is formed if the center region of the work-piece is rolled with asymmetric rollers of which the lower is larger than the upper in diameter.

판형열교환기 설계프로그램 개발을 위한 응축열전달 및 압력강하 분석 (Analysis on condensation heat transfer and pressure drop to develop design program for plate heat exchangers)

  • 고제현;송영호;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.376-382
    • /
    • 2014
  • 본 연구의 목적은 물에 대한 판형열교환기의 설계프로그램 개발을 위해 응축열전달계수 및 압력강하에 관한 상관식을 확보하는 것이다. 저온측의 단상유동에 관해서는 Ko의 상관식을 사용하였으며 고온측의 응축이 발생하는 이상유동에 대해서는 Annaiev의 상관식과 Lockhart 모델을 적용하여 알고리즘을 제시하였다. 판형열교환기의 운전가능한 범위내에서 상관식의 오차는 상용코드와 비교시 20%이내를 나타냈다.

Establishment of the design stress intensity value for the plate-type fuel assembly using a tensile test

  • Kim, Hyun-Jung;Tahk, Young-Wook;Jun, Hyunwoo;Kong, Eui-Hyun;Oh, Jae-Yong;Yim, Jeong-Sik
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.911-919
    • /
    • 2021
  • In this paper, the design stress intensity values for the plate-type fuel assembly for research reactor are presented. Through a tensile test, the material properties of the cladding (aluminum alloy 6061) and structural material (aluminum alloy 6061-T6), in this case the yield and ultimate tensile strengths, Young's modulus and the elongation, are measured with the temperatures. The empirical equations of the material properties with respect to the temperature are presented. The cladding undergoes several heat treatments and hardening processes during the fabrication process. Cladding strengths are reduced compared to those of the raw material during annealing. Up to a temperature of 150 ℃, the strengths of the cladding do not significantly decrease due to the dislocations generated from the cold work. However, over 150 ℃, the mechanical strengths begin to decrease, mainly due to recrystallization, dislocation recovery and precipitate growth. Taking into account the uncertainty of the 95% probability and 95% confidence level, the design stress intensities of the cladding and structural materials are established. The presented design stress intensity values become the basis of the stress design criteria for a safety analysis of plate-type fuels.

Effect of the suction plate shape on metering performance of a vacuum metering device for garlic seeds

  • Kim, Deok-Keun;Choi, Yeong-Soo;Yang, Seung-Hwan
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.829-844
    • /
    • 2020
  • A vacuum metering device for garlic seeds was developed, and its metering performance was tested according to the design factors. Three design factors were as follows: suction surface diameter (Edge), suction surface curvature (Type), and guide height (Guide). The suction surface curvature represents the distance between the center of the grooved suction plate and the bottom of suction plate. The metering rate and multiple metering rate were analyzed as the metering performance of the developed device with two varieties of garlic seeds: Namhae (warm region-adapted garlic) and Uiseong (cold region-adapted garlic). The best metering performance for the Namhae seeds were found with the following conditions: An Edge, Guide and Type of 40, 4, and 35 mm, respectively. In the case of the Uiseong seeds, the best conditions were as follows: An Edge, Guide and Type of 35, 4, and 30 mm, respectively. The guide height was found to be the most influential design factor on the metering performance of the metering rate and multiple rate for both Namhae seeds and Uiseong seeds. Additionally, the interaction between the area of the suction surface and the curvature of the suction surface had some effects on the multiple rate for the Uiseong seeds. It was concluded that the guide height should be 4 mm or higher so that more than 90% of the metering rate could be achieved for the tested garlic seeds with the developed metering device.

냉가스 추진장치를 이용한 마이크로 노즐의 성능평가 (Performance Evaluation of Micro-nozzle Using Cold Gas Propulsion System)

  • 정성철;김연호;오화영;명노신;허환일
    • 한국추진공학회지
    • /
    • 제11권6호
    • /
    • pp.42-49
    • /
    • 2007
  • 본 연구에서는 마이크로 추진장치의 개발을 위한 기초연구로 마이크로 노즐의 유동 특성을 분석하였다. 냉가스 추진원리를 이용하였으며, 추진 장치의 노즐 목 직경이 1.0, 0.5, 0.25 mm 인 마이크로 노즐을 방전가공을 이용하여 제작하였다. 판스프링과 스트레인 게이지를 이용한 추력측정장치를 이용하여 추력을 측정하였으며, 대기압 환경과 진공환경에서 마이크로 노즐의 유동특성을 분석하였다. 추진제는 아르곤과 질소를 사용하였으며, 실험 결과를 CFD 결과와 비교하였다. 연구 결과 노즐의 소형화로 인해 점성과 배압에 의한 유동손실이 발생함을 확인할 수 있었다.

Fitness is Recovered with the Decline of Dimethachlon Resistance in Laboratory-induced Mutants of Sclerotinia sclerotiorum after Long-term Cold Storage

  • Li, Jin-Li;Wu, Feng-Ci;Zhu, Fu-Xing
    • The Plant Pathology Journal
    • /
    • 제31권3호
    • /
    • pp.305-309
    • /
    • 2015
  • After four years of cold storage, dimethachlon resistance of two laboratory-induced resistant Sclerotinia sclerotiorum isolates SCG7 and LA50 declined by 99.5% and 98.9%, respectively, and cross resistance to iprodione and procymidone also declined dramatically. Along with the decline of fungicide resistance, osmotic sensitivity to sodium chloride and glucose decreased tremendously; mycelial growth rate, sclerotia number and weight per potato dextrose agar (PDA) plate increased on average by 118.6%, 85. 5% and 64.5%, respectively; and virulence to detached leaves of oilseed rape increased by 72.7% on average. Significant negative correlations were detected between dimethachlon resistance levels and mycelial growth rate on PDA (r = -0.980, P = 0.021), and between resistance levels and lesion diameters on detached leaves of oilseed rape plants (r = -0.997, P = 0.002). These results have profound implications for assessing the potential risk for resistance development to dicarboximide fungicides in S. sclerotiorum.

상온 능동형 자기 재생 냉동기의 개발 (Development of the active magnetic regenerative refrigerator for room temperature application)

  • 박인명;김영권;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

Protocol for testing of cold-formed steel wall in regions of low-moderate seismicity

  • Shahi, Rojit;Lam, Nelson;Gad, Emad;Wilson, John
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.629-647
    • /
    • 2013
  • Loading protocols have been developed for quasi-static cyclic testing of structures and components. However, it is uncertain if protocols developed for conditions of intense ground shaking in regions of high seismicity would also be applicable to regions of low-moderate seismicity that are remote from the tectonic plate boundaries. This study presents a methodology for developing a quasi-static cyclic displacement loading protocol for experimental bracing evaluation of cold-formed steel stud shear walls. Simulations presented in the paper were based on conditions of moderate ground shaking (in Australia). The methodologies presented are generic in nature and can be applied to other regions of similar seismicity conditions (which include many parts of China, Korea, India and Malaysia). Numerous response time histories including both linear and nonlinear analyses have been generated for selected earthquake scenarios and site classes. Rain-flow cycle counting method has been used for determining the number of cycles at various ranges of normalized displacement amplitude. It is found that the number of displacement cycles of the loading protocol increases with increasing intensity of ground shaking (associated with a longer return period).