• Title/Summary/Keyword: coil array

Search Result 94, Processing Time 0.024 seconds

Preliminary Study on the MR Temperature Mapping using Center Array-Sequencing Phase Unwrapping Algorithm (Center Array-Sequencing 위상펼침 기법의 MR 온도영상 적용에 관한 기초연구)

  • Tan, Kee Chin;Kim, Tae-Hyung;Chun, Song-I;Han, Yong-Hee;Choi, Ki-Seung;Lee, Kwang-Sig;Jun, Jae-Ryang;Eun, Choong-Ki;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.131-141
    • /
    • 2008
  • Purpose : To investigate the feasibility and accuracy of Proton Resonance Frequency (PRF) shift based magnetic resonance (MR) temperature mapping utilizing the self-developed center array-sequencing phase unwrapping (PU) method for non-invasive temperature monitoring. Materials and Methods : The computer simulation was done on the PU algorithm for performance evaluation before further application to MR thermometry. The MR experiments were conducted in two approaches namely PU experiment, and temperature mapping experiment based on the PU technique with all the image postprocessing implemented in MATLAB. A 1.5T MR scanner employing a knee coil with $T2^*$ GRE (Gradient Recalled Echo) pulse sequence were used throughout the experiments. Various subjects such as water phantom, orange, and agarose gel phantom were used for the assessment of the self-developed PU algorithm. The MR temperature mapping experiment was initially attempted on the agarose gel phantom only with the application of a custom-made thermoregulating water pump as the heating source. Heat was generated to the phantom via hot water circulation whilst temperature variation was observed with T-type thermocouple. The PU program was implemented on the reconstructed wrapped phase images prior to map the temperature distribution of subjects. As the temperature change is directly proportional to the phase difference map, the absolute temperature could be estimated from the summation of the computed temperature difference with the measured ambient temperature of subjects. Results : The PU technique successfully recovered and removed the phase wrapping artifacts on MR phase images with various subjects by producing a smooth and continuous phase map thus producing a more reliable temperature map. Conclusion : This work presented a rapid, and robust self-developed center array-sequencing PU algorithm feasible for the application of MR temperature mapping according to the PRF phase shift property.

  • PDF

Experiments of a Novel Magnetic Levitation Stage for Wide Area Movements

  • Jeon, Jeong-Woo;Caraiani, Mitica;Oh, Hyeon-Seok;Kim, Sung-Shin
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.558-563
    • /
    • 2012
  • In this paper, a novel planar type magnetic levitation system without other assistant devices is proposed and it can move with 6 degree of freedom (X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$) in wafer size as well as in nano scale positioning.The mover is composed with 2-D Halbach permanent magnet array and the stator is composed with $10{\times}10$ coil arrays.It was composed in laboratory and tested with short stroke (4 [mm]) and long stroke (160 [mm])movements. The errors of short movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}3urad$, ${\pm}2urad$, ${\pm}1urad$]The errors of long stroke movement test is [X, Y, Z, ${\theta}_X$, ${\theta}_Y$, ${\theta}_Z$]${\leq}$ [${\pm}200nm$, ${\pm}200nm$, ${\pm}250nm$, ${\pm}1.5urad$, ${\pm}2urad$, ${\pm}0.5urad$].

Development of Hazardous Objects Detection Technology based on Metal/Non-Metal Detector (금속/비금속 복합센서기반 위험물 탐지기술 개발)

  • Yoo, Dong-Su;Kim, Seok-Hwan;Lee, Jeong-Yeob;Lee, Seok-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.120-125
    • /
    • 2014
  • Conventional handheld metal detectors use a single induction coil to detect the metallic parts of explosive objects, and the detector generates an acoustic signal from its magnetic response to a metallic object so that an operator can confirm the existence of mines. Though metal detectors have very useful detection mechanisms to find mines, it is easy to cause a high false alarm ratio due to the detection of non-explosive metallic items such as cans, nails and other pieces of metal, etc. Also, because of the physical characteristic of a metal detector it is hard to detect non-metallic objects such as mines made of wood or plastic. Furthermore, the operator must move it to the left and right slowly and repeatedly to attain enough sensor signals to confirm the existence of mines using only a monotonous acoustic signal. To resolve the disadvantages of handheld detectors, many new approaches have been attempted, such as an arrayed detector and a visualization algorithm based on metal/non-metal sensor. In this paper, we introduce a visualization algorithm with a metal/non-metal complex sensor, an arrayed metal/non-metal sensor and the their testing and evaluation.

