• Title/Summary/Keyword: coefficient-based method

Search Result 2,699, Processing Time 0.03 seconds

A Logit Type of Public Transit Trip Assignment Model Considering Stepwise Transfer Coefficients (Stepwise 환승계수를 고려한 Logit 유형 대중교통통행배정모형)

  • SHIN, Seongil;BAIK, Namcheol
    • Journal of Korean Society of Transportation
    • /
    • v.34 no.6
    • /
    • pp.570-579
    • /
    • 2016
  • This study proposes a concept of Stepwise Transfer Coefficient(STC) which implies greater transfer cost with increasing the number of transfers. Thus, the public transport information system provides the choice sets of travel routes by the consideration of not only transportation time but also the optimum number of transfers. However, path choice problems that involve STC are found to include non additive cost, which requires additional route enumeration works. Discussions on route enumeration in actual transportation networks is very complicated, thereby warranting a theoretical examination of route search considering STC. From these points of view, this study results in a probability based transit trip assignment model including STC. This research also uses incoming link based entire route deletion method. The entire route deletion method proposed herein simplifies construction of an aggregation of possible routes by theoretically supporting the process of enumeration of the different routes from origin to destination. Conclusively, the STC reflected route based logit model is proposed as a public transportation transit trip assignment model.

Negative Corona Onset Characteristic of the UHV Conductors Based on the Corona Cage

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Xie, Xiongjie
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2089-2097
    • /
    • 2014
  • Negative corona onset characteristics of the stranded conductors based on the ultra-high voltage (UHV) corona cage were studied in the paper. Based on the corona self-sustaining criterion in extreme uneven electric fields and the secondary emission process of the photoelectrons, the corona onset calculation model in the UHV corona cage is established and the corona current tests of the single LGJ900-75, 6 bundle LGJ900-75, 8 bundle LGJ400-35 conductors in dry and rain conditions were done in the UHV corona cage, and the rain rates are 2.4 mm/h, 20 mm/h and 30 mm/h. Corona onset electric field strength is gained by E-I tangent method, and the onset electric field strength in dry condition proves that the calculation model can be used to calculate the corona onset characteristics of the bundle conductors in the UHV corona cage. A further analysis proves that: the negative corona onset voltage of the conductor increases with the bundle number and the diameter of the sub conductor, but decreases with the bundle space in the corona cage. The onset electric field strength is influenced little by bundle space and bundle number, but decreases with the increase of the diameter of the sub-conductor. The surface irregularity coefficient decreases with the rain rate.

Portable Piezoelectric Film-based Glove Sensor System for Detecting Internal Defects of Watermelon (수박 내부결함판정을 위한 휴대형 압전형 장갑 센서시스템)

  • Choi, Dong-Soo;Lee, Young-Hee;Choi, Seung-Ryul;Kim, Hak-Jin;Park, Jong-Min;Kato, Koro
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.30-37
    • /
    • 2008
  • Dynamic excitation and response analysis is an acceptable method to determine some of physical properties of agricultural product for quality evaluation. There is a difference in the internal viscoelasticity between sound and defective fruits due to the difference of geometric structures, thereby showing different vibration characteristics. This study was carried out to develop a portable piezoelectric film-based glove sensor system that can separate internally damaged watermelons from sound ones using an acoustic impulse response technique. Two piezoelectric sensors based on polyvinylidene fluoride (PVDF) films to measure an impact force and vibration response were separately mounted on each glove. Various signal parameters including number of peaks, energy ratio, standard deviation of peak to peak distance, zero-crossing rate, and integral value of peaks were examined to develop a regression-estimated model. When using SMLR (Stepwise Multiple Linear Regression) analysis in SAS, three parameters, i.e., zeros value, number of peaks, and standard deviation of peaks were selected as usable factors with a coefficient of determination ($r^2$) of 0.92 and a standard error of calibration (SEC) of 0.15. In the validation tests using twenty watermelon samples (sound 9, defective 11), the developed model provided good capability showing a classification accuracy of 95%.

