• Title/Summary/Keyword: coefficient-based method

Search Result 2,699, Processing Time 0.033 seconds

A Study of Medication Adherence Using Textile Proximity Sensor (섬유 근접센서를 이용한 복약 여부 평가에 관한 연구)

  • Ho, Jong Gab;Wang, Changwon;Min, Se Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1257-1262
    • /
    • 2016
  • The purpose of this study is to evaluate whether to take a medicine based on a measuring data using textile proximity sensor. We developed a proximity sensor of ring type using conductive textile, and acquired a data in accordance with the quantity of each pills. To evaluate our approach, we designed an experimental protocol that is counting pills subtracting the one which contains range of 0 T(Tablet, 4,100mg) from 20 T. And, The experiments were performed a nine times in the same way. In order to remove a noise and smoothen data, data preprocessing were performed using resampling method and moving average filter which has ten points. Then, we calculated a linear trend line equation, and analyzed a correlation between pill quantity and trend line equation. As a results, correlation coefficient was shown at 0.833 through using a Spearman's correlation method and we could be determined that data was continuos decreases when take a medicine.

A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis (민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출)

  • Oh, Jihyun;Kwon, Soonjung;Kim, Sunsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.23 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

A Study on the Development of Plugging Margin Evaluation Method Reflected the Fouling of a Shell-and-Tube Heat Exchanger (다관원통형 열교환기의 파울링 현상을 고려한 관막음 여유 평가법 개발 연구)

  • Hwang, Kyeong-Mo;Jin,Tae-Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1384-1389
    • /
    • 2004
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of domestic nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions as a means of heat exchanger management. Except for the fouling level generated in operation of heat exchangers, also, all of the tubes of heat exchangers have been replaced when the number of plugged tubes exceeds the plugging criteria based on design performance sheet. This paper describes the plugging margin evaluation mettled reflected the fouling of shell-and-tube heat exchangers, which can evaluate the thermal performance for heat exchangers, estimate the future fouling variations, and reflect the current fouling level. To identify the effectiveness of the developed method, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

The Correlation between Ddesign Pparameter of Ssmall Tturbo Ffen and Ssound Qquality (소형터보홴 설계인자와 음질의 상관관계)

  • Jung, Young-Gyu;Kim, Hooi-Joong;Lee, Jung-Soo;Lee, Seung-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.826-829
    • /
    • 2005
  • The State of the art of low noise fan design requires the consideration of optimal sound quality. The influential design parameters of the noise level by the centrifugal fan were selected that based on a preliminary test. The centrifugal fans were designed according from the experiment plan method by specify the selected design parameters. The experiments with the machined mock-up's of centrifugal impellers revealed the major design parameters having impacts upon the indices of sound quality (e.g. loudness, sharpness, roughness and fluctuation strength) at the same performance condition. With a response surface method. the major design parameters selected were analyzed to estimate their contributions upon the sound quality of the centrifugal fan and the optimal values were drawn for the consideration of the sound quality by using each level and its regression equation. In addition, the validity of the regression equations were numerically verified by means of the coefficient of determination. Furthermore, the mechanism of how the centrifugal fans influence the determinants of sound quality was suggested.

  • PDF

Modeling of diffusion-reaction behavior of sulfate ion in concrete under sulfate environments

  • Zuo, Xiao-Bao;Sun, Wei;Li, Hua;Zhao, Yu-Kui
    • Computers and Concrete
    • /
    • v.10 no.1
    • /
    • pp.79-93
    • /
    • 2012
  • This paper estimates theoretically the diffusion-reaction behaviour of sulfate ion in concrete caused by environmental sulfate attack. Based on Fick's second law and chemical reaction kinetics, a nonlinear and nonsteady diffusion-reaction equation of sulfate ion in concrete, in which the variable diffusion coefficient and the chemical reactions depleting sulfate ion concentration in concrete are considered, is proposed. The finite difference method is utilized to solve the diffusion-reaction equation of sulfate ion in concrete, and then it is used to simulate the diffusion-reaction process and the concentration distribution of sulfate ion in concrete. Afterwards, the experiments for measuring the sulfate ion concentration in concrete are carried out by using EDTA method to verify the proposal model, and results show that the proposed model is basically in agreement with the experimental results. Finally, Numerical example has been completed to investigate the diffusion-reaction behavior of sulfate ion in the concrete plate specimen immersed into sulfate solution.

All-optical Signal Processing of Fiber Impairments in Dual-Polarization 112 Gbit/s m-ary QAM Coherent Transmission

  • Asif, Rameez;Islam, Muhammad Khawar;Zafrullah, Muhammad
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • We have numerically implemented a receiver side all-optical signal processing method, i.e. optical backward propagation (OBP), by dispersion compensating fiber (DCF) and non-linear compensator (NLC) devised by effective negative Kerr non-linear coefficient using two highly non-linear fibers (HNLFs). The method is implemented for the post-processing of fiber transmission impairments, i.e. chromatic dispersion (CD) and non-linearities (NL). The OBP module is evaluated for dual-polarization (DP) m-ary (m=4,16,32,64,256) quadrature amplitude modulation (QAM) in 112 Gbit/s coherent transmission over 1200 km standard single mode fiber (SMF). We have also investigated an intensity limited optical backward propagation module (IL-OBP) by using a self-phase modulation-based optical limiter with an appropriate pre-chirping to compensate for the intensity fluctuations in the transmission link. Our results show that in highly non-linear sensitive 256QAM transmission, we have observed a 66% increase in the transmission distance by implementing IL-OBP as compared to conventional OBP.

