• Title/Summary/Keyword: coil embolization

Search Result 165, Processing Time 0.027 seconds

Simple Coiling versus Stent-Assisted Coiling of Paraclinoid Aneurysms : Radiological Outcome in a Single Center Study

  • Kim, Soo Yeon;Park, Dong Sun;Park, Hye Yin;Chun, Young Il;Moon, Chang Taek;Roh, Hong Gee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.644-653
    • /
    • 2017
  • Objective : Paraclinoid aneurysms are a group of aneurysms arising at the distal internal carotid artery. Due to a high incidence of small, wide-necked aneurysms in this zone, it is often challenging to achieve complete occlusion when solely using detachable coils, thus stent placement is often required. In the present study, we aimed to investigate the effect of stent placement in endovascular treatment of paraclinoid aneurysms. Methods : Data of 98 paraclinoid aneurysms treated by endovascular approach in our center from August 2005 to June 2016 were retrospectively reviewed. They were divided into two groups : simple coiling and stent-assisted coiling. Differences in the recurrence and progressive occlusion between the two groups were mainly analyzed. The recurrence was defined as more than one grade worsening according to Raymond-Roy Classification or major recanalization that is large enough to permit retreatment in the follow-up study compared to the immediate post-operative results. Results : Complete occlusion was achieved immediately after endovascular treatment in eight out of 37 patients (21.6%) in the stent-assisted group and 18 out of 61 (29.5%) in the simple coiling group. In the follow-up imaging studies, the recurrence rate was lower in the stent-assisted group (one out of 37, 2.7%) compared to the simple coiling group (13 out of 61, 21.3%) (p=0.011). Multivariate logistic regression model showed lower recurrence rate in the stent-assisted group than the simple coiling group (odds ratio [OR] 0.051, 95% confidence interval [CI] 0.005-0.527). Furthermore there was also a significant difference in the rate of progressive occlusion between the stent-assisted group (16 out of 29 patients, 55.2%) and the simple coiling group (10 out of 43 patients, 23.3%) (p=0.006). The stent-assisted group also exhibited a higher rate of progressive occlusion than the simple coiling group in the multivariate logistic regression model (OR 3.208, 95% CI 1.106-9.302). Conclusion : Use of stents results in good prognosis not only by reducing the recurrence rate but also by increasing the rate of progressive occlusion in wide-necked paraclinoid aneurysms. Stent-assisted coil embolization can be an important treatment strategy for paraclinoid aneurysms when considering the superiority of long term outcome.

Long Term Outcome of In-Stent Stenosis after Stent Assisted Coil Embolization for Cerebral Aneurysm

  • Kim, Sung Jin;Kim, Young-Joon;Ko, Jung Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.536-544
    • /
    • 2019
  • Objective : The objective of this study was to evaluatelong-term radiologic prognosis and characteristics of in-stent stenosis (ISS) after stent assisted coiling (SAC) for cerebral aneurysm and analyze its risk factors. Methods : Radiological records of 362 cases of SAC during 10 years were retrospectively reviewed. Patients were included in this study if they had follow-up angiogram using catheter selected angiography at least twice. All subjected were followed up from 12 months to over 30 months. Of 120 patients, 123 aneurysms were enrolled. Patient data including age, sex, aneurysm size, neck size, procedural complication, kinds of stent, ISS associated symptom, ruptured state, location of ISS, degree of ISS, radiologic prognosis of ISS, follow-up period of time, and medical comorbidities such as hypertension, diabetes mellitus (DM), dyslipidemia, and smoking were collected.Statistical comparisons of group clinical characteristics were conducted for the total population. Results : Among 123 casesof aneurysm, 22 cases (17.9%) of ISS were revealed on follow-up angiography. Multiple stenting was performed in three cases and intra-procedural rupture occurred in two cases. Most cases were asymptomatic and symptomatic stenosis was identified in only one case. Sixteen cases were ruptured aneurysm. Mild stenosis was observed in 11 cases. Moderate stenosis was found in eight cases and severe stenosis was identified in three cases. Mean timing of identification of ISS was 8.90 months. The most common type was proximal type. Most cases were improved or not changed on follow-up angiography. Only one case was aggravated from mild stenosis to occlusion of parent artery. Mean follow-up period was 44.3 months. We compared risk factors and characteristic between ISS group and non-ISS group using univariate analysis. Multiple stenting was performed for three cases (13.6%) of the ISS group and four cases (4.0%) of the non-ISS group, showing no statistical difference between the two groups (p=0.108). Additionally, the proportion of patients who had more than two risk factors among four medical risk factors (hypertension, DM, dyslipidemia, and smoking) was higher in the ISS group than that in the non-ISS group, the difference between the two was not statistically significant either (31.8% vs. 12.9%, p=0.05). Conclusion : Clinical course and long-term prognosis of ISS might be benign. Most cases of ISS could be improved or not aggravated. Control of medical co-morbidity might be important. To the best of our knowledge, our study had more cases with longer follow-up period of time than other reports.