DEVELOPMENT OF CHLOROPHYLL ALGORITHM FOR GEOSTATIONARY OCEAN COLOR IMAGER (GOCI)

  • Min, Jee-Eun;Moon, Jeong-Eon;Shanmugam, Palanisamy;Ryu, Joo-Hyung;Ahn, Yu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.162-165
    • /
    • 2007
  • Chlorophyll concentration is an important factor for physical oceanography as well as biological oceanography. For these necessity many oceanographic researchers have been investigated it for a long time. But investigation using vessel is very inefficient, on the other hands, ocean color remote sensing is a powerful means to get fine-scale (spatial and temporal scale) measurements of chlorophyll concentration. Geostationary Ocean Color Imager (GOCI), for ocean color sensor, loaded on COMS (Communication, Ocean and Meteorological Satellite), will be launched on late 2008 in Korea. According to the necessity of algorithm for GOCI, we developed chlorophyll algorithm for GOCI in this study. There are two types of chlorophyll algorithms. One is an empirical algorithm using band ratio, and the other one is a fluorescence-based algorithms. To develop GOCI chlorophyll algorithm empirically we used bands centered at 412 nm, 443 nm and 555 nm for the DOM absorption, chlorophyll maximum absorption and for absorption of suspended solid material respectively. For the fluorescence-based algorithm we analyzed in-situ remote sensing reflectance $(R_{rs})$ data using baseline method. Fluorescence Line Height $({\Delta}Flu)$ calculated from $R_{rs}$ at bands centered on 681 nm and 688 nm, and ${\Delta}Flu_{(area)}$ are used for development of algorithm. As a result ${\Delta}Flu_{(area)}$ method leads the best fitting for squared correlation coefficient $(R^2)$.

  • PDF

Study on Evaluation Method of Flow Characteristics in Steady Flow Bench(5)-Effect of Evaluation Position (정상유동 장치에서 유동 특성 평가 방법에 대한 연구(5) - 평가위치의 영향)

  • Cho, Siehyung;Ohm, Inyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.179-189
    • /
    • 2017
  • This paper is the fifth investigation on the methods of evaluating flow characteristics in a steady flow bench. In previous studies, several assumptions used in the steady flow bench were examined and it was concluded that the assumption of the solid rotation may lead to serious problems. In addition, though the velocity profiles were improved as the measuring position went downstream, the distributions were far from ideal regardless of the valve angle and evaluation position. The eccentricities were also not sufficiently small to disregard the effect on impulse swirl meter (ISM) measurement. Therefore, the effect of these distribution and eccentricity changes according to the positions needs to be analyzed to discuss the method of flow characteristics estimation. In this context, the effects of evaluation position on the steady flow characteristics were studied. For this purpose, the swirl coefficient and swirl ratio were assessed and compared via measurement of the conventional ISM and calculation based on the velocity by particle image velocimetry(PIV) from 1.75B, 1.75 times bore position apart from the cylinder head, to the 6.00B position. The results show that the swirl coefficients by ISM strictly decrease and the curves as a function of the valve lift become smooth and linear as the measuring position goes downstream. However, the values through the calculation based on the PIV are higher at the farther position due to the approach of the tangential velocity profile to ideal. In addition, there exists an offset effect between the velocity distribution and eccentricity in the low valve lift range when the coefficients are estimated based on the swirl center. Finally, the curve of the swirl ratio by ISM and by PIV evaluation as a function the measuring position intersect around 5.00B plane except at $26^{\circ}$ valve angle.

Personalized Bookmark Recommendation System Using Tag Network (태그 네트워크를 이용한 개인화 북마크 추천시스템)

  • Eom, Tae-Young;Kim, Woo-Ju;Park, Sang-Un
    • The Journal of Society for e-Business Studies
    • /
    • v.15 no.4
    • /
    • pp.181-195
    • /
    • 2010
  • The participation and share between personal users are the driving force of Web 2.0, and easily found in blog, social network, collective intelligence, social bookmarking and tagging. Among those applications, the social bookmarking lets Internet users to store bookmarks online and share them, and provides various services based on shared bookmarks which people think important.Delicious.com is the representative site of social bookmarking services, and provides a bookmark search service by using tags which users attach to the bookmarks. Our paper suggests a method re-ranking the ranks from Delicious.com based on user tags in order to provide personalized bookmark recommendations. Moreover, a method to consider bookmarks which have tags not directly related to the user query keywords is suggested by using tag network based on Jaccard similarity coefficient. The performance of suggested system is verified with experiments that compare the ranks by Delicious.com with new ranks of our system.