The Performance Analysis of the Fin-Tube Heat Exchanger Using CFC Alternative Refrigerant (CFC 대체냉매를 사용한 핀-관 열교환기의 성능해석)

  • 박희용;박경우;차재병
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2358-2372
    • /
    • 1993
  • In this study, the computer modeling for prediction of the performance of fin-tube heat exchanger using alternative refrigerant, HFC-134a was developed and the computer program for calculating the various properties of HFC-134a and the existing refrigerant CFC-12 and HCFC-22 was made. The heat exchanger modeling is based on a tube-by-tube approach, which is capable of analysis for the complex coil array. Performance of each tube is analyzed separately by considering the cross-flow heat transfer with external airstream and the appropriate heat and mass transfer relationships. A performance comparison according to the different refrigerants is provided using this developed model. As the result of this study, total heat transfer rate of evaporator and condenser using HFC-134a were found higher than that of using CFC-12 for the same operating conditions. When the mass flow rate of HFC-134a was less than CFC-12 about 18. 16%, the cooling capacities of evaporator were found to be the same.

Design, Implementation and Testing of HF transformers for Satellite EPS Applications

  • Zahran, Mohamed
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.217-227
    • /
    • 2008
  • The electric power subsystems (EPS) of most remote sensing satellites consist of a solar array as a source of energy, a storage battery, a power management and control (PMC) unit and a charge equalization unit (CEU) for the storage battery. The PMC and CEU use high frequency transformers in their power modules. This paper presents a design, implementation and testing results of a high frequency transformer for the EPS of satellite applications. Two approaches are used in the design process of the transformer based on the pre-determined transformer specifications. The transformer is designed based on an ETD 29 ferrite core. The implemented transformer consists of one center-tapped primary coil with eleven center-tapped secondary coils. The offline calculation results and measured values of R, L for transformer coils are convergence. A test circuit for measuring the transformer parameters like voltage, current and B-H hysteresis was implemented and applied. The test results confirm that the voltage waveforms of both primary and secondary coils were as desired. No overlapping occurred between the control signal and the transformer, which was not saturated during testing even during a short circuit test of the secondary channels. The dynamic B-H loop characteristics of the used transformer cores were measured. The sample test results are given in this paper.

Evaluation of the Integrity of TIG Welding Using Non-Contact SH-EMAT (비접촉 SH-EMAT을 이용한 TIG용접부 건전성 평가)

  • Park, Tae Sung;Park, Yeong Hwan;Park, Ik Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.48-53
    • /
    • 2016
  • An EMAT can be used to reliably detect defects as it serves as a non-contact transducer with the ability to transmit ultrasonic waves into specimens without couplant. Moreover, an EMAT can easily generate desired waves by altering the design of the coil and magnet. This study proposes an SH-EMAT to evaluate the integrity of the TIG welding part. A stainless steel was welded using the TIG welding method. The welding current was varied to create artificial defects. Both the PA-UT and the RT were applied to verify the defect size. The experimental results generated by using the EMAT were compared with those methods. The amplitude was observed to decrease with an increase in the defect size. These results confirmed that the presence of defects can be reliably detected by attenuation of signal amplitude. The results demonstrated that the proposed method is suitable for evaluating the integrity of TIG welding.

