• Title/Summary/Keyword: coefficient-based method

Search Result 2,699, Processing Time 0.033 seconds

ACE surrogate Model-Based uncertainty and sensitivity analysis methods for severe accident codes

  • Kwang-Il Ahn
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3686-3699
    • /
    • 2024
  • This paper explores the alternating conditional expectation (ACE) algorithm-based surrogate model to advance the state-of-practice in uncertainty and sensitivity analysis methodologies for severe accident codes. For engineering purposes, the ACE algorithm has been used as an alternative means to find the optimal functional forms of the multiple input variables and response variables of interest. Analysis results here demonstrate that compared with the reference cases the proposed surrogate model provides much higher performance in terms of the coefficient of determination (R2) and normalized root mean square error (NRMSE), thus giving more robust insights into the relationship and correlation between the input parameters and figures of merit (FOMs) of interest. Relevant results and insights are summarized in terms of points of interest.

Variation of Crop Coefficient With Respect to the Reference Crop Evapotranspiration Estimation Methods in Ponded Direct Seeding Paddy Rice (담수직파재배 논벼의 기준작물 잠재증발산량 산정방법별 작물계수의 변화)

  • 정상옥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.4
    • /
    • pp.114-121
    • /
    • 1997
  • In order to provide basic information for the estimation of evapotranspiration in the ponded direct seeding paddy field, both field lysimeter experiment and model prediction were performed to estimate daily ET. Various methods were used to predict daily reference crop ET and crop coefficients. Measure4 mean daily ET during the 1995 growing season varied from 5.9 to 6.1 mm depending on the species, while it varied from 5.1 to 5.5 mm in 1996. Model predicted mean daily ET during the 1995 growing season varied from 3.9 to 4.9 mm depending on the prediction model, while it varied from 3.5 to 4.7 mm in 1996. The smaller ET values both measured and predicted in 1996 were caused by the low values of temperature, sunshine hours, and solar radiation. Crop coefficients varied from 1.20 to 1.50 in 1995 depending on the prediction model, while it varied from 1.10 to 1.47 in 1996. Comparison of the seven reference crop ET prediction methods used in this study shows that the Penman-Monteith method and the FAO-Radiation method gave the lowest ET while the corrected Penman method and the Hargreaves method gave the largest ET. Since crop coefficients vary to a large extent based on the prediction methods, reference crop ET prediction method should be carefully selected in irrigation planning.

  • PDF

A Submode Selection Method for Advanced Intra Coding in H.263 (H.263 Advanced Intra Coding 모드 선택 방법)

  • 박운기;이상희;전병우
    • Journal of Broadcast Engineering
    • /
    • v.6 no.2
    • /
    • pp.187-194
    • /
    • 2001
  • The Advanced Intra Coding(AIC) mode included in the H.263+ which is for video ceding at low bit rates, selects one prediction direction of DCT coefficients among three directions for every intra macroblock. Based ()n the selected direction, It uses a different DCT scanning order, quantization scheme, and VLC table. The use of the AIC mode brings higher compression ratio and improved PSNR than the H.263 baseline. This paper proposes a simplified submode selection method for a direction of the DCT coefficient prediction for advanced ultra coding in H.263. Compared to the conventional method the proposed simplified method can achieve a similar coding Performance at computational complexity reduced to 1/7 and with much less memory requirement. The proposed method will be useful in implementing a simplified H.263 system.

  • PDF

Quantitative Analysis of the Degree of Silanization by the Ninhydrin Method and its Application to the Immobilization of GL-7-ACA Acylase and Cellulolytic Enzyme

  • Park, Seung-Won;Kim, Yong-In;Chung, Koo-Hun;Kim, Seung-Wook
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.199-203
    • /
    • 2001
  • A simple quantitative method to measure the degree of silanization was developed, based on the reaction of ninhydrin with the silanization reagent (3-aminopropyltriethoxysilane, 3-APTES). At low concentrations (0.001-0.005%, v/v) of 3-APTES, a good linearity was obtained when 3-APTES reacted with undiluted ninhydrin for 30 min. On the other hand, at high levels of 3-APTES, a linearity was obtained when 3-APTES reacted with 3-fold diluted ninhydrin for 20 min. The reliability of regression curves mentioned above was expressed as a regression coefficient ($R^2$) of more than 0.99. Immobilization of different enzymes was introduced via silanization by using the 3-APTES in order to confirm the validity of the ninhydrin method. When yield for each step in the immobilizatio process were compared, yields of both glutaraldehyde and protein were founc to have the same tendency to silanization. These results shw that the ninhydrin method was suitable for quatitative analysis of silanization and that yields of immobilization could be pre-estimated by measuring silanization levels using the ninhydrin method.

