• Title/Summary/Keyword: coefficient-based method

Search Result 2,699, Processing Time 0.03 seconds

Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5 (PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구)

  • Lee, Yong Hwan;Park, Jin Su;Oh, Jun;Choi, Jin Soo;Kim, Hyun Jae;Ahn, Joon Young;Hong, You Deog;Hong, Ji Hyung;Han, Jin Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.

Thickness Dependence of Orientation, Longitudinal Piezoelectric and Electrical Properties of PZT Films Deposited by Using Sol-gel Method (솔젤법에 의해 제조한 PZT(52/48) 막의 두께에 따른 우선배향성의 변화 및 이에 따른 압전 및 전기적 물성의 변화 평가)

  • Lee, Jeong-Hoon;Kim, Tae-Song;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.10
    • /
    • pp.942-947
    • /
    • 2001
  • Thickness dependence of orientation on piezoelectric and electrical properties was investigated by PZT (52/48) films by diol based sol-gel method. The thickness of each layer by spinning at one time was $0.2{\mu}m$ and crack-free films could be successfully deposited on 4 inches Pt/Ti/$SiO_2$/Si substrates by 0.5 mol solutions in the range from $0.2{\mu}m$ to $3.8{\mu}m$. Excellent P-E hysteresis curves were achieved, which were attributed to the well-densified PZT films and columnar grain without pores or any defects between interlayers. The (111) preferred orientation of films were shown in the range of thickness below $1{\mu}m$. As the thickness increased, the (111) preferred orientation disappeared from $1{\mu}m$ to $3{\mu}m$ region, and the orientation of films became random above $3{\mu}m$. Dielectric constants and longitudinal piezoelectric coefficient, $d_{33}$, measured by pneumatic method were saturated around the value of about 1400 and 300 pC/N respectively above the thickness of $1{\mu}m$.

  • PDF

Characterization of crystal phase evolution in cordierite honeycomb for diesel particulate filter by using rietveld refinement and SEM-EDS methods (Rietveld 정밀화법과 SEM-EDS 분석에 의한 DPF용 코디어라이트 하니컴 세라믹스의 결정성장 과정 분석)

  • Chae, Ki-Woong;Kim, Kang San;Kim, Jeong Seog;Kim, Shin-Han
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.3
    • /
    • pp.116-126
    • /
    • 2021
  • Diesel particulate filter (DPF) is a typical application field of cordierite (Mg2Al4Si5O18) honeycomb. Green body for DPF honeycomb was extruded using slurry paste and sintered at the temperature range of 980~1450℃. Quantitative crystal phase analysis was carried out by using Rietveld refinement method for powder XRD data. In conjunction with the quantitative Rietveld analysis, SEM-EDS analysis was carried for the crystal phases (indialite, cordierite, cristobalite, alumina, spinel, mullite, pro-enstatite). After removing amorphous phase on the sintered surfaces by chemical etching method, the shape and composition of the crystal phases can be clearly identified by SEM-EDS method. By combining the Rietveld refinement method and SEM-EDS analysis, crystal phase evolution process in DPF cordierite ceramics could be clarified. In addition, the coefficient of thermal expansion (CTE) of the DPF honeycombs were measured and compared with the calculated CTEs based on the quantitative crystal phase analysis results.

Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System (케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.467-475
    • /
    • 2009
  • Existing studies have suggested Universal Curve only for supplemental damping by damper. Therefore net damping has been determined by means of arithmetic summation between intrinsic, aero-damping of cable and supplemental damping of damper. However linear combination approach by means of the arithmetic summation is not enough theoretical background. So validity of this approach should be verified in order to design adequate cable-damper system by engineers. This study establishes governing differential equation which can consider intrinsic, aero-damping and supplemental damping as well. And also analysis method is solved by combination of muller method and successive iteration method. Consequently, this study succeeds in verification for validity of linear combination approach. As a result of this study, linear combination approach is limitedly effective in case of low stiffness and optimum damping coefficient of damper, short distance from support to damper, lower vibration mode, low aero-damping, and normal windy environment. Whereas this study will be effective in case of opposite conditions, and existing studies or linear combination approach occur to further error. Meaning of this study presents exact solution for net damping of cable-damper system, and verifies linear combination approach by means of the analysis method. In the future, if monitoring of optimum damping coefficient of a damper against aero-damping is feasible on time, algorithm of this study will be available for control of cable and semi-active damper system such as magneto-rheological damper.