A new strategy for transcatheter closure of patent ductus arteriosus with recent-generation devices (경피적 동맥관 폐쇄술에서 최근의 기구들의 전략적 이용과 결과)

  • Kim, Sang Yee;Lee, Soo Hyun;Kim, Nam Kyun;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.4
    • /
    • pp.488-493
    • /
    • 2009
  • Purpose : The aim of this study was to assess the efficacy and safety of recent-generation patent ductus arteriosus (PDA) closure devices applied by a new selection strategy according to the characteristics of each PDA. Methods : From February 2003 to January 2006, 138 patients underwent transcatheter closure of PDA (study group). According to the size and morphology of each ductus, a COOK Detachable Coil or 'flex' PFM Nit-Occlud was used for a small ductus (group 1, n=43); 'medium' PFM Nit-Occlud (group 2, n=49) for a moderate ductus; and an Amplatzer Duct Occluder (group 3, n=46) for a large ductus. The 83 patients who underwent transcatheter closure of PDA from February 2000 to January 2003 were defined as the comparison group. The Qp/Qs ratio, pulmonary/aorta pressure ratio, and MD of the ductus were compared. Immediate and follow-up results including residual shunts and complications were also evaluated and compared among groups. Results : In all 138 patients, complete occlusions were confirmed without major complications, while procedure failure (n=2, 2.2%), device embolization (n=1, 1.1%), and persistent residual shunt (n=4, 4.5%) were documented in the comparison group. Total complication rates were lower in the study group than in the comparison group (study group, 1.4%; comparison group, 9.0%; P<0.05). Conclusion : A novel strategy adopting the merits of various recent-generation devices for transcatheter closure of PDA provides excellent clinical results with minimal risk.

Medico-Surgical Cooperative Treatment of Pulmonary Atresia with Intact Ventricular Septum (심실중격 결손이 없는 폐동맥 폐쇄의 내과-외과적 협동치료)

  • Kim, Kyeong Sik;Kweon, Byeong Chul;Lee, Jong Kyun;Choi, Jae Young;Sul, Jun Hee;Lee, Sung Kyu;Park, Young Whan;Cho, Bum Koo
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.250-258
    • /
    • 2003
  • Purpose : The actual clinical examples of co-appliance of catheter intervention with surgical procedures in the treatment of pulmonary atresia with an intact ventricular septum(PA/IVS) which we have experienced in our institution are here shown, and the anatomical and hemodynamical profiles between each method is compared. Methods : Medical records of 33 patients with PA/IVS who underwent various treatment from January, 1995 to December, 2000 were reviewed for a retrograde study. Results : In three out of 10 patients who underwent percutaneous balloon pulmonary valvotomy (PPV), residual pulmonary stenosis were observed in their out patient department(OPD) follow-ups, eventually necessitatig balloon pulmonary valvuloplasty(BPV). One out of three patients exhibited deterioration of tricuspid regurgitation after BPV, requiring surgical tricuspid annuloplasty(TAP). Two out of the seven patients who received primarily surgical right ventricle outlet tract(RVOT) repair without any systemic-pulmonary shunt or intervention needed additional intervention employing cardiac catheterization after operation. Two patients received interventional catheterization before surgical RVOT repair. In five out of 11 cases of Fontan type operation, coil embolization of collateral circulation was done before total cavo-pulmonary connection(TCPC), and in three cases, interventional catheterization was needed after TCPC. Conclusion : Both medical and surgical treatment modalities are widely used in management of PA/IVS patients, and recent results prove that medico-surgical cooperative treatment is essential.

A Clinical Study of Congenital Intrahepatic Portosystemic Shunt Diagnosed in Neonatal Period (신생아기에 진단된 선천성 간내 문맥 전신성 단락의 임상적 고찰과 치료)

  • Kim, Ji-Young;Kim, Kyung-A;Lee, Yeon-Kyung;Ko, Sun-Young;Shin, Son-Moon;Han, Byung-Hee
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.117-123
    • /
    • 2011
  • Purpose: Congenital intrahepatic portosystemic shunts are rare disease and clinically asymptomatic shunts may be detected by chance on ultrasonogram before and after birth. We studied clinical course, treatment and prognosis of congenital intrahepatic portosystemic shunt at prenatal or neonatal period. Methods: Medical records of 8 patients which were diagnosed in intrahepatic portosystemic shunt in Cheil General Hospital from 2006 through 2010 were reviewed retrospectively. Results: Eight patients with congenital intrahepatic portosystemic shunts were identified. Six patients were diagnosed at prenatal radiological screening, including three cases of intrauterine growth restriction and two cases of preterm baby. One case with increased serum ammonia underwent coil embolization. In four cases including one case that presented elevated direct bilirubin, shunts were closed spontaneously within 11th month after birth. Two patients were diagnosed on abdominal sonogram after birth because of elevated direct hyperbilirubinemia, all of whom presented intrauterine growth restriction. Closure of shunts was confirmed during 4th month to 6th month. Conclusion: Congenital intrahepatic portosystemic shunts are clinically asymptomatic mostly and spontaneous closure is expected within 2 years age. But occasionally they have severe complication, so clinical and radiological observation is needed. Specially in cases of intrauterine growth retardation without evident cause, the possible diagnosis of congenital intrahepatic portosystemic shunts should be considered and prenatal and postnatal examination should be performed. When prenatal diagnosis is made, fetal wellbeing should be monitored periodically until spontaneous closure of shunts.