Development of Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Sensitive Determination of Trace Copper in Water and Beverage Samples by Flame Atomic Absorption Spectrometry

  • Wu, Chunxia;Zhao, Bin;Li, Yingli;Wu, Qiuhua;Wang, Chun;Wang, Zhi
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.829-835
    • /
    • 2011
  • A dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) has been developed as a new approach for the extraction of trace copper in water and beverage samples followed by the determination with flame atomic absorption spectrometry. In the DLLME-SFO, 8-hydroxy quinoline, 1-dodecanol, and methanol were used as chelating agent, extraction solvent and dispersive solvent, respectively. The experimental parameters related to the DLLME-SFO such as the type and volume of the extraction and dispersive solvent, extraction time, sample volume, the concentration of chelating agent and salt addition were investigated and optimized. Under the optimum conditions, the enrichment factor for copper was 122. The method was linear in the range from 0.5 to $300\;ng\;mL^{-1}$ of copper in the samples with a correlation coefficient (r) of 0.9996 and a limit of detection of $0.1\;ng\;mL^{-1}$. The method was applied to the determination of copper in water and beverage samples. The recoveries for the spiked water and beverage samples at the copper concentration levels of 5.0 and $10.0\;ng\;mL^{-1}$ were in the range between 92.0% and 108.0%. The relative standard deviations (RSD) varied from 3.0% to 5.6%.

Genetic Diversity and Phylogenetic Relationships among Microsporidian Isolates from the Indian Tasar Silkworm, Antheraea mylitta, as Revealed by RAPD Fingerprinting Technique

  • Hassan, Wazid;Nath, B. Surendra
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.29 no.2
    • /
    • pp.169-178
    • /
    • 2014
  • In this study, we investigated genetic diversity of 22 microsporidian isolates infecting tropical tasar silkworm, Antheraea mylitta collected from various geographical forest locations in the state of Jharkhand, India, using polymerase chain reaction (PCR)-based marker assay: random amplified polymorphic DNA (RAPD). A type species, NIK-1s_mys was used as control for comparison. The shape of mature microsporidians was found to be oval to elongate, measuring 3.80 to $5.10{\mu}m$ in length and 2.56 to $3.30{\mu}m$ in width. Of the 20 RAPD primers screened, 16 primers generated reproducible profiles with 298 polymorphic fragments displaying high degree of polymorphism (97%). A total of 14 RAPD primers produced 45 unique putative genetic markers, which were used to differentiate the microsporidians. Calculation of genetic distance coefficients based on dice coefficient method and clustering with un-weighted pair group method using arithmetic average (UPGMA) analysis was conducted to unravel the genetic diversity of microsporidians infecting tasar silkworm. The similarity coefficients varied from 0.059 to 0.980. UPGMA analysis generated a dendrogram with four microsporidian groups, which appear to be different from each other as well as from NIK-1s_mys. Two-dimensional distribution based on Euclidean distance matrix also revealed considerable variability among different microsporidians identified from the tasar silkworms. Clustering of few microsporidian isolates was in accordance with the geographic origin. The results indicate that the RAPD profiles and specific/unique genetic markers can be used for differentiating as well as to identify different microsporidians with considerable accuracy.

A Study on CPA Performance Enhancement using the PCA (주성분 분석 기반의 CPA 성능 향상 연구)

  • Baek, Sang-Su;Jang, Seung-Kyu;Park, Aesun;Han, Dong-Guk;Ryou, Jae-Cheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.5
    • /
    • pp.1013-1022
    • /
    • 2014
  • Correlation Power Analysis (CPA) is a type of Side-Channel Analysis (SCA) that extracts the secret key using the correlation coefficient both side-channel information leakage by cryptography device and intermediate value of algorithms. Attack performance of the CPA is affected by noise and temporal synchronization of power consumption leaked. In the recent years, various researches about the signal processing have been presented to improve the performance of power analysis. Among these signal processing techniques, compression techniques of the signal based on Principal Component Analysis (PCA) has been presented. Selection of the principal components is an important issue in signal compression based on PCA. Because selection of the principal component will affect the performance of the analysis. In this paper, we present a method of selecting the principal component by using the correlation of the principal components and the power consumption is high and a CPA technique based on the principal component that utilizes the feature that the principal component has different. Also, we prove the performance of our method by carrying out the experiment.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.