Performance Evaluation of Pansharpening Algorithms for WorldView-3 Satellite Imagery

  • Kim, Gu Hyeok;Park, Nyung Hee;Choi, Seok Keun;Choi, Jae Wan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.4
    • /
    • pp.413-423
    • /
    • 2016
  • Worldview-3 satellite sensor provides panchromatic image with high-spatial resolution and 8-band multispectral images. Therefore, an image-sharpening technique, which sharpens the spatial resolution of multispectral images by using high-spatial resolution panchromatic images, is essential for various applications of Worldview-3 images based on image interpretation and processing. The existing pansharpening algorithms tend to tradeoff between spectral distortion and spatial enhancement. In this study, we applied six pansharpening algorithms to Worldview-3 satellite imagery and assessed the quality of pansharpened images qualitatively and quantitatively. We also analyzed the effects of time lag for each multispectral band during the pansharpening process. Quantitative assessment of pansharpened images was performed by comparing ERGAS (Erreur Relative Globale Adimensionnelle de Synthèse), SAM (Spectral Angle Mapper), Q-index and sCC (spatial Correlation Coefficient) based on real data set. In experiment, quantitative results obtained by MRA (Multi-Resolution Analysis)-based algorithm were better than those by the CS (Component Substitution)-based algorithm. Nevertheless, qualitative quality of spectral information was similar to each other. In addition, images obtained by the CS-based algorithm and by division of two multispectral sensors were shaper in terms of spatial quality than those obtained by the other pansharpening algorithm. Therefore, there is a need to determine a pansharpening method for Worldview-3 images for application to remote sensing data, such as spectral and spatial information-based applications.

Establishment of a Tm-shift Method for Detection of Cat-Derived Hookworms

  • Fu, Yeqi;Liu, Yunqiu;Abuzeid, Asmaa M.I.;Huang, Yue;Zhou, Xue;He, Long;Zhao, Qi;Li, Xiu;Liu, Jumei;Ran, Rongkun;Li, Guoqing
    • Parasites, Hosts and Diseases
    • /
    • v.57 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Melting temperature shift ($T_m-shift$) is a new detection method that analyze the melting curve on real-time PCR thermocycler using SYBR Green I fluorescent dye. To establish a $T_m-shift$ method for the detection of Ancylostoma ceylanicum and A. tubaeforme in cats, specific primers, with GC tail of unequal length attached to their 5' end, were designed based on 2 SNP loci (ITS101 and ITS296) of the internal transcribed spacer 1 (ITS1) sequences. The standard curve of $T_m-shift$ was established using the standard plasmids of A. ceylanicum (AceP) and A. tubaeforme (AtuP). The $T_m-shift$ method stability, sensitivity, and accuracy were tested with reference to the standard curve, and clinical fecal samples were also examined. The results demonstrated that the 2 sets of primers based on the 2 SNPs could accurately distinguish between A. ceylanicum and A. tubaeforme. The coefficient of variation (CV) of $T_m$- values of AceP and AtuP was 0.07% and 0.06% in ITS101 and was 0.06% and 0.08% in ITS296, respectively. The minimum detectable DNA concentration was $5.22{\times}10^{-6}$ and $5.28{\times}10^{-6}ng/{\mu}l$ samples of AceP and AtuP, respectively. The accuracy of $T_m-shift$ method reached 100% based on examination of 10 hookworm DNA samples with known species. In the clinical detection of hookworm in 69 stray cat fecal sample, the $T_m-shift$ detection results were consistent with the microscopic examination and successfully differentiated between the 2-hookworm species. In conclusion, the developed method is a rapid, sensitive and accurate technique and can provide a promising tool for clinical detection and epidemiological investigation of cat-derived hookworms.

Comparison Study of AAS and ISE Method in the Lithium Analysis of Serum and Urine (혈액 및 소변의 Lithium치 측정에 있어서 AAS법과 ISE법의 비교)

  • Lee, Soo-In;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.2
    • /
    • pp.409-416
    • /
    • 1993
  • In the method for lithium (Li) analysis, flame emission photometry and atomic absorption spectrophotometry (AAS) have been used most frequently. In addition, lithium can be analyzed by ion-selective electrode (ISE) or fluorscence polarization immunoassay. We evaluated the comparison between AAS method based on the principle of absorption of light at 670.8 nm by Li and ISE method based on the principle of voltage difference generated by Li in contact with lithium ionophore. We compared with those obtained by AAS (AA/AE Spectrophotometer 551, Instrumentation Laboratory Co.) and ISE(CSYNCHRON EL-ISE, Beckman Co.) in the serum and urine of 6 patients and evaluated time-related changes of serum lithium concentration after dosing in both methods. The results are summarized as follows : 1. In within-run precision study for lithium concentration, coefficient variations (CVs, %) ranged from 1.34 to 2.17 for AAS and from 0.34 to 0.85 for ISE method. In between-run precision study for lithium concentration, CVs ranged from 1.23 to 1.72 for AAS and from 0.61 to 1.38 for ISE method. 2. The correlation study between AAS and ISE method resulted in Y=0.946X+0.137 (N=32, r=0.933, X=AAS, Y=ISE) for serum lithium and Y=1.092X+0.977 (N=28, r=0.943, X=AAS, Y=ISE) for urine lithium. 3. Time-related changes of serum lithium concentration in both AAS and ISE method resulted in peak serum levels about 2 hours after dosing and then rapidly decreased after the peak serum level and finally arrived at nearly initial levels about 9 hours after dosing. 4. The reference range of serum lithium was found as undetectable level for both AAS and ISE method and the reference range of urine lithium to the urine creatinine was 0-0.00014 mmol/mg(mean 0.00002 mmol/mg) for AAS method.