  • PDF

A study on the rainfall runoff from paddy fields in the small watershed during Irrigation period (관개기관중 답유역에서의 강우유출량 추정에 관한 연구)

  • 김채수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.4
    • /
    • pp.99-108
    • /
    • 1982
  • This thesis aims to estimate the rainfall runoff from paddy field in a small watershed during irrigation period. When the data observed at the proposed site are not available, the Monthly Runoff Equation of Korean Rivers which was derived from data observed under the following assumptions is used to study the water balance. a. Monthly base flow was assumed as 10. 2mm even if these is no mouthly rainmfall. b. Monthly comsumption of rainfall was ranged from 100 to 2OOmm without relation to the rainfall depth. However, the small watershed which consists mainly of paddy fields encounters severe droughts and accordingly the baseflow is negligible. Under the circumstances the author has developed the following equation called "Flood Irrigation Method for Rainfall Runoff "taking account of the evapotranspiration, precipitation, seepage, less of transportation, etc. R= __ A 7000(1 +F) -5n(n+1)+ (n+1)(Pr-S-Et)] where: R: runoff (ha-m) A: catchment area (ha) F: coefficient of loss (o.o-0. 20) Pr: rainfall (mm) S: seepage Er: evapotranspiration (mm) To verify the above equation, the annual runoff ratio for 28 years was estimated using the Monthly Runoff Equation of Korean Rivers the Flood Irrigation Method and the Complex Hydrograph Method based on meteorological data observed in the Dae Eyeog project area, and comparison was made with data observed in the Han River basin. Consequently, the auther has concluded that the Flood Irrigation Method is more consi- stent with the Complex Hydrograph Method and data observed than the Monthly Runoff Equation of Korean Rivers.

  • PDF

Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.439-443
    • /
    • 2019
  • To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction in a CZT pixelated semiconductor gamma camera system. The gamma camera system simulated is a CZT pixelated semiconductor detector with a pixel-matched parallel-hole collimator and the spatial resolution phatnom was designed with the Geant4 Application for Tomography Emission (GATE). In addition, a noise reduction algorithm with a median filter using an improved thresholding method is developed and we applied our proposed algorithm to an acquired spatial resolution phantom image. According to the results, the proposed median filter improved the noise characteristics compared to a conventional median filter. In particular, the average for normalized noise power spectrum, contrast to noise ratio, and coefficient of variation results using the proposed median filter were 10, 1.11, and 1.19 times better than results using conventional median filter, respectively. In conclusion, our results show that the proposed median filter using improved the thresholding method results in high imaging performance when applied in a CZT semiconductor gamma camera system.

Vibro-acoustic modelling of immersed cylindrical shells with variable thickness

  • Wang, Xianzhong;Lin, Hongzhou;Zhu, Yue;Wu, Weiguo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.343-353
    • /
    • 2020
  • Based on the Precise Transfer Matrix Method (PTMM), the dynamic model is constructed to observe the vibration behaviour of cylindrical shells with variable thickness by solving a set of first-order differential equations. The free vibration of stiffened cylindrical shells with variable thickness can be obtained to compare with the exact solution and FEM results. The reliability of the present method of free vibration is well proved. Furthermore, the effect of thickness on the vibration responses of the cylindrical shell is also discussed. The acoustic response of immersed cylindrical shells is analyzed by a Pluralized Wave Superposition Method (PWSM). The sound pressure coefficient can be gained by collocating points along the meridian line to satisfy the Neumann boundary condition. The mode convergence analysis of the cylindrical shell is carried out to guarantee calculation precision. Also, the reliability of the present method on sound radiation is verified by comparing with experimental results and numerical results.

