• 제목/요약/키워드: cold air sink

검색결과 25건 처리시간 0.026초

열전소자를 이용한 배수형 전자제습기 개발 (Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element)

  • 강덕홍;김성완;김기홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF

Temporal Variation of Air Temperature in Ice-Valley at Milyang in Association with Ice Formation

  • Lee, Soon-Hwan;Hwang, Soo-Jin
    • 한국지구과학회지
    • /
    • 제28권5호
    • /
    • pp.598-602
    • /
    • 2007
  • A long-term in situ observation was carried out in the Ice-valley at Milyang in order to explain the factors and processes associated with the summertime ice formation. The variation of temperature inside Ice-valley in relation with ice formation in summer time was found to depend on precipitation rate in spring and cold air sinking in autumn and winter. The rate of temperature rising tends to correspond to sensible heat release depending on the precipitation amount at the freezing location. The reason of the cold air accumulation in a talus in the Ice-valley is the cold air sinking over the surface of talus due to the occurrence of outside clod air mass and the accumulated cold air from autumn to spring flow outside at the bottom of talus. The out-flowing cold air can result in the ice formation in the hot summer.

충돌 공기제트에서 국한 유로 내 발포 알루미늄 방열기의 열전달 수치해석 (A Numerical Study on Beat Transfer from an Aluminum Foam Heat Sink by Impinging Air Jet in a Confined Channel)

  • 이상태;김서영;이관수
    • 대한기계학회논문집B
    • /
    • 제26권6호
    • /
    • pp.883-892
    • /
    • 2002
  • A numerical study has been carried out to investigate the flow and heat transfer from an aluminum foam heat sink in a confined channel. A uniform heat flux is given at the bottom of the aluminum foam heat sink, which is horizontally placed on the heated surface. The channel walls are assumed to be adiabatic. Cold air is supplied from the top opening of the channel and exhausted to the channel outlet. Comprehensive numerical solutions are acquired to the governing Wavier-Stokes and energy equations, using the Brinkman-Forchheimer extended Darcy model and the local thermal non-equilibrium model f3r the region of porous media. Details of flow and thermal fields are examined over wide ranges of the principal parameters; i.e., the Reynolds number Re, the height of heat sink h/H, porosity $\varepsilon$and pore diameter ratio $R_{H}$.

유한요소법과 최적설계기법을 활용한 히트싱크 콜드 플레이트 최적 설계 (Optimized Design of a Cold Plate Heat Sink using FEM and Optimization)

  • 홍석무;서형준;김종문;심재원;황지훈
    • 소성∙가공
    • /
    • 제23권7호
    • /
    • pp.419-424
    • /
    • 2014
  • In order to improve efficiency, an outdoor unit using a refrigerant cooling method is designed into many air conditioner systems. The heat exchanger is composed of a Cu tube and an plate. The optimal design for the cold plate is very important because the efficiency of the heat transfer depends on the contact area between the Cu tube and the cold plate. The current study focused on the design of the cold plate to obtain a uniform contact between the Cu tube and the cold plate. Both FE(finite element) analysis and optimization were used in the design. The contact area between the tube and plate was predicted and improved by 16% through the press forming simulations. The springback after press forming was also reduced when the optimized design parameters were used. To verify the validity of the optimal cold plate design, a verification test was conducted. As a result, the performance of the heat exchanger improved by 34% when compared to benchmarked products.

열전모듈을 이용한 에어컨의 방열부 냉각특성에 대한 연구 (Cooling Characteristics at Hot Side of the Thermoelectric Module for an Air Conditioner)

  • 김서영;강병하;장혁재;김석현
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.214-220
    • /
    • 2002
  • A small air conditioner using thermoelectric module has been designed and built. Three types of cooling methods, such as air cooling, closed-loop water cooling, and evaporative cooling, for hot side of thermoelectric module have been investigated. Among three types of cooling method, the evaporative cooling method is seen to be the most effective to achieve the steady state operation of a thermoelectric air conditioner The system performance with evaporative cooling method are also studied in detail for several oprating parameters, such as input power to the thermoelectric module, water or air flow rate at the hot side, and air flow rate at the cold side. The results obtained indicate that the cooling capacity of a system is increased with an increase in the input power to the thermoelectric module while the system COP is decreased. It is also found that the optimal air flow rate as well as water flow rate at the hot side is needed for the best system performance at a liven operating condition. Both the system COP and cooling capacity are increased as the air flow rate at cold side is increased.