Precision Stage Using A Novel Contact-Free Planar Actuator Based on Combination of Electromagnetic forces (전자기력 조합에 기초한 평면 구동기를 이용한 자기 부상 방식 초정밀 스테이지)

  • Jeong, Gwang-Seok;Baek, Yun-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1863-1872
    • /
    • 2001
  • In this Paper, we suggest the precision stage using a novel non-contact planar actuator that utilizes an interaction between an array type of air-core solenoids and permanent magnets. The former with axes arranged in the mutually orthogonal direction is fixed on the stator and the latter with the same polar direction is attached below the stage. The promising magnetic structure has little uncertainty such as hysteresis loss caused by ferromagnetic material, then it is simple to quantify the magnetic phenomenon. And all the magnetic forces are transmitted through narrow air-gap between the coil and the permanent magnet, therefore the structure can be highly compacted. Furthermore, the stage or plate can be perfectly isolated from the stator without any wire connection, leading to diminish the generating possibility of wear particles due to mechanical contact. Then. it is estimated that the proposed operating principle is very suitable for work requiring high accuracy and cleanness. or general-purpose nano stage. The main issues rebated to the plate driving are discussed here.

Present Condition and View of Eddy Current Testing Probe for Nuclear Power Plant Steam Generator Tube Examination (원전 증기발생기 세관 검사를 위한 와전류 탐상 프로브의 현황 및 전망)

  • Kim Ji-Ho;Lee Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-245
    • /
    • 2006
  • In the examination of Steam Generator (SG) tube in Nuclear Power Plant (NPP) Eddy Current Testing (ECT) probes play an Important role in detecting the defects. Bobbin probe and Rotating Pancake Coil (RPC) probe is usually used for the inspection of SG tube. Bobbin probe is good at high speed inspection, but ability of detection of circumferential defect is very weak. On the contrary RPC probe, which moves for inspection in the direction of axial and circumferential simultaneously, has very slow inspection speed, but it was excellent detection capability fur small cracks, which is hardly detected by bobbin probe. Many examinations of SG tube examination of NPP are achieved during short period. Therefore, solution about this must develop probe of new form for examination performance and examination time shortening of other probe. In this paper, analyzed technological present condition of Bob-bin probe and RPC probe been using in Nondestructive Testing (NDT) for SG tube defect detection and Appeared about background theory and view of developed probe newly.

  • PDF

Equivalency Assessment for an Eddy Current System Used for Steam Generator Tubing Inspection

  • Cho, Chan-Hee;Lee, Tae-Hun;Yoo, Hyun-Ju;Moon, Gyoon-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.4
    • /
    • pp.258-267
    • /
    • 2015
  • Eddy current testing is widely used for inspecting steam generator tubing in nuclear power plants (NPPs). The inspection technique for steam generator tubing in NPPs should be qualified in accordance with examination guidelines. When the components of a qualified system such as eddy current tester, probe, and data analysis program, are changed, the equivalency of the modified system to the originally qualified system must be verified. The eddy current tester is the most important part of an eddy current testing system because it excites and transmits alternating currents to the probe, receives coil impedance of the probe and generates signals for anomalies. The Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed an eddy current testing system with an eddy current tester and data acquisition-analysis program for inspecting the steam generator tubing in NPPs; this system can be used for an array probe and as a bobbin and rotating probes. The equivalency assessment for the currently developed system was carried out, and we describe the results in this paper.

Structural Optimization for Nonlinear Dynamic Response of Solenoid Actuator (솔레노이드 액추에이터의 비선형 동적응답에 대한 구조최적설계)

  • Baek, Seokheum;Kim, Hyunsu;Jang, Deukyul;Lee, Seungbeom;Kwon, Youngseok;Ro, Euidong;Lee, Changhoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.113-120
    • /
    • 2013
  • This paper proposes a design optimization approach for core of solenoid actuators by combining optimization techniques with the finite element method (FEM). A solenoid is an important element part which hydraulically controls a transmission system, etc. The demanded feature of the solenoid is that it performs an electromagnetic force output being constant regardless of the stroke and being proportional to coil current. The plunger compresses a spring with a minimum force of 12 N over an 1.7 mm travel. The orthogonal array, analysis of variance (ANOVA) techniques and response surface optimization, are employed to determine the main effects and their optimal design variables. The methodology is demonstrated as a optimization tool for the core design of a solenoid actuator.