Cyanide detection based on natural dyes reaction from blue butterfly pea flowers (Clitoria Ternatea)

  • Chotichayapong, Chatrachatchaya;Kuchaiyaphum, Pusita;Butwong, Nutthaya;Bua-ngern, Worapong
    • Analytical Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.153-160
    • /
    • 2022
  • A green spectrophotometric method for the determination of cyanide has been proposed using, a green reagent, aqueous extract of blue butterfly pea. The test tube was filled with anthocyanin rich extract (pH 6) and cyanide solution. The reaction was kept constant for 10 minutes at room temperature. The reaction mixture changed color from blue to green as the amount of CN-ions increased. The 620 nm peak intensity increased with CN concentration. Therefore, this wavelength was used for all cyanide analyses. The cyanide calibration curve had a linear range of 0.25-1.00, 1.00-4.00, and 4.00-10.00 mg/L, with a satisfactory correlation coefficient of 0.99 and a LOD of 0.57 mg/L. The recovery ranged from 8.33 to 76.94 percent, indicating that this method is inaccurate at low cyanide concentrations. The intra-day and intermediate precision relative deviations were 0.391-0.871 % and 1.112-1.583 %. An H-bond forms between the C-4 group of the B-carbonyl ring and the HCN molecule according to the B3LYP/TZVP calculation. The method is convenient for cyanide concentrations above the LOQ of 1.09 mg/L, cost-effective, and capable of reducing toxic solvents with acceptable precision. The method could also be used to detect total cyanide in biological, environmental, and industrial waste samples.

Observer Variation Factor on Advanced Method for Accurate, Robust, and Efficient Spectral Fitting of java Based Magnetic Resonance User Interface for MRS data analysis (java Based Magnetic Resonance User Interface의 Advanced Method for Accurate, Robust, and Efficient Spectral Fitting 분석방법의 관찰자 변동 요소)

  • Lee, Suk-Jun;Yu, Seung-Man
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • The purpose of this study was examined the measurement error factor on AMARES of jMRUI method for magnetic resonance spectroscopy (MRS) quantitative analysis by skilled and unskilled observer method and identified the reason of independent observers. The Point-resolved spectroscopy sequence was used to acquired magnetic resonance spectroscopy data of 10 weeks male Sprague-Dawley rat liver. The methylene protons ($(-CH_{2-})n$) of 1.3 ppm and water proton ($H_2O$) of 4.7 ppm ratio was calculated by LCModel software for using the reference data. The seven unskilled observers were calculated total lipid (methylene/water) using the jMRUI AMARES technique twice every 1 week, and we conducted interclass correlation coefficient (ICC) statistical analysis by SPSS software. The inter-observer reliability (ICC) of Cronbach's alpha value was less than 0.1. The average value of seven observer's total lipid ($0.096{\pm}0.038$) was 50% higher than LCModel reference value. The jMRUI AMARES analysis method is need to minimize the presence of the residual metabolite by identified metabolite MRS profile in order to obtain the same results as the LCModel.

A Study on the Pyroelectric Properties of PZT(30/70) Thick film Prepared by Using 1,3 Propanediol (1,3 Propanediol을 이용해 제작된 PZT(30/70) 후막의 초전특성에 관한 연구)

  • Song, Kum-Suck;Chang, Dong-Hoon;Joung, Yang-Hee;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.9-15
    • /
    • 2004
  • PZT(30/70) thick film was fabricated by using 1,3 propanediol-based sol-gel method. Prepared film of pyroelectric property was investigated by Dynamic method of modulation frequency dependence. Pyroelectric coefficient was obtained about $5.0{\times}10^{-8}\;C/cm^2{\cdot}K$. The figure of merits for voltage responsively and specific detectivity were $3.4{\times}10^{-11}\;C{\cdot}cm/J$ and $5.9{\times}10^{-9}\;C{\cdot}cm/J$, respectively, because of relative high-dielectric constant and high-pyroelectric coefficient. Voltage responsively was increased at low modulation frequency and it was decreased at high modulation frequency. Voltage responsively was maximum 1.84 V/W at 10Hz. As Johnson noise is dominant, Noise voltage was increased nearly proportional to $f^{-1/2}$. Noise equivalent power and specific detectivity were $2.83{\times}10^{-7}\;W/Hz^{1/2}$ and 3.13{\times}10^5\;cm{\cdot}Hz^{1/2}/W$ the same frequency at 80Hz, respectively.