열전소자를 이용한 싱글 및 캐스케이드 냉동시스템의 냉각 성능에 관한 연구 (Study on the Cooling Performance of Single and Cascade Refrigeration Systems Using Thermoelectric Modules)

  • 임창학;김동우;김용찬;서국정
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.641-646
    • /
    • 2013
  • The purpose of this study is to improve the cooling performance of single and cascade refrigeration systems using thermoelectric modules. The system consists of a heat sink, fan, and thermoelectric module. The operating parameters considered in this study include power distribution between the first- and second-stage thermoelectric modules, air flow, and variable condensing unit. The cooling capacity increased with decreases in the temperature difference between hot and cold surfaces, but decreased with increases in the condensing temperature. The COP decreased with increasing electric power of the thermoelectric module because of the increased Joule heat. The cooling performance improvement using the thermoelectric module is represented by the freezer temperature.

LNG 냉열 에너지의 지역 냉방 시스템에 관한 기반 연구 (A Basic Study on the District Cooling System of LNG Cold Thermal Energy)

  • 김청균
    • 한국가스학회지
    • /
    • 제7권4호
    • /
    • pp.36-43
    • /
    • 2003
  • 본 논문에서는 LNG 냉열 에너지를 활용한 지역 냉방 시스템 가능성에 대해 고찰하고자 한다. 액상의 LNG는 기상의 가스로 변환하는 과정에서 많은 냉열 에너지를 발생한다. 최근에 빙축열을 이용한 건물의 냉방 시스템 구축과 심층수를 이용한 지역 냉방 시스템이 도심지의 기존 사무실 건물이나 대규모 건물의 냉방장치로 도입되고 있는 상황이다. LNG의 냉열 에너지는 기존의 냉매에 의존한 개별 냉방 시스템을 대체하는 새로운 냉열 에너지 공정으로 쾌적한 공간을 제공하는 천연의 대규모 냉각매체로 재사용될 수 있다. 버려지는 냉열 에너지는 낮은 코스트로 운영될 수 있는 중요한 청정 에너지원이기 때문에 냉방 시스템으로 개발되면, 기존의 에어콘 시스템에 견주어 볼 때 공기중에 유해한 오염원의 발생과 환경적으로 유해한 냉매 방출을 대폭적으로 줄일 수 있는 우수한 냉방 시스템이 될 것이다. 따라서, 본 연구에서는 냉열 에너지를 활용한 지역 냉방 시스템에 대한 환경 친화적 기본적 설계 개념, 여러 가지 냉방 시스템 성능에 대한 유익한 기반적 정보를 제공하고자 한다.

  • PDF

LNG 냉열을 이용하는 동력사이클 열역학 해석 (Thermodynamic Analysis of Power Generation Cycle Utilizing LNG Cold Energy)

  • 최권일;장홍일
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권1호
    • /
    • pp.48-55
    • /
    • 1999
  • thermodynamic cycle analysis has been performed for the power generation systems to utilize the cold energy of liquefied natural gas (LNG). The power cycle used the air or water at room temperature as a heat source and the LNG at cryogenic temperature as a heat sink. Among manypossible configurations of the cycle. the open Rankine cycle. and the closed Brayton cycle, and the closed Rankine cycle are selected for the basic analysis because of their practical importance. The power output per unit mass of LNG has been analytically calculated for various design parameters such as the pressure ratio. the mass flow rate. the adiabatic efficiency. the heat exchanger effectiveness. or the working fluid. The optimal conditions for the parameters are presented to maximize the power output and the design considerations are discussed. It is concluded that the open Rankine cycle is the most recormmendable both in thermodynamic efficency and in practice.

  • PDF

남극 세종 기지 주변의 복사, 기온 및 풍향의 특징 (The Characteristics of Radiation, Temperature and Wind Direction around King Sejong Station, Antarctica)

  • 최태진;이방용;김성중;박유민;윤영준
    • 지구물리
    • /
    • 제9권4호
    • /
    • pp.397-408
    • /
    • 2006
  • 남극 반도와 그 주변에서의 온난화는 시간적, 공간적 변동이 크기 때문에 이 지역에서의 국지 기후를 이해하는 것이 필요하다. 이 연구의 목적은 남극 세종 기지 주변에서의 지표 복사, 기온 그리고 풍향의 특징을 밝혀내고, 그 변수들간의 상관 관계를 조사하는 것이다. 연구지는 연간 15-20 Wm-2의 복사 에너지를 흡수하지만, 여름 (12월-1월)에는 평균적으로 85 Wm-2의 복사 에너지를 흡수하였다. 이 흡수량은 남극의 다른 지역에 비해 상당히 큰 값이다. 월 평균 기온은 -7.7-2.8oC 이었으며, 매년 다른 변동을 보였다. 북서, 서 및 동풍이 주풍이었으며, 풍향의 변동이 기온 변동을 설명할 수 있었다. 찬 동풍과 따뜻한 북서 및 북풍 빈도의 변동이 특히 여름철 지표 복사 수지에도 크게 영향을 주었으며, 이 시기의 대기와 지면 간의 에너지 교환에 풍향이 중요한 역할을 하는 것으로 보인다.

  • PDF