  • PDF

The Comparative Study of NHPP Software Reliability Model Based on Exponential and Inverse Exponential Distribution (지수 및 역지수 분포를 이용한 NHPP 소프트웨어 무한고장 신뢰도 모형에 관한 비교연구)

  • Kim, Hee-Cheul;Shin, Hyun-Cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.133-140
    • /
    • 2016
  • Software reliability in the software development process is an important issue. Software process improvement helps in finishing with reliable software product. Infinite failure NHPP software reliability models presented in the literature exhibit either constant, monotonic increasing or monotonic decreasing failure occurrence rates per fault. In this paper, we were proposed the reliability model with the exponential and inverse exponential distribution, which made out efficiency application for software reliability. Algorithm to estimate the parameters used to maximum likelihood estimator and bisection method, model selection based on mean square error (MSE) and coefficient of determination($R^2$), for the sake of efficient model, were employed. Analysis of failure, using real data set for the sake of proposing the exponential and inverse exponential distribution, was employed. This analysis of failure data compared with the exponential and inverse exponential distribution property. In order to insurance for the reliability of data, Laplace trend test was employed. In this study, the inverse exponential distribution model is also efficient in terms of reliability because it (the coefficient of determination is 80% or more) in the field of the conventional model can be used as an alternative could be confirmed. From this paper, the software developers have to consider life distribution by prior knowledge of the software to identify failure modes which can be able to help.

Genetic Relationships among the Parental Bombyx mori Strains of the Current F$_1$ Hybrid Silkworm based on RAPD (RAPD를 이용한 장려누에품종의 원종간 유전적 유연관계)

  • 황재삼;이진성;강현아;이상몽;손해룡
    • Korean journal of applied entomology
    • /
    • v.36 no.3
    • /
    • pp.206-214
    • /
    • 1997
  • The genetic relationships among the twenty parental silkworm, Bombyx mori strains authorized in Korea were evaluated using RAPDs-PCR(Random Amplified Polymorphic DNAs-Polymerase Chain Reaction). Twenty-six different 10-mer oligonucleotide primers were used to screen genetic characteristics of parental twenty silkworm strains by RAPD-PCR analysis. 24 primers showed different banding patterns among the strains. Based on these RAPD patterns, the genetic relationships among the silkworm strains were analyzed by UPGMA(Unweighed Pair-Group Method with Arithmetic average) method. The phylogenetic relationships in the twenty silkworm strains were classified into two major sub-groups at the genetic similarity coefficient of 0.60. The first sub-group included Jaml13, Jaml 19, Jaml20, Jam123, Jam1 25 and Jam 127. Jamll4, Jam1 2 I, Jam 122, Jam 124, Jam1 26, Jam 128, Jam129, Jam 130, Jam 131, Jam1 32, Jam133, Jam134, Jam301 and Jam302 were included in the 2nd group. The genetic distance values among Jam1 14, Jam120 and Jam127 were lower than those among the other strains, while Jam129 is very closely related to Jam131 as showing coefficient value of 1 .O.

  • PDF

Clinical Study of the Floating-Sinking Pulse Quantification Analysis on Ages, Left/Right, and Palpation Positions (20/60대 여성을 중심으로 살펴본 좌우 촌관척 부/침맥 정량화 임상연구)

  • Kim, Jae-Uk;Kim, Sung-Hun;Jeon, Young-Ju;Ryu, Hyun-Hee;Lee, Yu-Jung;Lee, Hae-Jung;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1193-1198
    • /
    • 2009
  • Pulse diagnosis is a central diagnosis method used in traditional Oriental medicine. To standardize and modernize the pulse diagnosis method, it is essential to develop an instrument-based reinterpretation of the clinically used pulse images in terms of the physical quantities such as the strength, period, width, length, and depth of the pulse. As a step towards such standardization, we conducted a clinical study on the floating/sinking pulses based on an automated palpation instrument (3D-MAC, Daeyo Medi, Korea) for 213 female subjects in their 20s and 174 female subjects in their 60s. The floating/sinking pulses are the two representative pulse images depending only on the depth of the pulse, and can be conveniently scaled by the coefficient of the floating-sinking pulse ($C_{fs}{\in}(0,1)$), which represents how strong one should apply the hold-down pressure to obtain the maximal pulse strength. As a result, primarily we found that it tends to appear more floating-like pulse ($C_{fs}{\rightarrow}0$) at Gwan and more sinking-like pulse ($C_{fs}{\rightarrow}1$) at Cheek, at both age groups and at both wrists. This result is consistent with a previous study on the geometrical structure of the blood vessel by an ultrasonograph. Second, the pulse tends to be more sinking-like in the age group of 60s than 20s. Finally, the pulses at the right palpation positions were found to be more sinking-like than the left, at both age groups.