Structural, morphological, optical, and photosensing properties of Cs2TeI6 thin film synthesized by two-step dry process

  • Hoat, Phung Dinh;Van Khoe, Vo;Bae, Sung-Hoon;Lim, Hyo-Jun;Hung, Pham Tien;Heo, Young-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.279-285
    • /
    • 2021
  • Recently, cesium tellurium iodine (Cs2TeI6) has emerged as an inorganic halide perovskite material with potential application in optoelectronic devices due to its high absorption coefficient, suitable bandgap and because it consists of nontoxic and earth-abundant elements. However, studies on its fabrication process as well as photoresponse characteristics are limited. In this study, a simple and effective method is introduced for the synthesis of Cs2TeI6 thin films by a two-step dry process. A Cs2TeI6-based lateral photosensor was fabricated, and its photoresponse characteristics were explored under laser illuminations of four different wavelengths in the visible range: 405, 450, 520, and 655 nm. The initial photosensing results suggest potential application and can lead to more promising studies of Cs2TeI6 film in optoelectronics.

Nonlinear analysis of viscoelastic micro-composite beam with geometrical imperfection using FEM: MSGT electro-magneto-elastic bending, buckling and vibration solutions

  • Alimirzaei, S.;Mohammadimehr, M.;Tounsi, Abdelouahed
    • Structural Engineering and Mechanics
    • /
    • v.71 no.5
    • /
    • pp.485-502
    • /
    • 2019
  • In this research, the nonlinear static, buckling and vibration analysis of viscoelastic micro-composite beam reinforced by various distributions of boron nitrid nanotube (BNNT) with initial geometrical imperfection by modified strain gradient theory (MSGT) using finite element method (FEM) are presented. The various distributions of BNNT are considered as UD, FG-V and FG-X and also, the extended rule of mixture is used to estimate the properties of micro-composite beam. The components of stress are dependent to mechanical, electrical and thermal terms and calculated using piezoelasticity theory. Then, the kinematic equations of micro-composite beam using the displacement fields are obtained. The governing equations of motion are derived using energy method and Hamilton's principle based on MSGT. Then, using FEM, these equations are solved. Finally the effects of different parameters such as initial geometrical imperfection, various distributions of nanotube, damping coefficient, piezoelectric constant, slenderness ratio, Winkler spring constant, Pasternak shear constant, various boundary conditions and three material length scale parameters on the behavior of nonlinear static, buckling and vibration of micro-composite beam are investigated. The results indicate that with an increase in the geometrical imperfection parameter, the stiffness of micro-composite beam increases and thus the non-dimensional nonlinear frequency of the micro structure reduces gradually.

Pseudo seismic and static stability analysis of the Torul Dam

  • Karabulut, Muhammet;Genis, Melih
    • Geomechanics and Engineering
    • /
    • v.17 no.2
    • /
    • pp.207-214
    • /
    • 2019
  • Dams have a great importance on energy and irrigation. Dams must be evaluated statically and dynamically even after construction. For this purpose, Torul dam built between years 2000 and 2007 Harsit River in Gümüşhane province, Turkey, is selected as an application. The Torul dam has 137 m height and 322 GWh annual energy production capacity. Torul dam is a kind of concrete face rock fill dam (CFRD). In this study, static and pseudo seismic stability of Torul dam was investigated using finite element method. Torul dam model is constituted by numerical stress analysis named Phase2 which is based on finite element method. The dam was examined under 11 different water filling levels. Thirteenth stage of the numerical model is corresponding full reservoir condition which water filled up under crest line. Besides, pseudo static coefficients for dynamic condition applied to the dam in fourteenth stage of the model. Stability assessment of the Torul dam has been discussed according to the displacement throughout the dam body. For static and pseudo seismic cases, the displacements in the dam body have been compared. The total displacements of the dam according to its the empty state increase dramatically at the height of the water level of about 70 m and above. Compared to the pseudo-seismic analysis, the displacement of dam at the full reservoir condition is approximately two times as high as static analysis.

An efficient optimization approach for wind interference effect on octagonal tall building

  • Kar, Rony;Dalui, Sujit Kumar;Bhattacharjya, Soumya
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.111-128
    • /
    • 2019
  • In this paper an octagon plan shaped building (study building) in presence of three square plan shaped building is subjected to boundary layer wind flow and the interference effects on the study building is investigated using Computational fluid dynamics. The variation of the pressure coefficients on different faces of the octagon building is studied both in isolated and interference conditions. Interference Factors (IF) are calculated for different faces of the study building which can be a powerful tool for designing similar plan shaped buildings in similar conditions. A metamodel of the IF, in terms of the distances among buildings is also established using Response Surface Method (RSM). This set of equations are optimized to get the optimum values of the distances where the IF is unity. An upstream Interference zone for this building setup and wind environment is established from these data. Uncertainty principle is also utilised to determine the optimum positions of the interfering buildings considering the uncertain nature of wind flow for minimum interference effect. The proposed procedure is observed to be computationally efficient in deciding optimum layout at buildings often required in city planning. The results show that the proposed RSM-based optimization approach captures the interference zone accurately with substantially less number of experiments.